Search NASA⌕ Search

SEARCH · Search NASA

Results for “code compliance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Data Sciences Summer Institute Topology Optimization

DSSI_TOPOPT is a 2D topology optimization code that designs stiff structures made of a single linear elastic material and void space. The code generates a finite element mesh of a rectangular design domain on which the user specifies displacement and load boundary conditions. The code iteratively designs a structure that minimizes the compliance (maximizes the stiffness) of the structure under the given loading, subject to an upper bound on the amount of material used. Depending on user options, the code can evaluate the performance of a user-designed structure, or create a design from scratch. Output includes the finite element mesh, design, and visualizations of the design.

Watts, Seth↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

Energy Codes, code compliance↗

An Estimate of Residential Energy Savings From IECC Change Proposals Recommended for Approval at the ICC’s Fall, 2009, Initial Action Hearings

DOE has established ambitious goals to improve the energy-efficiency requirements of the International Energy Conservation Code (IECC) for residential buildings. DOE has established near- and long-term goals of 30% and 50% energy-efficiency improvements, respectively, compared to the 2006 IECC. This report presents DOE’s approach to calculating residential energy consumption for the purpose of estimating energy savings attributable to improvements in the code. This approach is then used to estimate the national average energy savings, relative to the 2006 IECC, resulting from the proposed improvements DOE submitted and supported for the 2012 IECC. DOE estimates a total reduction in energy use of 30.6% for the projected requirements of the 2012 IECC as compared to the 2006 IECC, assuming the use of the primary compliance option that involves standard-efficiency equipment. Were the high-equipment efficiency option used, the projected savings would be 0.9% higher, at 31.5%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simple, accurate surrogate models of the elastic response of three-dimensional open truss micro-architectures with applications to multiscale topology design

Elastic meta-materials are those whose unique properties come from their micro-architecture, rather than, e.g., from their chemistry. The introduction of such architecture, which is increasingly able to be fabricated due to advances in additive manufacturing, expands the design domain and enables improved design, from the most complex multi-physics design problems to the simple compliance design problem that is our focus. Unfortunately, concurrent design of both the micro-scale and the macroscale is computationally very expensive when the former can vary spatially, particularly in three dimensions. Instead, we provide simple, accurate surrogate models of the homogenized linear elastic response of the isotruss, the octet truss, and the ORC truss based on high-fidelity continuum finite element analyses. These surrogate models are relatively accurate over the full range of relative densities, in contrast to analytical models in the literature, which we show lose accuracy as relative density increases. The surrogate models are also simple to implement, which we demonstrate by modifying Sigmund’s 99-line code to solve a three-dimensional, multiscale compliance design problem with spatially varying relative density. Here, we use this code to generate examples in both two and three dimensions that illustrate the advantage of elastic meta-materials over structures with a single length scale, i.e., those without micro-architectures.

42 ENGINEERING↗

Benchmarking the New RESRAD-OFFSITE Source Term Model with DUST-MS and GoldSim - 13377

