Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Benzotriazole‐Based Nonfused Ring Acceptors for Efficient and Thermally Stable Organic Solar Cells

Abstract Nonfused ring acceptors (NFRAs) have attracted significant attention for nonfullerene organic solar cells (OSCs) owing to their chemical tunability and facile synthesis. In this study, a benzotriazole‐based NFRA with chlorinated end groups (Triazole‐4Cl) is developed to realize highly efficient and thermally stable NFRA‐based OSCs; an analogous NFRA with nonchlorinated end groups (Triazole‐H) is synthesized for comparison. Triazole‐4Cl film exhibits the high‐order packing structure and the near‐infrared absorption capability, which are advantageous in charge transport and light harvesting of the resulting OSCs. In particular, the strong crystalline behavior of Triazole‐4Cl results in enhanced self‐aggregation, leading to high charge carrier mobility. Owing to these properties, a PBDB‐T (polymer donor):Triazole‐4Cl OSC demonstrates a high short‐circuit current, fill factor, and power conversion efficiency (PCE = 10.46%), outperforming a PBDB‐T:Triazole‐H OSC (PCE = 7.65%). In addition, the thermal stability of a PBDB‐T:Triazole‐4Cl OSC at an elevated temperature of 120 °C exceeds that of a PBDB‐T:Triazole‐H OSC. This is mainly attributed to the significantly higher cold crystallization temperature of Triazole‐4Cl (205.9 °C). This work provides useful guidelines for the design of NFRAs to achieve efficient and thermally stable NFRA‐based OSCs.

Polymer Science↗

Southern Ocean Low Cloud and Precipitation Phase Observed During the Macquarie Island Cloud and Radiation Experiment (MICRE)

Shallow cloud decks residing in or near the boundary layer cover a large fraction of the Southern Ocean (SO) and play a major role in determining the amount of shortwave radiation reflected back to space from this region. In this article, we examine the macrophysical characteristics and thermodynamic phase of low clouds (tops <3 km) and precipitation using ground-based ceilometer, depolarization lidar and vertically-pointing W-band radar measurements collected during the Macquarie Island Cloud and Radiation Experiment (MICRE) from April 2016 to March 2017. During MICRE, low clouds occurred ~65% of the time on average (slightly more often in austral winter than summer). About 2/3 of low clouds were cold-topped (temperatures ≤0°C). These were thicker and had higher bases on average than warm-topped clouds. 83%–88% of cold-topped low clouds were liquid phase at cloud base (depending on the season). The majority of low clouds had precipitation in the vertical range 150–250 m below cloud base, a significant fraction of which did not reach the surface. Phase characterization is limited to the period between April 2016 and November 2016. Small-particle (low-radar-reflectivity) precipitation (which dominates precipitation occurrence) was mostly liquid below-cloud, while large-particle precipitation (which dominates total accumulation) was predominantly mixed/ambiguous or ice phase. Approximately 40% of cold-topped clouds had mixed/ambiguous or ice phase precipitation below (with predominantly liquid phase cloud droplets at cloud base). Below-cloud precipitation with radar reflectivity factors below about -10 dBZ were predominantly liquid, while reflectivity factors above about 0 dBZ were predominantly ice.

54 ENVIRONMENTAL SCIENCES↗

Planar temperature measurement in compressible flows using laser-induced iodine fluorescence

A laser-induced iodine fluorescence technique that is suitable for the planar measurement of temperature in cold nonreacting compressible air flows is investigated analytically and demonstrated in a known flow field. The technique is based on the temperature dependence of the broadband fluorescence from iodine excited by the 514-nm line of an argon-ion laser. Temperatures ranging from 165 to 245 K were measured in the calibration flow field. This technique makes complete, spatially resolved surveys of temperature practical in highly three-dimensional, low-temperature compressible flows.

Hartfield, Roy J., Jr.↗

Subscale Injector Testing to Support Ares Engines Development

The J-2X and RS-68B rocket engines are being developed for NASA's Ares I and Ares V launch vehicles. In support of the development of these engines, hot-fire testing on subscale coaxial injectors has been performed at NASA s Marshall Space Flight Center (MSFC) to evaluate performance data relative to injector type, liquid oxygen (LOX) post tip design features, element density and various operating conditions. Shear coaxial injectors with element densities of 1.1, 1.6, and 2.3 elements/in2 and a swirl coaxial injector with element density of 1.6 elements/in2 were evaluated at conditions relevant to the Ares applications. Chamber pressures with oxygen/hydrogen propellants ranged from 815-1630 psig with mixture ratios ranging from 4.7-6.9. Fuel manifold inlet temperatures were varied from 90 to 270 R. Shear coaxial LOX post tip thicknesses ranged from 0.006 in. to 0.0175 in. Modular, water cooled, calorimeter chamber assemblies were used to provide heating rate data and evaluate the effects of characteristic length (L*). Performance was evaluated relative to the resulting characteristic velocity (C*) efficiency. Testing with both the 2.3 and 1.1 elements/in2 shear coaxial injectors demonstrated no improvement in performance of the "thin" tip configuration versus the "thick" tip configuration. The loss in chamber pressure and associated performance loss seen in previous testing at low fuel temperatures could not be reliably repeated, indicating that this loss is not the result of a fluidic process in the injector elements. Further, no performance loss could be demonstrated once a faceplate seal specifically designed for operation with low temperature hydrogen was implemented in the 1.1 elements/sq in shear coaxial injector. Results for the 1.6 elements/sq in swirl injector at cold fuel temperatures showed performance higher than both the 1.6 elements/in2 shear coaxial injector and the 2.3 elements/in2 shear coaxial injector.

