Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Wilson Corners SWMU 001 2015 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2015 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration John F. Kennedy Space Center, Florida. The objectives of the 2015 LTM event were to evaluate the groundwater flow direction and gradient, to monitor the vertical and horizontal extent of the volatile organic compounds (VOCs; including the upgradient and sidegradient extents, which are monitored every five years), and to monitor select locations internal to the dissolved groundwater plume. The 2015 LTM event included several upgradient and sidegradient monitoring wells that are not sampled annually to verify the extent of VOCs in this portion of the site. The December 2015 LTM groundwater sampling event included, depth to groundwater measurements, 40 VOC samples collected using passive diffusion bags, and one VOC sample collected using low-flow techniques. Additionally, monitoring well MW0052DD was overdrilled and abandoned using rotasonic drilling techniques. The following conclusions can be made based on the 2015 LTM results: groundwater flow is generally to the west with northwest and southwest flow components from the water table to approximately 55 feet below land surface (ft BLS); peripheral monitoring wells generally delineate VOCs to groundwater cleanup target levels (GCTLs) except for monitoring wells MW0088, MW0090, MW0095, and NPSHMW0039, which had vinyl chloride (VC) concentrations near the GCTL and MW0062, which had trichloroethene (TCE), cis-1,2-dichloroethenen (cDCE), and VC concentrations above natural attenuation default concentrations (NADCs); VOCs in interior downgradient wells generally fluctuate within historic ranges except for monitoring wells in the north-northwest portion of the site, which have increasing VC concentrations indicating potential plume migration and expansion; Historically, the vertical extents of the VOCs were delineated by monitoring wells screened greater than 60 ft BLS (MW0083 through MW0086, and MW0078). The 2015 LTM results indicate that concentrations of daughter product cDCE is greater than the NADC in MW0078 and that cDCE and VC are greater than NADCs in MW0130. TCE was greater than the GCTL in monitoring well MW130 and not detected above method detection limits (9 micrograms per Liter) in monitoring well MW0078. No GCTL exceedances were identified in monitoring wells MW0083 or MW0086; the dissolved plume footprint appears generally stable, though not fully delineated by monitoring well data in the northeast portion of the site; and 2015 LTM results generally support the existing Conceptual Site Model. Geosyntec recommends modifying the LTM program, collecting a verification sample from monitoring well MW0062, and performing a direct push technology instigation in the northnortheastern portion of the site. A cluster of monitoring wells (MW0132 [2 to 12 ft BLS], MW0133 [15 to 25 ft BLS], and MW0134 [29 to 34 ft BLS]) is proposed to delineate impacts in the northnortheast portion of the site. Geosyntec recommends installation of a vertical extent well in the center of the site (Hot Spot 2 area) post-remediation implementation.

groundwater↗

The Origin of Carbon-bearing Volatiles in Surprise Valley Hot Springs in the Great Basin: Carbon Isotope and Water Chemistry Characterizations

