Search NASA⌕ Search

SEARCH · Search NASA

Results for “VEIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Petrology, Geochemistry, and Pairing of Lunar Meteorites from the Dominion Range

Introduction: During the 2018-2019 Antarctic Search for Meteorites (ANSMET) field season in the Dominion Range (DOM), 7 lunar meteorite stones were collected: DOM 18242 (15.1 g), DOM 18244 (25.1 g), DOM 18262 (6.8 g), DOM 18509 (16.5 g), DOM 18543 (13.6 g), DOM 18666 (45.9 g), and DOM 18678 (11.6 g). Here we present the initial results of electron microprobe and X-ray computed tomography (XCT) studies of these stones and look at the details of their petrography and mineral chemistry, as well as investigate possible pairing relationships, both with each other and with previously described lunar meteorites. Most of the work presented here is on the DOM 18509, 18543, and 18678 stones; subsamples of the other stones are in hand and similar measurements will be made on them by the time of the meeting. Methods: Textures in DOM 18509, DOM 18543, and DOM 18678 were characterized in 2D by optical microscopy, backscattered electron (BSE) imaging and elemental X-ray images on thin sections, as well as in 3D by X-ray computed tomography (XCT) on sample chips. Mineral compositions were assessed through a combination of wavelength dispersive spectroscopy EPMA (electron probe microanalysis) and x-ray mapping on the JEOL 8530 at NASA JSC. The bulk composition of all three meteorites was determined based on analyses of the fusion crust glass. XCT analyses were done on the Nikon XTH 320 at NASA JSC. ICP-MS data on bulk rock subsamples for each meteorite will be carried out in the near future. Results: The stones are all similar in macroscopic appearance with a dark aphanitic matrix hosting a variety of small- to medium-sized angular mineral and lithic fragments (often light colored in nature) [1,2]. Based on EPMA and XCT results, the three meteorites are polymict regolith breccias comprised of mineral, glass, and lithic clasts ranging up to several mm in length. Melt veins run through all three meteorite samples. Mineral clasts in all 3 stones are dominated by pyroxene and plagioclase (An82-96), with minor amounts of SiO2, olivine (Fo1-52), and FeTi-oxides. Pyroxene grains are mostly Fe-rich pigeonite and augite, and larger clasts are normally zoned and have fine exsolution lamellae. The lithic clasts in all stones consists of: (1) basalt clasts that contain zoned pyroxene, plagioclase laths, and ilmenite, with minor silica and Fe-rich olivine; (2) granulitic clasts; (3) anorthosite clasts; (4) Si-rich clasts that also contain ilmenite, troilite, high-Ca pyroxene, fayalite, and K-feldspar likely mesostasis from late stage basalts). All three meteorites contain glassy fusion crust that is highly vesicular, high in FeO and Al2O3 (15-17 wt% each), ferroan (Mg# of 23-24), and moderately rich in TiO2 (1.4-1.8 wt%). The composition of the fusion crust can serve as a proxy for the bulk meteorite composition and is identical within error for all three meteorites. Implications: The lithic and mineral clasts in all three stones are similar in clast population and assemblages as well as mineral chemistry. In addition, the fusion crust composition, a proxy for bulk composition, is within error of each other for all three stones. Thus DOM 18509, DOM 18543, and DOM 18678 are almost certainly paired. Based on similarities in macroscopic description as well as preliminary classification data [1,2], all 7 lunar stones from DOM are likely paired, though additional quantitative analyses are needed to confirm this. The presence of spherules and vesicular fusion crusts indicates that the DOM pairing group is a regolith breccia. The presence of basaltic and gabbroic clasts as well as more feldspathic materials, suggest that the regolith from which these meteorites formed contained a mixture of feldspathic highland material and mare material, suggesting a possible provenance near a marehighlands boundary. No evidence of KREEPy lithologies have been observed so far in these meteorites, however, future ICP-MS data on bulk rock chips for the stones will reveal any KREEP component if present. The DOM pairing group has many similarities to previously described lunar breccia meteorite MET 01210, however more detailed compositional data will be needed to make a definitive comparison.

