Velocity distribution measurements for near- free molecule flow through an orifice
Near-free molecular flow through orifice measured for velocity distribution dependence on Knudsen number and angular position using time-of-flight technique
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Near-free molecular flow through orifice measured for velocity distribution dependence on Knudsen number and angular position using time-of-flight technique
Fluid velocity is measured by focusing laser beam on moving fluid and measuring Doppler shift in frequency which results when radiation is scattered by particles either originally present or deliberately injected into moving fluid.
A wind tunnel experiment simulating a steady three-dimensional helicopter rotor blade/vortex interaction is reported. The experimental configuration consisted of a vertical semispan vortex-generating wing, mounted upstream of a horizontal semispan rotor blade airfoil. A three-dimensional laser velocimeter was used to measure the velocity field in the region of the blade. Sectional lift coefficients were calculated by integrating the velocity field to obtain the bound vorticity. Total lift values, obtained by using an internal strain-gauge balance, verified the laser velocimeter data. Parametric variations of vortex strength, rotor blade angle of attack, and vortex position relative to the rotor blade were explored. These data are reported (with attention to experimental limitations) to provide a dataset for the validation of analytical work.
Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.
Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD (charge-coupled device) camera was used to obtain two sequential images of the NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm horizontal, 0.7-mm vertical). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. A numerical study of measured velocity error due to a uniform and linearly-varying collisional rate distribution was performed. Quantification of systematic errors, the contribution of gating/exposure duration errors, and the influence of collision rate on temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the signal-to-noise ratio of the acquired profiles. This velocity measurement technique has been demonstrated for two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-Inch Mach 10 Air Tunnel.
A technique for measuring wind velocities of meteorological interest is described. It is based on inverse-square-law variation of the counting rates as the radioactive source-to-counter distance is changed by wind drag on the source ball. Results of a feasibility study using a weak bismuth 207 radiation source and three Geiger-Muller radiation counters are reported. The use of the technique is not restricted to Martian or Mars-like environments. A description of the apparatus, typical results, and frequency response characteristics are included. A discussion of a double-pendulum arrangement is presented. Measurements reported herein indicate that the proposed technique may be suitable for measuring wind speeds up to 100 m/sec, which are either steady or whose rates of fluctuation are less than 1 kHz.
Proposed technique for measuring wind velocity based on inverse-squarelaw variation of radioactive counting rates. In proposal, radioative source is deposited on bottom of light, hollow sphere and suspended by flexible wire over radiation counter, Anemometer based on this concept is self-contained, portable, yet not too fragile. Used for extended periods of time, even at remote, inhospitable and inaccessible sites.
It is shown that CW CARS can be used to measure velocity in supersonic flows. The accuracy with which the Doppler shift can be measured is determined through the drift in the laser frequencies. In the experiment described here, it is found that a laser drift error of 10 MHz during the recording of a spectrum would limit the velocity resolution to 34 m/s. It is noted that improved frequency stabilization of the laser sources could lead to a velocity measurement accuracy of several m/s. In the experiment, a 4-W single axial mode argon ion laser is the pump source, and the Stokes-shifted frequency is generated by a 100-mW tunable dye laser.
We report on a new technique for obtaining off-Hugoniot pressure vs. density data for solid metals compressed to extreme pressure by a magnetically driven liner implosion on the Z-machine (Z) at Sandia National Laboratories. In our experiments, the liner comprises inner and outer metal tubes. The inner tube is composed of a sample material (e.g., Ta and Cu) whose compressed state is to be inferred. The outer tube is composed of Al and serves as the current carrying cathode. Another aluminum liner at much larger radius serves as the anode. A shaped current pulse quasi-isentropically compresses the sample as it implodes. The iterative method used to infer pressure vs. density requires two velocity measurements. Photonic Doppler velocimetry probes measure the implosion velocity of the free (inner) surface of the sample material and the explosion velocity of the anode free (outer) surface. These two velocities are used in conjunction with magnetohydrodynamic simulation and mathematical optimization to obtain the current driving the liner implosion, and to infer pressure and density in the sample through maximum compression. This new equation of state calibration technique is illustrated using a simulated experiment with a Cu sample. Monte Carlo uncertainty quantification of synthetic data establishes convergence criteria for experiments. Results are presented from experiments with Al/Ta, Al/Cu, and Al liners. Symmetric liner implosion with quasi-isentropic compression to peak pressure ∼1000 GPa is achieved in all cases. These experiments exhibit unexpectedly softer behavior above 200 GPa, which we conjecture is related to differences in the actual and modeled properties of aluminum.
Langmuir probe velocity and acceleration measurements for coaxial Hall accelerators
Langmuir probe velocity and acceleration measurements for coaxial Hall accelerators
An inertial navigation system (INS) includes a primary inertial navigation system (INS) unit configured to receive accelerometer measurements from an accelerometer and angular velocity measurements from a gyroscope. The primary INS unit is further configured to receive global navigation satellite system (GNSS) signals from a GNSS sensor and to determine a first set of kinematic state vectors based on the accelerometer measurements, the angular velocity measurements, and the GNSS signals. The INS further includes a secondary INS unit configured to receive the accelerometer measurements and the angular velocity measurements and to determine a second set of kinematic state vectors of the vehicle based on the accelerometer measurements and the angular velocity measurements. A health management system is configured to compare the first set of kinematic state vectors and the second set of kinematic state vectors to determine faults associated with the accelerometer or the gyroscope based on the comparison.
