At least 343 records · Page 19

Experiment definition phase shuttle laboratory: LDRL-10.6 experiment

Progress is reported in the development of the space shuttle laboratory laser data relay link. The system transmittance of various surfaces was considered in order to examine the coating tradeoffs for the beryllium mirrors. The results of six coating combinations considered are summarized. It is recommended that silver coatings be used throughout the system. Design of the pre-expander and a preliminary alignment procedure implemented to align all optical elements to the reference mechanical axis (the rotational axis of the outer gimbal bearing located between the two Gregorian telescopes) are included. The local oscillator subsystem, consisting of the laser, Stark cell, Stark cell electronics, power supply, starting circuit, and conditioning optics were completed and installed in the optimechanical subsystem and operation against a 10.6 micrometer source was attempted. Preliminary measurements of the HgCdTe mixer showed that this critical element was inoperative and in subsequent tests the receiver front end electronics had also failed. Possible reasons for these failures and corrective action and steps to prevent future recurrence are discussed.

Source record↗

Photoelectron emission analysis of surface elements of the International Sun Earth Explorer

The photoemission was measured of engineering materials (aluminum; copper, plain; copper, abraded; copper-beryllium; magnesium; silver; In2O3 on silica; reflective coating on silica; teflon; kapton; and Pyre ML) associated with the International Sun Earth Explorer (ISEE) Satellite. The procedures used are described, including the experimental equipment; results of the program, the conclusions reached, and areas for further work are presented. Data regarding the measured yield of the 11 materials whose surface emission was determined is included in the form of plots of photoelectric yield versus incident light wavelength.

Spencer, W. T.↗

A two-parameter scintillation spectrometer system for measurement of secondary proton, deuteron, and triton distributions from materials under 558-MeV-proton irradiation

A two-parameter scintillation spectrometer system developed and used to obtain proton, deuteron, and triton double differential cross sections from materials under 558-MeV-proton irradiation is described. The system measures both the time of flight of secondary particles over a 488-cm flight path and the energy deposited in a scintillator, 12.7 cm in diameter and 30.48 cm long. The time resolution of the system is 0.39 nsec. The calculated energy resolution based on this time resolution varies with energy from 1.6 precent to 7.75 percent for 50- and 558-MeV protons. Various systematic and statistical errors are evaluated, and the double differential cross sections for secondary proton and deutron production at 20 deg from a 2.35 g/sq cm thick beryllium target are shown as an example of the results obtainable with this system. The uncertainly in the cross sections for secondary protons varies with particle energy from approximately + or - 9 percent at 50 MeV to approximately + or - 11 percent at 558 MeV.

Beck, S. M.↗

Infrared radiometer for the Pioneer 10 and 11 missions to Jupiter

Pioneer 10 has successfully encountered Jupiter and several of its satellites. The two-channel infrared radiometer used to obtain data relating to thermal properties of the planet and its atmosphere is described. The instrument features a body-fixed, 7.62-cm-diam aperture Cassegrainian telescope with restrahlen filters defining the 14- to 25-micron and 30- to 56-micron bands. Detectors are 88-junction evaporated thin-film thermopiles. Stringent weight constraints of 2 kg dictated all-beryllium construction. Power consumption was 1.2 W.

Bender, M. L.↗

High efficiency conical scanner for earth resources applications

A description is given of a six-arm conical scanner which was selected to provide a continuous line-of-sight scan. Two versions of the instrument are considered. The two versions differ in their weight. The weight of the heavy version is 600 lbs. A light weight design which employs beryllium and aluminum optical components weighs only 350 lbs. A multiplexer and analog-to-digital converter are to be incorporated into the design. Questions of instrument performance are also discussed.