Protz, Christopher↗

Adavanced RTG and thermoelectric materials study

A comprehensive, generalized two-dimensional RTG analysis computer program was developed. This program is capable of analyzing any specified RTG design under a wide range of transient as well as steady-state operating conditions. The feasibility of a new concept for the design of segmented (or single-phase) thermoelectric couples was demonstrated. A SiGe-PbTe segmented couple involving pressure contacted junctions at the intermediate- and hot-junction temperatures was successfully encapsulated in a hermetically sealed bellows enclosure. This bellows-encapsulated couple was operated between a hot- and cold-junction temperature of 1200 K and 450 K, respectively, with a measured energy conversion efficiency of 7.6 + or - .5 per cent. An experimental study of selected sublimation barrier schemes revealed that a significant reduction in the sublimation rate of p-type PbTe could be achieved by using multiple layers of SiO2 fibers. A comparison of the barrier effectiveness is given for three different barrier designs.

Eggers, P. E.↗

Aridity-Dependent Land Surface Skin Temperature Biases in CMIP5/6

Land surface skin temperature, a critical indicator of climate change, connects the water and energy cycles between the land and the atmosphere. Here, in this study, we evaluate the simulations of land surface skin temperature from the Coupled Model Intercomparison Project Phase 5 (CMIP5) and CMIP6 models with satellite-based datasets and reanalysis. We find systematic cold skin temperature biases over arid regions in CMIP5/CMIP6 simulations. Over arid and semi-arid regions, latent heat biases drive skin temperature biases by evaporative cooling. Over humid regions, surface downward shortwave and albedo biases are relatively more critical. Spatial patterns of biases remain similar in the latest CMIP6 simulations, suggesting systematic biases in land-atmosphere interactions. These biases need to be corrected or considered while using models for future projections.

54 ENVIRONMENTAL SCIENCES↗

Applications of a Venus thermospheric circulation model

A variety of Pioneer Venus observations suggest a global scale, day-to-night Venus thermospheric circulation. Model studies of the dynamics and energetics of the Venus thermosphere are presented in order to address new driving, mixing and cooling mechanisms for an improved model simulation. The adopted approach was to reexamine the circulation by first using a previous two dimensional code to quantify those physical processes which can be inferred from the Pioneer Venus observations. Specifically, the model was used to perform sensitivity studies to determine the degree to which eddy cooling, eddy or wave drag, eddy diffusion and 15 micrometer radiational cooling are necessary to bring the model temperature and composition fields into agreement with observations. Three EUV heating cases were isolated for study. Global temperature and composition fields in good agreement with Pioneer data were obtained. Large scale horizontal winds 220 m/s were found to be consistent with the observed cold nightside temperatures and dayside bulges of O, CO and CO2. Observed dayside temperatures were obtained by using a 7 to 19% EUV heating efficiency profile. The enhanced 15 micrometer cooling needed for thermal balance is obtained using the best rate coefficient available for atomic O collisional excitation of CO2(0,1,0). Eddy conduction was not found to be a viable cooling mechanism due to the weakened global circulation. The strong 15 micrometer damping and low EUV efficiency imply a very weak dependence of the general circulation to solar cycle variability. The NCAR terrestrial thermospheric general circulation model was adapted for Venus inputs using the above two dimensional model parameters, to give a three dimensional benchmark for future Venus modelling work.

Bougher, S. W.↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Mesoscale analysis of VAS 6.7 micron image data for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Mesoscale analysis of 6.7 micron image data from the VISSR Atmospheric Sounder (VAS) for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Silicon-On-Insulator (SOI) Devices and Mixed-Signal Circuits for Extreme Temperature Applications

Electronic systems in planetary exploration missions and in aerospace applications are expected to encounter extreme temperatures and wide thermal swings in their operational environments. Electronics designed for such applications must, therefore, be able to withstand exposure to extreme temperatures and to perform properly for the duration of the missions. Electronic parts based on silicon-on-insulator (SOI) technology are known, based on device structure, to provide faster switching, consume less power, and offer better radiation-tolerance compared to their silicon counterparts. They also exhibit reduced current leakage and are often tailored for high temperature operation. However, little is known about their performance at low temperature. The performance of several SOI devices and mixed-signal circuits was determined under extreme temperatures, cold-restart, and thermal cycling. The investigations were carried out to establish a baseline on the functionality and to determine suitability of these devices for use in space exploration missions under extreme temperatures. The experimental results obtained on selected SOI devices are presented and discussed in this paper.

