Infrastructure Ecology for Sustainable and Resilient Urban Infrastructure Design

The population growth coupled with increasing urbanization is predicted to exert a huge demand on the growth and retrofit of urban infrastructure, particularly in water and energy systems. The U.S. population is estimated to grow by 23% (UN, 2009) between 2005 and 2030. The corresponding increases in energy and water demand were predicted as 14% (EIA, 2009) and 20% (Elcock, 2008), respectively. The water-energy nexus needs to be better understood to satisfy the increased demand in a sustainable manner without conflicting with environmental and economic constraints. Overall, 4% of U.S. power generation is used for water distribution (80%) and treatment (20%). 3% of U.S. water consumption (100 billion gallons per day, or 100 BGD) and 40% of U.S. water withdrawal (340 BGD) are for thermoelectric power generation (Goldstein and Smith, 2002). The water demand for energy production is predicted to increase most significantly among the water consumption sectors by 2030. On the other hand, due to the dearth of conventional water sources, energy intensive technologies are increasingly in use to treat seawater and brackish groundwater for water supply. Thus comprehending the interrelation and interdependency between water and energy system is imperative to evaluate sustainable water and energy supply alternatives for cities. In addition to the water-energy nexus, decentralized or distributed concept is also beneficial for designing sustainable water and energy infrastructure as these alternatives require lesser distribution lines and space in a compact urban area. Especially, the distributed energy infrastructure is more suited to interconnect various large and small scale renewable energy producers which can be expected to mitigate greenhouse gas (GHG) emissions. In the case of decentralized water infrastructure, on-site wastewater treatment facility can provide multiple benefits. Firstly, it reduces the potable water demand by reusing the treated water for non-potable uses and secondly, it also reduces the wastewater load to central facility. In addition, lesser dependency on the distribution network contributes to increased reliability and resiliency of the infrastructure. The goal of this research is to develop a framework which seeks an optimal combination of decentralized water and energy alternatives and centralized infrastructures based on physical and socio-economic environments of a region. Centralized and decentralized options related to water, wastewater and stormwater and distributed energy alternatives including photovoltaic (PV) generators, fuel cells and microturbines are investigated. In the context of the water-energy nexus, water recovery from energy alternatives and energy recovery from water alternatives are reflected. Alternatives recapturing nutrients from wastewater are also considered to conserve depleting resources. The alternatives are evaluated in terms of their life-cycle environmental impact and economic performance using a hybrid life cycle assessment (LCA) tool and cost benefit analysis, respectively. Meeting the increasing demand of a test bed, an optimal combination of the alternatives is designed to minimize environmental and economic impacts including CO2 emissions, human health risk, natural resource use, and construction and operation cost. The framework determines the optimal combination depending on urban density, transmission or conveyance distance or network, geology, climate, etc. Therefore, it will be also able to evaluate infrastructure resiliency against physical and socio-economic challenges such as population growth, severe weather, energy and water shortage, economic crisis, and so on.

30 DIRECT ENERGY CONVERSION↗

2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2009 through October 31, 2010. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Discussion of the facility’s environmental impacts During the 2010 permit year, approximately 164 million gallons of wastewater were discharged to the Cold Waste Pond. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

99 GENERAL AND MISCELLANEOUS↗

Measured Impact on Space Conditioning Energy Use in a Residence Due to Operating a Heat Pump Water Heater inside the Conditioned Space

The impact on space conditioning energy use due to operating a heat pump water heater (HPWH) inside the conditioned space is analyzed based on 2010-2011 data from a research house with simulated occupancy and hot water use controls. The 2700 ft2 (345 m2) house is located in Oak Ridge, TN (mixed-humid climate) and is equipped with a 50 gallon (189 l) HPWH that provided approximately 55 gallons/d (208 l/d) of hot water at 120 F (46 C) to the house during the test period. The HPWH has been operated every other week from December 2010 through November 2011 in two modes; a heat pump only mode, and a standard mode that utilizes 15355 Btu/hr (4500 W) resistance heating elements. The energy consumption of the air-source heat pump (ASHP) that provides space conditioning for the house is compared for the two HPWH operating modes with weather effects taken into account. Impacts during the heating and cooling seasons are compared.

