Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An Intelligent Adaptable Monitoring Package. Final Report

The “Intelligent Adaptable Monitoring Package” project was a four-year effort that demonstrated the feasibility of integrated sensing packages at tidal and wave energy sites. Such integration is generally required by the breadth of sensors required to understand environmental effects at marine energy sites and the operational difficulty of deploying, maintaining, and recovering such sensors. Over the course of the project, the Adaptable Monitoring Package (AMP) was deployed in multiple settings, each corresponding to a project budget period: - Budget Period 1: Demonstration of cabled deployment at Pacific Northwest National Laboratory’s Marine Science Laboratory. The deployment highlighted AMP hardware endurance over a 4-month deployment in a tidally-dominated environment and laid the groundwork for machine learning algorithms to detect and classify targets present in active sonar data. - Budget Period 2: Demonstration of an autonomous deployment at PacWave South off the coast of Newport, Oregon. The deployment highlighted the stability of AMP hardware and software, with the autonomous package collecting data on a duty cycle over a 1.5-month deployment. - Budget Period 3: Demonstration of an autonomous deployment powered by a wave energy converter at the U.S. Navy’s Wave Energy Test Site. The deployment highlighted the potential of wave energy to power ocean observatories and led to the development of machine learning algorithms to detect and classify targets in optical camera data. In aggregate, this project’s greatest success was demonstrating the AMP’s flexibility in a range of deployment scenarios. Each budget period represented a “first of a kind” demonstration of integrated instrumentation – cabled AMP, autonomous AMP, wave-energy powered AMP – and each deployment helped to identify and set goals for the next. Further, despite the exploratory nature of these deployments, each one achieved high system up-time and proved that flexible integration of multiple sensors in a single package represents a viable strategy for marine energy environmental monitoring. The key lessons learned from the project are: - Without continuous power, either from a shore cable or in situ source, many of the benefits of integration are lost (If continuous power is not available, the ability to detect rare events is lost, as is the ability to minimize the risk of behavioral changes through adaptive sensing. However, even on a duty cycle, there is still value in being able to acquire synchronous data from multiple sensors.); and - Observations from a moving platform present substantially greater data processing challenges than those from stationary platforms. Finally, these deployments also demonstrate an important truth: successful integration alone does not guarantee that relevant data are collected. To grow the knowledge base about environmental interactions with marine energy converters, integrated systems, like the AMP, need to include the right sensor mix and connect the data pipelines to effective processing algorithms. These deployments establish a strong foundation for future collaborations with the environmental research community: not only to understand the environmental effects of marine energy, but also to improve our general ability to study life in the sea.

16 TIDAL AND WAVE POWER↗

Risk Importance Ranking of Fire Data Parameters to Enhance Fire PRA Model Realism