R.A. Zeigler↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Space-Cent: Studying the Physiological and Anatomical Effects of Centrifugation and Head Down Tilt: 2021 Update

BACKGROUND The objective of this study was to evaluate the cerebral and ocular physiological and anatomical effects of head-down tilt bedrest (HDBR) with and without daily artificial gravity (AG) in healthy subjects to provide novel insights into possible countermeasures for the Spaceflight Associated Neuro-ocular Syndrome (SANS). Previous long-term studies using the spaceflight analog of strict 6° HDBR for 30 days revealed changes in ocular structure, including optic disc edema. The effects of an AG countermeasure using intermittent centrifugation to restore upright hydrostatic gradients and reduce the ocular and brain anatomical effects has not been explored. METHODS The effects of 60-day exposure to simulated microgravity (6° HDBR) on the cerebral, ocular and vestibular systems with and without the intervention of daily 30 minute exposure to AG (short-arm centrifugation) was evaluated in 24 healthy subjects. Non-invasive measurements of cerebral blood flow, intracranial blood volume (near infrared spectroscopy, NIRS), cerebral and ocular structure (MRI and optical coherence tomography), internal jugular vein area (ultrasound), lateral ventricular volumes (MRI), intraocular pressure, and sensorimotor/vestibular (i.e. balance and coordination) systems were made during various time-points during the bedrest study. Additional measures with ultrasound and NIRS were made during centrifugation. RESULTS The study began in Spring 2019 and all 24 subjects completed the testing by end of 2019. Data analysis continues. We report the following updated results for 2021. MRI showed significant decreases in carotid artery flow, increases in brain and CSF volumes, and aqueductal flow velocities in all subjects in HDT compared to baseline supine, but no effects of the short duration AG. All groups showed increased posterior globe flattening during bedrest compared to baseline, without protection from AG. As previously reported we observed chorioretinal folds for the first time in a bedrest analog, as well as optic disc edema, with no protection from the short-term AG. Data from the study is now being transmitted to the NASA LSDA which will allow for future research. CONCLUSIONS The 6 degree HDBR analog produced significant changes in the anatomical and physiological functions of the brain and eye in healthy subjects. Daily 30 minute exposure to AG with short-arm centrifugation had significant transient effects on physiology of the cerebrovascular system, but was not sufficient to prevent the anatomical effects of HDBR on the brain and eye.

E M Bershad↗

The Spleen in Spaceflight

Studies related to splenic physiology during spaceflight have focused on its immune function. However, the internal jugular deep vein thrombosis discovered during a recent space mission spotlighted that the circulatory and hemostatic physiology of spaceflight is not yet well understood and likely involve not only aspects of hemodynamics, but also the output of the reticuloendothelial system (RES), which effects homeostasis via RBC clearance, mediates platelet formation and storage, blood viscosity, and thrombotic functions. On Earth, the spleen plays an active role in the RES and hemostatic physiology. What role might the spleen play in circulation hemostatic physiology during spaceflight and what alterations in its function should be expected in the microgravity environment? In reviewing the literature to date we sought to understand: - Splenic effects on RBC clearance, anemia, and hemostasis - Splenic and splanchnic contributions to arterial and venous blood storage - How splenic and splanchnic physiology may alter in microgravity

Samuel Ko↗

Tin-Essako 001: A Metal-Rich Ureilite?