heat pump water heater↗

Nanoporous Iridium Nanosheets for Polymer Electrolyte Membrane Electrolysis

The growth of the hydrogen economy is predicated on advancements in electrochemical energy technologies, with water electrolysis as a key component to the technological portfolio. Much of the focus on anode catalyst development for polymer electrolyte membrane water electrolyzers (PEMWE) is centered on activity as controlled by compositional and morphological impacts on reactant/intermediate/product adsorption. However, the effectiveness of this strategy is found to be limited upon integration of these materials into PEMWE membrane electrode assemblies (MEA). Regardless of catalyst activity, the combination of electrode inhomogeneity, ionomer integration, and high density of oxide-oxide interfaces yields significant performance losses associated with poor catalytic electrode conductivity. Here many of these limitations are addressed through the development of a unique catalyst morphology composed of nanoporous Ir nanosheets (npIr(x)-NS) that exhibit high catalytic activity for the anodic oxygen evolution reaction and superior electrode electronic conductivity in comparison to a commercial IrO2 nanoparticle catalyst. The utility of the npIr(x)-NS is demonstrated through incorporation into PEMWE MEAs where their performance exceeds that of commercial catalyst coated membranes at loadings as low as 0.06 mg(Ir) cm(-2) while exhibiting a negligible loss in performance following 50 000 accelerated stress test cycles.

Polymer Electrolyte Membrane Electrolysis↗

ENHANCED UNCERTAINTY ANALYSIS FOR SRS COMPOSITE ANALYSIS

The Composite Analysis (CA) performed for the Savannah River Site (SRS) in 2009 (SRS CA 2009) included a simplified uncertainty analysis. The uncertainty analysis in the CA (Smith et al. 2009b) was limited to considering at most five sources in a separate uncertainty calculation performed for each POA. To perform the uncertainty calculations in a reasonable amount of time, the analysis was limited to using 400 realizations, 2,000 years of simulated transport time, and the time steps used for the uncertainty analysis were increased from what was used in the CA base case analysis. As part of the CA maintenance plan, the Savannah River National Laboratory (SRNL) committed to improving the CA uncertainty/sensitivity analysis. The previous uncertainty analysis was constrained by the standard GoldSim licensing which limits the user to running at most four Monte Carlo uncertainty calculations (also called realizations) simultaneously. Some of the limitations on the number of realizations that could be practically run and the simulation time steps were removed by building a cluster of three HP Proliant windows servers with a total of 36 64-bit processors and by licensing the GoldSim DP-Plus distributed processing software. This allowed running as many as 35 realizations simultaneously (one processor is reserved as a master process that controls running the realizations). These enhancements to SRNL computing capabilities made uncertainty analysis: using 1000 realizations, using the time steps employed in the base case CA calculations, with more sources, and simulating radionuclide transport for 10,000 years feasible. In addition, an importance screening analysis was performed to identify the class of stochastic variables that have the most significant impact on model uncertainty. This analysis ran the uncertainty model separately testing the response to variations in the following five sets of model parameters: (a) K{sub d} values (72 parameters for the 36 CA elements in sand and clay), (b) Dose Parameters (34 parameters), (c) Material Properties (20 parameters), (d) Surface Water Flows (6 parameters), and (e) Vadose and Aquifer Flow (4 parameters). Results provided an assessment of which group of parameters is most significant in the dose uncertainty. It was found that K{sub d} and the vadose/aquifer flow parameters, both of which impact transport timing, had the greatest impact on dose uncertainty. Dose parameters had an intermediate level of impact while material properties and surface water flows had little impact on dose uncertainty. Results of the importance analysis are discussed further in Section 7 of this report. The objectives of this work were to address comments received during the CA review on the uncertainty analysis and to demonstrate an improved methodology for CA uncertainty calculations as part of CA maintenance. This report partially addresses the LFRG Review Team issue of producing an enhanced CA sensitivity and uncertainty analysis. This is described in Table 1-1 which provides specific responses to pertinent CA maintenance items extracted from Section 11 of the SRS CA (2009). As noted above, the original uncertainty analysis looked at each POA separately and only included the effects from at most five sources giving the highest peak doses at each POA. Only 17 of the 152 CA sources were used in the original uncertainty analysis and the simulation time was reduced from 10,000 to 2,000 years. A major constraint on the original uncertainty analysis was the limitation of only being able to use at most four distributed processes. This work expanded the analysis to 10,000 years using 39 of the CA sources, included cumulative dose effects at downstream POAs, with more realizations (1,000) and finer time steps. This was accomplished by using the GoldSim DP-Plus module and the 36 processors available on a new windows cluster. The last part of the work looked at the contribution to overall uncertainty from the main categories of uncertainty variables: K{sub d}s, dose parameters, flow parameters, and material properties. This was not intended to be a detailed sensitivity analysis but only to see in very general terms what broad category of parameters contributes most significantly to overall uncertainty in the CA dose. This analysis was not intended to be a final CA uncertainty calculation and there was no intent to revise the stochastic distributions as part of this work.