Fire is historically and analytically a significant contributor to nuclear power plant risk. The level of fire risk and the methods, tools and data for modeling this risk is highly debated by experts. One area of debate is the input data used in fire modeling and how to deal with this data’s high uncertainty. This report outlines initial work performed for determining the key parameters causing this uncertainty and how it propagates into nuclear power plant models. This research paves the way for the development of methods to reduce fire data uncertainty used in modeling. The Nuclear Regulatory Commission has mandated that nuclear power plants perform fire risk modeling. However, there are several issues with the current risk modeling implementation that affect the results. Approved modeling methods can be overly conservative and often do not match plant experience. Also, the data used in the modeling can have high uncertainties and is influenced by expert judgement. To evaluate input data uncertainty, researchers performed an initial review of several fire experiments done at Sandia National Laboratories. Uncertainties for fire data can come from many sources, such as experiment design constraints, environmental conditions, or other plant-specific aspects. There are many different significant and insignificant parameters driving the uncertainty. Additionally, the uncertainty of the different input data used in the fire modeling could have a significant or insignificant effect on the entire plant risk. A four-step methodology was developed to perform Integrated Probabilistic Risk Assessment Importance Ranking. A demonstration case using these steps was set up and three of the four steps were completed in fiscal year (FY) 2019 and the fourth step done FY 2020. These steps are: 1. The qualitative analysis of potential sources was conducted with the following items identified for the demonstration. • Maximum heat release rate • Time to maximum heat release rate • Duration of max heat release rate • Time to decay • Thermal conductivity of concrete • Specific heat of concrete • Density of concrete • Cable jacket thickness 2. A quantitative characterization of dominant sources of uncertainty was performed. A list of distributions and determined values of the dominant sources is shown in Appendix A. 3. A quantitative screening of the potential sources of uncertainty using Morris Elementary Effects Analysis was completed. An experimental model using the physics-based fire modeling tool Fire Dynamics Simulator was developed and coupled with the Risk Analysis Virtual Environment. The Morris analysis identified at least two parameters that can be eliminated as significant contributors (specific heat of concrete and cable jacket thickness). 4. Global importance measure (Global IM) analysis to generate a comprehensive ranking based on their influence on the plant risk. In this research, a moment-independent Global IM is used since it can address (a) uncertainty in the input parameters of the fire model, (b) uncertainty in the risk outputs, and (c) non-linearity and interactions among input parameters in the fire model, more accurately than the correlation-based and variance-based global methods. The observations from the research showed that, depending on the initial and boundary conditions of the fire scenarios, fire-induced damage could have a very small probability and could be dominated by the tail of the uncertainty distribution; hence, the accuracy of the correlation-based and variance-based methods is questionable. The moment-independent Global IM analysis in this research provides a better understanding of how experimental uncertainty data affects industry’s plant models and where improvements in that data will have the largest benefit for improving fire modeling accuracy in causing core damage. Among the five unscreened parameters obtained from the Morris EE analysis, the Global IM analysis results for the case study indicated that max heat release rate and fire location are the most important parameters. The report also outlines benefits of using a unified computational platform that integrates the underlying simulations (e.g., a fire progression model), quantitative screening (using the Morris EE method), and the Global IM analysis. A unified platform can (i) facilitate the ranking of input parameters considering multiple key fire scenarios simultaneously, rather than considering one scenario at a time, (ii) contribute to more explicit and accurate treatment of dependencies at multiple levels of Fire PRA, (iii) facilitate the sampling-based uncertainty quantification for Fire PRA, and (iv) help generating both “industry-wide” and "plant-specific" ranking of uncertainty sources in Fire PRA. Future research should be done to include additional parameters such as detection/suppression or cable fire spread. Adding a PRA software such as SAPHIRE to the RAVEN platform would help with plant model integration and improve treatment of fire-induced dependency. The I-PRA risk importance ranking methodology offered in this report can provide valuable information for efficiently (a) enhancing the realism of Fire PRA for existing plants and (b) supporting the development of Dynamic Fire PRA for advanced reactors and new plants.

97 MATHEMATICS AND COMPUTING↗

ZPPR-15 Small Reactivity Worth Experiments

In addition to measuring the worth of sodium voiding and the worth of simulated control rods, the ZPPR staff measured the Doppler worth of four standard samples, the worth of axial expansion and the worth of radial bowing in ZPPR-15. Doppler sample worths were measured in ZPPR-15A, ZPPR-15B and ZPPR-15D. The Doppler samples were natural UO 2 , depleted uranium metal, depleted U-10Zr alloy and 33% enriched UO 2 . These samples were placed in a sample capsule in the inner core of ZPPR-15 and heated to various temperatures between 300 K and 1100 K. The resulting changes in reactivity relative to the reference configuration were measured to determine the Doppler worths of the samples. Special segmented drawers were constructed to measure the worth of axial expansion in ZPPR15. The segments were connected to each other, and the back segment was connected to a spring-loaded cable. Pulling the cable introduced small gaps between drawer segments to simulate axial expansion, and releasing the cable eliminated those gaps. The worth of this simulated axial expansion was measured in ZPPR-15A, ZPPR-15B and ZPPR-15D. The worth of radial bowing was measured in ZPPR-15, but the experimenters regarded the result as unsatisfactory. Radial bowing was measured by two methods in ZPPR-17A, so the ZPPR-17A bowing measurements were analyzed in place of the unpublished ZPPR-15 radial bowing measurement. The first ZPPR-17A measurement consisted of rearranging the plates in 96 core drawers at the core-radial blanket boundary to simulate outward motion of the fuel during bowing. The second ZPPR-17A measurement used a new bowing oscillator to move the core plates a small distance vertically in a special drawer. The published uncertainties for the Doppler worth, axial expansion worth and radial bowing worth measurements are the statistical uncertainties in the measurements. In reality, the published uncertainty for each of these measurements is just one component of the total uncertainty. There are additional uncertainties specific to each measurement and a common uncertainty related to conversion from the natural measurement units, cents, to pcm for calculations. A full uncertainty analysis was performed for each measurement. The significant uncertainties were quantified, and a total uncertainty was determined for each measurement. The ZPPR-15 and ZPPR-17A experimental records were used to create detailed as-built Monte Carlo models of the Doppler worth, axial expansion and radial bowing measurement configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fork Union EPC Installation Observation Report

On June 22nd and 23rd, a representative from Savannah River National Lab (SRNL) traveled to the Fork Union substation in Fork Union, Virginia (owned and operated by Dominion Energy) to observe the installation, calibration, and commissioning of three Electric Phenomena Cluster (EPC) sensors. The installation in its entirety included the physical securing of the EPC sensors by Dominion Energy, fiber optic cable (furnished by SmartSenseComm) being run in conduits and cable trays from the EPC sensor to the Optical Processing Unit (OPU) located in the substation switch house. The location of the EPC sensors, OPU, and cable routing can be seen in the figures included.

