Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Structurally Driven Selective Adsorption of Hydrocarbons by Metal Substitution in Isostructural Rare-Earth Metal–Organic Frameworks

The design and realization of highly selective nanoporous materials are necessary to target critical separations across industries. By leveraging pore size, pore shape, and linker functionalization, the design of nanoporous solid adsorbents will enable the rapid production of energy efficient separation materials for high-value gas mixtures. This study uses a combination of modeling, synthesis, and gas adsorption testing to investigate a new class of small-pore isostructural rare-earth (RE) 2,5-dihydroxyterephthalic acid (DOBDC) metal–organic frameworks (MOFs) (RE: Pr-, Gd-, Er-, Yb; DOBDC = 2,5-dihydroxyterephthalic acid) and their adsorption selectivity for acetylene/ethylene mixtures. Density functional theory simulations identified that selective binding of acetylene over ethylene in the Gd-, Er-, and Yb-DOBDC MOFs was due to hydrogen-bonding between acetylene and the linker hydroxyl. Adsorption experiments validated the computational results by identifying mechanisms that control the acetylene/ethylene adsorption selectivity and high acetylene adsorption. Furthermore, dynamic column breakthrough experiments with the Gd-DOBDC MOF validated the simulations and indicated that ethylene can be separated from acetylene in a mixture containing 1 vol % acetylene and 39 vol % ethylene (balance argon). In conclusion, the results highlight the complexity of gas binding in functional porous materials and how combining modeling and experiment enables a fundamental understanding of gas–framework interactions that can be leveraged for the design of future separation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Modeling and Process-Materials Co-Optimization Strategies for Swing Adsorption Based Gas Separations

This project devised a computational framework for simultaneously co-optimizing pressure swing adsorption process designs along with the sorbent materials (specifically, metal-organic frameworks) to be employed in the associated packed bed columns. The materials optimization aspect involved search over a design space that can describe the material’s molecular structure, while the process optimization aspect considered various process degrees of freedom for steps arising in various cycle configurations. This framework was demonstrated on the separation of nitrogen and carbon dioxide, which arises ubiquitously in a multitude of post-combustion carbon capture and “blue” hydrogen production applications. Our results led to metal-organic framework molecular descriptor choices that are predicted to outperform standard structures used in practice, providing guidance for future metal-organic framework synthesis efforts.

20 FOSSIL-FUELED POWER PLANTS↗

Ultrasonic in-situ water-cut measurement using ultrasonic oil-water separation for affecting sound speed calibration

An apparatus and method for the separation of an oil-water mixture into its components are described. An acoustic radiation force moves oil droplets to the nodes of an acoustic standing wave generated in a vertical column containing the oil-water mixture. Once the droplets are sufficiently close together, attractive forces become dominant and the droplets may coalesce to form larger droplets, which have greater buoyancy, and separation of the mixture into a layer of oil and a layer of water occurs, not possible by simple gravitational separation. Acoustically-driven oil-water separation may be used for water-cut measurements in oil production wells, since separation of the oil from the water permits accurate sound speed measurements to be made for both the oil and the water, thereby allowing frequent in situ calibrations of the apparatus to determine whether sound speed measurements on the mixture are accurate in the event that one or both of the mixture constituents is changing.

02 PETROLEUM↗

Thermal and oxidative degradation studies of formulated C-ethers by gel-permeation chromatography

Gel-permeation chromatography was used to analyze C-ether lubricant formulations from high-temperature bearing tests and from micro-oxidation tests. Three mu-styragel columns (one 500 and two 100 A) and a tetrahydrofuran mobile phase were found to adequately separate the C-ether degradation products. The micro-oxidation tests yielded degradation results qualitatively similar to those observed from the bearing tests. Micro-oxidation tests conducted in air yielded more degradation than did tests in nitrogen. No great differences were observed between the thermal-oxidative stabilities of the two C-ether formulations or between the catalytic degradation activities of silver and M-50 steel. C-ether formulation I did yield more degradation than did formulation II in 111- and 25-hour bearing tests, respectively.

