Search NASA⌕ Search

SEARCH · Search NASA

Results for “VISUAL SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of Strong Anaerobic Fluorescent Reporters for Clostridium acetobutylicum and Clostridium ljungdahlii Using HaloTag and SNAP-tag Proteins

One of the biggest limitations in the study and engineering of anaerobic Clostridium organisms is the lack of strong fluorescent reporters capable of strong and real-time fluorescence. Recently, we developed a strong fluorescent reporter system for Clostridium organisms based on the FAST protein. Here, we report the development of two new strong fluorescent reporter systems for Clostridium organisms based on the HaloTag and SNAP-tag proteins, which produce strong fluorescent signals when covalently bound to fluorogenic ligands. These new fluorescent reporters are orthogonal to the FAST ligands and to each other, allowing for simultaneous labeling and visualization. We used HaloTag and SNAP-tag to label the strictly anaerobic organisms Clostridium acetobutylicum and Clostridium ljungdahlii. We have also identified a new strong promoter for protein expression in C. acetobutylicum, based on the phosphotransacetylase gene (pta) from C. ljungdahlii. Furthermore, the HaloTag and the SNAP-tag, in combination with the previously described FAST system, were successfully used to measure cell populations in bacterial mixed cultures and showed the simultaneous orthogonal labeling of HaloTag and SNAP-tag together with the FAST protein reporter. Finally, we show the expression of recombinant fusion protein of FAST and the ZapA division protein (from C. acetobutylicum) in C. ljungdahlii. The availability of multiple strong fluorescent reporters is a major addition to the genetic toolkit of Here, Clostridium and other anaerobes that will lead to better understanding of these unique organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Live-Cell Quantum Dot-Based Tracking of Plant & Microbial Extracellular Vesicles

All cellular organisms examined to date release various types of small vesicles called extracellular vesicles (EVs). They were originally thought to be unimportant, but research into EVs as carriers of key messages for communication within large, multicellular organisms or between interacting organisms has gained interest in many different scientific areas of study. Recently, it was discovered that both plants and their pathogenic fungi generate EVs and they are important vehicles for sending plant signals to thwart invasion by fungal pathogens, and in response, fungi use EVs to help evade plant defenses. This project aimed to develop new ways to visualize EVs and their potential nucleic acid cargo isolated from the crop plant, sorghum. We adapted a click chemistry-based method for making quantum dot-based RNA sensors, which will be a useful tool for others studying small RNAs. These sensors were not used detect RNA in sorghum EVs because unlike EVs from Arabidopsis, sorghum EVs were not enriched for specific small RNAs. This interesting difference shifted the project in an exciting direction, which focused on comparing EV proteomes. Our study discovered that greater than 60% of Arabidopsis EV proteins were also found in the sorghum EV proteome, revealing a partial conservation between a eudicot and monocot plant. These studies have raised new, fundamental questions on the conserved function of EVs in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Individual recognition between mother and infant bats (Myotis)

The recognition process and the basis for that recognition, in brown bats, between mother and infant are analyzed. Two parameters, ultrasonic communication and olfactory stimuli, are investigated. The test animals were not allowed any visual contact. It was concluded that individual recognition between mother and infant occurred. However, it could not be determined if the recognition was based on ultrasonic signals or olfactory stimuli.

Turner, D.↗

Signature analysis of acoustic emission from graphite/epoxy composites

Acoustic emissions were monitored for crack extension across and parallel to the fibers in a single ply and multiply laminates of graphite epoxy composites. Spectrum analysis was performed on the transient signal to ascertain if the fracture mode can be characterized by a particular spectral pattern. The specimens were loaded to failure quasistatically in a tensile machine. Visual observations were made via either an optical microscope or a television camera. The results indicate that several types of characteristics in the time and frequency domain correspond to different types of failure.

