Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High-temperature flat-conductor cable

Temperature limit of 25-conductor signal cable and 3-conductor power cable, fabricated using woven and roll laminated technique, increased from 200 C to 350 C when polyimide/fluorinated ethylene propylene or polytetrafluoroethylene insulation films and fluorinated ethylene propylene as adhesive medium is applied.

Rigling, W. S.↗

Design and fabrication of the 20 km/10 kV electromechanical tether for TSS-1 using high impact conductor (Hiwire)

The development of a 20-km electromechanical tether for the tethered satellite system (TSS) is described. The basic design requirements for electromagnetic cables and for conductors in cables subject to stresses and cyclic loading are discussed. The tether fabricatioon procedures involve: (1) conductor twisting around the core, (2) insulation extrusion, (3) strength member braiding, and (4) protective jacket braiding.

Scala, E.↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Splicing shielded cables

Simple repair technique retains cable characteristic impedance. Shielded-Cable Splicing Technique retains cable characteristic impedance. Procedure involves splicing inner conductors in staggered pattern, installing jumper braid by heat-shrinking two solder sleeves, and placing insulation sleeve over repaired section and heat-shrinking it. Two possible insulation materials are modified polyvinylidene fluoride and polytetrafluoroethylene.

Lind, W. P.↗

Galileo internal electrostatic discharge program

The Galileo spacecraft which will orbit Jupiter in 1988 will encounter a very harsh environment of energetic electrons. These electrons will have sufficient energy to penetrate the spacecraft shielding, consequently depositing charges in the dielectric insulating materials or ungrounded conductors. The resulting electric field could exceed the breakdown strength of the insulating materials, producing discharges. The transients produced from these Internal Electrostatic Discharges (IESD) could, depending on their relative location, be coupled to nearby cables and circuits. These transients could change the state of logic circuits or degrade or even damage spacecraft components, consequently disrupting the operation of subsystems and systems of the Galileo spacecraft during its expected mission life. An extensive testing program was initiated for the purpose of understanding the potential threats associated with these IESD events. Data obtained from these tests were used to define design guidelines.

Leung, P. L.↗

The analysis and measurement of composite coil properties of Jefferson Lab's super high momentum spectrometer (SHMS) superconducting magnet coils

Jefferson Lab's 11 GeV/c Super High Momentum Spectrometer's superconducting cosine(2theta) quadrupole magnets and the cosine(theta) dipole use a Nb-Ti, 36-strand Rutherford style cable wave-solder to a copper extruded substrate as their conductor. These magnets will operate at 4.4 K. Accurate analysis of the mechanical performance of the magnets under Lorentz forces and thermal stresses requires that the composite coil's physical properties at cryogenic temperatures be known. The composite coil design details including the geometry, components, epoxy glass, and its electrical insulation will be presented. The derivation of the composite coil's calculated physical properties values, using a mixing rule and by Finite Element Analysis (FEA) modeling of a sample coil will be given. The calculated values will be compared to recent measured values of representative samples of the composite coils. Comparison of the composite built up coil sample, measurements and calculated values will be discussed

36 MATERIALS SCIENCE↗

Measurements of Electrical and Electron Emission Properties of Highly Insulating Materials

Highly insulating materials often acquire significant charges when subjected to fluxes of electrons, ions, or photons. This charge can significantly modify the materials properties of the materials and have profound effects on the functionality of the materials in a variety of applications. These include charging of spacecraft materials due to interactions with the severe space environment, enhanced contamination due to charging in Lunar of Martian environments, high power arching of cables and sources, modification of tethers and ion thrusters for propulsion, and scanning electron microscopy, to name but a few examples. This paper describes new techniques and measurements of the electron emission properties and resistivity of highly insulating materials. Electron yields are a measure of the number of electrons emitted from a material per incident particle (electron, ion or photon). Electron yields depend on incident species, energy and angle, and on the material. They determine the net charge acquired by a material subject to a give incident flu. New pulsed-beam techniques will be described that allow accurate measurement of the yields for uncharged insulators and measurements of how the yields are modified as charge builds up in the insulator. A key parameter in modeling charge dissipation is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across an insulator, as well as the time scale for charge transport and dissipation. Comparison of new long term constant-voltage methods and charge storage methods for measuring resistivity of highly insulating materials will be compared to more commonly used, but less accurate methods.

Dennison, J. R.↗

Folding tool for preparing FCC molded-plug terminations

Assemblies consist of window piece, conductor spacer, insulator, outer seal, and molded portion that integrates all components. Preparation of FCC for molded plug termination requires that terminated ends of conductors in each cable be accurately folded simultaneously into spacer end and groove.

Campbell, E. C.↗

Design, Test and Demonstration of Fault Current Limiting HTS Transformer

The project developed new technology that enables the creation of a high temperature superconductor-based FCL power transformer. SuperPower’s research and development created new methods to bond HTS conductor to a supporting substrate, test, and insulate the resulting bonded conductor, reduce winding ac losses, ensure FCL functionality during a transformer fault and build firm superconducting joints in the transformer harnesses and cabling. The bonded conductor in this program was shown to meet the critical operating parameters of providing the superconducting transformer operation while being able to meet the target normal state resistance required for FCL operation. The bonded conductor was also shown to be able to handle the fabrication stresses associated with the manufacture of the FCL transformer while also being able to handle the high hoop stresses and axial forces during a fault transient. Much of the technology developed here is applicable to the broader applied superconductivity community. The ability to tailor the clad conductors performance characteristics gives the designer of devices utilizing HTS a broader capability to address the particular needs of an given application. SuperPower worked with its sub-recipients Waukesha Electric Systems, ORNL, Southern California Edison and University of Houston to develop the design, fabrication, installation and operational aspects of a fault current limiting transformer on the electrical grid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep Charging Evaluation of Satellite Power and Communication System Components

