Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Automated Image Analysis Corrosion Working Group Update: February 1, 2018

These are slides for the automated image analysis corrosion working group update. The overall goals were: automate the detection and quantification of features in images (faster, more accurate), how to do this (obtain data, analyze data), focus on Laser Scanning Confocal Microscope (LCM) data (laser intensity, laser height/depth, optical RGB, optical plus laser RGB).

47 OTHER INSTRUMENTATION↗

Key Nuclear Data Impacting Reactivity in Advanced Reactors

Advanced reactor concepts currently being developed throughout the industry are significantly different from light water reactor (LWR) designs with respect to geometry, materials, and operating conditions, and consequently, with respect to their reactor physics behavior. Given the limited operating experience with non-LWRs, the accurate simulation of reactor physics and the quantification of associated uncertainties are critical for ensuring that advanced reactor concepts operate within the appropriate safety margins. Nuclear data are a major source of input uncertainties in reactor physics analysis. As part of an ongoing project at Oak Ridge National Laboratory (ORNL), the effects of nuclear data uncertainties on key figures of merit associated with advanced reactor safety are being assessed for selected advanced reactor technologies. Key nuclear data relevant for reactor safety analysis for each selected advanced reactor technology were identified, and their impact on important key figures of merit was assessed. Available advanced reactor specifications were reviewed, results from studies performed at ORNL and other research institutions were consulted, and available evaluated nuclear data libraries were analyzed. This report summarizes the key nuclear data for nuclides in the fuel, as well as other significant data, including scattering and neutron capture in various materials for the moderator, coolant, and structure of the considered advanced reactors. For the considered advanced reactors that use low-enriched uranium (LEU) fuel, results from LWR studies provided insight into relevant nuclear data given the lack of available studies specifically addressing these new systems. The major nominal missing data that were identified consist of thermal scattering data and 135m Xe cross section data for molten salt reactor (MSR) analysis. The identified major gaps with respect to nuclear data uncertainties are missing uncertainties of thermal scattering data for high temperature gas-cooled reactors and moderated MSR systems, and incomplete uncertainties on angular distributions in particular for fast spectrum systems, such as sodiumcooled fast reactors, fast molten salt reactors, and heat pipe reactors. Furthermore, it was found that special attention should be paid to cross section and uncertainty differences between different evaluated nuclear data library releases, because significant differences in nuclear data that can lead to major differences in reactivity calculations were found, even for well-known nuclides.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Nuclear Data Assessment for Advanced Reactors

Advanced reactor concepts being developed throughout the industry are significantly different from light-water reactor (LWR) designs with respect to geometry, materials, and operating conditions, and consequently, with respect to their reactor physics behavior. Given the limited operating experience with non-LWRs, the accurate simulation of reactor physics and the quantification of associated uncertainties are important for ensuring that the nuclear design for advanced reactor concepts include appropriate margins. Nuclear data are a major source of input uncertainties in reactor physics analysis. As part of a project sponsored by the US Nuclear Regulatory Commission at Oak Ridge National Laboratory (ORNL), key nuclear data relevant to reactor safety analysis in selected advanced reactor technologies were identified, and their impacts on important key figures of merit were assessed based on (1) a review of available advanced reactor specifications, (2) analysis of previous studies performed at ORNL and other research institutions, and (3) sensitivity and uncertainty analyses performed for six selected benchmarks—three experimental and three computational—to quantify the impacts of the identified key nuclear data on several key metrics. This report summarizes the key nuclear data—nominal data and nuclear data uncertainties— considering the most important nuclear reactions in the fuel and in various materials for the moderator, coolant, and structure of the considered advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Relevant Advanced Reactor Benchmarks for Nuclear Data Assessment