There are numerous hydrothermal fields within the Great Basin of North America, some of which have been exploited for geothermal resources. With methane and other carbon-bearing compounds being observed, in some cases with high concentrations, however, their origins and formation conditions remain unknown. Thus, studying hydrothermal springs in this area provides us an opportunity to expand our knowledge of subsurface (bio)chemical processes that generate organic compounds in hydrothermal systems, and aid in future development and exploration of potential energy resources as well. While isotope measurement has long been used for recognition of their origins, there are several secondary processes that may generate variations in isotopic compositions: oxidation, re-equilibration of methane and other alkanes with CO2, mixing with compounds of other sources, etc. Therefore, in addition to isotopic analysis, other evidence, including water chemistry and rock compositions, are necessary to identify volatile compounds of different sources. Surprise Valley Hot Springs (SVHS, 41 deg 32'N, 120 deg 5'W), located in a typical basin and range province valley in northeastern California, is a terrestrial hydrothermal spring system of the Great Basin. Previous geophysical studies indicated the presence of clay-rich volcanic and sedimentary rocks of Tertiary age beneath the lava flows in late Tertiary and Quaternary. Water and gas samples were collected for a variety of chemical and isotope composition analyses, including in-situ pH, alkalinity, conductivity, oxidation reduction potential (ORP), major and trace elements, and C and H isotope measurements. Fluids issuing from SVHS can be classified as Na-(Cl)-SO4 type, with the major cation and anion being Na+ and SO4(2-), respectively. Thermodynamic calculation using ORP and major element data indicated that sulfate is the most dominant sulfur species, which is consistent with anion analysis results. Aquifer temperatures at depth estimated by both dissolved SiO2 and Na-K-Ca geothermometers are in the range of 125.0 to 135.4 C, and higher than the values measured at orifices (77.3 to 90.0 C). CO2 and homologs of straight chain alkanes (C1-C5) were identified in gas samples. Carbon isotope values of alkanes increase with carbon numbers. The C-13 fractionation between CO2 and dissolved inorganic carbon suggests they are out of carbon isotope equilibrium. The hypothesis regarding the formation of carbon-bearing compounds in SVHS may involve two processes: 1) Under high heat flow conditions which are caused by regional faulting and crustal extension, original high molecular weight organic compounds (kerogens) in clay-rich rocks decomposed to generate methane and other alkane homologs. 2) The SVHS area is associated with outflow structures, and distant from the heat source. Anaerobic oxidation of methane (AOM) with sulfate at shallow depth (< 90 C) is suggested as being responsible for the generation of CO2 in SVHS.

Fu, Qi↗

Lessons Learned from Particulate Characterization Laboratory Anomalies

The White Sands Test Facility chemistry laboratory provides quality control for cleanroom operations including cleanliness verification of aerospace hardware by particulate counts and non-volatile residue determinations, particulate counts for liquid hypergolic propellants, gaseous helium and nitrogen propellant pressurizing agents used for ground support equipment and flight test article valve actuation, gaseous oxygen primarily used for component testing, and deionized water for refurbished propellant hardware flushing. Cleanliness verification includes particulate counts and non-volatile residue determinations to industry standard, NASA, and program specifications and levels. Particulate counts are typically to customer-specified specifications and levels including JPR 5322.1H (2016) Levels 50 and 100, Orion (MPCV 70156. Revision H (2018)) Level 100, RPTSTD-8070-0001 Revision 3 (2022), and IEST-STD-CC1246E (2013) Levels 50 and 100. The laboratory issues high pressure filter holders containing membrane filters to test operations personnel, who collect samples by flowing the required volumes of fluid through the filter holder, and the filter holder is returned to the lab for counting. A passing particulate count is required before testing may proceed. Rapid data reduction and issuing of reports indicating a pass or fail of the particulate specification are required. Corrective action and resampling invariably occurs if a sample fails. Consequently, the laboratory must maintain the highest degree of reliability to facilitate quality data used to decide if testing may proceed. Experience and continual improvements have enabled reliability. However, anomalies attributed to lab processes and hardware including filter holders, membranes, and Petri dishes have been encountered. This paper presents a summary of problems, solutions, successes, and lessons learned from particle counting experience for over 35 years.