Introduction: Metal-rich achondrites include a variety of types, and likely have a variety of origins. Models range from gravitational mixing at the core-mantle boundaries of differentatiated asteroids, to complex impact mixing scenarios. We describe a new type of metal-rich achondrite that might be the first metal-rich ureilite. Sample: Tin-Essako (TE) 001 (~4.3 g) was found in Mali in 2020 and purchased by Jay Piatek in 2021. It was classified as a metal-rich ungrouped achondrite, with olivine and oxygen isotope (d18O=8.2810‰, d17O=3.718‰, avg. 3) compositions suggesting affinity to ureilites [1]. We studied one polished section (~187.7 mm2) of TE 001. Petrography: TE 001 consists of ~60% metal and 40% silicates, heterogeneously distributed. The metal is largely fresh, but iron oxides (presumably terrestrial) occur along one edge and in some patches and veins in the interior. The silicates are dominantly olivine (≥90%), with melt-textured areas of plagioclase + Si-rich glass. Minor phases include chromite and carbon. Olivine occurs as rounded grains (up to ~2.5 mm) in metal, commonly with rims of melt-textured plagioclase + glass. Olivine also occurs in more massive areas having a “honeycomb” texture, with rounded olivine “cells” surrounded by an interstitial network of reduced olivine riddled with tiny metal grains, plus melt-textured plagioclase + Si-rich glass. Chromite occurs as subhedral to rounded grains; smaller grains (30-250 mm) are included in olivine and a few larger grains (400-500 mm) are isolated within metal. A carbon phase occurs as lacy-textured rims around olivine grains in metal, or small patches within metal. Mineral Compositions: The olivine (excluding interstitial areas) is Fo 73.9±0.5, with 0.25±0.02 wt.% CaO, 0.31±0.01 wt% Cr2O3, 0.01 wt.% NiO, and molar Fe/Mn=49.8±2.2 (53 analyses). Olivine in interstitial areas has Fo up to at least 91. Smaller chromite grains have Fe# (molar Fe/[Fe+Mg]) = 0.54±0.01, Cr# (molar Cr/[Cr+Al]) = 0.52±0.01, 0.52±0.02 wt.% V2O3 and 0.21±0.04 wt% ZnO (28 analyses). One larger grain is zoned from Fe# = 0.45, Cr# =0.52 to Fe# = 0.40, Cr# =0.57, and contains thin Al-rich lamellae not resolved by EMPA. One irregularly shaped patch of chromite included in olivine has Fe# =0.26 and contains no ZnO. Plagioclase laths are An ~53-60, with ≤0.01 wt.% K2O. Glass contains 75-76 wt% SiO2 and ~16 wt% Al2O3. The metal contains 5.2±0.2 wt% Ni, 0.46±0.02 wt.% Co, and 0.01±0.01 wt.% Cr, with Si and P below detection (168 analyses). Discussion: The olivine + chromite assemblage in TE 001 is similar to the most ferroan ureilites (Fo ~75-79 [2]), as are the oxygen isotopes [1]. The presence of a carbon phase supports this, although the identity of this phase (graphite as in ureilites?) remains to be determined. The “honeycomb” textured areas, in particular, the presence of olivine “reduction rims,” resemble shock-smelted olivine areas in ureilites [3], but interstitial melt-textured plagioclase laths + glass like those in TE 001 have not been reported in such (or any) ureilites. Olivine in TE 001 is marginally more ferroan than in the most FeO-rich ureilite, with Fe-Mg-Mn composition offset from the trend of olivine + low-Ca pyroxene ureilites similar to augite-bearing ureilites [4]. CaO and Cr2O3 contents are in the range of those in ureilite olivine [ ] , though Cr2O3 is at the extreme low end of the range [5]. Chromites (except the unusual one) have similar Fe# to the most ferroan primary chromites in ureilites [2], but distinctly lower Cr# (0.52 vs. 0.71). Metal compositions are with the range for metal in ureilites [7]. The absence of pyroxene and sulfide, and the high abundance of metal in TE 001, are unlike ureilites. One possibility is that a ferroan, chromite-bearing, pyroxene-poor ureilite was invaded (possibly due to impact) by a metallic liquid (low S content suggests very high temperature), resulting in complete melting of pyroxene and smelting of olivine, with rapid recrystallization of melted silicate as plagioclase + glass. Alternatively, a pre-existing metal-rich ureilite assemblage may have been impact melted. Additional types of data will be obtained to evaluate these hypotheses (i.e., is the metal indigenous?) and assess affinity to ureilites.

olivine↗

Adrianite, Ca12(Al4Mg3Si7)O32Cl6, a New Cl-rich Silicate Mineral From the Allende Meteorite: An Alteration Phase in a Ca-Al-rich Inclusion