Advanced reactor concepts currently being developed throughout the industry are significantly different from light water reactor (LWR) designs with respect to geometry, materials, and operating conditions, and consequently, with respect to their reactor physics behavior. Given the limited operating experience with non-LWRs, the accurate simulation of reactor physics and the quantification of associated uncertainties are critical for ensuring that advanced reactor concepts operate within the appropriate safety margins. Nuclear data are a major source of input uncertainties in reactor physics analysis. As part of an ongoing project at Oak Ridge National Laboratory, the effects of nuclear data uncertainties on key figures of merit associated with advanced reactor safety are being assessed for selected advanced reactor technologies. Key nuclear data relevant for reactor safety analysis for each selected advanced reactor technology were identified in Phase 1, and their impact on important key figures of merit was assessed in Phase 2. This report describes the outcome of Phase 3. Available benchmarks and fuel irradiation data for use in evaluating the impact of uncertainties and gaps in nuclear data that impact reactivity control for advanced reactor designs through the fuel cycle were identified and assessed. Benchmarks were identified by searching (1) the Organisation for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) International Criticality Safety Benchmark Evaluation Project (IRPhEP) handbook, (2) the OCED/NEA International Reactor Physics Experiment Evaluation Project (IRPhEP) handbook, (3) ongoing OECD/NEA benchmark activities, and (4) documentation in public literature. Relevant benchmarks were identified by selecting reactors with geometry, materials, and neutron energy spectra similar to those of selected advanced reactor technologies. This assessment identified six benchmarks, of which three are experimental and three are purely computational. One experimental and one computation benchmark contain depleted fuel; all others are limited to fresh fuel. This report provides short descriptions of the selected benchmarks along with the availability of measured data for comparison.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid-K-edge/X-ray Fluorescense Densitometry with Laser-Compton Scattered X-rays

The quantitative verification of the accountancy of fissile nuclear materials through independent measurements represents one of the key elements of nuclear materials Safeguards. Elemental probes of materials of interest to non-proliferation are critical to research strategy in order to identify sensitive advanced instrumentation detection technologies. Advanced instrumentation for material detection and accountability are needed for use in fuel cycle facilities for real-time in-process monitoring of separations-partitioning, fuels fabrication as well as for traditional safeguards activities. Radiation-based NDA (non-destructive analysis) techniques can provide some vital information about nuclear materials much more quickly, cheaply and safely than chemical or radio chemical analysis. Hybrid K-edge densitometry (HKED) is currently the most accurate nondestructive inspection technique that provides sensitive quantification of heavy metal contamination. HKED in a technique that exploits both K-edge absorption and X-ray fluorescence (XRF) and allows simultaneously greater elemental specificity and lower detection limits

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Towards a Satellite Formaldehyde – in situ Hybrid Estimate for Organic Aerosol Abundance

Organic aerosol (OA) is one of the main components of the global particulate burden and intimately links natural and anthropogenic emissions with air quality and climate. It is challenging to accurately represent OA in global models. Direct quantification of global OA abundance is not possible with current remote sensing technology; however, it may be possible to exploit correlations of OA with remotely observable quantities to infer OA spatiotemporal distributions. In particular, formaldehyde (HCHO) and OA share common sources via both primary emissions and secondary production from oxidation of volatile organic compounds (VOCs). Here, we examine OA–HCHO correlations using data from summertime airborne campaigns investigating biogenic (NASA SEAC4RS and DC3), biomass burning (NASA SEAC4RS), and anthropogenic conditions (NOAA CalNex and NASA KORUS-AQ). In situ OA correlates well with HCHO (r=0.59–0.97), and the slope and intercept of this relationship depend on the chemical regime. For biogenic and anthropogenic regions, the OA–HCHO slopes are higher in low NOx conditions, because HCHO yields are lower and aerosol yields are likely higher. The OA–HCHO slope of wildfires is over 9 times higher than that for biogenic and anthropogenic sources. The OA–HCHO slope is higher for highly polluted anthropogenic sources (e.g., KORUS-AQ) than less polluted (e.g., CalNex) anthropogenic sources. Near-surface OAs over the continental US are estimated by combining the observed in situ relationships with HCHO column retrievals from NASA's Ozone Monitoring Instrument (OMI). HCHO vertical profiles used in OA estimates are from climatology a priori profiles in the OMI HCHO retrieval or output of specific period from a newer version of GEOS-Chem. Our OA estimates compare well with US EPA IMPROVE data obtained over summer months (e.g., slope =0.60–0.62, r=0.56 for August 2013), with correlation performance comparable to intensively validated GEOS-Chem (e.g., slope =0.57, r=0.56) with IMPROVE OA and superior to the satellite-derived total aerosol extinction (r=0.41) with IMPROVE OA. This indicates that OA estimates are not very sensitive to these HCHO vertical profiles and that a priori profiles from OMI HCHO retrieval have a similar performance to that of the newer model version in estimating OA. Improving the detection limit of satellite HCHO and expanding in situ airborne HCHO and OA coverage in future missions will improve the quality and spatiotemporal coverage of our OA estimates, potentially enabling constraints on global OA distribution.