Russell, S. S.↗

Turbulence control on airborne laser platform

An avctive flow control device to generate large-scale, periodic structures in a turbulent shear flow is developed. Together with adaptive optics, the device may be used on airborne laser platforms to reduce or eliminate optical distortion caused by the turbulence in the aircraft's boundary layer. A flat plate towed in a water channel is used as a test bed. A cyclic jet issuing from a spanwise slot is used to collect the turbulent boundary layer for a finite time during its 'on' period. When the jet is turned 'off', all of the turbulent fluid is released instantaneously in one large eddy that convects downstream. Flow visualization and hot-film probe measurements are used together with pattern recognition algorithms to demonstrate the viability of the flow control method. The instantaneous velocity signal is used to compute important statistical quantities of the random velocity field, such as the mean, the root-mean-square, the spectral distribution, and the probability density function. When optimized for a given boundary layer, the cyclic jet produces periodic structures that are qualitatively similar to the random, naturally occurring ones. These structures seem to trigger the onset of bursting events near the wall. Thus, the present device generates periodic structures in both the outer and inner regions of a turbulent boundary layer.

Gad-El-hak, Mohamed↗

High-Speed Self-Aligned Focusing Schlieren and Background-Oriented Schlieren with Pulsed Laser Illumination

Laser light sources are commonly used in schlieren-based flow visualization techniques that are in development at NASA Langley Research Center. Of particular interest are high-intensity, low coherence sources that allow for high signal-to-noise schlieren imagery to be acquired without the laser speckle that typically occurs as a result of interference. Results from a self-aligned focusing schlieren system developed at NASA Langley and a background-oriented schlieren system are presented to highlight the effectiveness of these sources.

Schlieren↗

Issues in visual support to real-time space system simulation solved in the Systems Engineering Simulator

The Systems Engineering Simulator has addressed the major issues in providing visual data to its real-time man-in-the-loop simulations. Out-the-window views and CCTV views are provided by three scene systems to give the astronauts their real-world views. To expand the window coverage for the Space Station Freedom workstation a rotating optics system is used to provide the widest field of view possible. To provide video signals to as many viewpoints as possible, windows and CCTVs, with a limited amount of hardware, a video distribution system has been developed to time-share the video channels among viewpoints at the selection of the simulation users. These solutions have provided the visual simulation facility for real-time man-in-the-loop simulations for the NASA space program.

Yuen, Vincent K.↗

Monitoring Location and Angular Orientation of a Pill

A mobile pill transmitter system moves through, or adjacent to, one or more organs in an animal or human body, while transmitting signals from its present location and/or present angular orientation. The system also provides signals from which the present roll angle of the pill, about a selected axis, can be determined. When the location coordinates angular orientation and the roll angle of the pill are within selected ranges, an aperture on the pill container releases a selected chemical into, or onto, the body. Optionally, the pill, as it moves, provides a sequence of visually perceptible images. The times for image formation may correspond to times at which the pill transmitter system location or image satisfies one of at least four criteria. This invention provides and supplies an algorithm for exact determination of location coordinates and angular orientation coordinates for a mobile pill transmitter (PT), or other similar device that is introduced into, and moves within, a GI tract of a human or animal body. A set of as many as eight nonlinear equations has been developed and applied, relating propagation of a wireless signal between either two, three, or more transmitting antennas located on the PT, to four or more non-coplanar receiving antennas located on a signal receiver appliance worn by the user. The equations are solved exactly, without approximations or iterations, and are applied in several environments: (1) association of a visual image, transmitted by the PT at each of a second sequence of times, with a PT location and PT angular orientation at that time; (2) determination of a position within the body at which a drug or chemical substance or other treatment is to be delivered to a selected portion of the body; (3) monitoring, after delivery, of the effect(s) of administration of the treatment; and (4) determination of one or more positions within the body where provision and examination of a finer-scale image is warranted.