Adrianite (IMA 2014-028), Ca12(Al4Mg3Si7)O32Cl6, is a new Cl-rich silicate mineral and the Si,Mg analog of wadalite. It occurs with monticellite, grossular, wadalite, and hutcheonite in altered areas along some veins between primary melilite, spinel, and Ti,Al-diopside in a Type B1 FUN (Fractionation and Unidentified Nuclear effects) Ca-Al-rich inclusion (CAI), Egg-3, from the Allende CV3 carbona-ceous chondrite. The mean chemical composition of type adrianite by electron probe microanalysis is (wt%) CaO 41.5, SiO2 27.5, Al2O3 12.4, MgO 7.3, Na2O 0.41, Cl 13.0, O=Cl –2.94, total 99.2, giving rise to an empirical formula of (Ca11.69Na0.21)(Al3.85Mg2.88Si7.23)O32Cl5.80. The end-member formula is Ca12(Mg5Si9)O32Cl6. Adrianite has the I43d wadalite structure with a = 11.981 Å, V = 1719.8 Å3, and Z = 2, as revealed by electron backscatter diffraction. The calculated density using the measured composition is 3.03 g/cm3. Adrianite is a new secondary mineral in Allende, apparently formed by alkali-halogen metasomatic alteration of primary CAI minerals such as melilite, anorthite, perovskite, and Ti,Al-diopside on the CV chondrite parent asteroid. Formation of secondary Cl-rich minerals sodalite, adrianite, and wadalite during metasomatic alteration of the Allende CAIs suggests that the metasomatic fluids had Cl-rich compositions. The mineral name is in honor of Adrian J. Brearley, mineralogist at the University of New Mexico, U.S.A., in recognition of his many contributions to the understanding of secondary mineralization in chondritic meteorites.

Chi Ma↗

Adrianite, Ca12(Al4Mg3Si7)O32Cl6, a New Cl-rich Silicate Mineral from the Allende Meteorite: An Alteration Phase in a Ca-Al-rich Inclusion

Adrianite (IMA 2014-028), Ca12 (Al4Mg3Si7)O32Cl6, is a new Cl-rich silicate mineral and the Si, Mg analog of wadalite. It occurs with monticellite, grossular, wadalite, and hutcheonite in altered areas along some veins between primary melilite, spinel, and Ti, Al-diopside in a Type B1 FUN (Fractionation and Unidentified Nuclear effects) Ca-Al-rich inclusion (CAI), Egg-3, from the Allende CV3 carbonaceous chondrite. The mean chemical composition of type adrianite by electron probe microanalysis is (wt%) CaO 41.5, SiO2 27.5, Al2O3 12.4, MgO 7.3, Na2O 0.41, Cl 13.0, O=Cl –2.94, total 99.2, giving rise to an empirical formula of (Ca11.69Na0.21) (Al3.85Mg2.88Si7.23) O32Cl5.80. The end-member formula is Ca12 (Mg5Si9) O32Cl6. Adrianite has the I43d wadalite structure with a = 11.981 Å, V = 1719.8 Å3, and Z = 2, as revealed by electron backscatter diffraction. The calculated density using the measured composition is 3.03 g/cm3. Adrianite is a new secondary mineral in Allende, apparently formed by alkali-halogen metasomatic alteration of primary CAI minerals such as melilite, anorthite, perovskite, and Ti,Al-diopside on the CV chondrite parent asteroid. Formation of secondary Cl-rich minerals sodalite, adrianite, and wadalite during metasomatic alteration of the Allende CAIs suggests that the metasomatic fluids had Cl-rich compositions. The mineral name is in honor of Adrian J. Brearley, mineralogist at the University of New Mexico, U.S.A., in recognition of his many contributions to the understanding of secondary mineralization in chondritic meteorites.

Adrianite↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

The CheMin X-ray Diffractometer on MSL Curiosity: A Decade of Mineralogical Observations from Gale Crater, Mars