47 OTHER INSTRUMENTATION↗

Integration of Wireless Sensor Networks and Battery-free RFID for Advanced Reactors

To address an important need for Nuclear Power Plants (NPPs) to significantly reduce the amount of the required cables for sensor data communications, this Phase I SBIR effort successfully developed and demonstrated a novel low-cost proof-of-concept prototype of a secure wireless sensor network backbone communications system. This system combines commercially available low power, low cost XBEE wireless communications network and passive (battery-free) Radio Frequency Identification (RFID) systems to report individual sensor data and their location through the containment wall for rapid response to anomalies in nuclear facilities. This WIreless Sensing and Locating (WISLO) system network architecture allows non-intrusive wireless collection of sensor data with the sensor’s accurate location information from inside of the instrumentation or containment area with minimal need for power sources. The multi-node sensor data in the containment area is wirelessly transmitted to outside through the metal reinforced concrete walls without the need for any batteries. The WISLO system could be readily used in current reactor fleet and future advanced reactors, as well as in small modular reactors (SMR). The WISLO system is the first dual frequency battery-free trough the wall communications backbone system developed specifically for use in nuclear power plants. It not only can modernize the sensor monitoring practices in the existing reactor fleet, but also offers a secure, low-cost solution to advanced reactors and SMRs by removing cables and issues related to them such as cable integrity, reporting delays, and installation and maintenance costs. The intent is to improve process safety, reliability, efficiency, and cost effectiveness to the monitoring and maintenance process in current and future plants. As we address the next productization and manufacturing capabilities in the next phase, this system will serve the needs of many commercial and government applications in remote monitoring of sensor data that demand battery-free transmission of sensor data such as Internet-of-Things (IOT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

302.2.03 Report on P43OL1139

This document describes the quality issues encountered in bare cable P43OL1139AA00A fabrication and the subsequent investigation performed at LBNL. The cable concerned was placed under L3 quarantine (braiding held, further QC required) in December 2020 upon fabrication due to mid-run facet size increase, and was elevated to L2 quarantine in February 2020 to require a more formal reporting and resolution. The approval (rejection) of this report by L2 on DocDB shall constitute acceptance (rejection) of the fabrication of the bare cable unit P43OL1139AA00A, upon which it may (may not) proceed to braiding and EVMS HO.

36 MATERIALS SCIENCE↗

Dual Triggered Beam Extraction Kicker (Rev. 1)

A Blumlein modulator is a relatively inexpensive pulsed power device that can deliver highly repeatable pulses that can be used to change the path of beam pulses. The modulator is primarily built with transmission line cable which is relatively inexpensive. Due to the highly repeatable nature of a Blumlein modulator it is a great tool for kicking beam pulses while producing very little spill or losses in beam current. One of the challenges with a Blumlein kicker is that the length of the kicking pulse output by the modulator is determined by the length of the cables. Cable lengths are set prior to implementation for the desired kicking pulse width. The Blumlein modulator at LANSCE uses a single thyratron which can deliver two 50-kilovolt 1,000-amp pulses of opposite polarity to kicking plates at the same time. This method makes for a very strong kick that is highly repeatable. A method that has been discussed, to deliver a different pulse width, is to add a second trigger that would be fired, once the desired pulse width has been delivered, cutting out the remaining pulse. The second trigger would offer a lot of variability with the pulse width of the kicker. This method has only ever been attempted using low current and relatively low voltages compared to the scale needed to properly kick a beam pulse. This in turn allows for the use of power supplies with a higher repetition rate. The advancement of this standard kicker technology in the accelerator facilities would attract attention within the scientific and engineering communities. The project detailed within will investigate the capabilities of different triggering topologies and design a prototype dual triggered Blumlein kicker modulator capable of variable kicking pulse width.

43 PARTICLE ACCELERATORS↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Testing high-current superconducting subscale dipole coils with superconducting transformer

Several sub-scale superconducting dipole coils are being developed at Fermilab in the framework of the U.S. Magnet Development Program. These coils are made of high-current LTS and HTS cables with maximum currents of up to 10 kA. A superconducting current transformer with a maximum DC current up to ~25 kA previously developed at Fermilab for Nb3Sn Rutherford cable testing was modified and adapted for small dipole coil testing. This paper describes its commissioning using a NbTi dipole magnet impregnated with TELENE. This magnet was wound out of 6/1 NbTi cable.