anthropogenic emissions↗

Total Protein Analysis in Algae via Bulk Amino Acid Detection: Optimization of Amino Acid Derivatization after Hydrolysis with O -Phthalaldehyde 3-Mercaptopropionic Acid (OPA-3MPA)

The analysis of protein in algal biomass is one of the most critical areas of commercial development of algae characterization for nutritional or other high value applications. A new rapid and accurate method is required that can be widely implemented and that is free from interferences from the complex algal biomass matrix. We developed a simple spectrophotometric method for primary amino acid quantification bulk measurement in an acid hydrolyzed algal biomass preparation, as an alternative to the more labor-intensive amino HPLC acid analysis or less specific nitrogen-to-protein conversion. We have validated an O -phthalaldehyde (OPA)-based derivatization method, showing accurate and linear quantification for standard reference amino acids as well as mixtures, mimicking the amino acid complexity found in algal biomass. The presence of interferences that may be derived from the complex biomass biochemical composition was tested during the method validation phase. We document the application of a novel method of OPA derivatization with 3-mercaptopropionic acid (3MPA) to determine the total amino acid content of harvested algal biomass collected from different, controlled cultivation conditions and demonstrated a within 10% accuracy against a reference measurement of amino acid content in at least 4 species and 10 algal biomass samples, across early, mid, and late-stages of cultivation.

09 BIOMASS FUELS↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Quantification of modeling uncertainty in the Rayleigh damping model

Understanding and accurately characterizing energy dissipation mechanisms in civil structures during earthquakes is an important element of seismic assessment and design. The most commonly used model is attributed to Rayleigh. This paper proposes a systematic approach to quantify the uncertainty associated with Rayleigh's damping model. Bayesian calibration with embedded model error is employed to treat the coefficients of the Rayleigh model as random variables using modal damping ratios. Through a numerical example, we illustrate how this approach works and how the calibrated model can address modeling uncertainty associated with the Rayleigh damping model.

42 ENGINEERING↗

Subspace-based Inverse Uncertainty Quantification for Nuclear Data Assessment

Safety analysis and design optimization depend on the accurate prediction of various reactor attributes. Predictions can be enhanced by reducing the uncertainty associated with the attributes of interest. An inverse problem can be defined and solved to assess the sources of uncertainty, and experimental effort can be subsequently directed to further improve the uncertainty associated with these sources. In this work a subspace-based algorithm for inverse sensitivity/uncertainty quantification (IS/UQ) has been developed to enable analysts account for all sources of nuclear data uncertainties in support of target accuracy assessment-type analysis. An approximate analytical solution of the optimization problem is used to guide the search for the dominant uncertainty subspace. By limiting the search to a subspace, the degrees of freedom available for the optimization search are significantly reduced. A quarter PWR fuel assembly is modeled and the accuracy of the multiplication factor and the fission reaction rate are used as reactor attributes whose uncertainties are to be reduced. Numerical experiments are used to demonstrate the computational efficiency of the proposed algorithm. Our ongoing work is focusing on extending the proposed algorithm to account for various forms of feedback, e.g., thermal-hydraulics and depletion effects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved statistical models for limited datasets in uncertainty quantification using stochastic collocation

This paper presents a data-driven framework for performing uncertainty quantification (UQ) by choosing a stochastic model that accurately describes the sources of uncertainty in a system. This model is propagated through an appropriate response surface function that approximates the behavior of this system using stochastic collocation. Given a sample of data describing the uncertainty in the inputs, our goal is to estimate a probability density function (PDF) using the kernel moment matching (KMM) method so that this PDF can be used to accurately reproduce statistics like mean and variance of the response surface function. Instead of constraining the PDF to be optimal for a particular response function, we show that we can use the properties of stochastic collocation to make the estimated PDF optimal for a wide variety of response functions. We contrast this method with other traditional procedures that rely on the Maximum Likelihood approach, like kernel density estimation (KDE) and its adaptive modification (AKDE). We argue that this modified KMM method tries to preserve what is known from the given data and is the better approach when the available data is limited in quantity. We test the performance of these methods for both univariate and multivariate density estimation by sampling random datasets from known PDFs and then measuring the accuracy of the estimated PDFs, using the known PDF as a reference. Comparing the output mean and variance estimated with the empirical moments using the raw data sample as well as the actual moments using the known PDF, we show that the KMM method performs better than KDE and AKDE in predicting these moments with greater accuracy. This improvement in accuracy is also demonstrated for the case of UQ in electrostatic and electrothermomechanical microactuators. We show how our framework results in the accurate computation of statistics in micromechanical systems.