54 ENVIRONMENTAL SCIENCES↗

Integrated Simulations of the Sabatier and Carbon Vapor Deposition Reactor to Understand Its Impacts to Operations and Performance

The carbon vapor deposition (CVD) reactor is a technology developed by Honeywell Aerospace to convert methane, at high temperatures, into hydrogen and solid carbon. This element is coupled with a Sabatier reactor to support a closed-loop environmental control and life support system with the aim of achieving nearly complete oxygen recovery (> 95%). Initial open-loop, brassboard CVD reactor tests and simulations have shown the CVD’s ability to achieve moderately high methane conversion and high hydrogen selectivity. However, in an integrated system, additional deficiencies are expected due to recycling of unreacted or extraneous species from the Sabatier reactor (e.g., carbon dioxide, hydrogen, water) and CVD reactor (e.g., hydrocarbons, methane, etc.). Sabatier and CVD reactor models were integrated and simulated to predict potential impacts to individual reactors’ and the overall system’s performance. The simulations showed that increasing the recycle of the CVD effluent hydrogen combined with decreasing the system inlet hydrogen flow rate (i.e., drawing a stoichiometric flow rate from an electrolyzer) can lead to an oxygen recovery of > 95%. However, system integration comes at a detriment to the individual reactors. The simulations show the initial conversion from the integrated system (Sabatier = 87% and CVD = 59%) to be lower than the standalone systems (Sabatier = 91% and CVD = 69%). Furthermore, transient simulations show substrate densification, leading to worsening methane conversion coupled with increasing acetylene production, which is commensurate with soot formation. Simulations predict a shortening of the maintenance interval (i.e., time until CVD methane conversion drops below 50%) in the integrated system, which would increase the consumable substrate mass. These analyses highlight the importance of long-duration, integrated tests to corroborate these findings as well as suggest potential modifications (e.g., intermediate gas separations) to improve performance.

Air Revitalization↗

EBSD Characterization of Tubular Cladding Plasticity after Bend Testing: A Feasibility Study

The Light Water Reactor Sustainability (LWRS) Program developed a bend test method for tubular samples during FY12. The purpose of this report is to provide details of the Electron Backscattered Diffraction (EBSD) measurements performed on the various sample sets to provide a comparative baseline of the impact that the silicon carbide ceramic matrix composites (SiC-CMC) sleeves had on the deformation and plasticity properties of the Zircaloy-4 (Zr-4) cladding tube.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IASCC of 304 SS in BWR environments: Effects of post-irradiation annealing and surface condition

