Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

The influence of dietary intake of omega-3 polyunsaturated fatty acids on the association between short-term exposure to ambient nitrogen dioxide and respiratory and cardiovascular outcomes among healthy adults

Background: Short-term exposure to ambient nitrogen dioxide (NO 2 ) is associated with adverse respiratory and cardiovascular outcomes. Supplementation of omega-3 polyunsaturated fatty acids (PUFA) has shown protection against exposure to fine particulate matter. This study aims to investigate whether habitual omega-3 PUFA intake differentially modify the associations between respiratory and cardiovascular responses and short-term exposure to ambient NO 2 . Methods: Sixty-two healthy participants were enrolled into low or high omega-3 groups based on their habitual omega-3 PUFA intake. Each participant was repeatedly assessed for lung function, blood lipids, markers of coagulation and fibrinolysis, vascular function, and heart rate variability (HRV) in up to five sessions, each separated by at least 7 days. This study was carried out in the Research Triangle area of North Carolina, USA between October 2016 and September 2019. Daily ambient NO 2 concentrations were obtained from an area air quality monitoring station on the day of outcome assessment (Lag0), 4 days prior (Lag1-4), as well as 5-day moving average (5dMA). The associations between short-term exposure to NO 2 and the measured indices were evaluated using linear mixed-effects models stratified by omega-3 levels and adjusted by covariates including relative humidity and temperature. Results: The average concentration of ambient NO 2 during the study periods was 5.3±3.8 ppb which was below the National Ambient Air Quality Standards (NAAQS). In the high omega-3 group, an interquartile range (IQR) increase in short-term NO 2 concentrations was significantly associated with increased lung function [e.g. 1.2% (95%CI: 0.2%, 2.2%) in FVC at lag1, 2.6% (95%CI: 0.4%, 4.8%) in FEV1 at 5dMA], decreased blood lipids [e.g. -2.6% (95%CI: -4.4%, -0.9%) in total cholesterol at lag2, -3.1% (95%CI: -6.1%, 0.0%) in HDL at 5dMA, and -3.1% (95%CI: -5.5%, -0.7%) in LDL at lag2], improved vascular function [e.g. 8.9% (95%CI: 0.6%, 17.2%) increase in FMD and 43.1% (95%CI: -79.8%, -6.3%) decrease in endothelin-1 at 5dMA], and changed HRV parameters [e.g. -7.2% (95%CI: -13.6%, -0.8%) in HFn and 13.4% (95%CI: 0.2%, 28.3%) in LF/HF ratio at lag3]. In the low omega-3 group, an IQR increase in ambient NO 2 was associated with elevations in coagulation markers (von Willebrand Factor, D-dimer) and a decrease in HRV (very-low frequency); however, null associations were observed between short-term NO 2 exposure and changes in lung function, blood lipids, and vascular function. Conclusions: The results in this study imply that dietary omega-3 PUFA consumption may offer respiratory and vascular benefits in response to short-term exposure of healthy adults to NO 2 levels below the NAAQS.

54 ENVIRONMENTAL SCIENCES↗

Hydroxylation and Cation Segregation in (La 0.5 Sr 0.5 )FeO 3-$δ$ Electrodes

Simultaneously achieving high activity and stability is the primary challenge when engineering (electro)catalysts. Transition metal perovskite oxides are employed as air electrodes for solid-oxide fuel cells and electrolyzers. However, degradation of oxygen exchange kinetics at the solid–gas interface, often linked to alkaline-earth cation segregation and precipitation, limits widespread commercialization. Here, we systematically investigated the surface degradation mechanism induced by gas-phase impurities in La 0.5 Sr 0.5 )FeO 3-$δ$ (LSF55) thin-film electrodes by varying the concentration of H 2 O, SO 2 , and CO 2 . Degradation of the area-specific resistance in ambient and humidified synthetic air is significantly greater than in dry ambient and dry synthetic air, pointing to the importance of water vapor. Time-resolved, in situ ambient pressure X-ray photoelectron spectroscopy performed in O 2 showed that nonbulk Sr is present on the surface before the exposure to water vapor. Upon introduction of water vapor, neither additional Sr segregation nor precipitation driven by water vapor is a necessary condition for degradation. Rather, hydroxylation of the surface induces irreversible and significant degradation. At the same time, we show that Sr migration driven by water vapor is partially reversible. These fundamental insights can be used for the rational design of electrodes with improved catalytic stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers (Final Technical Report)