For more than a decade, the CheMin X-ray Diffraction instrument on the Mars Science Laboratory rover Curiosity has been returning quantitative mineralogical data from Gale crater, Mars. CheMin receives and analyzes sieved soil and powdered rock samples from Curiosity’s Sample Acquisition / Sample Processing and Handling (SA/SPaH) system. To date, 38 samples have been analyzed over the course of a 28 km transit. These samples document more than 600 vertical meters of flat-lying lacustrine, fluvial and aeolian sediments that comprise the lower part of the central mound of Gale crater (commonly called Mt. Sharp).The principal mineralogy of the sediments is basaltic, with evidence of early and late-stage diagenetic overprinting. The rocks in many cases preserve most of their primary mineralogy and sedimentary features, suggesting that they were never strongly heated or deformed. Using aeolian soil composition as a proxy for the composition of the deposited and lithified sediment, it appears that in many cases the diagenetic changes observed are principally isochemical. Exceptions to this include secondary nodules, calcium sulfate veining and rare alteration halos. A striking hematite-rich feature in lower Mt. Sharp called Vera Rubin Ridge is interpreted to be lake sediment diagenetically altered by silica-poor fluids. A surprising and as yet poorly understood observation is that nearly all of the 3.7 Gyr old sedimentary rocks analyzed to date are comprised of 25-50% X-ray amorphous material. Overall, this 600 m vertical section of sedimentary rock explored in lower Mt. Sharp documents a perennial shallow lake environment grading upward into alternating lacustrine/fluvial and aeolian environments. The mineralogical changes observed going up-section include a transition from trioctahedral to dioctahedral clay minerals and a transition from magnetite to hematite. More recently, in the last 150 m of section, CheMin has documented an overall decrease in clay minerals and increase in Fe3+ oxides and oxyhydroxides. The mineralogical changes observed in Gale crater may document the gradual drying out and oxidation of the martian hydrosphere.

CHEMIN↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics, including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics in weightlessness is limited to the left IJV assessed ~45 and ~150 days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness and therefore a risk for short-duration missions and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we investigated the effects of acute weightlessness during parabolic flight on the right and left IJV in 12 healthy subjects. Baseline ultrasound images were obtained on the ground (1g) in the seated and supine postures and during 0g parabolic flight. Each data collection session included 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the bilateral IJVs. RESULTS There was a similar pattern of response in the left and right IJV area across postures and g-levels. IJV area increased from seated to supine by 0.74 mm2 (95% CI: 0.56 to 0.91 mm2, p<.001) and increased further during weightlessness by 0.29 mm2 (95% CI: 0.11 to 0.47 mm2, p=.0015). IJV Doppler images revealed stagnant flow in the left IJV in one subject during 0g exposure that was not present during any imaging on the ground; the right IJV continued to show pulsatile, nominal flow patterns in both 0g and 1g. CONCLUSIONS This study characterized the immediate effect of the weightlessness-induced headward fluid shift on venous parameters in the left and right IJV. The left IJV appears to be more susceptible to flow alterations, including stagnant flow, during both short and long-duration exposure to weightlessness that may contribute to the risk of thrombosis inflight.

K Marshall-Goebel↗

Development of A Directed Acyclic Graph for Venous Thromboembolism During Spaceflight

Introduction: Recent studies have reported the development of venous blood flow stasis in astronauts and an occlusive venous thrombosis during spaceflight. Subsequent investigations revealed approximately one quarter of surveilled crew members had some degree of blood flow stasis in the left internal jugular vein. Therefore, NASA’s Human System Risk Board now formally tracks venous thromboembolism (VTE) as a “concern” for human spaceflight. To investigate potential mechanisms by which exposures concomitant with spaceflight (e.g., microgravity, radiation) may contribute to VTE, we developed a causal diagram in the form of a directed acyclic graph (DAG). Methods: The mechanisms by which spaceflight exposures may elevate the risk of VTE and the downstream effects on mission outcomes were critically analyzed, taking into account scientific literature and subject matter expertise consultation, and a DAG was generated. A Level-of-Evidence score for each causal relationship was assigned based on assessing the literature against a set of criteria derived from the A. Bradford Hill Causal Guidelines. Results: The set of three main factors that predispose people to VTE (hypercoagulability, endothelial damage, and blood stasis) is known as Virchow’s Triad. In constructing the DAG for VTE we articulated various mechanisms by which the principal spaceflight hazards (microgravity, radiation, closed hostile environment, isolation and confinement, distance from Earth) are thought to interact with or cause the components in Virchow’s triad. We found sufficient evidence to at least speculate that fluid shifts from microgravity, compensatory alterations in hematologic indices, spaceflight atmospheric conditions, and oxidative stress/inflammation from radiation may be potential contributors to VTE development. Discussion: Developing the DAG entailed a systematic and repeatable approach for visualizing relationships between contributing factors that may lead to VTE in spaceflight. Articulating pathways linking spaceflight exposures to VTE risk factors and possible VTE development enables subject matter experts from different domains to construct a shared mental model. Assignment of levels of evidence scores to the relationships helps identify knowledge and capability gaps that should be considered for further investigation. Furthermore, the DAG highlights modifiable variables and may therefore facilitate the development of new VTE risk mitigation strategies.

