Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Cosmic Shear Analysis of the DECam Local Volume Exploration Survey

We forecast cosmological constraints and develop a cosmic shear analysis pipeline for the DECam Local Volume Exploration Survey (DELVE). We test the effects of two different intrinsic alignment frameworks (TATT and NLA) on synthetic data vectors. In addition, we examine the impact of baryon contamination and determine the necessary scale cuts to reduce its influence. We find the forecast results to be as constraining as the DES Y3 cosmological parameter measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposed Rectal Dose Constraints for Patients Undergoing Definitive Whole Pelvic Radiotherapy for Clinically Localized Prostate Cancer

Purpose: Although several institutions have reported rectal dose constraints according to threshold toxicity, the plethora of trials has resulted in multiple, confusing dose-volume histogram recommendations. A set of standardized, literature-based constraints for patients undergoing whole pelvic radiotherapy (RT) for prostate cancer would help guide the practice of prostate RT. The purpose of this study was to develop these constraints, demonstrate that they are achievable, and assess the corresponding rectal toxicity. Methods and Materials: An extensive literature search identified eight key studies relating dose-volume histogram data to rectal toxicity. A correction factor was developed to address differences in the anatomic definition of the rectum across studies. The dose-volume histogram constraints recommended by each study were combined to generate the constraints. The data from all patients treated with definitive intensity-modulated RT were then compared against these constraints. Acute rectal toxicity was assessed. Results: A continuous, proposed rectal dose-constraint curve was generated. Intensity-modulated RT not only met this constraint curve, but also was able to achieve at least 30-40% lower dose to the rectum. The preliminary clinical results were also positive: 50% of patients reported no acute bowel toxicity, 33% reported Grade 1 toxicity, and 17% reported Grade 2 toxicity. No patients reported Grade 3-4 acute rectal toxicity. Conclusions: In this study, we developed a set of proposed rectal dose constraints. This allowed for volumetric assessment of the dose-volume relationship compared with single dose-volume histogram points. Additional research will be performed to validate this threshold as a class solution for rectal dose constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inflationary spectra with inverse-volume corrections in loop quantum cosmology and their observational constraints from Planck 2015 data

We first derive the primordial power spectra, spectral indices and runnings of both scalar and tensor perturbations of a flat inflationary universe to the second-order approximations of the slow-roll parameters, in the framework of loop quantum cosmology with the inverse-volume quantum corrections. This represents an extension of our previous work in which the parameter σ was assumed to be an integer, where σ characterizes the quantum corrections and in general can take any of values from the range σ element of (0, 6]. Restricting to the first-order approximations of the slow-roll parameters, we find corrections to the results obtained previously in the literature, and point out the causes for such errors. To our best knowledge, these represent the most accurate calculations of scalar and tensor perturbations given so far in the literature. Then, fitting the perturbations to the recently released data by Planck (2015), we obtain the most severe constraints for various values of σ. Using these constraints as our referring point, we discuss whether these quantum gravitational corrections can lead to measurable signatures in the future cosmological observations. We show that, depending on the value of σ, the scale-dependent contributions to the relativistic inflationary spectra due to the inverse-volume corrections could be well within the range of the detectability of the forthcoming generations of experiments, such as the Stage IV experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Rectal Dose-Volume Histogram Parameters Are Associated With Long-Term Patient-Reported Gastrointestinal Quality of Life After Conventional and High-Dose Radiation for Prostate Cancer: A Subgroup Analysis of a Randomized Trial

Purpose: We examined whether rectal dose-volume histogram (DVH) parameters were associated with long-term patient-reported gastrointestinal (GI) quality of life (QOL) after conventional (70.2 GyE) or high-dose (79.2 GyE) radiation for prostate cancer. Methods and Materials: Of 64 men with localized prostate cancer alive with a minimum 7-year follow-up after treatment as part of a randomized trial with either 70.2 GyE or 79.2 GyE of external beam radiation at Massachusetts General Hospital, 56 men (88%) returned a QOL questionnaire, and 50 of those men had DVH information. The DVH parameters of the anterior rectal wall were correlated with patient-reported long-term GI QOL using Pearson correlation and t tests. Results: There was a trend toward an association between increased long-term GI dysfunction and higher V60 (p = 0.07), V65 (p = 0.06), V70 (p = 0.09), and V75 (p = 0.09). When dichotomized by their medians, a V60 > 54% (p = 0.04), V70 > 44% (p = 0.06), and V75 > 39% (p = 0.06) were associated with increased long-term GI dysfunction. There was no difference in long-term GI dysfunction between men on the conventional vs. high-dose arms (p = 0.49). Conclusions: Dose-volume histogram parameters of the anterior rectal wall were associated with long-term patient-reported GI QOL after prostate radiation, whereas the dose prescribed to the prostate was not, suggesting that DVH constraints, rather than total prescribed dose, may have the greatest impact on long-term bowel dysfunction, and therefore that continued dose escalation may be feasible if appropriate dose-volume constraints are met.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical Constraints on Geologic CO2 Sequestration in Low-Volume Basalt Formations