To investigate the impact of low-temperature post-irradiation annealing (PIA) on the stress corrosion cracking of neutron-irradiated 304 stainless steel, constant extension rate tests were conducted in simulated boiling water reactor normal water chemistry (BWR-NWC) and hydrogenated water chemistry (HWC) environments. Ten tensile samples, comprising five as-irradiated and five PIA specimens, were prepared by electropolishing the gauge section of electric discharge machined (EDM) samples. Here, the annealing treatment reduced the yield strength from approximately 550 MPa to around 425 MPa and significantly restored the ductility and the strain hardening capability of the alloy. Consequently, the susceptibility of this material to irradiation-assisted stress corrosion cracking (IASCC) was effectively mitigated, which is more prominent in HWC, as evident from fractography, which indicated a decreased propensity for intergranular (IG) fracture. Furthermore, it was observed that the polished surface facilitated crack initiation more readily than the EDM surface, suggesting that the EDM process suppressed crack initiation to some extent.

Crack initiation↗

Advanced underwater lift device

Flexible underwater lift devices ('lift bags') are used in underwater operations to provide buoyancy to submerged objects. Commercially available designs are heavy, bulky, and awkward to handle, and thus are limited in size and useful lifting capacity. An underwater lift device having less than 20 percent of the bulk and less than 10 percent of the weight of commercially available models was developed. The design features a dual membrane envelope, a nearly homogeneous envelope membrane stress distribution, and a minimum surface-to-volume ratio. A proof-of-concept model of 50 kg capacity was built and tested. Originally designed to provide buoyancy to mock-ups submerged in NASA's weightlessness simulators, the device may have application to water-landed spacecraft which must deploy flotation upon impact, and where launch weight and volume penalties are significant. The device may also be useful for the automated recovery of ocean floor probes or in marine salvage applications.

Flanagan, David T.↗

Marine & hydrokinetic technology development.

The Wind and Water Power Program supports the development of marine and hydrokinetic devices, which capture energy from waves, tides, ocean currents, the natural flow of water in rivers, and marine thermal gradients, without building new dams or diversions. The program works closely with industry and the Department of Energy's national laboratories to advance the development and testing of marine and hydrokinetic devices. In 2008, the program funded projects to develop and test point absorber, oscillating wave column, and tidal turbine technologies. The program also funds component design, such as techniques for manufacturing and installing coldwater pipes critical for ocean thermal energy conversion (OTEC) systems. Rigorous device testing is necessary to validate and optimize prototypes before beginning full-scale demonstration and deployment. The program supports device testing by providing technology developers with information on testing facilities. Technology developers require access to facilities capable of simulating open-water conditions in order to refine and validate device operability. The program has identified more than 20 tank testing operators in the United States with capabilities suited to the marine and hydrokinetic technology industry. This information is available to the public in the program's Hydrodynamic Testing Facilities Database. The program also supports the development of open-water, grid-connected testing facilities, as well as resource assessments that will improve simulations done in dry-dock and closed-water testing facilities. The program has established two university-led National Marine Renewable Energy Centers to be used for device testing. These centers are located on coasts and will have open-water testing berths, allowing researchers to investigate marine and estuary conditions. Optimal array design, development, modeling and testing are needed to maximize efficiency and electricity generation at marine and hydrokinetic power plants while mitigating nearby and distant impacts. Activities may include laboratory and computational modeling of mooring design or research on device spacing. The geographies, resources, technologies, and even nomenclature of the U.S. marine and hydrokinetic technology industry have yet to be fully understood or defined. The program characterizes and assesses marine and hydrokinetic devices, and then organizes the collected information into a comprehensive and searchable Web-based database, the Marine and Hydrokinetic Technology Database. The database, which reflects intergovernmental and international collaboration, provides industry with one of the most comprehensive and up-to-date public resources on marine and hydrokinetic devices.