Lessons Learned↗

The H2o Content of the Ureilite Parent Body

The fate of highly volatile elements (H, C, F, Cl and S) during planetary accretion and differentiation is debated. Recent analyses of water in non-carbonaceous chondrites (RC, OC, EC) and achondrites (angrites, eucrites) have been used to argue that inner solar system parent bodies accreted and retained their highly volatile element budgets from their primary feedstock without substantial loss during accretion, metamorphism and differentiation. An alternative model posits that differentiated inner solar system parent bodies (e.g., the angrite parent body, 4 Vesta, Earth) derived the majority of their water from a carbonaceous chondrite-like source, delivered during the final stages of accretion. In order to add new constraints to this debate, we have measured water in nominally anhydrous minerals, melt inclusions, and interstitial glass in ureilites, the largest group of primitive achondrites in the terrestrial meteorite collection. Primitive achondrites did not experience global melting and homogenization. Therefore, these meteorites capture part of the transition from chondritic to achondritic parent bodies, allowing us to constrain the fate of water during the earliest stages of differentiation. Our nano-scale secondary ion mass spectrometry (nanoSIMS) analyses allow us to assess the viability of ureilite-like material as a potential source of terrestrial water. Analyses of pigeonite in main group ureilites yield a range of 2.0 – 6.0 µg/g H2O, and analyses of high-Ca pyroxene and glass (glassy melt inclusions and interstitial glass) in the Almahata Sitta ureilitic trachyandesite yield ranges of 13 – 19 µg/g H2O and 44 – 216 µg/g H2O, respectively. Mass balance, incremental melting, and batch melting calculations yield a preferred ureilite parent body H2O content of 2 – 20 µg/g, similar to previous estimates of water in the eucrite parent body (4 Vesta), but lower than estimates of Earth’s water budget. With these data, we demonstrate that 1) the ureilite parent body is H2O-depleted relative to the Earth; 2) ureilite-like material is unlikely to be a primary source of H2O to the Earth; 3) C and H are not necessarily coupled elements during planetary accretion and thermal processing; and 4) accretion, heating, partial melting, and degassing of rocky planetesimals likely results in significant depletion of H2O.

Primitive achondrites↗

Chronology of Accessory Phases in Lunar Meteorite Northwest Africa 12593

Lunar meteorites are complementary to the suite of rock and regolith samples collected by the Apollo missions. While the Apollo samples represent the most pristine material we have from the Moon, lunar meteorites represent a more global sampling of the lunar crust, albeit without geologic context [e.g. 1]. As such, lunar meteorites are important for understanding the composition of the lunar crust and the processes responsible for its formation and evolution. This work aims to understand the observed differences in accessory phase chronology and volatile chemistry between lunar meteorites and Apollo rocks. For example, apatite ages in Apollo samples range from ~3.83 to 4.28 Ga [e.g. 2, 3], while apatites in lunar meteorites range from ~3.00 to 4.44 Ga [e.g. 4, 5]. Additionally, a much larger range of Cl isotope compositions and concentrations is observed in lunar meteorites as compared to Apollo samples[e.g. 6]. It has recently been shown that impact metamorphism can influence both chronology and chemistry of phosphates [e.g. 7, 8]. Here we present the first chronologic results from a consortium study pairing chronology, volatile chemistry, and crystal structure of apatites in a lunar breccia meteorite. The results of this work will help inform interpretation of ongoing analyses of apatites separated from Apollo soils. Note: Extended abstract on document.

C. A. Crow↗

Plasma Abatement of Volatile Organic Compounds

One difficulty with crewed space operations is the potential for the contamination of the spacecraft habitable volume from volatile organic compounds (VOCs) that may be present. One possible VOC abatement process is to apply a plasma to the contaminated gases. Plasmas provide high energy electrons and ions that are capable of breaking down gaseous organic species generally into smaller compounds. To explore plasma VOC abatement, the authors constructed a plasma gas system that recirculates a particular VOC-laden gas mixture through a plasma torch. This allows for the periodic collection of aliquots of gaseous samples for subsequent analyses via gas chromatography mass spectrometry, designed to quantify the remaining VOC materials. The VOCs evaluated included 100 ppm of acetone, benzene, ethanol, and pentane in a background of carbon dioxide. The plasma conversion of all analytes followed first-order rate kinetics, and VOC elimination was observed after 10 min or less of treatment for all analytes measured. Additionally, it was observed that the plasma caused the conversion of CO 2 into oxygen and CO.

Joel A. Olson↗

An ET Origin for Stratospheric Particles Collected during the 1998 Leonids Meteor Shower