Jones, W. R., Jr.↗

The Properties of the local Interstellar Medium and the Interaction of the Stellar Winds of epsilon Indi and lambda Andromedae with the Interstellar Environment

We present new observations of the Ly alpha lines of Epsilon Indi (K5 5) and A Andromedae (G8 4-3 + ?) These data were obtained by the Goddard High Resolution Spectrograph (GHRS) on the Hubble Space Telescope. Analysis of the interstellar H 1 and D 1 absorption lines reveals that the velocities and temperatures inferred from the H 1 lines are inconsistent with the parameters inferred from the D 1 lines, unless the H 1 absorption is assumed to be produced by two absorption components. One absorption component is produced by interstellar material. For both lines of sight observed, the velocity of this component is consistent with the velocity predicted by the local flow vector. For the Epsilon Indi data, the large velocity separation between the stellar emission and the interstellar absorption allows us to measure the H 1 column density independent of the shape of the intrinsic stellar Ly alpha profile. This approach permits us to quote an accurate column density and to assess its uncertainty with far more confidence than in previous analyses, for which the errors were dominated by uncertainties in the assumed stellar profiles.

Wood, Brian E.↗

X-Ray Spectral Study of a Newly Ginga-Detected DQ Her

The goal of this proposal was to observe with ASCA, YY Dra, a DQ Her objected identified using archival Ginga data, in order to complete a high quality ASCA study of Ginga-detected DQ Her stars. There are relatively few DQ Her objects characterized by X-ray pulsations at the white dwarf spin period and optical pulsations at the orbital period and extremely complex X-ray spectra. The ASCA study included seven DQ Her objects. ASCA is able to resolve separate components of the Fe K emission and to set constraints on temperatures in the accretion column, and the mass of the white dwarf. The 40ksec observation, corresponding to roughly three orbital cycles, allowed the study of continuum changes with spin and orbital phase. The ASCA spectrum can be modelled as a bremsstrahlung with evidence for cold, helium-like and hydrogen-like iron emission, and helium-like argon emission. The lines yield a plasma temperature that is compatible with that from the continuum modelling (10-20 keV). The X-ray light-curve clearly shows sinusoidal variation from the spin pulse and shallow absorption dips at the orbital cycle. The derived parameters match well with the -accretion curtain, model for intermediate polars. The results will be presented together with the seven other DQ Her type sources observed with ASCA.

Vrtilek, S.↗

FUSE Analysis of the Cyg OB1 Superbubble

FUSE observations of four stars in the line of sight to the Cyg OB1 IR-detected superbubble have been analyzed for high-velocity features in the O VI interstellar lines, which might be attributed to the shock structure of the superbubble. Multiple components were detected in the spectra of all four stars, with a velocity range of -85 kilometers per second to +29 kilometers per second. As many as four separate velocity components were identified in each spectrum, implying multiple shock structures in the superbubble. Derived column densities of the O VI components indicate shock velocities of 160-190 kilometers per second according to steady state shock theory.

Nichols, J.↗

Seizure detection device

A method of detecting a seizure includes collecting volatile organic compounds with a collector material of a collector; separating a mixture of the volatile organic compounds into its constituent chemicals with a gas chromatography column; ionizing the constituent chemicals to create ionized chemicals and detecting the ionized chemicals; and analyzing the ionized chemicals to identify seizure-indicative volatile organic compounds.

Arnold, Gary Stephen↗

Detailed results of ASTP experiment MA-011

This experiment was developed in order to conduct engineering and operational tests of electrokinetic equipment in a micro-gravity environment. The experimental hardware in general functioned as planned and electrophoretic separations were obtained in space. The results indicated the development of satisfactory sample collection, return, and preservation techniques. The application of a near-zero zeta potential interior wall coating to the experimental columns, confirmation of biocompatibility of all appropriate hardware components, and use of a sterile operating environment provided a significant step forward in the development of a biological processing facility in space. A separation of a test of aldehyde-fixed rabbit, human, and horse red blood cells was obtained. Human kidney cells were separated into several components and viable cells returned to earth. The isotachophoretic separation of red cells was also demonstrated. Problems associated with the hardware led to a lack of success in the attempt to separate subpopulations of human lymphocytes.

