Wall Pressure Fluctuations in a Turbulent Boundary Layer
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The laminar boundary layer and the position of the transition point were investigated on a heated flat plate. It was found that the Reynolds number of transition decreased as the temperature of the plate is increased. It is shown from simple qualitative analytical considerations that the effect of variable viscosity in the boundary layer due to the temperature difference produces a velocity profile with an inflection point if the wall temperature is higher than the free-stream temperature. This profile is confirmed by measurements. The instability of inflection-point profiles is discussed. Studies of the flow in the wake of large, two-dimensional roughness elements are presented. It is shown that a boundary-layer can separate and reattach itself to the wall without having transition take place.
The NASA Langley 8-Foot Transonic Pressure Tunnel is a continuous-flow, variable-pressure wind tunnel with control capability to independently vary Mach number, stagnation pressure, stagnation temperature, and humidity. The top and bottom walls of the test section are axially slotted to permit continuous variation of the test section Mach number from 0.2 to 1.2, the slot-width contour provides a gradient-free test section 50 in. long for Mach numbers equal to or greater than 1.0 and 100 in. long for Mach numbers less than 1.0. The stagnation pressure may be varied from 0.25 to 2.0 atm. The tunnel test section has been recalibrated to determine the relationship between the free-stream Mach number and the test chamber reference Mach number. The hardware was the same as that of an earlier calibration in 1972 but the pressure measurement instrumentation available for the recalibration was about an order of magnitude more precise. The principal result of the recalibration was a slightly different schedule of reentry flap settings for Mach numbers from 0.80 to 1.05 than that determined during the 1972 calibration. Detailed tunnel contraction geometry, test section geometry, and limited test section wall boundary layer data are presented.
In the microgravity environment of the Space Shuttle Columbia (Life and Microgravity Mission STS-78), were grown 1-year-old Douglas fir and loblolly pine plants in a NASA plant growth facility. Several plants were harnessed (at 45 degrees ) to establish if compression wood biosynthesis, involving altered cellulose and lignin deposition and cell wall structure would occur under those conditions of induced mechanical stress. Selected plants were harnessed at day 2 in orbit, with stem sections of specific plants harvested and fixed for subsequent microscopic analyses on days 8, 10 and 15. At the end of the total space mission period (17 days), the remaining healthy harnessed plants and their vertical (upright) controls were harvested and fixed on earth. All harnessed (at 45 degrees ) plant specimens, whether grown at 1 g or in microgravity, formed compression wood. Moreover, not only the cambial cells but also the developing tracheid cells underwent significant morphological changes. This indicated that the developing tracheids from the primary cell wall expansion stage to the fully lignified maturation stage are involved in the perception and transduction of the stimuli stipulating the need for alteration of cell wall architecture. It is thus apparent that, even in a microgravity environment, woody plants can make appropriate corrections to compensate for stress gradients introduced by mechanical bending, thereby enabling compression wood to be formed. The evolutionary implications of these findings are discussed in terms of "variability" in cell wall biosynthesis.
The common ancestor of seed plants and mosses contained homo-oligomeric cellulose synthesis complexes (CSCs) composed of identical subunits encoded by a single CELLULOSE SYNTHASE (CESA) gene. Seed plants use different CESA isoforms for primary and secondary cell wall deposition. Both primary and secondary CESAs form hetero-oligomeric CSCs that assemble and function in planta only when all the required isoforms are present. The moss Physcomitrium (Physcomitrella) patens has seven CESA genes that can be grouped into two functionally and phylogenetically distinct classes. Previously, we showed that PpCESA3 and/or PpCESA8 (class A) together with PpCESA6 and/or PpCESA7 (class B) form obligate hetero-oligomeric complexes required for normal secondary cell wall deposition. Here, we show that gametophore morphogenesis requires a member of class A, PpCESA5, and is sustained in the absence of other PpCESA isoforms. Further, PpCESA5 also differs from the other class A PpCESAs as it is able to self-interact and does not co-immunoprecipitate with other PpCESA isoforms. These results are consistent with the hypothesis that homo-oligomeric CSCs containing only PpCESA5 subunits synthesize cellulose required for gametophore morphogenesis. Analysis of mutant phenotypes also revealed that, like secondary cell wall deposition, normal protonemal tip growth requires class B isoforms (PpCESA4 or PpCESA10), along with a class A partner (PpCESA3, PpCESA5, or PpCESA8). Thus, P. patens contains both homo-oligomeric and hetero-oligomeric CSCs.
Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.
Explore the source record for details and available documents.
The empirical scaling for the H-mode power threshold in tokamaks has been revisited using a database with threshold data from machines with a metallic first wall as part of International Tokamak Physics Activity (ITPA) task TC-26. The database contains discharges from ASDEX Upgrade (AUG) (W), JET (Be/W) and Alcator C-Mod (Mo). This was motivated by reports that in like-for-like discharges the power threshold was reduced by approximately 30% after the change from carbon based to metallic first wall materials on AUG (Ryter et al 2013 Nucl. Fusion 53 113003) and JET (Maggi et al 2014 Nucl. Fusion 54 023007). The database contains L–H transition data for all hydrogen isotopes and mixtures, including T and DT from the recent JET campaigns. Compared to the ITPA 2008 scaling (Martin et al 2008 J. Phys.: Conf. Ser. 123 012033), the metal wall scaling has a smaller magnetic field exponent but a larger density exponent. We present an additional parameter to capture the strong dependence of the L–H power threshold (approx. factor 2) on the magnetic configuration in the divertor on JET. The scaling recovers the approximate inverse isotope mass scaling of the threshold power. Alternative scalings involving the plasma current and poloidal magnetic field are explored. Despite the reduction in threshold observed earlier, the scalings based on the metal wall database do not necessarily extrapolate to a lower threshold for ITER compared to the ITPA 2008 scaling, especially at high density. The divertor configuration effect induces the largest uncertainty in the extrapolation.