RESRAD-OFFSITE is a computer code developed by Argonne National Laboratory under the sponsorship of U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC). It is designed on the basis of RESRAD (onsite) code, a computer code designated by DOE and NRC for evaluating soil-contaminated sites for compliance with human health protection requirements pertaining to license termination or environmental remediation. RESRAD-OFFSITE has enhanced capabilities of modeling radionuclide transport to offsite locations and calculating potential radiation exposure to offsite receptors. Recently, a new source term model was incorporated into RESRAD-OFFSITE to enhance its capability further. This new source term model allows simulation of radionuclide releases from different waste forms, in addition to the soil sources originally considered in RESRAD (onsite) and RESRAD-OFFSITE codes. With this new source term model, a variety of applications can be achieved by using RESRAD-OFFSITE, including but not limited to, assessing the performance of radioactive waste disposal facilities. This paper presents the comparison of radionuclide release rates calculated by the new source term model of RESRAD-OFFSITE versus those calculated by DUST-MS and GoldSim, respectively. The focus of comparison is on the release rates of radionuclides from the bottom of the contaminated zone that was assumed to contain radioactive source materials buried in soil. The transport of released contaminants outside of the primary contaminated zone is beyond the scope of this paper. Overall, the agreement between the RESRAD-OFFSITE results and the DUST-MS and GoldSim results is fairly good, with all three codes predicting identical or similar radionuclide release profiles over time. Numerical dispersion in the DUST-MS and GoldSim results was identified as potentially contributing to the disagreement in the release rates. In general, greater discrepancy in the release rates was found for short-lived, fast-moving radionuclides than for long-lived, slow-moving radionuclides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IDAES-PSE 2.1.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.1.0 Release Highlights New IDAES Examples Repository Starting with this release, the IDAES examples are developed in the new IDAES/examples repository. Along with many content and usability improvements, the most significant changes are: To install the examples, after installing IDAES, run pip install idaes-examples The idaes get-examples command, previously used for this, has been removed The HTML version is now available at https://idaes-examples.readthedocs.io The previous URL, https://idaes.github.io/examples-pse, will not be updated and may be removed at some point in the future For more details, refer to the resources available at IDAES/examples. Removal of Non-Functional Apps A review of the code in the idaes/apps and idaes/models_extra folders was undertaken, and a number of tools were identified as being outdated or non-functional and no longer supported by their development teams. Due to this, the following tools have been removed: idaes/apps/alamopy_depr (note that the new ALAMOpy interface remains avaialble in idaes/core/surrogates) idaes/apps/helmet idaes/apps/ripe idaes/apps/roundingRegression idaes/models_extra/carbon_capture Pyomo 6.6 This version of IDAES is the first requiring Pyomo 6.6. This version of Pyomo contains multiple internal improvements and refactorings. While for the majority of cases this should have positive or no impact on solvability of IDAES models, we are aware of a small number of models that have been affected as a result of these changes. For more information, refer to the Pyomo 6.6.1 release notes. Other highlights Model Initialization A prototype API for a new approach to initializing IDAES models is now available which makes available some new techniques for initializing models. This is documented in the Initializing Models Reference Guide Modular Properties Framework Support for some transport properties Helmholtz Equation of State properties Better error checking for case where unit models are set to include phase equilibrium but the property package is set to support only a single phase Multi-Stream Contactor model: a new base model for systems involving contacting of two or more streams with mass transfer. This model is intended to be used as the foundation for models such as membrane separators, solvent extraction and other similar processes. This is documented in the Multi-Stream Contactor Reference Guide idaes/models_extra/power_generation report() methods for unit models using Helmholtz equation of state General Code Maintenance Streamlining of dependencies and creation of new optional dependency groupings to support non-core tools General linting of codebase to ensure compliance with most pylint checks Spell checking of all code and doc strings Removal of backward compatibility code for Python 2

IDAES↗

beam loss scenarios for MuCool Test Area

The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets, gas-filled RF cavities, and other apparatus being developed to cool intense, large-emittance muon beams. In this study the results of Monte Carlo modeling of several beam loss scenarios are presented. The MTA facility was designed to test targets and other muon cooling apparatus using the intense Fermilab Linac beam. The requested intensity of the proton beam for the MTA is essentially full Linac capability, or 1.6 x 10{sup 13} protons per pulse and an energy of 400 MeV. Two modes of operation will be supported in the MuCOOL beamline: one mode for emittance measurements (and beamline studies) and a second mode for MTA experiments. Maximum beam intensity for these two modes is: 9.6 x 10{sup 15} protons/hr - 600 beam pulses/hour of full Linac beam pulse intensity (1.6 x 10{sup 13} protons/pulse) to the emittance beam absorber and 9.6 x 10{sup 14} protons/hour - 60 beam pulses/hour of full Linac beam pulse intensity to experiments in the MTA experimental hall. This extremely high intensity implies careful investigation into and application of proper shielding materials and configuration in order to satisfy the following two requirements: (i) to reduce the instantaneous dose rate outside of the experimental enclosure to prescribed levels appropriate for the area considered; (ii) to ensure the civil construction of the hall is capable of additional shielding and, further, that the weight of the shielding is commensurate with the loading specifications of the enclosure, notably the ceiling. A number of scenarios for beam loss at different locations were studied in order to determine the maximum beam intensity which is in compliance with the existing shielding. The modeling was performed with the MARS15 code.

43 PARTICLE ACCELERATORS↗

Fire Protection Engineering Design Brief Template: Hydrogen Refueling Station

Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

08 HYDROGEN↗

Los Alamos National Laboratory Floodplain Assessment for Fire Risk Mitigations at the Lower Slobbovia Testing Site in (TA-36)