13 HYDRO ENERGY↗

Principles of water oxidation and O2-based hydrocarbon transformation by multinuclear catalytic sites

Abstract The central thrust of this integrated experimental and computational research program was to obtain an atomistic-level understanding of the structural and dynamic factors underlying the design of catalysts for water oxidation and selective reductant-free O2-based transformations. The focus was on oxidatively robust polyoxometalate (POM) complexes in which a catalytic active site interacts with proximal metal centers in a synergistic manner. Thirty five publications in high-impact journals arose from this grant. I. Developing an oxidatively and hydrolytically stable and fast water oxidation catalyst (WOC), a central need in the production of green fuels using water as a reductant, has proven particularly challenging. During this grant period we have designed and investigated several carbon-free, molecular (homogenous), oxidatively and hydrolytically stable WOCs, including the Rb8K2[{Ru4O4(OH)2(H2O)4}(γ-SiW10O36)2]·25H2O (1) and [Co4(H2O)2(α-PW9O34)2]10- (2). Although complex 1 is fast, oxidatively and hydrolytically stable WOC, Ru is neither abundant nor inexpensive. Therefore, development of a stable and fast carbon-free homogenous WOC, based on earth-abundant elements became our highest priority. In 2010, we reported the first such catalyst, complex 2. This complex is substantially faster than 1 and stable under homogeneous conditions. Recently, we have extended our efforts and reported a V2-analog of the complex 2, i.e. [Co4(H2O)2(α-VW9O34)2]10- (3), which shows an even greater stability and reactivity. We succeeded in: (a) immobilizing catalysts 1 and 2 on the surface of various electrodes, and (b) elucidating the mechanism of O2 formation and release from complex 1, as well as the Mn4O4L6 “cubane” cluster. We have shown that the direct O-O bond formation is the most likely pathway for O2 formation during water oxidation catalyzed by 1. II. Oxo transfer catalysts that contain two proximal and synergistically interacting redox active metal centers in the active site form another part of considerable interest of our grant because species with such sites [including methane monooxygenase (MMO) and more] are some of the most effective oxygenase catalysts known. Our team conducted the following research on γ-M2-Keggin complexes: (a) investigated stability of the trimer [{Fe3(OH)3(H2O)2}3(γ-SiW10O36)3]15-, 4, in water, and developed the chemistry and catalysis of the di-iron centered POM, [γ(1,2)-SiW10{Fe(OH)}2O38]6-, 5, in organic solvents (Figure 2). We also study the thermodynamic and structural stability of γ-M2-Keggin in aqueous media for different M’s (d-electron metals). We have defined two structural classes of POMs with proximally bound d-electron metal centers. We refer to these structural isomers of the {γ-M2SiW10} family of POMs as “in-pocket” and “out-of pocket”. We have elucidated the factors controlling the structure and stability of the V, Fe, Ru, Tc, Mo and Rh derivatives of [(SiO4)M2(OH)2W10O32]4- using a range of computational tools. We have: (a) demonstrated that heteroatom X in these polyanions may function as an “internal switch” for defining the ground electronic states and, consequently, the reactivity of the γ-M2-Keggin POM complexes; (b) elucidated reactivity of divacant lacunary species and polyperoxotungstates (PPTs), {Xn+O4[WO(O2)2]4}n-, which could be degradation products of γ-M2-Keggin complexes in aqueous media; (c) elucidated the role of the POM ligand in stabilization of {Ru2} and {(Ru-oxo)2} fragments in the reactant and product of the reaction of {γ-[(Xn+O4)Ru2(OH)2W10O32]}(8-n)- (where X = Si4+, P5+ and S6+) with O2, and (d) the mechanisms of olefin epoxidation catalyzed by these di-d-transition metal substituted and divacant lacunary γ-M2-Keggin complexes. III. Complementing the efforts presented above was the development of less time-consuming but reasonably accurate computational methods allowing one to explore more deeply large catalytic systems. We developed Reactive Force Field (ReaxFF) to study interaction of the targeted POMs with water, proton and hydroxide ions in the liquid phase. We tested our ReaxFF parameters on the Lindqvist POMs, M6O19n-, where M = Nb and Ta. These parameters are made available as part of the ReaxFF code. In addition, we have developed parameters for Sc, Ti, Fe, Co and Ni in combination with H, C, N, O, as well as the same metal (M-M) for the spin-polarized self-consistent-charge density-functional tight-binding (DFTB) method. Test calculations showed that the DFTB method with the present parameters in most cases reproduces structural properties very well. These parameters are made available as part of the DFTB code. Thus, this DOE BES funded research project has clarified several key areas impacting (a) water oxidation and O2-based hydrocarbon transformation, (b) stabilization of key structures and catalytic intermediates in such processes, (c) immobilization of molecular catalysts on metal oxide surfaces, and (d) application of optimal computational methods to study reaction dynamics in large systems.