Seaman, G. V. F.↗

Separation and Detection of Toxic Gases with a Silicon Micromachined Gas Chromatography System

A miniature gas chromatography (GC) system was designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 microliter sample loop; a 0.9 meter long, rectangular shaped (300 micrometer width and 10 micrometer height) capillary column coated with a 0.2 micrometer thick copper phthalocyanine (CuPc) stationary phase; and a dual detector scheme based upon a CuPc-coated chemiresistor and a commercially available 125 micrometer diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex (r) cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts-per-million (ppm) concentrations of ammonia (NH3) and nitrogen dioxide (NO2) when isothermally operated (55-80 degrees C). With a helium carrier gas and nitrogen diluent, a 10 microliter sample volume containing ammonia and nitrogen dioxide injected at 40 psi ((2.8 x 10(exp 5)Pa)) can be separated in less than 30 minutes.

Kolesar, Edward S.↗

Cadmium isotope systematics in sedimentary carbonate: Extending the utility of the cadmium isotope palaeo-productivity proxy

The cadmium (Cd) isotope compositions of seven Holocene (<11.7 ka) carbonate sediments, including the bulk carbonate, as well as the > 140 μm (zooplankton), <63 μm and < 20 μm (phytoplankton) fractions, and individual species of foraminifera isolated from the bulk carbonate were obtained for sub-samples processed using the Cd-cleaning and Mg/Ca cleaning methods. The respective Cd isotope systematics of each carbonate archive were then compared with the Cd isotope signature within the ocean using modern seawater data. We show that a constant Cd isotope fractionation factor of -0.25 ± 0.03 ‰ (2SE, n = 4) describes the partitioning of Cd from seawater into the carbonate phase ($Δ^{114}Cd_{CdC O_3 - seawater}$), allowing for accurate reconstructions of the past seawater nutrient regime. The Cd isotope signature of the < 63 µm and < 20 µm (phytoplankton) fractions can display comparable values to those recorded in the modern surface ocean, and can be used to model the magnitude of Cd uptake and utilisation in the past ocean. Individual species of planktic and benthic foraminifera, which inhabit different depths of the water column, can provide a full surface to deep water column reconstruction of the Cd nutrient regime, while infaunal benthic foraminifera can be used to interrogate the Cd isotope systematics of sediment porewaters. Bulk sediment and the > 140 µm (zooplankton) fraction also retain important information relating to the overlying water column Cd isotope systematics and can serve as essential archives for palaeo-productivity reconstructions where the separation of individual components from the bulk sediment is not possible. This new Cd isotope palaeo-productivity toolkit can considerably aid reconstruction efforts and vastly improves the ability to quantify the role of phytoplankton in modulating carbon sequestration through transitions in Earth’s climate evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BICEP/Keck. XVI. Characterizing Dust Polarization through Correlations with Neutral Hydrogen

We characterize Galactic dust filaments by correlating BICEP/Keck and Planck data with polarization templates based on neutral hydrogen (H i) observations. Dust polarization is important for both our understanding of astrophysical processes in the interstellar medium (ISM) and the search for primordial gravitational waves in the cosmic microwave background (CMB). In the diffuse ISM, H i is strongly correlated with the dust and partly organized into filaments that are aligned with the local magnetic field. We analyze the deep BICEP/Keck data at 95, 150, and 220 GHz, over the low-column-density region of sky where BICEP/Keck has set the best limits on primordial gravitational waves. We separate the H i emission into distinct velocity components and detect dust polarization correlated with the local Galactic H i but not with the H i associated with Magellanic Stream i. We present a robust, multifrequency detection of polarized dust emission correlated with the filamentary H i morphology template down to 95 GHz. For assessing its utility for foreground cleaning, we report that the Hi morphology template correlates in B modes at a ~10%–65% level over the multipole range 20 < ℓ < 200 with the BICEP/Keck maps, which contain contributions from dust, CMB, and noise components. We measure the spectral index of the filamentary dust component spectral energy distribution to be β = 1.54 ± 0.13. We find no evidence for decorrelation in this region between the filaments and the rest of the dust field or from the inclusion of dust associated with the intermediate velocity H i. Finally, we explore the morphological parameter space in the H i-based filamentary model.