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take fire pre-suppression actions at Los Alamos National Laboratory (LANL) Technical Area (TA) 36. Constructing a fire break and a fuel break surrounding the Lower Slobbovia explosives testing site in addition to the current vegetation mowing practices would establish a safety perimeter to help prevent fires from spreading away from the firing point. NNSA has prepared this floodplain assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Floodplain and Wetland Environmental Review Requirements (10 CFR 1022), which was promulgated to implement DOE requirements under Executive Order 11988 Floodplain Management (EO 1977). A floodplain is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base floodplain as “the 100-year floodplain, that is, a floodplain with a 1.0 percent chance of flooding in any given year (CFR 2003).” This floodplain assessment evaluates potential impacts to floodplain values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Los Alamos National Laboratory Wetland Assessment for the Replacement Water Lines from Technical Area 48 to Technical Area 55 Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take action at Los Alamos National Laboratory (LANL) near a wetland at Technical Area (TA) 48 and under a wetland at TA-55. The project proposes to install two 12-inch water lines along an alignment from TA-48 to Pecos Road on the east side of TA-55 (Figure 1). The proposed water lines will replace aging cast iron pipes that provide water for fire suppression to buildings within TA-55, and potable water to other areas in the Pajarito Corridor. NNSA has prepared this wetland assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Wetland and Wetland Environmental Review Requirements (10 CFR Part 1022) (CFR 2003) which was promulgated to implement DOE requirements under Executive Order 11988 Wetland Management (EO 1977). A wetland is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base wetland as “the 100-year wetland, that is, a wetland with a 1.0 percent chance of flooding in any given year (CFR 2003).” This wetland assessment evaluates potential impacts to wetland values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 8 to Technical Area 22 Natural Gas Line Replacement Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction that crosses through upper Pajarito Canyon and upper Starmer Canyon from Technical Area (TA) 8 to TA-22 at Los Alamos National Laboratory (LANL). The project proposes to install a new 12 inch natural gas line to replace the existing 70+ year old natural gas line. Replacement will prevent loss of service to several LANL TAs and Bandelier National Monument. The project activities within the 100- year floodplains include 1) new natural gas line installation to replace and existing aging gas line, 2) relocating a section of fence and 3) three construction equipment and materials storage areas. NNSA has prepared this floodplain assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Floodplain and Wetland Environmental Review Requirements (10 CFR Part 1022) (CFR 2003) which was promulgated to implement DOE requirements under Executive Order 11988 Floodplain Management (EO 1977). A floodplain is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base floodplain as “the 100-year floodplain, that is, a floodplain with a 1.0 percent chance of flooding in any given year (CFR 2003).” This floodplain assessment evaluates potential impacts to floodplain values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Technical Manual and User's Guide for MILDOS, Version 4.1

The MILDOS computer code is used to estimate the radiological impacts of airborne emissions from uranium mining and milling facilities. The code allows users to consider both conventional uranium ore operations and operations associated with in situ recovery (ISR) facilities. The code is used by license applicants and U.S. Nuclear Regulatory Commission staff to perform routine radiological impact and compliance evaluations for various uranium recovery operations. As part of a major code update, the following improvements and additions were made to the code: (a) revised ISR models, (b) support for ores containing thorium-232 (Th-232) and its daughter radionuclides in addition to the currently supported uranium-238 (U-238) and its daughter radionuclides, (c) a revised area source model, (d) the capability to perform sensitivity analysis on specific input parameters, (e) the capability to use current meteorological data provided by the National Climatic Data Center, and (f) an interactive results module.

54 ENVIRONMENTAL SCIENCES↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVELOPMENT OF A NEW TYPE A(F)RADIOACTIVE MATERIAL PACKAGING FOR THE DEPARTMENT OF ENERGY