Barzi, Emanuela↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid Cycling ReBCO Dipole Magnet Concept for Muon Acceleraion

We present a concept of the rapid-cycling 1.7 T ReBCO magnet for 1 to 10 kT/s ramping range as required for muon acceleration in a future muon collider presently under study. This approach is based on the 6 kA CORC-like cable constructed with 12 superconducting ReBCO tapes of 2 mm width. Based on theoretical prediction there is a linear scaling of the ReBCO cable hysteresis loss with the crossing magnetic field possibly generating power loss independent of the magnetic field ramping speed. This feature makes this ReBCO cable suitable for the construction of rapid-cycling magnets. In this work we outline the design of a dipole magnet for 1.7 T gap magnetic field and discuss the helium coolant parameters for the minimal electric power.

Piekarz, Henryk [Fermilab] (ORCID:0000000194225662↗

Development of an Unmanned Mobile Current Turbine Platform: Preprint

The design and development of a prototype unmanned mobile floating platform, equipped with a custom low-flow marine current turbine for autonomously seeking and harnessing tidal/coastal currents is described. The platform is an unmanned surface vehicle in the form of a catamaran with two electric outboard motors and capabilities for autonomous navigation. An undershot water wheel, aided by a custom flow concentrator, has been selected as the basic design for the marine current turbine, which is mounted on the stern of the unmanned surface vehicle platform. The concept of operation is that the platform would navigate to a designated marine current resource, autonomously anchor at the location, align itself in the current and deploy the current turbine using a custom cable-lift deployment mechanism. As the turbine harnesses the local current, an onboard power-take-off device converts the harnessed mechanical energy to electricity which is stored in onboard batteries. Considerations of deployment in tidal and coastal waters required obtaining the necessary environmental permits for conducting in-water testing; developing required mitigation measures in protecting local wildlife and their habitats; and identifying potential in-water test sites and surveying them for their suitability in terms of the current resource, bottom type, water depth, and local boat traffic. The design and development of the turbine and the results of initial in-water testing are discussed. The potential for scaling up the system for extended capacity is presented.

ENGINEERING,TIDAL AND WAVE POWER↗

Rapid-cycling ReBCO dipole magnet concept for muon acceleration

We present a concept of the rapid-cycling 1.7 T ReBCO magnet for 1 to 10 kT/s ramping range as required for muon acceleration in a future muon collider presently under study. This approach is based on the 6 kA CORC-like cable constructed with 12 superconducting ReBCO tapes of 2 mm width. Based on theoretical prediction there is a linear scaling of the ReBCO cable hysteresis loss with the crossing magnetic field possibly generating power loss independent of the magnetic field ramping speed. This feature makes this ReBCO cable suitable for the construction of rapid-cycling magnets. In this work we outline the design of a dipole magnet for 1.7 T gap magnetic field and discuss the helium coolant parameters for the minimal electric power.

Piekarz, Henryk [Fermilab] (ORCID:0000000194225662↗

Advanced radio frequency sensing probe

A radio-frequency probe system with a transmitting or receiving element integrated into a cable assembly is disclosed. In some embodiments a preferred configuration may contain one or more sensing elements integrated into the transmitting or receiving element. In another embodiment, the radio frequency probe comprises an antenna body fixed to a coaxial cable, in which the center conductor of the coaxial cable serves as the transmitting or receiving element. A method for monitoring, transmitting, or detecting one or more parameters using a single radio frequency probe is also disclosed.

Sappok, Alexander↗

Communication systems and methods

A communication system is provided that includes a first quantum key distribution device configured to be coupled to a second quantum key distribution device over a quantum channel that communicates a quantum state via the quantum channel, a classical device coupled to the first quantum key distribution device with a connection cable to provide a communication path between the classical device and the first quantum key distribution device, and a quantum channel carrier engaging the connection cable. The quantum channel carrier is configured to, responsive to movement of the connection cable, disrupt a quantum state within the quantum channel.

Bush, Stephen Francis↗

Luminescence based fiber optic probe for the detection of rare earth elements

The disclosure relates to an apparatus, method and process for detecting rare earth elements. The system includes an LED powered by a first power source and a focusing lens in optical communication with the LED. A shortpass filter is in optical communication with the focusing lens; and a fiber bifurcated cable in optical communication with the shortpass filter. The system includes a probe tip in optical communication with the fiber bifurcated cable and a sample; a first aspheric lens in optical communication with the fiber bifurcated cable. A longpass filter is in optical communication with the first aspheric lens and a second aspheric lens in optical communication with the longpass filter. The system includes a spectrometer connected to a power source, where the spectrometer is in optical communication with the second aspheric lens.

Ahern, John C.↗