A set of deep charging tests has been carried out by NASA's Marshall Space Flight Center on subscale flight-like samples developed by Space Systems/Loral, LLC. The samples, which included solar array wire coupons, a photovoltaic cell coupon, and a coaxial microwave transmission cable, were placed in passive and active (powered) circuit configurations and exposed to electron radiation. The energy of the electron radiation was chosen to deeply penetrate insulating (dielectric) materials on each sample. Each circuit configuration was monitored to determine if potentially damaging electrostatic discharge events (arcs) were developed on the coupon as a result of deep charging. The motivation for the test, along with charging levels, experimental setup, sample details, and results will be discussed.

Schneider, T. A.↗

Grounding Headphones for Protection Against ESD

A simple alternative technique has been devised protecting delicate equipment against electrostatic discharge (ESD) in settings in which workers wear communication headsets. In the original setting in which the technique was devised, the workers who wear the headsets also wear anti-ESD grounding straps on their wrists. The alternative technique eliminates the need for the wrist grounding straps by providing for grounding through the headsets. In place of the electrically insulating foam pads on the headsets, one installs pads made of electrically conductive foam like that commonly used to protect electronic components. Grounding wires are attached to the conductive foam pads, then possibly to the shielding cable which may be grounded to the backshell on the connector. The efficacy of this technique in protecting against ESD has been verified in experiments. The electrical resistance of the pads is a few megohms - about the same as that of a human body between the fingers of opposite hands and, hence, low enough for grounding. The only drawback of the technique is that care must be taken to place the foam pads in contact with the user s skin: any hair that comes between the foam pads and the skin must be pushed aside because hair is electrically insulating and thus prevents adequate grounding.

Peters, John↗

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

Evaluation of Cable Harness Post-Installation Testing

The Cable Harness Post-Installation Testing Report was written in response to an action issued by the Ares Project Control Board (PCB). The action for the Ares I Avionics & Software Chief Engineer and the Avionics Integration and Vehicle Systems Test Work Breakdown Structure (WBS) Manager in the Vehicle Integration Office was to develop a set of guidelines for electrical cable harnesses. Research showed that post-installation tests have been done since the Apollo era. For Ares I-X, the requirement for post-installation testing was removed to make it consistent with the avionics processes used on the Atlas V expendable launch vehicle. Further research for the report involved surveying government and private sector launch vehicle developers, military and commercial aircraft, spacecraft developers, and harness vendors. Responses indicated crewed launch vehicles and military aircraft perform post-installation tests. Key findings in the report were as follows: Test requirements identify damage, human-rated vehicles should be tested despite the identification of statistically few failures, data does not support the claim that post-installation testing damages the harness insulation system, and proper planning can reduce overhead associated with testing. The primary recommendation of the report is for the Ares projects to retain the practice of post-fabrication and post-installation cable harness testing.

King, M. S.↗

Progresses in Developing Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

Development of the novel patented high voltage insulation system, namely micro-multilayer multifunctional electrical insulation (MMEI) was continued particularly for the future hybrid or all electric aircraft applications. Initially, the concept and feasibility of the MMEI system were successfully demonstrated with its exceptionally high dielectric breakdown voltage via optimizing the multilayer structures of the Kapton® PI films and binder layers such as PFA in terms of individual film thickness and layer configuration. Overall, MMEI structures outperformed most of the state-of-the-art (SOA) polymer insulation materials or structures. Since then, further optimizations and improvement of the system were pursued with specific emphasis on multifunctionalities such as moisture blocking, partial discharge (PD) resistance, durability, etc. Efforts have been also continued to identify the controlling mechanisms for the major improvement in dielectric strength of the MMEI structures via 3-dimensional dielectric failure mode analysis. At the same time, significant progress has been made in scaling up the MMEI structures and assessing their commercial applicability and manufacturability by developing full-scale prototypes of electrical components, such as power cable and bus bar. Overall progresses on the MMEI development to date will be presented in this paper.

Novel Electrical Insulation↗

Flat conductor cable connector with contact separation seal

Cable connector is developed in which each pair of contact elements is isolated by plastic cells and the mating interface is sealed by an elastic gasket. So insulated, the connector may be operated under high vacuum conditions at voltages up to 600 V ac without electrical leakage or intercontact ionization.

Angele, W.↗

Construction challenges and solutions in TAMU3, a 14 T stress-managed Nb{sub 3}Sn dipole

The Accelerator Research Laboratory at Texas A and M University is nearing completion of a Nb{sub 3}Sn dipole that incorporates stress management directly in its windings. The windings utilize graded-cross-section cable made from 54/61 (54 out of a 61 subelement hexagonal pattern) Restacked Rod Processed® Nb{sub 3}Sn/Cu conductor and fine-filament S-2 glass fabric insulation. Coil heat treatment and associated differential expansions have brought about some tin leakage, highresistance electrical shorts, and coil gaps. TAMU3b impregnation successfully increased the coil-to-ground resistance. Quench protection in TAMU3 was simulated using QUENCH. The tests of TAMU3 should provide the first examination of stress management at field intensities greater than 12 T.

43 PARTICLE ACCELERATORS↗