Bates, J. C.↗

Advanced composite structures

A monograph is presented which establishes structural design criteria and recommends practices to ensure the design of sound composite structures, including composite-reinforced metal structures. (It does not discuss design criteria for fiber-glass composites and such advanced composite materials as beryllium wire or sapphire whiskers in a matrix material.) Although the criteria were developed for aircraft applications, they are general enough to be applicable to space vehicles and missiles as well. The monograph covers four broad areas: (1) materials, (2) design, (3) fracture control, and (4) design verification. The materials portion deals with such subjects as material system design, material design levels, and material characterization. The design portion includes panel, shell, and joint design, applied loads, internal loads, design factors, reliability, and maintainability. Fracture control includes such items as stress concentrations, service-life philosophy, and the management plan for control of fracture-related aspects of structural design using composite materials. Design verification discusses ways to prove flightworthiness.

Source record↗

Investigation of SL 1115 X-ray telescope

A polished Kanigen coated beryllium mirror to be used in a glancing incidence X-ray telescope was evaluated. X-ray photographs of the image of a standard high resolution test target were recorded at 8.34 A and the focal plane of the telescope was determined. Reflection efficiency data was obtained using proportional counters and sources at wavelengths of 8.34, 13.3, and 44 A. These data were compared with similar data taken with another metal mirror. The results of the comparison are that the mirror tested in this program shows better resolution and less scattering than the other mirror previously tested. This mirror was chosen as the flight mirror for the SL 1115 X-Ray Telescope to fly on a Skylark sounding rocket. Also, a position sensitive detector placed in the focal plane of the SL 1115 X-Ray Telescope (flight payload) was successfully calibrated using a 10 arc second point source and at wavelengths of 8.34, 13.3, 27, and 44 A.

Froechtenigt, J. F.↗

Laser space rendezvous and docking system trade-off study

The use, design, and fabrication feasibility of scanning the laser beam by swiveling the outside mirror with a ball joint swivel system is examined along with the applicability of graphite reinforced epoxy material for the construction of reflective optics. It is indicated that (1) the cost of graphite-epoxy will be more than that of many other materials due to the amount of special tooling required; (2) the weight advantage of graphite-epoxy over beryllium is minimal; the ball joint swivel system is accurate enough to perform the scanning function; and that the ball joint will result in a simpler and more cost effective scanning mechanism.

Adelman, S.↗

YF-12 Lockalloy ventral fin program, volume 1

Results are presented of the YF-12 Lockalloy Ventral Fin Program which was carried out by Lockheed Aircraft Corporation - Advanced Development Projects for the joint NASA/USAF YF-12 Project. The primary purpose of the program was to redesign and fabricate the ventral fin of the YF-12 research airplane (to reduce flutter) using Lockalloy, and alloy of beryllium and aluminum, as a major structural material. A secondary purpose, was to make a material characterization study (thermodynamic properties, corrosion; fatigue tests, mechanical properties) of Lockalloy to validate the design of the ventral fin and expand the existing data base on this material. All significant information pertinent to the design and fabrication of the ventral fin is covered. Emphasis throughout is given to Lockalloy fabrication and machining techniques and attendant personnel safety precautions. Costs are also examined. Photographs of tested alloy specimens are shown along with the test equipment used.

Duba, R. J.↗

The X-ray polarization experiment on the OSO-8

The OSO-8 satellite, launched on June 21, 1975 contains two X-ray polarimeters. These polarimeters use mosaic crystals of graphite to yield polarization-sensitive Bragg reflection of stellar X-rays. The crystals reflect a narrow energy bandwidth centered at 2.6 and 5.2 keV. The polarimeter background signal is minimized by mounting the crystals on parabolic surfaces which focus the diffracted X-rays onto small-area, beryllium-window proportional counters. This technique permits the observation of low-intensity X-ray sources and reduces the possibility of systematic background effects which could lead to a false signature of polarization. A description of the instrument is given, and the sensitivity to polarization, particularly in regard to binary sources, is discussed. Preliminary results for Cen X-3 and GX5-1 are presented.

Weisskopf, M. C.↗

Experiment definition phase shuttle laboratory. LDRL-10.6 experiment

The work completed on the experiment definition phase of the shuttle laboratory LDRL 10.6 micrometers experiment from 27 September 1975 to 26 January 1976 was reported. This work included progress in the following areas: (1) optomechanical system: completion of detail drawings, completion of the beryllium subassembly, fabrication, checking, and weighing of approximately 95% of the detailed parts, dry film lubrication of the bearings and gears, and initiation of assembly of the gimbals; (2) optics: update of the detailed optical layout, receipt of nine mirrors and the pre-expander; (3) miscellaneous: delivery of draft material for the final report, completion of optical testing of the 10.6 micrometers receiver, and receipt, assembly, and checkout of NASA test console.

