Commissioning a Miniature Multileaf Collimator for Small Field Radiotherapy

The aim of this study was to determine dosimetric data for the Siemens ModuLeaf miniature multileaf collimator. Acquiring accurate data for small fields requires careful evaluation of different measurement techniques and dosimeters. Output factors were measured using several different detectors. Comparing these results demonstrated the relative under-response of the devices as the field size approaches the active area of the detector. Measurements obtained with a diamond detector, radiographic film, 0.125 cm{sup 3} cylindrical and advanced Markus ionization chambers agreed (within 0.7%) down to a field size of 2 x 2 cm. For smaller field sizes, only the diamond detector and the film agreed within their relative uncertainties. Head scatter factors were measured in brass and Perspex miniphantoms using the cylindrical chamber positioned at the isocenter, and in the Perspex miniphantom at extended distances. For field sizes of less than 3 x 3 cm, only the measurements with the brass miniphantom at the isocenter and the Perspex miniphantom at extended distances agreed (within 0.8%). The effect on the miniphantom measurements of using a low scatter support stand was also quantified. Beam profiles were measured using radiographic film. An unexpected artifact was found in these images because of increased backscatter from white lines inscribed and painted on the phantom. Percentage depth doses (PDDs) measured with and without the ModuLeaf attached agreed for all field sizes down to 3 x 3 cm. Below this field size, tissue maximum ratios (TMRs) were measured using an advanced Markus chamber. The 3 x 3 cm ModuLeaf TMR data agreed with the non-ModuLeaf PDD data within their relative uncertainties. This study investigated the use of several different measurement methods from which accurate dosimetric parameters can be obtained without the need to acquire specialist detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impacts of Multileaf Collimators Leaf Width on Intensity-Modulated Radiotherapy Planning for Nasopharyngeal Carcinoma: Analysis of Two Commercial Elekta Devices

We compared the impacts of multileaf collimator (MLC) widths (standard MLC width of 10 mm [SMLC] and micro-MLC width of 4 mm [MMLC]) on intensity-modulated radiotherapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Ten patients with NPC were recruited in this study. In each patient's case, plans were generated with the same machine setup parameter and optimizing methods in a treatment planning system according to 2 commercial Elekta MLC devices. All of the parameters were collected from dose-volume histograms of paired plans and evaluated. The average conformity index (CI) and homogeneous index (HI) for the planning gross target volume in IMRT plans with MMLC were 0.790 {+-} 0.036 and 1.062 {+-} 0.011, respectively. Data in plans with SMLC were 0.754 {+-} 0.038 and 1.070 {+-} 0.010, respectively. The differences were statistically significant (p < 0.05). Compared with CI and HI for planning target volume in paired plans, data with MMLC obviously were better than those with SMLC (CI: 0.858 {+-} 0.026 vs. 0.850 {+-} 0.021, p < 0.05; and HI: 1.185 {+-} 0.011 vs. 1.195 {+-} 0.011, p < 0.05). However, there was no statistical significance between evaluated parameters (Dmean, Dmax, D{sub 5}, gEUD, or NTCP) for organs at risk (OARs) in the 2 paired IMRT plans. According to these two kinds of Elekta MLC devices, IMRT plans with the MMLC have significant advantages in dose coverage for the targets, with more efficiency in treatment for NPC but fail to improve dose sparing of the OARs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Static jaw collimation settings to minimize radiation dose to normal brain tissue during stereotactic radiosurgery

