Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Experiment-Based Verification of the SAFR/V1 Module of the EVKLID/V2 Integral Code for Thermal Breakdown of Fuel Pins in a Fast Reactor

The results of verification of the IBRAE-developed SAFR/V1 module, describing in the EVKLID/V2 integral code the thermal breakdown of fuel pins, on the basis of data obtained using experimental facilities. The experiments performed on the TREAT and DEH facilities at the Argonne National Laboratory and on a bench at the Nizhny Novgorod State Technical University were picked for the verification process. The computational error was evaluated for individual parameters on the basis of the verification results. The impact of the uncertainties in the initial data on the computational results was analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and validation of the open-source plasma fluid code: Zapdos

Zapdos is an open-source finite element plasma fluid solver based on the MOOSE multiphysics framework. This paper outlines Zapdos verification, benchmarking, and validation efforts for 1D and 2D RF capacitively coupled plasma discharge models for mid-range pressures (0.1 - 1 Torr). The verification process involved using the method of manufactured solutions to assess Zapdos spatial and temporal error convergence. L2 errors ranged from 10 -2 to 10 -4 , while the convergence’s slope were in agreement with the predicted slopes for the tested variable and time integration orders. The benchmarking process involved comparisons to previously results from the validated finite element code, LSODI. These works included 1D and 2D simulations for a range of plasma parameters (densities, temperatures, voltage, etc.). For the 1D cases, Zapdos and LSODI results were in very good agreement. In the 2D cases, variable behaviors matched, with slight discrepancies in peak values. The validation process involved comparisons to experimental works including electron density measurements by microwave interferometry and metastable density measurements by planar laser-induced fluorescence imaging. Results shown reasonable agreement at higher pressure, with results starting to diverge at low pressures. Furthermore, probable causes for this diverges are the limitation of the fluid assumption for plasmas at low pressure, or the need for more robust boundary conditions. Overall, Zapdos shown reasonable results for the verification, benchmarking, and validation efforts, and Zapdos can be downloaded at https://github.com/shannon-lab/zapdos.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and verification of dynamic field ionization for laser-target interactions

Integrating field ionization models into kinetic plasma simulations is required for a variety of applications, especially when field strengths vary from low to high regimes, such as in laser-target interactions. The introduction of new physics models into kinetic codes requires a rigorous verification of their accuracy through well-defined verification problems. In this work, the field ionization model that has been included in the kinetic plasma code VPIC is presented, along with the detailed approach adopted for its integration. This model includes a comprehensive range of field ionization mechanisms: multiphoton ionization, tunneling ionization, and barrier suppression ionization. New verification problems employed to evaluate the ionization model's fidelity are outlined, and the simulation parameters that affect the accuracy of simulation results are explored. Additionally, this work addresses the impact of field ionization on computational performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of Proton Beam Range Verification Using Post-Treatment Positron Emission Tomography/Computed Tomography as Function of Treatment Site

Purpose: For 23 patients, an off-line positron emission tomography scan and a computed tomography scan after proton radiotherapy was performed at the Massachusetts General Hospital to assess in vivo treatment verification. A well-balanced population of patients was investigated to assess the effect of the tumor location on the accuracy of the technique. Methods and Materials: Range verification was achieved by comparing the measured positron emission tomography activity distributions with the corresponding Monte Carlo-simulated distributions. Observed differences in the distal end of the activity distributions were analyzed as potential indicators for the range differences between the actual delivered and planned dose. Results: The average spatial agreement between the measured and simulated activity distribution was within {+-}3 mm, and the corresponding average absolute agreement was within {+-}45% (derived from gamma index analysis). The mean absolute range deviation at 93 randomly chosen positions in 17 treatment fields delivered to 11 patients was 3.6 mm. Characteristic differences in the agreement of the measured and simulated activity distribution for the different tumor/target sites were found. This resulted from the different effect of factors such as biologic washout effects, motion, or limitations in the Monte Carlo-simulated activity patterns. Conclusion: We found that intracranial and cervical spine patients can greatly benefit from off-line positron emission tomography and computed tomography range verification. However, for the successful application of the method to patients with abdominopelvic tumors, major technological and methodologic improvements are needed. Among the intracranial and cervical spine target sites, patients with arteriovenous malformations or metal implants represent groups that could especially benefit from the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging

Purpose: The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry–ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. Methods and Materials: A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. Results: In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. Conclusions: An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were −0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and −0.4 ± 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interprofessional Image Verification Workshop for Physician and Physics Residents: A Multi-Institutional Experience

Verification of patient position through pretreatment setup imaging is crucial in modern radiation therapy. As treatment complexity increases and technology evolves, physicist-physician collaboration becomes imperative for safe and successful radiation delivery. Despite the importance of both, residency programs lack formal interprofessional education (IPE) activities or structured training for image verification. Here we show the impact of an interprofessional image verification workshop for residents in a multi-institutional setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2D Dose Reconstruction by Artificial Neural Network for Pretreatment Verification of IMRT Fields

The use of intensity-modulated radiation therapy (IMRT) is developing rapidly in clinical routines. Because of the high complexity and uniqueness of IMRT treatment plans, patient-specific pretreatment quality assurance is generally considered a necessary prerequisite for patient treatment. In this work, we proposed a modified methodology of electronic portal imaging device (EPID)–based dose validation for pretreatment verification of IMRT fields by applying artificial neural networks (ANNs). The ANN must be trained and validated before use for pretreatment dose verification. For this purpose, 20 EPID fluence maps of IMRT prostate anterior-posterior fields were used as an input for ANN (feed forward type) and a dose map of those fluence maps that were predicted by treatment planning system as an output for ANN. After the training and validation of the neural network, the analysis of 10 IMRT prostate anterior-posterior fields showed excellent agreement between ANN output and dose map predicted by the treatment planning system. The average overall fields pass rate was 96.0% ± 0.1% with 3 mm/3% criteria. The results indicated that the ANN can be used as a low-cost, fast, and powerful tool for pretreatment dose verification, based on an EPID fluence map.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments

The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers are considered the gold standard because of their precision, availability, and relative ease of use. This study evaluates and compares 5 different ionization chambers: phantom combinations for verification in routine patient-specific quality assurance of RapidArc treatments. Fifteen different RapidArc plans conforming to the clinical standards were selected for the study. Verification plans were then created for each treatment plan with different chamber-phantom combinations scanned by computed tomography. This includes Medtec intensity modulated radiation therapy (IMRT) phantom with micro-ionization chamber (0.007 cm{sup 3}) and pinpoint chamber (0.015 cm{sup 3}), PTW-Octavius phantom with semiflex chamber (0.125 cm{sup 3}) and 2D array (0.125 cm{sup 3}), and indigenously made Circular wax phantom with 0.6 cm{sup 3} chamber. The measured isocenter absolute dose was compared with the treatment planning system (TPS) plan. The micro-ionization chamber shows more deviations when compared with semiflex and 0.6 cm{sup 3} with a maximum variation of -4.76%, -1.49%, and 2.23% for micro-ionization, semiflex, and farmer chambers, respectively. The positive variations indicate that the chamber with larger volume overestimates. Farmer chamber shows higher deviation when compared with 0.125 cm{sup 3}. In general the deviation was found to be <1% with the semiflex and farmer chambers. A maximum variation of 2% was observed for the 0.007 cm{sup 3} ionization chamber, except in a few cases. Pinpoint chamber underestimates the calculated isocenter dose by a maximum of 4.8%. Absolute dose measurements using the semiflex ionization chamber with intermediate volume (0.125 cm{sup 3}) shows good agreement with the TPS calculated among the detectors used in this study. Positioning is very important when using smaller volume chambers because they are more sensitive to geometrical errors within the treatment fields. It is also suggested to average the dose over the sensitive volume for larger-volume chambers. The ionization chamber-phantom combinations used in this study can be used interchangeably for routine RapidArc patient-specific quality assurance with a satisfactory accuracy for clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Establishing an optimized patient-specific verification program for volumetric modulated arc therapy

Quality assurance (QA) of volumetric modulated arc therapy (VMAT) increases the workload significantly. We compared the results from 4 verification methods to establish an efficient VMAT QA. Planning for VMAT treatments was carried out for 40 consecutive patients. Pretreatment verifications were carried out with ion chamber array Physikalish-Technische Werkstätten (PTW729), electronic portal dosimetry (EPID), ion chamber measurements, and independent dose calculation with Diamond program. 2D analyses were made using the gamma analysis (3 mm distance to agreement and 3% dose difference relative to maximum, 10% dose threshold). Average point dose difference calculated by Eclipse relative to ion chamber measurements and Diamond were 0.1%±0.9% and 0.6%±2.2%, respectively. Average pass rate for PTW729 was 99.2%±1.9% and 98.3%±1.3% for EPID. The total required time (linac occupancy time given in parentheses) for each QA method was: PTW729 43.5 minutes (26.5 minutes), EPID 14.5 minutes (2.5 minutes), ion chamber 34.5 minutes (26.5 minutes), and Diamond 12.0 minutes (0 minute). The results were consistent and allowed us to establish an optimized protocol, considering safety and accuracy as well as workload, consisting of 2 verification methods: EPID 2D analysis and independent dose calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification and validation for magnetic fusion