Alexander Svoronos↗

Mitigating Headward Fluid Shifts With Veno-Constrictive Thigh Cuffs During Spaceflight

Astronauts experience a chronic headward fluid shift in weightlessness as evidenced by increased cardiac output, decreased leg volume, a redistribution of venous fluid, and venous congestion in the upper body. Alterations in cerebrospinal fluid hydrodynamics and changes in cerebral venous pressure secondary to the headward fluid shift may contribute to ocular changes associated with spaceflight-associated neuro-ocular syndrome (SANS). Veno-constrictive thigh cuffs (VTC; Braslets) provided to Soyuz crewmembers alleviate symptoms of the headward fluid shift during the first week of spaceflight and have been documented to reduce internal jugular vein (IJV) distension during weightlessness. Application of VTCs designed collaboratively by NASA Johnson Space Center Cardiovascular and Vision Laboratory (CVL) and Clemson Textile Laboratory at Clemson University to improve fit and comfort was documented to mitigate changes in choroid thickness, intraocular pressure, and IJV area during posture-induced headward fluid shifts. VTC are demonstrated to reduce headward fluid shifts in both ground-based and spaceflight studies, and thus, may be a countermeasure against development of SANS. In addition, VTC are a simple mechanical countermeasure currently at a high technical readiness level (TRL) and are compact and lightweight, making them compatible with the spaceflight operations environment

Connor R. Ferguson↗

Radiative Heating Under Particulate-Laden Conditions During Hypersonic Planetary Entry

An important consideration while designing for hyper-sonic planetary entry is the interaction between the multitude of physical phenomena that manfist them-selves at these extreme conditions. This fact is also true for a Martian landing where in addition to thermo-chemical non-equilibriurm, vehicular predictions are impacted by radiative heating and potentially atmos-pheric dust. Previous studes have indicated that infra-red (IR) radiation emanating from CO2 and CO mole-cules constitute a significant fraction, especially in the backshell, of the total surface heat flux. In similar vein, dust particles, which can be present even under quiescent conditions, have been shown to increase the erosion rate of the heatshield. However, what remains relatively unquantified is the possible modification of the radiative environment due to the presence of dust. The present study is expected to provide the most de-tailed assessment to date of particles introducing changes to the radiative energy transfer both through the attenuation of existing shocked gas-induced radia-tion and additional emission.

Radiation↗

Surveillance for Jugular Venous Thrombosis in Long-Duration Space Flight: Findings From Twenty-Eight U.S. Astronauts

BACKGROUND: Given the high incidence of internal jugular vein (IJV) flow anomalies aboard the International Space Station and a case of thrombosis, the National Aeronautics and Space Administration (NASA) instituted an occupational surveillance program to evaluate astronauts for venous thromboembolism (VTE). Current findings of the program are presented. METHODS: NASA astronauts undergo pre- and in-flight VTE surveillance examinations using a standardized vascular ultrasound protocol, which includes evaluation for bilateral IJV compressibility, filling, flow, and spontaneous echo contrast (SEC). RESULTS: Twenty-eight NASA astronauts had terrestrial baseline examinations and at least one in-flight imaging session. The reduction of in-flight peak IJV flow speeds was significant and more pronounced on the left. Comparing the first in-flight measurement to the terrestrial baseline, peak flow speeds were reduced from 90.1±41.9 cm/s (average ±SD) to 62.1±31.6 cm/s on the right and from 76.9±41.8 cm/s to 26.8±18.2 cm/s on the left. Seven astronauts showed stagnant or retrograde flow in the left IJV. Fourteen developed appreciable SEC in the left IJV (7 greater than mild); none developed significant right-sided SEC. All IJVs were fully compressible and free from thrombi. DISCUSSION: Bilateral IJV flow speed reduction is observed in microgravity, possibly due to the multitude of available flow redistribution paths for cranial drainage. In a subset of astronauts, significant flow anomalies develop that may facilitate thrombus formation through changes in blood viscosity and speed, especially if combined with other thrombogenic factors. These findings warrant attention to the interplay between individual vascular configurations and the dynamic properties of blood as a non-Newtonian fluid in the reduced-shear flow environment of microgravity.