On 17 November 1998, a helium-filled weather balloon was launched into tfle strato- sphere, equipped with a xerogel microparticle collector. The three-hour flight was designed to sample the dust environment in the stratosphere during the Leonid meteor shower, and possibly to capture Leonid meteoroids. Environmental Scanning Election Microscope analyses of the returned collectors revealed the capture of a -30-pm particle. with a smooth, multigranular shape, and partially melted, translucent rims; similar to known Antarctic micrometeorites. Energy-dispersive X-ray Mass Spectroscopy shows en- riched concentrations of the non-volatile elements, Mg, Al, and Fe. The particle possesses a high magnesium to iron ratio of 2.96, similar to that observed in 1998 Leonids meteors (Borovicka, et al. 1999) and sharply higher than the ratio expected for typical material from the earth's crust. A statistical nearest-neighbor analysis of the abundance ratios Mg/Si, Al/Si, and Fe/Si demonstrates that the particle is most similar in composition to cosmic spherules captured during airplane flights throucrh the stratosphere. The mineralogical class is consistent with a stony (S) type of silicates. olivine [(Mg, Fe)2SiO4] and pyroxene [(Mg,Fe)SiO3]-or oxides, herecynite [(Fe,Mg) Al2O4]. Attribution to the debris stream of the Leonids' parent body, comet Tempel-Tuttle, would make it the first such material from beyond the orbit of Uranus positively identified on Earth.

Noever, David A.↗

Well-to-wheels greenhouse gas and air pollutant emissions from battery electric vehicles in China

Electric vehicles (EVs) play a crucial role in addressing climate change and urban air quality concerns. China has emerged as the global largest EV market with 1.2 million EVs sold in 2018. This study established a novel life cycle energy use and emission inventory collecting up-to-date data including the electricity generation mix, emission controls in the power and industrial sectors, and the energy use in the fuel transport to estimate the well-to-wheels (WTW) greenhouse gas (GHG), and air pollutant emissions for battery electric vehicles (BEVs) and gasoline passenger vehicles in China. The results show that an average BEV has 35% lower WTW GHG emissions than an average gasoline car. BEVs reduce volatile organic compounds (VOCs) and nitrogen oxides (NOX) emissions by 98% and 34%, respectively, but have comparable or slightly higher primary fine particulate matter (PM2.5) and sulfur dioxide (SO2) emissions. Compact and small-size vehicles generally have lower GHG and air pollutant emissions than mid- and large-size vehicles. Class A vehicles contribute the most in the absolute amount of GHG and air pollutant emissions and therefore have the biggest potential for emission reduction. Our results suggest that global policymakers should continue to promote the transition to clean power sources, emission control, and fuel economy regulations, which are critical to enhancing emission mitigation benefits of BEVs. We also suggest EV development strategies should be formulated targeting vehicle class with the biggest emission mitigation potentials.

Air pollutant emissions↗

Cometary dust: A thermal criterion to identify cometary samples among the collected interplanetary dust

The relative proportions of the cometary and the asteroidal contributions to the interplanetary dust have not yet been definitively established. These proportions may vary with time as a result of major catastrophic disruptions in the main belt or the appearance of fresh, active comets. Dermott et al. and Reach suggest the debris from catastrophic collisions in the main belt can account for most of the zodiacal cloud particles. Earth collection of these asteroidal particles is strongly favored by near-Earth gravitational enhancement. However, comets are observed to produce interplanetary dust particles (IDP's), and the identification of cometary IDP's would allow inferences of the compositions, mineralogies, and physical properties of the comets. The peak temperatures reached by IDP's on atmospheric entry indicate the distribution of IDP velocities. Each IDP contains many internal thermometers: minerals that transform above certain temperatures, volatile elements that are lost sequentially with increasing temperatures, solar flare tracks that anneal at different temperatures in different minerals, and solar-implanted noble gases that outgas progressively with temperature. Thus, limits on the peak temperature reached by each IDP on Earth atmospheric entry can be set. Other aspects of this investigation are covered.

Flynn, George J.↗

Plasma Abatement of Volatile Organic Compounds for Treatment of Spacecraft Trash Combustion Gaseous Effluents.