Source record↗

Design principles of a rotating medium speed mechanism

Design principles of a medium speed mechanism (MSM) are presented, including discussion on the relative merits of beryllium and aluminium as structural materials. Rotating at a speed of 60 rpm, the application envisaged for the MSM was as a despin bearing for the despun platform or despun antenna of a spin stabilized satellite. The MSM was built and tested to qualification level and is currently undergoing real time life testing.

Hostenkamp, R. G.↗

A cooled infrared telescope for the Space Shuttle - The Spacelab Infrared Telescope Facility /SIRTF/

NASA has completed a preliminary design study of a 1.2 m, cooled infrared telescope for use on 7 to 28 day Spacelab missions. Beryllium optics, cooled to below 20 K with supercritical helium, are used. Noise in the infrared telescope will be less by a factor of 1,000 than that of ground-based telescopes operating at 10 microns (when the telescopes are operated over comparable bandwidths and fields of view). The Spacelab infrared telescope facility will enable astronomers to see more than 30 times deeper into the universe than is now possible over most of its 5-200 microns optimum spectral range. Such capability will initiate a spectacular advance in our knowledge and understanding of the cool regions of the universe where molecules and dust are the predominant radiators and absorbers.

Witteborn, F. C.↗

A balloon measurement of the cosmic ray element abundances

The experiment described was flown from Thompson, Canada in August, 1973 to measure the cosmic ray element abundances in the atmosphere. All particles used in the analysis, including approximately 25,000 oxygen and 1600 iron nuclei, had sufficient energy at the top of the atmosphere to trigger the Cerenkov counter. Nuclei between beryllium and nickel were identified, using two plastic scintillators and an acrylic plastic Cerenkov counter. The relative composition and fluxes are determined. Agreement with earlier measurements in the atmosphere is within 5%; however, larger differences appear in composition extrapolated to the top of the atmosphere. In particular, the nitrogen abundance is almost 20% higher and the iron abundance is 20% lower than the generally accepted values.

Ormes, J. F.↗

Cooled infrared telescope development

The feasibility of the design concept for a 1-m-aperture, cryogenically cooled telescope for Spacelab is assessed. The device makes use of double-folded Gregorian reflective optics. The planned cryogen is helium, and beryllium will be used for the 1.2 m primary mirror. Results of studies based on smaller instruments indicate that no new technology will be required to construct a Shuttle Infrared Telescope Facility which will offer improvement over the sensitivity of conventional telescopes by a factor of 1000 at 10 micrometers.

Young, L. S.↗

A preliminary area survey of neutron radiation levels associated with the NASA variable energy cyclotron horizontal neutron delivery system

The 25 MeV deuteron beam from the NASA variable energy cyclotron incident on a thick beryllium target will deliver a tissue neutron dose rate of 2.14 rad micron A-min at a source to skin distance of 125 cm. A neutron survey of the existing hallways with various shielding configurations made during operating of the horizontal neutron delivery system indicates that minimal amounts of additional neutron shielding material are required to provide a low level radiation environment within a self-contained neutron therapy control station. Measurements also indicate that the primary neutron distribution delivered by a planned vertical delivery system will be minimally perturbed by neutrons backscattered from the floor.

Roberts, W. K.↗

Opto-mechanical subsystem with temperature compensation through isothemal design

An opto-mechanical subsystem for supporting a laser structure which minimizes changes in the alignment of the laser optics in response to temperature variations is described. Both optical and mechanical structural components of the system are formed of the same material, preferably beryllium, which is selected for high mechanical strength and good thermal conducting qualities. All mechanical and optical components are mounted and assembled to provide thorough thermal coupling throughout the subsystem to prevent the development of temperature gradients.

Goodwin, F. E.↗