This report summarizes the carbon capture research and development conducted by The State University of New York at Buffalo (UB) and GTI Energy (GTI) for award “DE-FE0031969: Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers” sponsored by the U.S. Department of Energy (DOE). The objective of this project is to develop an innovative sorbent structure of trapped small amines in HNC embedded in PEF for DAC. This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An innovative sorbent structure of trapped small amines in hierarchical nanoporous capsules (HNC) embedded in porous electrospun fibers (PEF) was developed for direct air capture (DAC). This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An interfacial polymerization process was developed, which utilized loaded amines inside mesoporous silica and trimesoyl chloride (TMC) dissolved in organic solvents as the precursors, to generate a polyamide (PA) coating layer on mesoporous silica and thus trap amines. Reaction conditions, including TMC concentration, organic solvents, reaction time, etc., for interfacial polymerization were optimized to effectively trap loaded amines, and cyclic heating-cooling operation was conducted to evaluate the coating quality. Larger pore volume mesoporous silica was also synthesized to increase amine loading and thus increase CO 2 capacity. The optimized sorbent material exhibited CO 2 capacity as high as 4.88 mmol/g under humid DAC conditions and negligible loss (<1%) during 10 cyclic heating-cooling operations. The optimized PA-coated sorbent also showed fast adsorption and desorption kinetics, with <20% t1/2 increase compared to uncoated sorbent. PEF fabrication conditions, including organic solvents for dissolving core and shell polymers, voltage, distance from the nozzle to the collection panel, etc. were adjusted to better incorporate HNC. After incorporating the optimized sorbent material into PEF, the structured sorbent had a CO 2 capacity of approximately 4.0 mmol/g under humid DAC conditions, with capacity loss of 0.17% per cycle and t1/2 increase less than 10%. A techno-economic analysis (TEA) for the process design for a DAC system based on our developed sorbent structure of trapped small amines in HNC embedded in PEF was conducted. The process design included process description and major equipment sizing and energy and mass balances in addition to scale-up research results and estimated capture cost. Aspen Adsorption Simulator was used to fit the experimentally measured breakthrough curves and extract equilibrium and kinetic data of the optimized sorbent. Our results indicated that for a DAC plant with CO 2 productivity of 3,000 tonne/year, the levelized cost of CO 2 capture was $\$$612/tonne, with the largest contribution of 44.33% from the fixed operation cost. Increasing CO 2 productivity, while maintaining similar fixed operation cost, is expected to significantly reduce the CO 2 capture cost. A sensitivity study was also conducted to understand the influence of total plant cost, sorbent cost, CO 2 concentration in the feed, sorbent mat lifetime, sorbent regeneration electricity, and adsorption blower pressure drop on the levelized cost of CO 2 capture, revealing a capture cost range of $\$$520-870/tonne.

36 MATERIALS SCIENCE↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - SPAMS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Source Contributions to Fine Particulate Matter and Attributable Mortality in India and the Surrounding Region

Fine particulate matter (PM 2.5 ) is a leading mortality risk factor in India and the surrounding region of South Asia. This study evaluates the contribution of emission sectors and fuels to PM 2.5 mass for 29 states in India and 6 surrounding countries (Pakistan, Bangladesh, Nepal, Bhutan, Sri Lanka, and Myanmar) by combining source-specific emission estimates, stretched grid simulations from a chemical transport model, high resolution hybrid PM 2.5 , and disease-specific mortality estimates. We find that 1.02 (95% Confidence Interval (CI): 0.78-1.26) million deaths in South Asia attributable to ambient PM 2.5 in 2019 were primarily from three leading sectors: residential combustion (28%), industry (15%), and power generation (12%). Solid biofuel is the leading combustible fuel contributing to the PM 2.5 -attributable mortality (31%), followed by coal (17%), and oil and gas (14%). State-level analyses reveal higher residential combustion contributions (35%-39%) in states (Delhi, Uttar-Pradesh, Haryana) with high ambient PM 2.5 (>95 µg/m 3 ). The combined mortality burden associated with residential combustion (ambient) and household air pollution (HAP) in India is 0.72 million (95% CI:0.54-0.89) (68% attributable to HAP, 32% attributable to residential combustion). Our results illustrate the potential to reduce PM 2.5 mass and improve population health by reducing emissions from traditional energy sources across multiple sources in South Asia.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Implications of Aerosol Physicochemical Properties Including Ice Nucleation at ARM Mega Sites for Improved Understanding of Microphysical Atmospheric Cloud Processes (Final Technical Report)