Ashot Sargsyan↗

Coordinated Analysis of Phosphates in Samples From Asteroid (101955) Bennu

Asteroid (101955) Bennu is a B-type asteroid and a prime candidate for investigating the remnants of planet formation and enhancing our understanding of potential sources of crucial bio-essential elements for the early Earth. Remote observations of the surface of Bennu unveiled a terrain of boulders primarily composed of hydrated phyllosilicates, organic molecules, and carbonates. The hydrated nature of Bennu, the abundance of carbonates, and the presence of cm-scale carbonate veins provide clues to the nature of the building blocks of Bennu’s parent body and to its complex geological history. Here we present the first mineralogical, chemical, and isotopic results of analysis of phosphates in samples returned from Bennu by NASA’s OSIRIS-REx mission. We seek to test the hypothesis that heating of Bennu’s parent asteroid resulted in hydrothermal alteration in which melted ice reacted with the initial constituents.

J. J. Barnes↗

The Chemistry and Mineralogy (CheMin) X-Ray Diffractometer on the MSL Curiosity Rover: A Decade of Mineralogy From Gale Crater, Mars

For more than a decade, the CheMin X-ray diffraction instrument on the Mars Science Laboratory rover Curiosity has been returning definitive and quantitative mineralogical and mineral-chemistry data from ~3.5-billion-year-old (Ga) sediments in Gale crater, Mars. To date, 40 drilled rock samples and 3 scooped soil samples have been analyzed during the rover’s 30+ km transit. These samples document the mineralogy of over 800 meters of flat-lying fluvial, lacustrine and aeolian sedimentary rocks that comprise the lower strata of the central mound of Gale crater (Aeolis Mons; informally known as Mt. Sharp) and the surrounding plains (Aeolis Palus, informally known as the Bradbury Rise). The principal mineralogy of the sedimentary rocks is basaltic, with evidence of early and late-stage diagenetic overprinting. The rocks in many cases preserve much of their primary mineralogy and sedimentary features, suggesting that they were never strongly heated or deformed. Using aeolian soil composition as a proxy for the composition of the deposited and lithified sediment, it appears that in many cases diagenetic changes observed are principally isochemical. Exceptions to this trend include secondary nodules, calcium sulfate veining, and rare Si-rich alteration halos. A surprising and yet poorly understood observation is that nearly all the ~3.5 Ga sedimentary rocks analyzed to date contain 15-70 wt.% of X-ray amorphous material. Over-all, this >800-meter section of sedimentary rock explored in lower Mt. Sharp documents a perennial shallow lake environment grading upward into alternating lacustrine/fluvial and aeolian environments, many of which would have been habitable to microbial life.

Mars↗

Preliminary Analyses of Asteroid Bennu Samples Returned by NASA’s OSIRIS-REx Mission

NASA’s OSIRIS-REx mission returned ~122 g of pristine carbonaceous regolith from Bennu on September 24, 2023. The science team is performing analyses of the mineralogy, chemical and isotopic compositions, and physical properties of the samples. The returned samples consist of particles ranging up to 3.5 cm in size with angular and hummocky morphologies predominating. Reflectance spectra over the visible and infrared wavelengths collected during the spacecraft encounter contained features indicating abundant hydrated phyllosilicates, carbonates, magnetite, organic matter, and rare anhydrous silicates. Laboratory analyses confirmed these detections and identified several other major and minor phases including abundant FeNi sulfides, minor hydrated Mg-rich phosphates as encrustations and in veins, and presolar grains. The Bennu samples show evidence for extensive aqueous alteration and resemble the rare and chemically primitive CI carbonaceous chondrites and samples returned from Ryugu by JAXA’s Hayabusa2 mission. Samples of Bennu’s uppermost surface, collected by contact pads, help us to understand how recent impacts and irradiation processes have changed the optical properties of Bennu surface materials measured by remote sensing. The analyses thus far highlight the value of sample return by illustrating the pristine nature of the samples compared to meteorites that have been compromised and altered by exposure to the terrestrial environment.

Lindsay P Keller↗