One approach that has been investigated for trash management aboard long-duration crewed exploration space missions is the so-called Trash-to-Gas approach. This technology uses a thermal process (i.e., combustion, pyrolysis, etc.) to convert crew trash into relatively non-reactive gases (i.e., CO2, CO, etc.) that can be easily vented overboard. One difficulty with this approach is the potential for the contamination of the spacecraft habitable volume from the myriad volatile organic compounds (VOCs) that are concurrently produced from these thermal processes. One possible VOC abatement process is to apply a plasma to the effluent gases. Plasmas provide high energy electrons and ions that are capable of breaking down gaseous organic species generally into smaller compounds. To explore Plasma VOC abatement, the authors constructed a plasma gas system that recirculates a particular VOCladen gas mixture through a plasma torch. This allows the periodic collection of aliquots of gaseous samples for subsequent analyses via gas chromatography mass spectrometry, designed to quantify the remaining VOC materials. The VOCs evaluated included 100 ppm of acetone, benzene, ethanol, and pentane in a background of carbon dioxide. The plasma conversion of all analytes followed first order rate kinetics, and complete VOC elimination was observed after 10 min or less of treatment, for all analytes measured. Additionally, it was observed that the plasma caused the conversion of CO2 into oxygen and CO.

Joel A. Olson↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

Gas Effluent Analysis of the Heat Melt Compactor

The Heat Melt Compactor (HMC) reduces volume, heat sterilizes, stabilizes, and manages gas and water effluent of the International Space Station (ISS) trash. Processing the trash at high temperatures produces volatile gas compounds that need to be treated before venting to cabin and/or the Vacuum Exhaust System (VES) in the ISS. The release of gases may not meet the Spacecraft Maximum Allowable Concentrations (SMAC) requirement, if vented directly into cabin, and/or gases are incompatible for venting to the VES. In order to assess the HMC gas release and venting parameters, effluent gas analysis is conducted to determine contaminant load. This paper will analyze different collection and analytical methods of the effluent gas, and report corresponding data, such that these results can be used for process design and effluent management.

Heat Melt Compactor↗

Evidence for a Thick Mantle of Volatile-rich Materials in the Utopia Basin, Mars, Based on Crater Depth/Diameter Measurements

This study focuses on the depth/diameter (d/D) relationships of impact craters within Utopia Basin (25 deg. N - 70 deg. N, 88 deg. W - 150 deg. W), Mars. In order to search for spatial variations in the study area, d/D values for a total of 1,430 craters have been grouped by sub-regions based upon their similar d/D characteristics. This has revealed a significant difference in d/D relationship for craters in north central Utopia basin compared with other parts of the basin, and withother areas on Mars. Preliminary measurements have also been collected in four additional test areas (Acidalia, Sinai, Sirenum, and south of Argyre) for comparison purposes.

Boyce, Joseph M.↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

Glavin, D. P.↗

General Services Administration Reclamation Yard, SWMU 010, 2021 Groundwater Monitoring Report

This report presents a summary of the groundwater monitoring activities that occurred in November and December 2021 at General Services Administration Reclamation Yard, Solid Waste Management Unit 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, two separate plumes, known as the Polychlorinated Biphenyl (PCB)/Volatile Organic Aromatic (VOA) Plume and the Chlorinated Volatile Organic Compound (VOC) Plume, were identified for this site. The contaminants of concern (COCs) for the PCB/VOA Plume consists of PCBs, 1,2,4-trichlorobenzene, and breakdown products of 1,2,4-trichlorobenzene. The COCs for the Chlorinated VOC Plume are tetrachloroethene, trichloroethene, cis-1,2-dichloroethene, and vinyl chloride. The activities presented in this report include two field events: (1) November 2021 – PCB/VOA Plume groundwater sampling via Direct Push Technology – 70 groundwater samples were collected from 10 locations at varying intervals; and (2) December 2021 – Site-wide semi-annual water level measurements of 54 monitoring wells, redevelopment of 5 monitoring wells, and sampling of 35 monitoring wells. Results for the PCB/VOA plume demonstrated COCs have not rebounded since the 2018 source removal, with groundwater cleanup target levels (GCTLs) exceeded in the 10-30 ft. below ground surface interval only. In the Chlorinated VOC plume area, there were no detections of COCs above a GCTL for at least the second consecutive sampling event for the sampled wells. Cleanup objectives have been met, and it is recommended that VOC monitoring be discontinued. Underground injection control parameters will continue to be monitored in three wells until those analytes return to background concentrations.