Continuous, long-term measurements of atmospheric ice-nucleating particles (INPs) that influence clouds and precipitation were conducted to investigate the abundance and variability of ground-level INPs across the world. Three field campaigns were organized by the DOE Atmospheric Radiation Measurement (ARM) program, including Examining INP from Southern Great Plains (ExINP-SGP, 2019), Examining INP from Eastern North Atlantic (ExINP-ENA, 2020 – 2021), and Examining INP from North Slope of Alaska (ExINP-NSA, 2021 – 2024). Additional small-scale supporting field experiments were performed in 2019 and 2021 to collect airborne particulate matter at SGP for complementary laboratory characterization of the particles’ physical and chemical properties [Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY), 2019; ExINP-SGP II, 2021]. In these studies, the PI’s team measured INP concentration with both real-time and laboratory measurements in a wide range of freezing temperatures ($T$ from 0 °C to about –30 °C). This project elucidated spatial variability and seasonality in the abundance of immersion mode active INPs across three ARM sites using a single instrument, a Portable Ice Nucleation Experiment (PINE) chamber version 03 (PINE-03 hereafter). Collocated aerosol and meteorological data were analyzed to assess the correlation between ambient INP abundance, air mass origin region, and meteorological variability. Our findings suggest very high freezing efficiency of INPs at the NSA site across the measured temperatures (ice nucleation active surface site density, $n_s(T)$, $\approx 2 \times 10^{8} - 10^{10}$ m -2 for from –16 to –31 °C), which is a factor of 10 – 1000 times greater efficiency as compared to that found in the previous mid-latitude INP measurements in autumn using the same instrument; surprisingly high INP abundance ($\ge 1 \text{ L}^{-1}$ at –25 °C) for the examined temperatures throughout the year that PINE-03 did not measure at other sites; and high INP concentration in spring, possibly related to arctic haze episodes.

58 GEOSCIENCES↗

Experimental Characterization of an Additively Manufactured Inconel 718 Heat Exchanger for High-Temperature Applications

This work presents the experimental results of a novel, air-to-air, additively manufactured manifold-microchannel heat exchanger with straight fins on both sides. The heat exchanger was made of Inconel 718 using a direct metal laser sintering technique. The overall core size of the heat exchanger was 94 mm × 87.6 mm × 94.4 mm, with a fin thickness of 0.220 mm on both the hot and cold sides. The heat exchanger was tested with pressurized nitrogen gas at 300 °C and 340 kPa for the hot side, while air at an ambient condition was used for the cold side. An overall heat transfer of 276 W/m2K was obtained for Reynolds number values of 132 and 79 for the cold and hot sides, respectively. A gravimetric heat transfer density (Q/m∆T) of 4.7–6.7 W/kgK and a volumetric heat transfer density (Q/V∆T) of 6.9–9.8 kW/m3K were recorded for this heat exchanger with a coefficient of performance value that varied from 42 to 52 over the operating conditions studied here. The experimental pressure drop results were within 10% of the numerical values, while the corresponding heat transfer results were within 17% of the numerical results, mainly due to imperfections in the fabrication process. Despite this penalty, the performance of the tested heat exchanger was superior to the conventional plate-fin heat exchangers: more than 60% of improvements in both gravimetric and volumetric heat transfer densities were recorded for the entire range of experimental data.

42 ENGINEERING↗

Multi-seasonal measurements of the ground-level atmospheric ice-nucleating particle abundance on the North Slope of Alaska