Deep basalt formations within large igneous provinces have been proposed as target reservoirs for carbon capture and sequestration on the basis of favorable CO2-water-rock reaction kinetics that suggest carbonate mineralization rates on the order of 102–103 d. Although these results are encouraging, there exists much uncertainty surrounding the influence of fracture-controlled reservoir heterogeneity on commercial-scale CO2 injections in basalt formations. This work investigates the physical response of a low-volume basalt reservoir to commercial-scale CO2 injections using a Monte Carlo numerical modeling experiment such that model variability is solely a function of spatially distributed reservoir heterogeneity. Fifty equally probable reservoirs are simulated using properties inferred from the deep eastern Snake River Plain aquifer in southeast Idaho, and CO2 injections are modeled within each reservoir for 20 yr at a constant mass rate of 21.6 kg s–1. Results from this work suggest that (1) formation injectivity is generally favorable, although injection pressures in excess of the fracture gradient were observed in 4% of the simulations; (2) for an extensional stress regime (as exists within the eastern Snake River Plain), shear failure is theoretically possible for optimally oriented fractures if Sh is less than or equal to 0.70SV; and (3) low-volume basalt reservoirs exhibit sufficient CO2 confinement potential over a 20 yr injection program to accommodate mineral trapping rates suggested in the literature.

99 GENERAL AND MISCELLANEOUS↗

THE IMPLICATIONS OF GUNN-PETERSON TROUGHS IN THE He II Lyalpha FOREST

Many experts believe that the z approx 3 He II Lyalpha forest will suffer from the same saturation issues as the z approx 6 H I Lyalpha forest and, therefore, will not be a sensitive probe of He II reionization. However, there are several factors that make He II Lyalpha absorption more sensitive than H I Lyalpha. We show that observations of He II Lyalpha and Lybeta Gunn-Peterson troughs can provide a relatively model-independent constraint on the volume-averaged He II fraction of x{sub HeII,V}approx>0.1. This bound derives from first using the most underdense regions in the He II forest to constrain the local He II fraction and, then, assuming photoionization equilibrium with the maximum allowed photoionization rate to calculate the ionization state of nearby gas. It is possible to evade this constraint by a factor of approx2, but only if the He II were reionized recently. We argue that He II Lyalpha Gunn-Peterson troughs observed in the spectra of Q0302-003 and HE2347-4342 signify the presence of approx>10 comoving Mpc patches in which x{sub HeII,V}>0.03. This is a factor of 20 improvement over previous constraints from these spectra and 100 times stronger than the tightest constraint on the H I volume-filling fraction from the z > 6 H I Lyman forest.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scheduling Results for the THEMIS Observation Scheduling Tool

We describe a scheduling system intended to assist in the development of instrument data acquisitions for the THEMIS instrument, onboard the Mars Odyssey spacecraft, and compare results from multiple scheduling algorithms. This tool creates observations of both (a) targeted geographical regions of interest and (b) general mapping observations, while respecting spacecraft constraints such as data volume, observation timing, visibility, lighting, season, and science priorities. This tool therefore must address both geometric and state/timing/resource constraints. We describe a tool that maps geometric polygon overlap constraints to set covering constraints using a grid-based approach. These set covering constraints are then incorporated into a greedy optimization scheduling algorithm incorporating operations constraints to generate feasible schedules. The resultant tool generates schedules of hundreds of observations per week out of potential thousands of observations. This tool is currently under evaluation by the THEMIS observation planning team at Arizona State University.

Thermal Emission Imaging System (THEMIS)↗

A geometric representation scheme suitable for shape optimization

A geometric representation scheme is outlined which utilizes the natural design variable concept. A base configuration with distinct topological features is created. This configuration is then deformed to define components with similar topology but different geometry. The values of the deforming loads are the geometric entities used in the shape representation. The representation can be used for all geometric design studies; it is demonstrated here for structural optimization. This technique can be used in parametric design studies, where the system response is defined as functions of geometric entities. It can also be used in shape optimization, where the geometric entities of an original design are modified to maximize performance and satisfy constraints. Two example problems are provided. A cantilever beam is elongated to meet new design specifications and then optimized to reduce volume and satisfy stress constraints. A similar optimization problem is presented for an automobile crankshaft section. The finite element method is used to perform the analyses.