79 ASTRONOMY AND ASTROPHYSICS↗

Transparent switchboard

A tin oxide coating is formed on a plate of glass and the coating is then etched away from the glass in thin lines to form separate electrical conductors which extend to one end of the plate and connect to either a vertical (column) or horizontal (row) position sensing SCR circuit. A thin transparent insulating coating is formed over the oxide layer except at selected touch points which are positioned in a matrix pattern of vertical columns and horizontal rows. Touching one of these points with a finger bridges the thin line between adjacent conductors to activate trigger circuits in the particular row and column sensing circuits associated with the point touched. The row and column sensing circuits are similar and are powered with a low frequency, ac voltage source. The source for the row circuits is 180 out of phase with the source for the column circuits so that one circuit acts as ground for the other during half of the supply voltage cycle. The signals from the sensing circuits are input to a logic circuit which determines the presence of a valid touch, stores a binary matrix number associated with the touched point, signals a computer of the presence of a stored number and prevents storage of a new number before receiving an enable signal from the computer.

Rasmussen, H. P.↗

Program Aids In Printing FORTRAN-Coded Output

FORPRINT computer program prints FORTRAN-coded output files on most non-Postscript printers with such extra features as control of fonts for Epson and Hewlett Packard printers. Rewrites data to printer and inserts correct printer-control codes. Alternative uses include ability to separate data or ASCII file during printing by use of editing software to insert "1" in first column of data line that starts new page. Written in FORTRAN 77.

Akian, Richard A.↗

Monitoring of Time-Dependent System Profiles by Multiplex Gas Chromatography with Maximum Entropy Demodulation

The maximum entropy technique was successfully applied to the deconvolution of overlapped chromatographic peaks. An algorithm was written in which the chromatogram was represented as a vector of sample concentrations multiplied by a peak shape matrix. Simulation results demonstrated that there is a trade off between the detector noise and peak resolution in the sense that an increase of the noise level reduced the peak separation that could be recovered by the maximum entropy method. Real data originated from a sample storage column was also deconvoluted using maximum entropy. Deconvolution is useful in this type of system because the conservation of time dependent profiles depends on the band spreading processes in the chromatographic column, which might smooth out the finer details in the concentration profile. The method was also applied to the deconvolution of previously interpretted Pioneer Venus chromatograms. It was found in this case that the correct choice of peak shape function was critical to the sensitivity of maximum entropy in the reconstruction of these chromatograms.

Becker, Joseph F.↗

Ejecta from Ocean Impacts

Numerical simulations of deep-ocean impact provide some limits on the size of a projectile that will not mix with the ocean floor during a deep-ocean impact. For a vertical impact at asteroidal velocities (approx. 20 km/s), mixing is only likely when the projectile diameter is greater than 112 of the water depth. For oblique impacts, even larger projectiles will not mix with ocean floor silicates. Given the typical water depths of 4 to 5 km in deep-ocean basins, asteroidal projectiles with diameters as large as 2 or 3 km may commonly produce silicate ejecta that is composed only of meteoritic materials and seawater salts. However, the compressed water column beneath the projectile can still disrupt and shock metamorphose the ocean floor. Therefore, production of a separate, terrestrial ejecta component is not ruled out in the most extreme case. With increasing projectile size (or energy) relative to water depths, there must be a gradation between oceanic impacts and more conventional continental impacts. Given that 60% of the Earth's surface is covered by oceanic lithosphere and 500 m projectiles impact the Earth on 10(exp 5) y timescales, there must be hundreds of oceanic impact deposits in the sediment record awaiting discovery.

Kyte, Frank T.↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography

A high-performance liquid chromatographic method was developed as an alternative to automated enzymatic analysis of uric acid in human urine preserved with thymol and/or thimerosal. Uric acid (tR = 10 min) and creatinine (tR = 5 min) were separated and quantified during isocratic elution (0.025 M acetate buffer, pH 4.5) from a mu Bondapak C18 column. The uric-acid peak was identified chemically by incubating urine samples with uricase. The thymol/thimerosal peak appeared at 31 min during the washing step and did not interfere with the analysis. We validated the high-performance liquid chromatographic method for linearity, precision and accuracy, and the results were found to be excellent.

NASA Discipline Regulatory Physiology↗