Schipper, John F.↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

Aditya S. Acharya↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

lasers↗

Study of noise sources in a subsonic fan using measured blade pressures and acoustic theory

Sources of noise in a 1.4 m (4.6 ft) diameter subsonic tip speed propulsive fan running statically outdoors are studied using a combination of techniques. Signals measured with pressure transducers on a rotor blade are plotted in a format showing the space-time history of inlet distortion. Study of these plots visually and with statistical correlation analysis confirms that the inlet flow contains long, thin eddies of turbulence. Turbulence generated in the boundary layer of the shroud upstream of the rotor tips was not found to be an important noise source. Fan noise is diagnosed by computing narrowband spectra of rotor and stator sound power and comparing these with measured sound power spectra. Rotor noise is computed from spectra of the measured blade pressures and stator noise is computed using the author's stator noise theory. It is concluded that the rotor and stator sources contribute about equally at frequencies in the vicinity of the first three harmonics of blade passing frequency. At higher frequencies, the stator contribution diminishes rapidly and the rotor/inlet turbulence mechanism dominates. Two parametric studies are performed by using the rotor noise calculation procedure which was correlated with test. In the first study, the effects on noise spectrum and directivity are calculated for changes in turbulence properties, rotational Mach number, number of blades, and stagger angle. In the second study the influences of design tip speed and blade number on noise are evaluated.

Hanson, D. B.↗

Pulsations in total columnar electron content

Radio signals from the ATS 6 beacon received at Boulder reveal small-amplitude, quasi-sinusoidal fluctuations with periods in the range of 10 to 50 s. Visual comparisons of these data (116 events for October 1974 to April 1975) shows a good correspondence with simultaneous geomagnetic pulsations at Boulder in two thirds of the cases for which Boulder magnetograms were available, but they do not necessarily correspond with magnetic pulsations on ATS 6. Spectral analyses, by the method of maximum entropy, were made on sample records. The principal results are the following: (1) The occurrence of the pulsations is higher on magnetically disturbed days. (2) The maximum likelihood of occurrence is around 2100 UT (1400 LT). (3) The dominant spectrum peaks of the radio fluctuations and geomagnetic field on the ground generally coincide. Cases are found also in which temporal characteristics of the spectra are similar. These results indicate a close association of the radio fluctuations with the Pc 3-4 type pulsations of the geomagnetic field on the ground. It is suggested that the radio fluctuations originate mainly in the F region of the ionosphere, while some of them could be due to plasmapause effects.

Okuzawa, T.↗

Economical Video Monitoring of Traffic

Data compression allows video signals to be transmitted economically on telephone circuits. Telephone lines transmit television signals to remote traffic-control center. Lines also carry command signals from center to TV camera and compressor at highway site. Video system with television cameras positioned at critical points on highways allows traffic controllers to determine visually, almost immediately, exact cause of traffic-flow disruption; e.g., accidents, breakdowns, or spills, almost immediately. Controllers can then dispatch appropriate emergency services and alert motorists to minimize traffic backups.

Houser, B. C.↗

Cross-flow vortex structure and transition measurements using multi-element hot films

An experiment on a 45-degree swept wing was conducted to study three-dimensional boundary-layer characteristics using surface-mounted, micro-thin, multi-element hot-film sensors. Cross-flow vortex structure and boundary-layer transition were measured from the simultaneously acquired signals of the hot films. Spanwise variation of the root-mean-square (RMS) hot-film signal show a local minima and maxima. The distance between two minima corresponds to the stationary cross-flow vortex wavelength and agrees with naphthalene flow-visualization results. The chordwise and spanwise variation of amplified traveling (nonstationary) cross-flow disturbance characteristics were measured as Reynolds number was varied. The frequency of the most amplified cross-flow disturbances agrees with linear stability theory.

Agarwal, Naval K.↗

Demonstration of VOC Fenceline Sensors and Canister Grab Sampling near Chemical Facilities in Louisville, Kentucky