Patterson, Richard↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The lower hybrid density drift instability with cold plasma

The linear Vlasov dispersion relation for the lower hybrid density drift instability is studied in a four component (hot electrons and protons, cold electrons and protons) plasma. The introduction of a cold ion population monotonically reduces the maximum growth rate of the instability. Reduction of the ratio of temperatures of the cold and hot plasmas reduces both the real frequency and the growth rate of the instability. Near a ratio of the cold and hot plasma temperatures of 0.01 a higher frequency branch of this instability emerges and for a fixed ratio of cold and hot electron density exhibits an increasing maximum growth rate as the ratio of the cold and hot plasma temperatures decreases further. The ratio of the cold and hot plasma temperatures for the ions is the crucial parameter and deserves detailed magnetospheric studies.

Gary, S. P.↗

Dynamics of the Cold Water Event off the Southeast Coast of the United States in the Summer of 2003: An Application of NASA's Remote Sensing Data to Coastal Studies

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard of Terra and Aqua satellites provide, for the first time, concurrent measurements of sea surface temperature (SST) and ocean color, which are suitable for coastal upwelling studies. The accuracy, the 1-km spatial resolution, and the almost complete daily coverage of the MODIS data compared with historical measurements make it advantageous for resolving important coastal fronts of chlorophyll concentration and temperature. The cold SST anomaly during summer 2003 off the coast of the South Atlantic Bight is an event that is comprehensively covered by NASA's MODIS and SeaWinds satellite observations. These data combined with in situ tide gauge, mooring, and ship measurements can be used to identify important dynamics responsible for the anomalous cold water event. The analysis of the data suggests that coastal upwelling occurs in the climatological summer forced by the climatological southerlies over the South Atlantic Bight area in summer. However, the strong buoyancy barrier in summer prevents the cold water below the thermocline from reaching the ocean surface. In summer 2003, the southwesterlies in July through August were extraordinarily strong and persistent, which generated the upwelling currents strong enough to overcome the buoyancy resistance. The results of this analysis demonstrate the possibility of monitoring and forecasting the event using combination of the satellite and in situ observations. The MODIS data are archived and distributed by the NASA's Goddard Earth Science (GES) Distributed Active Archive Center (DAAC). The data can be accessed via the URL http://wwv.daac.gsfc.nasa.gov/MODIS.

Yuan, Dongliang↗

Testing of the Mars Exploration Rovers to Survive the Extreme Thermal Environments

Both Rovers have celebrated 3-year anniversaries on surface of Mars: a) More than ten times design life; b) Planned and implemented rigorous assembly and system level test programs; c) Demonstrated robust thermal margins; d)Tested both in vacuum and Mars atmosphere; e) Planned and implemented thermal cycling life qualification program; f) Demonstrated survival in deep thermal diurnal cycling and seasonal temperature variations; and g) Both Rovers continue to explore and return valuable science data

thermal environments↗

A Contaminant Ice Visualization Experiment in a Glass Pulse Tube

Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapor contamination of the helium working gas. The experiments were conducted in a glass pulse tube to enable visualization of ice formation on internal surfaces. Photographs of this ice formation were taken along with simultaneous coldtip temperature and compressor power measurements. Four types of regenerator elements were tested in various combinations: 200- and 400-mesh stainless steel screens, 1.6 mm diameter glass beads, and 1.6 mm thick perforated plastic plates. Internal spacers were also used to provide clear fields of view into the regenerator stack. Substantial water-ice formation was observed at the cold end of the regenerator and on the inside wall of pulse tube; it appeared to be highly porous, like snow, and was seen to accumulate only in a very localized region at the coldest end, despite changing the cold tip temperature across a range of 150 to 235 K. Ice formation degraded pulse tube thermal performance only in cases where screen regenerators were used at the regenerator cold end. It was concluded that flow blockage was the mechanism by which contaminants affected performance; coarse regenerator elements were largely immune over the tested time scale of a few days. Substantially reduced ice formation and minimal performance loss were also observed in repeated tests where the contaminated gas was reused after warming up and melting of the accumulated internal ice. Significant adsorption of the liquid water onto the regenerator was inferred, a process that depleted the gas phase concentration of water.

Hall, J. L.↗

Seasonal variation of atmospheric nitric acid over the South Pole in 1992

We conducted year-around measurements of mid infrared atmospheric emission over the South Pole in 1992. We were able to observe a large seasonal change of the total column of nitric acid (HNO3) vapor. During the summer the HNO3 column abundance was about 2 x 10(exp 16) molecules/sq cm. There was a small increase in the fall. A rapid decrease of 50% was observed in late June, soon after the stratospheric temperature reached the threshold for formation of type I polar stratospheric clouds (PSCs). By early July, the stratospheric temperature was cold enough to form type II PSCs, and the HNO3 column decreased to 7 x 10(exp 15) molecules/sq cm. Measured nitric acid values in the spring remained extremely low even after the stratosphere warmed well above PSC temperatures. This may indicate permanent removal of HNO3 by gravitational settling, or long-term sequestering in large particles. Normal summer values were not observed until the vortex dissipated and allowed the lateral transport of HNO3 to the south polar region.

Allen, Renate Van↗