Investigation on the use of a Freely Rotating Rotor at the Cowl Face of a Supersonic Conical Inlet to Reduce Inlet Flow Distortion
An investigation has been made on the use of a freely rotating rotor at the cowl face of a supersonic conical diffuser to determine its effectiveness in reducing inlet flow distortion and the penalty in terms of total-pressure loss imposed by such a device when distortions are negligible. Tests were made with a rotor having an inlet tip diameter of 2.18 inches and a ratio of hub radius to tip radius of 0.52, in conjunction with a conical inlet having a 25 deg semi-vertex cone angle, at a Mach number of 2.1 over an angle-of-attack range of 0 deg to 8 deg. A simplified analysis showing that a supersonic, freely rotating rotor with maximum solidity for noninterference between blades will operate in an undistorted flow with a total-pressure defect of 1 percent or less was experimentally verified. Overall total-pressure distortions of 0.1 to 0.4 and Mach number distortions of 0.4 to 1.4, obtained at 4 deg to 8 deg angle of attack, were reduced about 30 percent and 23 percent, respectively, because of the presence of the rotor, with no measurable total-pressure loss. The rotor increased the peak total-pressure recovery at the simulated combustion chamber 1 1/2 and 3 1/2 percent at 6 deg and 8 deg angles of attack, respectively. This increase is attributed to lower diffusion duct losses as a consequence of a more uniform flow created by the rotor.