58 GEOSCIENCES↗

CO2-Binding Organic Liquids Gas Capture with Polarity-Swing-Assisted Regeneration Full Technology Feasibility Study B1 - Solvent-based Systems

PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600 cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present

Heldebrant, David J↗

Assessing the Long-Term Stability of Anion Exchange Membranes for Electrochemical CO 2 Reduction

Materials and cell components used in CO 2 electrolysis have largely been adapted from technologies initially developed for water electrolysis and fuel cells. However, electrochemical CO 2 reduction introduces distinct material challenges due to the unique chemical environment in this process. Here, in this study, we conducted ex-situ 1000 h stability tests on commonly used anion exchange membranes, exposing them exclusively to electrolytes and organic molecules used or produced during CO 2 electrolysis, at concentrations relevant to and compatible with postseparation processes. Notably, 15% w/w n-propanol and 5 M acetic acid caused complete dissolution or partial disintegration of the membranes unless cross-linking was present and remained stable throughout the test. When the membranes stayed physically intact, most of them exhibited excellent chemical stability in alkaline medium containing alcohols or formic acid, which was confirmed by vibrational spectroscopy and ion exchange capacity measurements. However, exposure to alcohol-and acid-containing solutions led to a substantial increase in swelling and water uptake, with potential implications for mechanical stability, ion/product crossover, and compression management of adjacent components. The potential effects of CO 2 electroreduction products on membrane stability, their subsequent impact on electrolyzer performance, and mitigation strategies are discussed.

CO2RR↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells

We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.

25 ENERGY STORAGE↗

Using Financial Contracts to Facilitate Informal Leases Within a Western United States Water Market Based on Prior Appropriation

The ability to reallocate water to higher-value uses during drought is an increasingly important “soft-path” tool for managing water resources in an uncertain future. In most of the Western United States, state-level water market institutions that enable reallocation also impose substantial transaction costs on market participants related to regulatory approval and litigation. These transaction costs can be prohibitive for many participants in terms of both costs and lengthy approval periods, limiting transfers and reducing allocation efficiency, particularly during drought crises periods. This manuscript describes a mechanism to reduce transaction costs by adapting an existing form of informal leases to facilitate quicker and less expensive transfers among market participants. Instead of navigating the formal approval process to lease a water right, informal leases are financial contracts for conservation that enable more junior holders of existing rights to divert water during drought, thereby allowing the formal transfer approval process to be bypassed. The informal leasing approach is tested in the Upper Colorado River Basin, where drought and institutional barriers to transfers lead to frequent shortages for urban rights holders along Colorado's Front Range. Informal leases are facilitated via option contracts that include adaptive triggers and that define volumes of additional, compensatory, releases designed to mitigate impacts to instream flows and third parties. Results suggest that more rapid reallocation of water via informal leases could have resulted in up to $222 million in additional benefits for urban rights holders during the historical period 1950–2013.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SRNL SHELF LIFE STUDIES - SCC STUDIES AT ROOM TEMPERTURE [stress corrosion cracking ]