At University of Arkansas for Medical Sciences (UAMS) intracranial stereotactic radiosurgery (SRS) is performed by using a linear accelerator with an add-on micromultileaf collimator (mMLC). In our clinical setting, static jaws are automatically adapted to the furthest edge of the mMLC-defined segments with 2-mm (X jaw) and 5-mm (Y jaw) margin and the same jaw values are applied for all beam angles in the treatment planning system. This additional field gap between the static jaws and the mMLC allows additional radiation dose to normal brain tissue. Because a radiosurgery procedure consists of a single high dose to the planning target volume (PTV), reduction of unnecessary dose to normal brain tissue near the PTV is important, particularly for pediatric patients whose brains are still developing or when a critical organ, such as the optic chiasm, is near the PTV. The purpose of this study was to minimize dose to normal brain tissue by allowing minimal static jaw margin around the mMLC-defined fields and different static jaw values for each beam angle or arc. Dose output factors were measured with various static jaw margins and the results were compared with calculated doses in the treatment planning system. Ten patient plans were randomly selected and recalculated with zero static jaw margins without changing other parameters. Changes of PTV coverage, mean dose to predefined normal brain tissue volume adjacent to PTV, and monitor units were compared. It was found that the dose output percentage difference varied from 4.9-1.3% for the maximum static jaw opening vs. static jaw with zero margins. The mean dose to normal brain tissue at risk adjacent to the PTV was reduced by an average of 1.9%, with negligible PTV coverage loss. This dose reduction strategy may be meaningful in terms of late effects of radiation, particularly in pediatric patients. This study generated clinical knowledge and tools to consistently minimize dose to normal brain tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of the number of control points has on isodose distributions in a dynamic multileaf collimator intensity-modulated radiation therapy delivery

Intensity-modulated radiation therapy (IMRT) is a powerful technique in planning the delivery of dose. The most common IMRT delivery requires the use of moving multileaf collimators (MLCs) to deliver the requested fluence pattern. A dynamic delivery IMRT field file will contain several control points that are defined MLC shapes at a marked fraction of the delivered monitor units. The size of this file and the fidelity of the deliverable fluence are proportional to the number of control points defined. This study investigates the effect of reducing the number of control points has on the resultant dose distribution quality in complex IMRT in efforts to reduce transfer times, loading times, check sum times and file storage. Analysis was performed with 6 head and neck patients on an Eclipse version 8.5 treatment planning system (Varian, Palo Alto, CA). To ensure the quality of all treatments, Eclipse defines a minimum of 64 and a maximum of 320 control points per subfield (Eclipse Algorithms Reference guide). All 6 patients' plans were calculated with fixed 64, 166, and 320 control points using the sliding window technique. In addition, each plan was calculated in variable mode (Normal mode) in which the planning system determined the required number of control points. Each of the 4 plans for each patient was renormalized to provide the same mean planning target volume (PTV) 70 dose. Dose values for critical and target structures were examined for each patient. When examining the minimum, maximum, and mean doses to all target structures, it was noted that the greatest reduction in target dose coverage caused by reduced number of control points was 0.5%, which occurred for the minimum dose to the PTV56 structure in one plan.' Dose analysis for critical structures showed no clinically significant increase in dose when compared with the 320 control point plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer

To study the effect of multileaf collimator (MLC) leaf widths (standard MLC [sMLC] width of 10 mm and micro-MLC [mMLC] width of 4 mm) on intensity-modulated radiotherapy (IMRT) for cervical cancer. Between January 2010 and August 2010, a retrospective analysis was conducted on 12 patients with cervical cancer. The treatment plans for all patients were generated with the same machine setup parameters and optimization methods in a treatment planning system (TPS) based on 2 commercial Elekta MLC devices. The dose distribution for the planning tumor volume (PTV), the dose sparing for organs at risk (OARs), the monitor units (MUs), and the number of IMRT segments were evaluated. For the delivery efficiency, the MUs were significantly higher in the sMLC-IMRT plan than in the mMLC-IMRT plan (802 ± 56.9 vs 702 ± 56.7; p < 0.05). The number of segments in the plans were 58.75 ± 1.8 and 59 ± 1.04 (p > 0.05). For the planning quality, the conformity index (CI) between the 2 paired IMRT plans with the mMLC and the sMLC did not differ significantly (average: 0.817 ± 0.024 vs 0.810 ± 0.028; p > 0.05). The differences of the homogeneity index (HI) between the 2 paired plans were statistically significant (average: 1.122 ± 0.010 vs 1.132 ± 0.014; p < 0.01). For OARs, the rectum, bladder, small intestine, and bony pelvis were evaluated in terms of V{sub 10}, V{sub 20}, V{sub 30}, and V{sub 40}, percentage of contoured OAR volumes receiving 10, 20, 30, and 40 Gy, respectively, and the mean dose (D{sub mean}) received. The IMRT plans with the mMLC protected the OARs better than the plans with the sMLC. There were significant differences (p < 0.05) in evaluated parameters between the 2 paired IMRT plans, except for V{sub 30} and V{sub 40} of the rectum and V{sub 10}, V{sub 20}, V{sub 40}, and D{sub mean} of the bladder. IMRT plans with the mMLC showed advantages over the plans with the sMLC in dose homogeneity for targets, dose sparing of OARs, and fewer MUs in cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multileaf collimator tongue-and-groove effect on depth and off-axis doses: A comparison of treatment planning data with measurements and Monte Carlo calculations