Tortorelli, Daniel A.↗

A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas

Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, and IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.

60 APPLIED LIFE SCIENCES↗

A feasibility study of dynamic adaptive radiotherapy for nonsmall cell lung cancer

Purpose: The final state of the tumor at the end of a radiotherapy course is dependent on the doses given in each fraction during the treatment course. This study investigates the feasibility of using dynamic adaptive radiotherapy (DART) in treating lung cancers assuming CBCT is available to observe midtreatment tumor states. DART adapts treatment plans using a dynamic programming technique to consider the expected changes of the tumor in the optimization process. Methods: DART is constructed using a stochastic control formalism framework. It minimizes the total expected number of tumor cells at the end of a treatment course, which is equivalent to maximizing tumor control probability, subject to the uncertainty inherent in the tumor response. This formulation allows for nonstationary dose distributions as well as nonstationary fractional doses as needed to achieve a series of optimal plans that are conformal to the tumor over time, i.e., spatiotemporally optimal plans. Sixteen phantom cases with various sizes and locations of tumors and organs-at-risk (OAR) were generated using in-house software. Each case was planned with DART and conventional IMRT prescribing 60 Gy in 30 fractions. The observations of the change in the tumor volume over a treatment course were simulated using a two-level cell population model. Monte Carlo simulations of the treatment course for each case were run to account for uncertainty in the tumor response. The same OAR dose constraints were applied for both methods. The frequency of replanning was varied between 1, 2, 5 (weekly), and 29 times (daily). The final average tumor dose and OAR doses have been compared to quantify the potential dosimetric benefits of DART. Results: The average tumor max, min, mean, and D95 doses using DART relative to these using conventional IMRT were 124.0%–125.2%, 102.1%–114.7%, 113.7%–123.4%, and 102.0%–115.9% (range dependent on the frequency of replanning). The average relative maximum doses for the cord and esophagus, mean doses for the heart and lungs, and D05 for the unspecified tissue resulting 84%–102.4%, 99.8%–106.9%, 66.9%–85.6%, 58.2%–78.8%, and 85.2%–94.0%, respectively. Conclusions: It is feasible to apply DART to the treatment of NSCLC using CBCT to observe the midtreatment tumor state. Potential increases in the tumor dose and reductions in the OAR dose, particularly for parallel OARs with mean or dose–volume constraints, could be achieved using DART compared to nonadaptive IMRT.

60 APPLIED LIFE SCIENCES↗

Scheduling and Operations of the ECOSTRESS Mission

This paper describes the development and use of an automated scheduling system for the National Aeronautics and Space Administration’s (NASA) ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) mission. Key to the success of the ECOSTRESS mission has been the use of automated scheduling in mission analysis pre-launch, and in successful operations where automated scheduling was deployed to address several operational challenges. ECOSTRESS uses an adaptation of the Compressed Large-scale Activity Scheduling and Planning (CLASP) system to automatically select science observations respecting area and point target priorities as well as visibility, illumination, onboard storage, and radiation constraints to satisfy high-level prioritized science campaigns. The ECOSTRESS scheduler was used pre-launch to predict the effectiveness of alternative formulations of science campaign definitions accounting for the impact of data volume, keepout, and orbit/illumination/visibility constraints to derive the initial operational science campaign definitions and priorities. The scheduler was then used after instrument checkout for operations. ECOSTRESS has faced multiple operational challenges relating to instrument firmware and hardware, and the scheduler has been updated several times to address these challenges. The instrument Mass Storage Units (MSUs) had operational issues, requiring the scheduler to plan for and schedule commands to handle intricacies of data management. After many months of operations, both MSUs on the instrument became non-functioning and the firmware of the instrument was updated to bypass the MSUs. A further update to the ECOSTRESS scheduler enabled the scheduler to operate in this new operations mode. The ECOSTRESS scheduler has also been updated to improve handling of along-track uncertainty inherent in International Space Station operations. The flexibility and ease of updating of the automated scheduler has been a significant contributor to successful operations of the ECOSTRESS mission.