GSA Reclamation Yard↗

Simulating Ordinary Chondrite (Tamdakht) Ablation at the Hypersonic Materials Environmental Test System (HyMETS) Facility.

NASA’s Science Mission Directorate (SMD) created the Asteroid Threat Assessment Project (ATAP) to inform decision-makers of risks associated with Potentially Hazardous Objects (PHOs), which may pose an existential threat to human civilization. ATAP assesses risk, in part, by developing analytical physics-based damage models which draw upon data collected during material property characterization efforts, entry simulations, hazard simulations, and ground-based arc-jet testing. Therefore, a pathfinder test campaign was con-ducted at the Hypersonic Materials Environmental Test System (HyMETS) at the NASA Langley Re-search Center to investigate the ablation mechanisms of an ordinary chondrite (Tamdakht H5) and a terrestrial analog (basalt). The HyMETS facility is a 400 kW constricted arc heater used to screen material performance under simulated aerothermal conditions of hypersonic flow.1 Facility conditions were chosen to simulate Earth entry conditions be-tween the upper-mesosphere and the lower thermo-sphere. The ablation mechanisms of Tamdakht and bas-alt are illustrated with still images collected from high-speed video cameras (fig. 1, Tamdakht). Tamdakht produces a relatively stable melt flow, as evidenced by the perpetual growth of a flange at the sidewall and the exiguous detachment of molten material into the flow. Furthermore, an inspection of high-speed video and chemical analysis of the post-test melt layer suggests that the dominant mode of mass loss for Tamdakht, at these test conditions, is expressed through the vaporization of volatiles (e.g., iron, potassium, sodium, phosphorus, and sulfur). The vaporization rates of Tamdakht are greater than basalt under the most extreme test conditions, which leads to an enhanced blowing layer, in-creased thermal shielding, and reduced recession. The ablation mechanisms of basalt are markedly different from Tamdakht and are attributed to the presence of hydrated minerals dispersed at irregular intervals throughout the silicate matrix. Rapid de-composition of secondary minerals and the subsequent formation of water lead to the ejection of the subsurface and overlying melt layer. Furthermore, the presence of water is suspected of lowering the viscosity of the melt layer resulting in increased mass loss near the edge of the test article where drag forces overcome rheological properties (fig. 1, bas-alt). Finally, the results will be discussed in the broader context of meteorite-based material response model development and the potential impact on the Asteroid Threat Assessment Project (ATAP).

Brody K. Bessire↗

General Services Administration Reclamation Yard (SWMU 010) 2020-2021 Groundwater Monitoring Report

This report presents a summary of the groundwater monitoring activities that occurred from October 2020 through June 2021 at General Services Administration Reclamation Yard, Solid Waste Management Unit 010, located at the John F. Kennedy Space Center (KSC), Florida. For the purposes of this report, two separate plumes, known as the Polychlorinated Biphenyl (PCB)/Volatile Organic Aromatic (VOA) Plume and the Chlorinated Volatile Organic Compound (VOC) Plume were identified for this site. The contaminants of concern (COCs) for the PCB/VOA Plume consists of PCBs, 1,2,4-trichlorobenzene, and breakdown products of 1,2,4-trichlorobenzene. The COCs for the Chlorinated VOC Plume are tetrachloroethene, trichloroethene, cis-1,2-dichloroethene, and vinyl chloride. The activities presented in this report include four field events: (1) October 2020 – Chlorinated VOC Plume groundwater sampling via Direct Push Technology (DPT) – 68 groundwater samples were collected from 14 locations at varying intervals; (2) December 2020 – Site-wide semi-annual water level measurements of 52 monitoring wells and sampling of 39 monitoring wells; (3) May 2021 – Chlorinated VOC Plume monitoring well installation – two monitoring wells were installed and screened from 10 to 20 feet below land surface (bls); and (4) May/June 2021 – Site-wide semi-annual water level measurements of 53 monitoring wells and sampling of 40 monitoring wells. Results showed substantial reduction of both plumes. Conclusions and recommendations are presented.

VOC↗