Atmospheric ice-nucleating particles (INPs) are an important subset of aerosol particles that are responsible for the heterogeneous formation of ice crystals. INPs modulate the arctic cloud phase (liquid vs. ice), resulting in implications for radiative feedbacks. The number of arctic INP studies investigating specific INP episodes or sources increased recently. However, existing studies are based on short-duration field data, and long-term datasets are lacking. Continuous, long-term measurements are key to determining the abundance and variability of ambient arctic INPs and constraining aerosol–cloud interactions, e.g., to verify and/or improve simulations of mixed-phase clouds. Here, we present a new long-duration INP dataset from the Arctic: 2 years of predominantly immersion-mode INP concentrations (n INP ) measured continuously at the National Oceanic and Atmospheric Administration's Barrow Atmospheric Baseline Observatory (BRW) on the North Slope of Alaska. A portable ice nucleation experiment chamber (PINE-03), which simulates adiabatic expansion cooling, was used to directly measure the ground-level INP abundance with an approximately 12 min time resolution from October 2021 to December 2023. We document PINE-03 n INP measurements as well as estimated ice nucleation active surface site density (n s ) over a wide range of heterogeneous freezing temperatures from −16 to −31 °C from which we introduce new season-specific parameterizations suitable for modeling mixed-phase clouds. Collocated aerosol and meteorological data were analyzed to assess the correlation between ambient n INP , air mass origin region, and meteorological variability. Our findings suggest (1) very high freezing efficiency of INPs across the measured temperatures (n s ≈ 2×10 8 –10 10 m −2 for −16 to −31 °C), which is a factor of 10–1000 times greater efficiency as compared to that found in the previous mid-latitude INP measurements in fall using the same instrument; (2) surprisingly high n INP (≥ 1 L −1 at −25 °C) for the examined temperatures throughout the year that were not measured by PINE-03 at other sites; and (3) high n INP in spring, possibly related to arctic haze episodes. Relatively low concentrations of aerosol surface area and contrasting high-INP concentrations at BRW relative to mid-latitude sites are the possible reasons for the observed high freezing efficiency.

54 ENVIRONMENTAL SCIENCES↗

Enhanced cooling tower technology for power plant efficiency increase and operating flexibility

The Final Report describes the results of the work completed during the “Enhanced Cooling Tower Technology for Power Plant Efficiency Increase and Operating Flexibility” project. The objectives of work were to develop and demonstrate the prototype (up to 100 kWth) of an economically viable “all weather” Sub-Dew Point Cooling Tower (SDPCT) with inlet air cooling and dehumidification including testing in laboratory-controlled environment for simulating various ambient conditions. The inlet air is cooled and dehumidified by a Pressure Dehumidifying System (PDHS) installed at the cooling tower inlet.

20 FOSSIL-FUELED POWER PLANTS↗

Aging studies of Dual functional materials for CO 2 direct air capture with in situ methanation under simulated ambient conditions: Ru thrifting for cost reduction

Dual function materials (DFMs) comprised of 0.25 %Ru, 6.1 %Na 2 O/γ-Al 2 O 3 //monolith were evaluated for about 250 hours time-on-stream (TOS) at various simulated ambient climate capture conditions followed by temperature swing methanation to 280 °C. Herein this paper focuses on the impact of thrifting Ru to low levels and the impact on performance. Results showed both stable CO 2 capture capacity and CH 4 production with 0.25 % Ru DFM deposited on a ceramic monolith. The CO 2 conversion to CH 4 production was decreased slightly by the Ru decrease from 1 % to 0.25 %. The capture capacity decreased since a lower Ru content reduces the complete decomposition of the Na 2 CO 3 precursor producing fewer active adsorption sites (“Na 2 O”). The deployment of a low Ru DFM monolith would significantly decrease the overall capital cost and give more potential for a large-scale direct air capture and methanation (DACM) application.

03 NATURAL GAS↗

Incorporating Diurnal and Meter-Scale Variations of Ambient CO 2 Concentrations in Development of Direct Air Capture Technologies

To be implemented on climate-relevant scales, direct air capture of CO 2 (DAC) will require large capital-intensive facilities and careful attention to cost minimization. In making decisions among potential sites for DAC facilities, all of the factors that will impact process cost and efficiency should be considered. In this paper we focus on a factor that has previously received little attention in the DAC community, namely variations in atmospheric conditions on hourly time scales and length scales of meters. We present data curated from extensive previous studies of biosphere-atmosphere fluxes with observations of CO 2 concentration, temperature, and relative humidity (RH) with hourly resolution from many sites in North America. These include locations where typical diurnal variations in CO 2 concentration during summer months exceeds 150 ppm. These variations are larger than the seasonal variations that exist between averaged CO 2 concentrations in winter and summer, and they are highly correlated with diurnal variations in temperature and RH. Diurnal variations are dependent on the height above ground at which CO 2 concentrations are measured, with smaller variations existing at heights of 10 m or more than at ground level. We illustrate the potential implications of these short-term variations for the operation and optimization of a DAC process with process-level calculations for a specific adsorption-based process using amine-rich adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vegetation Warming Experiment: Environmental conditions, Utqiagvik (Barrow), Alaska, 2021

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 19 June - 17 September, 2021. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017-2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: Environmental conditions, Utqiagvik (Barrow), Alaska, 2019

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 19 June – 25 September, 2019. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017–2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