Padams, Jordan↗

SU-E-T-33: A Feasibility-Seeking Algorithm Applied to Planning of Intensity Modulated Proton Therapy: A Proof of Principle Study

Purpose: To investigate the applicability of feasibility-seeking cyclic orthogonal projections to the field of intensity modulated proton therapy (IMPT) inverse planning. Feasibility of constraints only, as opposed to optimization of a merit function, is less demanding algorithmically and holds a promise of parallel computations capability with non-cyclic orthogonal projections algorithms such as string-averaging or block-iterative strategies. Methods: A virtual 2D geometry was designed containing a C-shaped planning target volume (PTV) surrounding an organ at risk (OAR). The geometry was pixelized into 1 mm pixels. Four beams containing a subset of proton pencil beams were simulated in Geant4 to provide the system matrix A whose elements a-ij correspond to the dose delivered to pixel i by a unit intensity pencil beam j. A cyclic orthogonal projections algorithm was applied with the goal of finding a pencil beam intensity distribution that would meet the following dose requirements: D-OAR < 54 Gy and 57 Gy < D-PTV < 64.2 Gy. The cyclic algorithm was based on the concept of orthogonal projections onto half-spaces according to the Agmon-Motzkin-Schoenberg algorithm, also known as ‘ART for inequalities’. Results: The cyclic orthogonal projections algorithm resulted in less than 5% of the PTV pixels and less than 1% of OAR pixels violating their dose constraints, respectively. Because of the abutting OAR-PTV geometry and the realistic modelling of the pencil beam penumbra, complete satisfaction of the dose objectives was not achieved, although this would be a clinically acceptable plan for a meningioma abutting the brainstem, for example. Conclusion: The cyclic orthogonal projections algorithm was demonstrated to be an effective tool for inverse IMPT planning in the 2D test geometry described. We plan to further develop this linear algorithm to be capable of incorporating dose-volume constraints into the feasibility-seeking algorithm.

60 APPLIED LIFE SCIENCES↗

Volumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study

Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in the treatment of LNPN. Five consecutive patients previously treated with IMRT for LNPN were selected. VMAT plans were generated for each case using the same planning target volumes (PTV), dose prescriptions and OAR constraints as IMRT. Comparative parameters used to assess target volume coverage, conformity and homogeneity included V95 of the PTV (volume encompassed by the 95% isodose), conformity index (CI) and homogeneity index (HI). In addition, OAR maximum point doses, V20, V30, non-target tissue (NTT) point max doses, NTT volume above reference dose, monitor units (MU) were compared. IMRT and VMAT plans generated were comparable for CI (P = 0.12) and HI (P = 0.89). VMAT plans achieved better V95 (P = < 0.001) and reduced V20 and V30 by 652 cubic centimetres (cc) (28.5%) and 425.7 cc (29.1%), respectively. VMAT increased MU delivered by 18% without a corresponding increase in NTT dose. Compared with IMRT plans for LNPN, VMAT achieved comparable HI and CI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing intergalactic intergalactic magnetic fields with LOFAR LoTSS DR2 data

We use Faraday rotation measurements from the latest catalog LoTSS DR2 from LOFAR to probe intergalactic magnetic fields. To identify the extragalactic component of the observed rotation measure (RM) we use two different techniques: residual rotation measure (RRM) and close radio pairs. For the RRM approach, we conclude that, despite smaller measurement errors in the LOFAR data, robust and conservative treatment of the systematic uncertainties in the Galactic contribution to RM results in the constraint on a homogeneous volume-filling magnetic field at the level 2.4 nG, slightly weaker than previous constraints from NVSS data, and does not allow to probe the presence of over-magnetized bubbles predicted by the AGN feedback model of the IllustrisTNG. Analyzing close radio pairs we found that in only 0.5% of our mock realizations of observed data, the expected contribution from the over-magnetized bubbles does not exceed LoTSS DR2 data.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical and Dosimetric Predictors of Late Rectal Syndrome After 3D-CRT for Localized Prostate Cancer: Preliminary Results of a Multicenter Prospective Study