Phase II, Series 2 corrosion testing performed by the Savannah River National Laboratory (SRNL) for the Department of Energy 3013 container has been completed. The corrosion tests are part of an integrated plan conducted jointly by Los Alamos National Laboratory and the Savannah River Site. SRNL was responsible for conducting corrosion studies in small-scale vessels to address the influence of salt composition, water loading, and type of oxide/salt contact on the relative humidity inside a 3013 container and on the resulting corrosion of Type 304L and 316L stainless steel (304L and 316L). This testing was conducted in two phases: Phase I evaluated a broad spectrum of salt compositions and initial water loadings on the salt mixtures exposed to 304L and 316L and the resulting corrosion; Phase II evaluated the corrosion of 304L at specific water loadings and a single salt composition. During Phase I testing at high initial moisture levels (0.35 to 1.24 wt%)a, the roomtemperature corrosion of 304L exposed to a series of plutonium oxide/chloride salt mixtures ranged from superficial staining to pitting and stress corrosion cracking (SCC). 304L teardrop coupons that exhibited SCC were directly exposed to a mixture composed of 98 wt % PuO2, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl2. Cracking was not observed in a 316L teardrop coupon. Pitting was also observed in this environment for both 304L and 316L with depths ranging from 20 to 100 μm. Neither pitting nor SCC was observed in mixtures with a greater chloride salt concentration (5 and 28 wt%). These results demonstrated that for a corrosive solution to form a balance existed between the water loading and the salt chloride concentration. This chloride solution results from the interaction of loaded water with the hydrating CaCl2 salt. In Phase II, Series 1 tests, the SCC results were shown to be reproducible with cracking occurring in as little as 85 days. The approximate 0.5 wt% moisture level was found to result in an initial relative humidity of ~55% within the small-scale vessels. Pits were found to be associated with cracks and appeared to act as initiators for the cracking. In a vapor-space only exposure, the weld oxide, which results from the TIG closure weld used to fabricate the teardrop coupon, was also shown to be more susceptible to pitting corrosion than a surface free from weld oxide. This result has important implications for the closure weld of the 3013 inner can since the weld oxide on the can internal surface cannot be removed. The results from the Phase II, Series 2 tests further demonstrated the significance of forming a solution with a critical chloride concentration for corrosion to proceed. 304L teardrop coupons were found to corrode only by pitting with a similar oxide/salt mixture as used in Series 1 testing but with a lower water loading of 0.2 wt%, which resulted in an initial relative humidity of 35-38%. These tests ran twice as long as those for Series 1 testing. The exposure condition was also found to impact the corrosion with salt-exposed surfaces showing lower corrosion resistance. Additional analyses of the Series 2 coupons are recommended especially for determining if cracks emanate from the bottom of pits. Data generated under the 2009 3013 corrosion test plan, as was presented here, increased the understanding of the corrosion process within a sealed 3013 container. Along with the corrosion data from destructive evaluations of 3013 containers, the inner can closure weld region (ICCWR) has been identified as the most vulnerable area of the inner can where corrosion may lead to corrosive species leaking to the interior surface of the outer container, thereby jeopardizing the integrity of the 3013 container. A new corrosion plan has been designed that will characterize the corrosion at the ICCWR of 3013 DEs as well as parameters affecting this corrosion.

3013 plutonium storage, stress corrosion cracking,↗

Sub-kilometer rampart craters in the equatorial region of Mars: Possible implications for the state and distribution of regolith H2O

It was long suspected that Martian rampart crater ejecta morphology originates from an impact into a water or ice-rich crust. If the water-impact hypothesis is correct, then the occurrence of rampart craters at all latitudes, elevations, and in all types of terrain, implies that the distribution of regolith H2O on Mars is global. To test this hypothesis, the occurrence of rampart craters was examined at three locations within the latitude band of + or - 30 degrees (specifically, within the ridged plains unit covered by MC-18). The analysis indicates that while few in number, rampart craters with diameters smaller than 3 km are indeed present at several locations withing the equatorial region of Mars. This finding appears to have significant implications for the inferred state and distribution of subsurface H2O. A more comprehensive analysis of the occurrence of sub-kilometer rampart craters is currently underway.