Velocity dispersion measurements of recently discovered Milky Way satellites with M{sub V} {approx_gt} -7 imply that they posses high mass-to-light ratios. The expected velocity dispersions due to their baryonic mass are {approx}0.2 km s{sup -1}, but values {approx_gt}3 km s{sup -1} are measured. We perform Monte Carlo simulations of mock radial velocity measurements of these systems assuming that they have mass-to-light ratios similar to globular clusters and posses an unidentified binary star population, to determine if these stars could boost the velocity dispersion to the observed values. We find that this hypothesis is unlikely to produce dispersions much in excess of {approx}4.5 km s{sup -1}, in agreement with previous work. However, for the systems with the potentially smallest velocity dispersions, values consistent with observations are produced in 5%-40% of our simulations for binary fractions in excess of f {sub bin}(P {<=} 10 yr){approx} 5%. This sample includes the dwarf galaxy candidates that lie closest to classical globular clusters in M{sub V} - r{sub h} space. Considered as a population, it is unlikely that all of these dwarf galaxy candidates have mass-to-light ratios typical of globular clusters, but boosting of the observed dispersion by binaries from near-zero values cannot be ruled out at high confidence for several individual dwarf galaxy candidates. Given the importance of obtaining accurate velocity dispersions and dynamical masses for the faintest satellites, it is clearly desirable to directly exclude the possible effect of binaries on these systems. This requires multi-epoch radial velocity measurements with individual uncertainties of {approx_lt}1 km s{sup -1} to identify spectroscopic binaries with orbital velocities of the order of the observed velocity dispersion.
Utilizing the large magnitudes of Doppler shifts obtainable from a CW gas laser, local velocity vectors are measured by using the visible light from the laser. This technique is applicable for the measurement of velocity of any moving surface.
The Aeropropulsion Systems Test Facility (ASTF) C1 Test Cell is to be configured for propulsion tests of National Aerospace Plane (NASP) engines over flight Mach number conditions ranging from 0.5 to 3.8. This facility is capable of continuously generating a 5 ft. x 5 ft. square free air jet flow field at a local Mach number up to 3.32 with a density of between 0.134 and 0.048 amagat and a static temperature of 257 K or less. The potential of the Raman Excitation + Laser Induced Electronic Fluorescence (RELIEF) velocity measurement technique for measuring the three dimensional velocity profile across the exit plane of this jet and the entrance plane to the test engine under these conditions is examined. Velocity measurements must be done to an accuracy of better than 1 percent. Flow direction must be measured to better than 1 deg for inlet performance evaluation. Measurements to these specifications need to be done with a grid spacing of approximately 1/100th of the cross sectional dimension of the free jet exit in a time not greater than 30 seconds.
In recent years, the interest in developing a high-speed civil transport has increased. This has led to an increase in research activity on compressible supersonic flows, in particular the boundary layer. The structure of subsonic boundary layers has been extensively documented using conditional sampling techniques which exploit the knowledge of both u and v velocities. Researchers using these techniques have been able to explore some of the complex three-dimensional motions which are responsible for Reynolds stress production and transport in the boundary layer. As interest in turbulent structure has grown to include supersonic flows, a need for simultaneous multicomponent velocity measurements in these flows has developed. The success of conditional analysis in determining the characteristics of coherent motions and structures in the boundary layer relies on accurate, simultaneous measurement of two instantaneous velocity components.
We derive spatially resolved stellar kinematics for a sample of 84 out of 104 observed local (0.02 < z < 0.09) galaxies hosting type-1 active galactic nuclei (AGNs), based on long-slit spectra obtained at the 10 m W. M. Keck-1 Telescope. In addition to providing central stellar velocity dispersions, we measure major axis rotation curves and velocity dispersion profiles using three separate wavelength regions, including the prominent Ca H and K, Mg Ib, and Ca II NIR stellar features. In this paper, we compare kinematic measurements of stellar velocity dispersion obtained for different apertures, wavelength regions, and signal-to-noise ratios, and provide recipes to cross-calibrate the measurements reducing systematic effects to the level of a few percent. We also provide simple recipes based on readily observable quantities such as global colors and Ca H and K equivalent width that will allow observers of high-redshift AGN hosts to increase the probability of obtaining reliable stellar kinematic measurements from unresolved spectra in the region surrounding the Ca H and K lines. In subsequent papers in this series, we will combine this unprecedented spectroscopic data set with surface photometry and black hole mass measurements to study in detail the scaling relations between host galaxy properties and black hole mass.
Predictive constitutive equations that connect easy-to-measure transport properties (e.g., viscosity and conductivity) with system performance variables (e.g., power consumption and efficiency) are needed to design advanced thermal and electrical systems. In this work, we explore the use of fluorescent particle-streak analysis to directly measure the local velocity field of a pressure-driven flow, introducing a new Python package (FSVPy) to perform the analysis. Fluorescent streak velocimetry combines high-speed imaging with highly fluorescent particles to produce images that contain fluorescent streaks, whose length and intensity can be related to the local flow velocity. By capturing images throughout the sample volume, the three-dimensional velocity field can be quantified and reconstructed. We demonstrate this technique by characterizing the channel flow profiles of several non-Newtonian fluids: micellar Cetylpyridinium Chloride solution, Carbopol 940, and Polyethylene Glycol. We then explore more complex flows, where significant acceleration is created due to microscale features encountered within the flow. We demonstrate the ability of FSVPy to process streaks of various shapes and use the variable intensity along the streak to extract position-specific velocity measurements from individual images. Thus, we demonstrate that FSVPy is a flexible tool that can be used to extract local velocimetry measurements from a wide variety of fluids and flow conditions.