Purpose: To assess the predictors of late rectal toxicity in a prospectively investigated group of patients treated at 70-80 Gy for prostate cancer (1.8-2 Gy fractions) with three-dimensional conformal radiotherapy. Methods and Materials: A total of 1,132 patients were entered into the study between 2002 and 2004. Three types of rectal toxicity, evaluated by a self-administered questionnaire, mainly based on the subjective objective management, analytic late effects of normal tissue system, were considered: stool frequency/tenesmus/pain, fecal incontinence, and bleeding. The data from 506 patients with a follow-up of 24 months were analyzed. The correlation between a number of clinical and dosimetric parameters and Grade 2 or greater toxicity was investigated by univariate and multivariate (MVA) logistic analyses. Results: Of the 1,132 patients, 21, 15, and 30 developed stool frequency/tenesmus/pain, fecal incontinence, and bleeding, respectively. Stool frequency/tenesmus/pain correlated with previous abdominal/pelvic surgery (MVA, p = 0.05, odds ratio [OR], 3.3). With regard to incontinence, MVA showed the volume receiving {>=}40 Gy (V{sub 40}) (p = 0.035, OR, 1.037) and surgery (p = 0.02, OR, 4.4) to be the strongest predictors. V{sub 40} to V{sub 70} were highly predictive of bleeding; V{sub 70} showed the strongest impact on MVA (p = 0.03), together with surgery (p = 0.06, OR, 2.5), which was also the main predictor of Grade 3 bleeding (p = 0.02, OR, 4.2). Conclusions: The predictive value of the dose-volume histogram was confirmed for bleeding, consistent with previously suggested constraints (V{sub 50} <55%, V{sub 60} <40%, V{sub 70} <25%, and V{sub 75} <5%). A dose-volume histogram constraint for incontinence can be suggested (V{sub 40} <65-70%). Previous abdominal/pelvic surgery correlated with all toxicity types; thus, a modified constraint for bleeding (V{sub 70} <15%) can be suggested for patients with a history of abdominal/pelvis surgery, although further validation on a larger population with longer follow-up is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Relationships Between Rectal Normal Tissue Complication Probability and the Portion of Seminal Vesicles Included in the Clinical Target Volume in Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: To compare dose-volume consequences of the inclusion of various portions of the seminal vesicles (SVs) in the clinical target volume (CTV) in intensity-modulated radiotherapy (IMRT) for patients with prostate cancer. Methods and Materials: For 10 patients with prostate cancer, three matched IMRT plans were generated, including 1 cm, 2 cm, or the entire SVs (SV1, SV2, or SVtotal, respectively) in the CTV. Prescription dose (79.2 Gy) and IMRT planning were according to the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 protocol. We compared plans for percentage of rectal volume receiving minimum doses of 60-80 Gy and for rectal normal tissue complication probability (NTCP[R]). Results: There was a detectable increase in rectal dose in SV2 and SVtotal compared with SV1. The magnitude of difference between plans was modest in the high-dose range. In 2 patients, there was underdosing of the planning target volume (PTV) because of constraints on rectal dose in the SVtotal plans. All other plans were compliant with RTOG 0126 protocol requirements. Mean NTCP(R) increased from 14% to 17% and 18% for SV1, SV2, and SV total, respectively. The NTCP(R) correlated with the size of PTV-rectum volume overlap (Pearson's r = 0.86; p < 0.0001), but not with SV volume. Conclusions: Doubling (1 to 2 cm) or comprehensively increasing (1 cm to full SVs) SV volume included in the CTV for patients with prostate IMRT is achievable in the majority of cases without exceeding RTOG dose-volume limits or underdosing the PTV and results in only a moderate increase in NTCP(R)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revision of Faraday rotation measure constraints on the primordial magnetic field using the IllustrisTNG simulation

ABSTRACT Previously derived Faraday rotation constraints on the volume-filling intergalactic magnetic field (IGMF) have used analytical models that made a range of simplifying assumptions about magnetic field evolution in the intergalactic medium and did not consider the effect of baryonic feedback on large-scale structures. In this work, we revise existing Faraday rotation constraints on the IGMF using a numerical model of the intergalactic medium from the IllustrisTNG cosmological simulation that includes a sophisticated model of the baryonic feedback. We use the IllustrisTNG model to calculate the rotation measure and compare the resulting mean and median of the absolute value of the rotation measure with data from the NRAO VLA Sky Survey (NVSS). The numerical model of the intergalactic medium includes a full magnetohydrodynamic model of the compressed primordial magnetic field as well as a model of the regions where the magnetic field is not primordial, but is rather produced by the process of baryonic feedback. Separating these two types of regions, we are able to assess the influence of the primordial magnetic field on the Faraday rotation signal. We find that by correcting for regions of compressed primordial field and accounting for the fact that part of the intergalactic medium is occupied by magnetic fields spread by baryonic feedback processes rather than by the primordial field relaxes the Faraday rotation bound by a factor of ≃3. This results in B0 < 1.8 × 10−9 G for large correlation length IGMFs.

79 ASTRONOMY AND ASTROPHYSICS↗