97 MATHEMATICS AND COMPUTING↗

Adaptive approximation of higher order posterior statistics

Filtering is an approach for incorporating observed data into time-evolving systems. Instead of a family of Dirac delta masses that is widely used in Monte Carlo methods, we here use the Wiener chaos expansion for the parametrization of the conditioned probability distribution to solve the nonlinear filtering problem. The Wiener chaos expansion is not the best method for uncertainty propagation without observations. Nevertheless, the projection of the system variables in a fixed polynomial basis spanning the probability space might be a competitive representation in the presence of relatively frequent observations because the Wiener chaos approach not only leads to an accurate and efficient prediction for short time uncertainty quantification, but it also allows to apply several data assimilation methods that can be used to yield a better approximate filtering solution. The aim of the present paper is to investigate this hypothesis. We answer in the affirmative for the (stochastic) Lorenz-63 system based on numerical simulations in which the uncertainty quantification method and the data assimilation method are adaptively selected by whether the dynamics is driven by Brownian motion and the near-Gaussianity of the measure to be updated, respectively.

97 MATHEMATICS AND COMPUTING↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Emissions From Various Biodiesel Sources Compared to a Range of Diesel Fuels in DPF Equipped Diesel Engines

The purpose of this study was to measure the impact of various sources of petroleum-based and bio-based diesel fuels on regulated emissions and fuel economy in diesel particulate filter (DPF) equipped diesel engines. Two model year 2008 diesel engines were tested with nine fuels including a certification ultra-low sulfur diesel (ULSD), local ULSD, high aromatic ULSD, low aromatic ULSD, and twenty percent blends of biodiesel derived from algae, camelina, soy, tallow, and yellow grease. Regulated emissions were measured over the heavy duty diesel transient test cycle. Measurements were also made of DPF-out particle size distribution and total particle count from a 13-mode steady state test using a fast mobility particle sizer. Test engines were a 2008 Cummins ISB and a 2008 International Maxx Force 10, both equipped with actively regenerated DPFs. Fuel consumption was roughly 2% greater over the transient test cycle for the B20 blends versus certification ULSD in both engines, consistent with the slightly lower energy content of biodiesel. Unlike studies conducted on older model engines, these engines equipped with diesel oxidation catalysts and DPFs showed small or no measurable fuel effect on the tailpipe emissions of total hydrocarbons (THC), carbon monoxide (CO) and particulate matter (PM). No differences in particle size distribution or total particle count were seen in a comparison of certification ULSD and B20 soy, with the exception of engine idling conditions where B20 produced a small reduction in the number of nucleation mode particles. In the Cummins engine, B20 prepared from algae, camelina, soy, and tallow resulted in an approximately 2.5% increase in nitrogen oxides (NO{sub x}) compared to the base fuel. The International engine demonstrated a higher degree of variability for NO{sub x} emissions, and fuel effects could not be resolved (p > 0.05). The group of petroleum diesel test fuels produced a range of NO{sub x} emissions very similar to that caused by blending of biodiesel. Test cycles where an active regeneration of the DPF occurred resulted in a nearly threefold increase in NO{sub x} emissions and a 15% increase in fuel consumption. The full quantification of DPF regeneration events further complicates the accurate calculation of fuel impacts on emissions and fuel consumption.

02 PETROLEUM↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗

Uncertainty Quantification in Scientific ML

The intricate interactions between data sampling, model selection and the inherent randomness in complex systems strongly emphasize the need for a rigorous characterization of ML algorithms. In conventional statistics, uncertainty quantification (UQ) provides this characterization by measuring how accurately a model reflects the physical reality and by studying the impact of different error sources on the prediction.

97 MATHEMATICS AND COMPUTING↗