Experimental fenceline sensor pods (SPods) fitted with 30 s duration canister grab sampling (CGS) systems were deployed at a site near chemical facilities in Louisville, KY, from 4 June 2018 to 5 January 2020. The objective of the study was to better understand lower cost 10.6 eV photoionization detector (PID)-based volatile organic compound (VOC) sensors and investigate their utility for near-source emissions detection applications. Prototype SPods containing PID sensor elements from two different manufacturers yielded between 78% and 86% valid data over the study, producing a dataset of over 120,000 collocated pair fenceline measurements averaged into 5-min datapoints. Ten-second time-resolved SPod data from an elevated fenceline sensor signal day are presented, illustrating source emission detections from the direction of a facility 500 m west of the monitoring site. An SPod-triggered CGS acquired in the emission plume on this day contained elevated concentrations of 1,3-butadiene and cyclohexane (36 parts per billion by volume (ppbv) and 637 ppbv, respectively), compounds known to be emitted by this facility. Elevated concentrations of these compounds were observed in a subset of the 61 manual and triggered CGS grab samples acquired during the study, with winds from the west. Using novel wind-resolved visualization and normalization approaches described herein, the collocated pair SPod datasets exhibited similarity in emission source signature. With winds from the west, approximately 50% of SPod readings were above our defined theoretical detection limit indicating persistent measurable VOC signal at this site. Overall, this 19-month study demonstrated reasonable prototype SPod operational performance indicating that improved commercial forms of lower cost PID sensors could be useful for select VOC fenceline monitoring applications.

1,3-butadiene↗

Integration of vestibular and head movement signals in the vestibular nuclei during whole-body rotation

Single-unit recordings were obtained from 107 horizontal semicircular canal-related central vestibular neurons in three alert squirrel monkeys during passive sinusoidal whole-body rotation (WBR) while the head was free to move in the yaw plane (2.3 Hz, 20 degrees /s). Most of the units were identified as secondary vestibular neurons by electrical stimulation of the ipsilateral vestibular nerve (61/80 tested). Both non-eye-movement (n = 52) and eye-movement-related (n = 55) units were studied. Unit responses recorded when the head was free to move were compared with responses recorded when the head was restrained from moving. WBR in the absence of a visual target evoked a compensatory vestibulocollic reflex (VCR) that effectively reduced the head velocity in space by an average of 33 +/- 14%. In 73 units, the compensatory head movements were sufficiently large to permit the effect of the VCR on vestibular signal processing to be assessed quantitatively. The VCR affected the rotational responses of different vestibular neurons in different ways. Approximately one-half of the units (34/73, 47%) had responses that decreased as head velocity decreased. However, the responses of many other units (24/73) showed little change. These cells had signals that were better correlated with trunk velocity than with head velocity. The remaining units had responses that were significantly larger (15/73, 21%) when the VCR produced a decrease in head velocity. Eye-movement-related units tended to have rotational responses that were correlated with head velocity. On the other hand, non-eye-movement units tended to have rotational responses that were better correlated with trunk velocity. We conclude that sensory vestibular signals are transformed from head-in-space coordinates to trunk-in-space coordinates on many secondary vestibular neurons in the vestibular nuclei by the addition of inputs related to head rotation on the trunk. This coordinate transformation is presumably important for controlling postural reflexes and constructing a central percept of body orientation and movement in space.

Non-NASA Center↗

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE↗

Adaptive Optical Two-Photon Fluorescence Microscopy Probes Cellular Organization of Ocular Lenses In Vivo

The mammalian ocular lens is an avascular multicellular organ that grows continuously throughout life. Traditionally, its cellular organization is investigated using dissected lenses, which eliminates in vivo environmental and structural support. Therefore, in vivo optical imaging methods for studying lenses in their native context in live animals are urgently needed. Here, we demonstrated that two-photon fluorescence microscopy can visualize lens cells in vivo. To maintain subcellular resolution at depth, we used adaptive optics to correct aberrations owing to ocular and lens tissues, which led to substantial signal and resolution improvements. Imaging lens cells up to 980 µm deep, we observed novel cellular organizations including suture-associated voids, enlarged vacuoles, and large cavities, contrary to the conventional view of a highly ordered organization. We tracked these features longitudinally over weeks and observed the incorporation of new cells during growth. Taken together, noninvasive longitudinal in vivo imaging of lens morphology using adaptive optics two-photon fluorescence microscopy will allow us to observe the development or alterations of lens cellular organization in living animals directly.

60 APPLIED LIFE SCIENCES↗