Dramatic progress in the scope and power of plasma simulations over the past decade has extended our understanding of these complex phenomena. However, as codes embody imperfect models for physical reality, a necessary step toward developing a predictive capability is demonstrating agreement, without bias, between simulations and experimental results. While comparisons between computer calculations and experimental data are common, there is a compelling need to make these comparisons more systematic and more quantitative. Tests of models are divided into two phases, usually called verification and validation. Verification is an essentially mathematical demonstration that a chosen physical model, rendered as a set of equations, has been accurately solved by a computer code. Validation is a physical process which attempts to ascertain the extent to which the model used by a code correctly represents reality within some domain of applicability, to some specified level of accuracy. This paper will cover principles and practices for verification and validation including lessons learned from related fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum money with classical verification

We propose and construct a quantum money scheme that allows verification through classical communication with a bank. This is the first demonstration that a secure quantum money scheme exists that does not require quantum communication for coin verification. Our scheme is secure against adaptive adversaries - this property is not directly related to the possibility of classical verification, nevertheless none of the earlier quantum money constructions is known to possess it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Warhead verification as inverse problem: Applications of neutron spectrum unfolding from organic-scintillator measurements

Verification of future warhead-dismantlement treaties will require detection of certain warhead attributes without the disclosure of sensitive design information, and this presents an unusual measurement challenge. Neutron spectroscopy—commonly eschewed as an ill-posed inverse problem—may hold special advantages for warhead verification by virtue of its insensitivity to certain neutron-source parameters like plutonium isotopics. In this article, we investigate the usefulness of unfolded neutron spectra obtained from organic-scintillator data for verifying a particular treaty-relevant warhead attribute: the presence of high-explosive and neutron-reflecting materials. Toward this end, several improvements on current unfolding capabilities are demonstrated: deuterated detectors are shown to have superior response-matrix condition to that of standard hydrogen-base scintintillators; a novel data-discretization scheme is proposed which removes important detector nonlinearities; and a technique is described for re-parameterizing the unfolding problem in order to constrain the parameter space of solutions sought, sidestepping the inverse problem altogether. These improvements are demonstrated with trial measurements and verified using accelerator-based time-of-flight calculation of reference spectra. Then, a demonstration is presented in which the elemental compositions of low-Z neutron-attenuating materials are estimated to within 10%. These techniques could have direct application in verifying the presence of high-explosive materials in a neutron-emitting test item, as well as other for treaty verification challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Drift Flux Model into SAM with Development of a Verification and Validation Test Suite for Modeling of Noncondensable Gas Mixtures

The advanced thermal-hydraulic system code, System Analysis Module (SAM), was originally developed for the modeling of single-phase flow in advanced reactors. It has since been expanded to include a four-equation drift flux model for the modeling of two-phase flows containing a noncondensable gas. The model was expanded to support the modeling of molten salt reactor (MSR) designs in which the fuel is directly dissolved in the circulating coolant. These designs have shown that circulating gas bubbles can play an important role in the management of fission products and the operational behavior of the reactor. A drift flux model was implemented to more accurately capture the localized behavior of the void in the core and its impact on the mass transfer of fission products. A thorough assessment of the new model was performed by developing a verification and validation test suite. Verification problems were designed to test all major terms in the new governing equations. The new model converged to the correct solution at the expected order of accuracy for all verification cases. The validation cases included a wide range of flow and void conditions in different pipe geometries. Although higher void experiments show a slight underprediction of void by the drift flux model, experiments that aim to reproduce Molten Salt Reactor Experiment (MSRE) experimental conditions show good agreement with the model. The gas transport model was activated for a SAM model of the MSRE to demonstrate that it can be used in a more complex model. Finally, this gas transport model will be used along with an interfacial area transport equation being implemented in SAM for the prediction of mass transport behavior in MSR conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