To investigate how accurately treatment planning systems (TPSs) account for the tongue-and-groove (TG) effect, Monte Carlo (MC) simulations and radiochromic film (RCF) measurements were performed for comparison with TPS results. Two commercial TPSs computed the TG effect for Varian Millennium 120 multileaf collimator (MLC). The TG effect on off-axis dose profile at 3 depths of solid water was estimated as the maximum depth and the full width at half maximum (FWHM) of the dose dip at an interleaf position. When compared with the off-axis dose of open field, the maximum depth of the dose dip for MC and RCF ranged from 10.1% to 20.6%; the maximum depth of the dose dip gradually decreased by up to 8.7% with increasing depths of 1.5 to 10 cm and also by up to 4.1% with increasing off-axis distances of 0 to 13 cm. However, TPS results showed at most a 2.7% decrease for the same depth range and a negligible variation for the same off-axis distances. The FWHM of the dose dip was approximately 0.19 cm for MC and 0.17 cm for RCF, but 0.30 cm for Eclipse TPS and 0.45 cm for Pinnacle TPS. Accordingly, the integrated value of TG dose dip for TPS was larger than that for MC and RCF and almost invariant along the depths and off-axis distances. We concluded that the TG dependence on depth and off-axis doses shown in the MC and RCF results could not be appropriately modeled by the TPS versions in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Can cost make a difference dosimetrically? Volumetric modulated arc therapy study for multileaf collimators of various widths for head and neck and prostate cancers

Cancer is a global health issue that disproportionately kills based on stage of disease, cellular pathology, and genetics, to name a few. Another variable to consider in this ongoing fight is treatment machine complexity that leads to elevated development and purchasing cost, leading to a reduced use. Reducing the complexity (in hopes of lowering costs) would benefit underdeveloped, low- and middle-income countries by introducing newer treatment technology, as their currently accepted standards do not meet standards of more advanced, developed countries. In this study, unilateral head and neck (H&N), and prostate cases using volumetric modulated arc therapy (VMAT) were tested with multiple segment widths of 5, 10, 15, and 20 mm to create treatable plans. Pinnacle 9.10v was used for planning purposes. A total of 12 cases were planned with varying multileaf collimator (MLC) widths. Treatment plans were evaluated retrospectively. Results show that altering the MLC widths from 5 through 20 mm produces both comparable and treatable plans up to 99% and 98% target coverage for H&N and prostate, respectively, albeit clinically significant hot spots were shown to increase with increasing segment width. Furthermore, the results show that increasing widths can produce comparable treatment plans as measured against our current Food and Drug Administration (FDA)–approved treatment devices—leading to an increase in treatment efficacy in economically underdeveloped countries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors

This work aimed to study the dosimetric effect of multileaf collimator (MLC) leaf widths in treatment plans for patients receiving volumetric modulated arc therapy (VMAT) for spine stereotactic body radiation therapy (SBRT). Thirteen patients treated with spine SBRT were retrospectively selected for this study. The patients were treated following the protocol of the Radiation Therapy Oncology Group 0631 (RTOG 0631) for spine metastasis. The prescription dose was 16 Gy in 1 fraction to 90% of the target volume (V16 > 90%). The maximum spinal cord dose of 14 Gy and 10% of the spinal cord receiving < 10 Gy (V10) were the acceptable tolerance doses. For the purpose of this study, 2 dual-arc VMAT plans were created for each patient using 3 different MLC leaf widths: 2.5 mm, 4 mm, and 5 mm. The compliance with the RTOG 0631 protocol, conformity index (CI), dose gradient index (DGI), and number of monitor units (MUs) were compared. The average V16Gy of the targets was 91.8 ± 1.2%, 92.2 ± 2.1%, and 91.7 ± 2.3% for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively (p = 0.78). Accordingly, the average CI was 1.45 ± 0.4, 1.47 ± 0.29, and 1.47 ± 0.31 (p = 0.98), respectively. The average DGI was 0.22 ± 0.04, 0.20 ± 0.06, and 0.22 ± 0.05, respectively (p = 0.77). The average maximum dose to the spinal cord was 12.45 ± 1.0 Gy, 12.80 ± 1.0 Gy, and 12.48 ± 1.1 (p = 0.62) and V10% of the spinal cord was 3.6 ± 2.1%, 5.6 ± 2.8%, and 5.5 ± 3.0% (p = 0.11) for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively. Accordingly, the average number of MUs was 4341 ± 500 MU, 5019 ± 834 MU, and 4606 ± 691 MU, respectively (p = 0.053). The use of 2.5-mm, 4-mm, and 5-mm MLCs achieved similar VMAT plan quality as recommended by the RTOG 0631. The dosimetric parameters were also comparable for the 3 MLCs. In general, any of these leaf widths can be used for spine SBRT using VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radial modes of laterally stiffened piezoelectric disc transducers for ultrasonic collimated beam generation

Here, we numerically investigate the resonance and vibration characteristics of radial modes of laterally stiffened piezoelectric disc transducers. Lateral stiffening is modeled using a spring and vibration characteristics of the piezo-disc are investigated with increasing lateral stiffness. It is found that the resonant frequency response of the radial modes follows an asymptotic behavior approaching that of a clamped disc with increasing lateral stiffness. The radial mode vibration pattern of the discs is also found to be affected by lateral stiffness. While the vibration pattern of a free disc corresponds to a Bessel function, laterally stiffened discs show edge-effects where they depart from the Bessel-like behavior. In addition, a fully clamped piezo-disc is found to have an extra side-lobe when compared to a free disc. Ultrasonic beam profiles generated from radial modes of laterally stiffened discs are numerically investigated. It is found that the free piezo-disc generates a Bessel beam that has multiple side-lobes. Increasing the lateral stiffness results in a significant reduction of side-lobes in the beam profile. This technique of generating a collimated beam with side-lobe reduction finds significant applications in imaging through concrete, drilling mud, and other highly attenuating materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and Simulations on Scattered Gamma-Ray Imaging without Collimator

Scattered radiation by Compton effect in emission imaging has been considered increasingly as active agent instead of being treated as noise and being rejected. In a recent proposal, scattered radiation emitted by the object under investigation and detected by a collimated gamma camera was shown to provide the capability to reconstruct the object in three dimensions. The acquisition of the scattered radiation with an uncollimated detector would enhance drastically sensitivity and resolution. This paper proposes a formal model for the image formation in this new imaging process. Monte-Carlo simulations validate the forward model and are used as data for numerical reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of Multihole Collimator Gamma Camera Simulation Modeled Using MCNP5

This paper describes the characteristics of the multihole collimator gamma camera that is simulated using the combination of the Monte Carlo N-Particles Code (MCNP) version 5 and in-house software. The model is constructed based on the GCA-7100A Toshiba Gamma Camera at the Royal Surrey County Hospital, Guildford, Surrey, UK. The characteristics are analyzed based on the spatial resolution of the images detected by the Sodium Iodide (NaI) detector. The result is recorded in a list-mode file referred to as a PTRAC file within MCNP5. All pertinent nuclear reaction mechanisms, such as Compton and Rayleigh scattering and photoelectric absorption are undertaken by MCNP5 for all materials encountered by each photon. The experiments were conducted on Tl-201, Co-57, Tc-99 m and Cr-51 radio nuclides. The comparison of full width half maximum value of each datasets obtained from experimental work, simulation and literature are also reported in this paper. The relationship of the simulated data is in agreement with the experimental results and data obtained in the literature. A careful inspection at each of the data points of the spatial resolution of Tc-99 m shows a slight discrepancy between these sets. However, the difference is very insignificant, i.e. less than 3 mm only, which corresponds to a size of less than 1 pixel only (of the segmented detector)00.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly efficient acceleration and collimation of high-density plasma using laser-induced cavity pressure