This paper systematically presents the results of heat transfer and friction factor data measured in five short rectangular channels with turbulence promoters. The project investigated the combined effects of the channel aspect ratio, rib angle-of-attack, and flow Reynolds number on heat transfer and pressure drop in rectangular channels with two opposite ribbed walls. The channel aspect ratio (width-to-height, W/H, ribs on side W) varied from 1/4 to 1/2, to 1, 2, and 4, while the corresponding rib angles-of-attack alpha were 90 deg, 60 deg, 45 deg, and 30 deg, respectively. The Reynolds number range was 10,000-60,000. The results suggest that the narrow aspect ratio channels (W/H less than 1) give much better heat transfer performance than the wide aspect ratio channels (W/H greater than 1). For the square channel (W/H = 1), the 60 deg/45 deg angled ribs provide the best heat transfer performance. For the narrow aspect ratio channel (W/H = 1/4 or 1/2), the 45 deg/60 deg angled ribs are recommended, while the 30 deg/45 deg angled ribs are better for wide aspect ratio channels (W/H = 4 or 2).
The Brine Availability Test in Salt (BATS) is a collaboration between Los Alamos, Sandia, and Lawrence Berkeley National Laboratories that is being conducted to reduce the uncertainties associated with disposal of spent nuclear fuel (SNF) and high-level radioactive waste (HLW) in a hypothetical bedded salt repository. Bedded salt formations may be an acceptable host rock for disposal of nuclear waste due to salt's high thermal conductivity, extremely low permeability, and self-healing capability. In this paper, we report on the first round of the BATS project, a 'shakedown test' known as Phase 1s, with an emphasis on the supporting numerical modeling. The experiment was conducted at the Waste Isolation Pilot Plant (WIPP) using previously drilled horizontal boreholes. The test included a heater borehole in which temperature, pressure, and moisture was monitored, and two nearby temperature monitoring boreholes. Numerical simulations that reflect the 36-year-long history of activity at the WIPP site are necessary to develop the appropriate initial conditions. Testing with different heater designs reveals that a 750 W radiative heater within a borehole can achieve the 120 deg. C borehole wall temperature goal. (authors)
Results from KSTAR powder injection experiments, in which tens of milligrams of boron nitride (BN) were dropped into low-power H-mode plasmas, show an improvement in wall conditions in subsequent discharges and, in some cases, a reduction or elimination of edge-localized modes (ELMs). Injected powder is distributed by the plasma flow and is deposited on the wall and, over the course of several discharges, was observed to gradually reduce recycling by 33%, and decrease both the ELM amplitude and frequency. This is the first demonstration of the use of BN for ELM mitigation. In all of these experiments, an Impurity Powder Dropper (IPD) was used to introduce precise, controllable amounts of the materials into ELMy H-mode KSTAR discharges. The plasma duration was between 10 s and 15 s, 𝐼𝑝 = 500 kA, 𝐵𝑇 = 1.8 T, 𝑃NBI = 1.6 MW, and 𝑃ECH = 0.6 MW. Plasma densities were between 2 and 3 × 1019 m−3. In all cases, the pre-fill and startup gas-fueling was kept constant, suggesting that the decrease in baseline D𝛼 emission is in fact due to a reduction in recycling. The results presented herein highlight the viability of powder injection for intra-shot and between-shot wall conditioning.
Regenerative cooling of rocket engines considering heat transfer, chamber wall, coolant tube and pressure drop
Constitutive equation variation effect on near wall flow pattern of dilute polymer solutions
Generator can produce sinusoidal pressures at frequencies from 300 to 5000 Hz and peak-to-peak amplitudes up to 5.6 lbs/sq in. Amplitude and phase-angle measurements made at various frequencies are compared with measurements from a piezoelectric transducer mounted flush with the resonant tube wall.
Equilibrium model of laminar arc constrictor plasma generator, correlating heat transfer, wall shear stress, friction factor and development length
Structural response and acoustic transmission characteristics of glass pane and standard wood frame construction wall panels subjected to sonic booms
A review of a comprehensive experimental investigation of the heat transfer and boundary layer in 30 deg to 15 deg and 60 deg to 15 deg conical nozzles is presented. The experiments were conducted with air at a stagnation temperature of 539 K (970 R) and throat Reynolds numbers based on a diameter ranging from 6 x 10 to the 5th power to 5 x 10 to the 6th power. Nozzle wall surface finish was varied from a smooth machine finish to a 826 x 10 to the minus 6th power cm (325 x 10 to the minus 6th in.) rms sandblasted finish. Measured heat transfer and wall temperatures are tabulated.