In a coordinated effort, the Department of Transportation (DOT) and Nuclear Regulatory Commission (NRC) proposed the elimination of the Specification Packaging from 49 CFR 173.[1] In accordance with the Federal Register, issued on October 1, 2004, new fabrication of Specification Packages would no longer be authorized. In accordance with the NRC final rulemaking published January 26, 2004, Specification Packagings are mandated by law to be removed from service no later than October 1, 2008. This coordinated effort and resulting rulemaking initiated a planned phase out of Specification Type B and Type A fissile (F) material transportation packages within the Department of Energy (DOE) and its subcontractors. One of the Specification Packages affected by this regulatory change is the UN1A2 Specification Package, per DOT 49 CFR 173.417(a)(6). To maintain continuing shipments of DOE materials currently transported in UN1A2 Specification Package after the existing authorization expires, a replacement Type A(F) material packaging design is under development by the Savannah River National Laboratory. This paper presents a summary of the prototype design effort and testing of the new Type A(F) Package development for the DOE. This paper discusses the progress made in the development of a Type A Fissile Packaging to replace the expiring 49 CFR UN1A2 Specification Fissile Package. The Specification Package was mostly a single-use waste disposal container. The design requirements and authorized radioactive material contents of the UN1A2 Specification Package were defined in 49 CFR. A UN1A2 Specification Package was authorized to ship up to 350 grams of U-235 in any enrichment and in any non-pyrophoric form. The design was specified as a 55-gallon 1A2 drum overpack with a body constructed from 18 gauge steel with a 16 gauge drum lid. Drum closure was specified as a standard 12-gauge ring closure. The inner product container size was not specified but was listed as any container that met Specification 7A requirements per 49 CFR 178.350. Specification 7A containers were required to withstand Type A packaging tests required by 49CFR173.465 with compliance demonstrated through testing, analysis or similarity to other containers. The maximum weight of the 7A product container, the radioactive content, and any internal packaging was limited to 200 lbs. The total gross weight for the UN1A2 Specification Package was limited to 350 lbs. No additional restrictions were applied. Authorization for use did not require the UN1A2 Specification Package to be tested to the Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) required for performance based, Type A(F) packages certified by the NRC or DOE. The Type A(F) Packaging design discussed in this paper is required to be in compliance with the regulatory safety requirements defined in Code of Federal Regulations (CFR) 10 CFR 71.41 through 71.47 and 10 CFR71.71. Sub-criticality of content must be maintained under the Hypothetical Accident Conditions specified under 10 CFR71.73. These federal regulations, and other applicable DOE Orders and Guides, govern design requirements for a Type A(F) package. Type A(F) packages with less than an A2 quantity of radioactive material are not required to have a leak testable boundary. With this exception a Type A(F) package design is subject to the same test requirements set forth for the design of a performance based Type B packaging.

36 MATERIALS SCIENCE↗

PolyMat: an efficient Matlab code for multi-material topology optimization

We introduce a Matlab implementation of topology optimization for compliance minimization on unstructured polygonal finite element meshes that efficiently accommodates many materials and many volume constraints. Leveraging the modular structure of the educational code, PolyTop, we extend it to the multi-material version, PolyMat, with only a few modifications. First, a design variable for each candidate material is defined in each finite element. Next, we couple a Discrete Material Optimization interpolation with the existing penalization and introduce a new parameter such that we can employ continuation and smoothly transition from a convex problem without any penalization to a non-convex problem in which material mixing and intermediate densities are penalized. Mixing that remains due to the density filter operation is eliminated via continuation on the filter radius. To accommodate flexibility in the volume constraint definition, the constraint function is modified to compute multiple volume constraints and the design variable update is modified in accordance with the Zhang-Paulino-Ramos Jr. (ZPR) update scheme, which updates the design variables associated with each constraint independently. The formulation allows for volume constraints controlling any subset of the design variables, i.e., they can be defined globally or locally for any subset of the candidate materials. Borrowing ideas for mesh generation on complex domains from PolyMesher, we conclude which design variables are associated with each local constraint of arbitrary geometry. A number of examples are presented to demonstrate the many material capability, the flexibility of the volume constraint definition, the ease with which we can accommodate passive regions, and how we may use local constraints to break symmetries or achieve graded geometries.

79 ASTRONOMY AND ASTROPHYSICS↗

Annual Change Report 2006/2007

As part of continuing compliance, the U.S. Environmental Protection Agency (EPA) requires the U.S. Department of Energy (DOE) to provide information on any change in conditions or activities pertaining to the disposal system since the most recent compliance application. This requirement is identified in Title 40 Code of Federal Regulations (CFR), Section 194.4(b)(4), which states: "No later than six months after the administrator issues a certification, and at least annually thereafter, the Department shall report to the Administrator, in writing, any changes in conditions or activities pertaining to the disposal system that were not required to be reported by paragraph (b)(3) of this section and that differ from information contained in the most recent compliance application." In meeting the requirement, the DOE provides an annual report each November of all applicable changes under the above requirement. This annual report informs the EPA of changes to information in the most recent compliance recertification (the 2004 Compliance Recertification). Significant planned changes must be reported to the EPA prior to implementation by the DOE. In addition, Title 40 CFR, Section 194.4(b)(3) requires that significant unplanned changes be reported to the EPA within 24 hours or ten days, depending on the severity of the activity or condition. To date, there have been no significant unplanned changes to the certification basis. Planned changes have been submitted on an individual basis. All other changes are reported annually. Changes in activities or conditions are reviewed to determine if 40 CFR Section 194.4(b)(3) reporting is necessary. As indicated above, no significant unplanned changes were identified for the time period covered by this report. The enclosed tables list those items identified for reporting under 40 CFR Section 194.4(b)(4). The majority of the items described in this report are inspections, reports, and modifications to written plans and procedures for WIPP operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