An efficient scheme of acceleration and collimation of dense plasma is proposed and examined. In the scheme, a target placed in a cavity coupled with a guiding channel is irradiated by a laser beam introduced into the cavity through a hole and accelerated along the channel by the pressure of the ablating plasma confined in the cavity. Using 1.315 mum, 0.3 ns laser pulse of energy up to 200 J and a thin CH target, it was shown that the energetic efficiency of acceleration in this scheme is an order of magnitude higher than in the case of conventional ablative acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long distance fiber-optic displacement sensor based on fiber collimator

A simple fiber-optic displacement sensor based on reflective intensity modulated technology is demonstrated using a fiber collimator. The sensing range is over 30 cm, which is over 100 times that of the conventional fiber-optic displacement sensor based on the normal single-mode fiber. The measured data are fitted into linear equation very well and the values of R-square are more than 0.995. The sensitivity of the device achieves 0.426 dB/cm over the range of 5-30 cm. By applying the relative technique, the errors resulted from the fluctuation of light source and influences of environment are effectively eliminated, and the stability for wide range measurement can be improved. The simplicity of the design, high dynamic range, stability and the ease of the fabrication make it suitable for applications in industries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High efficiency multichannel collimator for structural studies of liquids and low-Z materials at high pressures and temperatures

A high efficiency multichannel collimator (MCC) device has been developed at the high pressure beamline ID27 of the European Synchrotron Radiation Facility to drastically reduce the x-ray background from the sample environment in the Paris-Edinburgh press. The main technical difficulty, which resides in the minimum slits size achievable using the classical mono-bloc design, has been resolved using an original concept based on a set of independent slits. Then, a very small slit size of 50 {mu}m was manufactured resulting in a great improvement of the signal to background ratio. In addition, the transfer function of the MCC has been measured using the x-ray diffusion signal of a metal doped glass and efficiently applied to correct the raw data. The potential of this new device is illustrated in two challenging examples: iron-sulfur liquid structures and C{sub 60} polymerization process at high pressure and high temperature.

43 PARTICLE ACCELERATORS↗

Use of a multichannel collimator for structural investigation of low-Z dense liquids in a diamond anvil cell: Validation on fluid H{sub 2} up to 5 GPa

We report the first application of a multichannel collimator (MCC) to perform quantitative structure factor measurements of dense low-Z fluids in a diamond anvil cell (DAC) using synchrotron x-ray diffraction. The MCC design, initially developed for the Paris-Edinburgh large volume press geometry, has been modified for use with diamond anvil cells. A good selectivity of the diffracted signal of the dense fluid sample is obtained due to a large rejection of the Compton diffusion from the diamond anvils. The signal to background ratio is significantly improved. We modify previously developed analytical techniques for quantitative measurement of the structure factor of fluids in DACs [J. H. Eggert, G. Weck, P. Loubeyre, and M. Mezouar, Phys. Rev. B 65, 174105 (2002)] to account for the contribution of the MCC. We present experimental results on liquids argon and hydrogen at 296 K to validate our method and test its limits, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of optical pulses of duration down to 8 fs upon filamentation of collimated femtosecond laser radiation in argon

A new scheme providing self-compression of femtosecond laser radiation upon filamentation of a collimated beam in argon at a pressure of {approx}0.8 atm is experimentally realised. Pulses with the initial duration of 55 fs were compressed down to 8 fs, the peak power of the compressed pulse exceeding 20 GW. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron beam deflection, focusing, and collimation by a femtosecond laser lens

This work examines spatial separation of femtosecond electron bunches using the ponderomotive potential created by femtosecond laser pulses. It is shown that ponderomotive optical potentials are capable of effectively deflecting, focusing, and collimating narrow femtosecond electron bunches. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation and experimental verification of a collimator with a Kerr lens for fibre laser mode locking

We present the calculation and experimental verification of the operation of a collimator coupling a light beam into an optical fibre with an As{sub 2}S{sub 3} nonlinear plate. It is shown that a Kerr lens formed in the plate with an increase in the peak pulse power leads to an increase in the output coupling ratio by about 15%, which can be used for the passive mode locking of a fibre laser. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