Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Guidance for Monitoring Passive Groundwater Remedies Over Extended Time Scales

Passive remediation can be appropriate where natural processes and actions such as institutional controls mitigate exposure to contaminated groundwater, achieving remedial action objectives and protectiveness of human health and the environment. Monitored natural attenuation (MNA) is a prevalent passive remediation strategy supported by a regulatory framework and monitoring design guidance. However, long-term passive remedies are usually selected in combination with at least one active remedy, such as source removal, in situ treatment, or pump-and-treat, functioning as a complementary method for achieving remediation objectives and meeting the applicable statutory and regulatory requirements. However, MNA and existing monitoring guidance primarily target situations where the remedial action objectives are met within a few decades. When time scales for passive remediation extend to many decades (50 years or more), a corresponding change in monitoring strategy is needed to adapt to the extended time scale. This document provides guidance for implementing an extended-scale monitoring (ESM) approach appropriate for long-duration passive remediation. Extended-scale is defined in this document with respect to time (i.e., a long duration of remediation) and a large enough physical scale such that downstream receptors will not be impacted within the remediation timeframe. ESM applies to slow-moving groundwater contaminant plumes and emphasizes monitoring primarily for potential exposure pathways. For this approach, the primary monitoring objective is to demonstrate that the plume diminishes before reaching the receptor zone or point of compliance and/or a receptor does not receive concentrations above the compliance limit. While the overall objectives of protecting human health and the environment are the same as for plumes where remediation can occur over a shorter time period, the time scales between decisions are longer and the dynamics of plume evolution are slower. To this end, a scenario-based strategy is described for different plume and source conditions, defining a containment and receptor zones. The containment zone is the area where the risk of exposure to groundwater contamination can be mitigated (e.g., through institutional controls) during the remediation time period. The receptor zone is defined as the area where exposure to groundwater contamination cannot be mitigated and compliance concentration standards must be met. Within the containment zone, slow plume migration may occur, leading to concentrations that exceed compliance standards. However, where distance to the receptor zone is large relative to plume migration and attenuation rate, this approach can be protective of the receptor zone. Selection of a long-duration passive remedy needs to be based on sufficient understanding of contaminant sources, hydrogeology, and contaminant plumes. A strong technical basis, supported by predictive analysis, is recommended to substantiate that contamination is expected to stay within the containment zone during the active remediation and attainment phase of the remedy, and diminish to meet compliance standards within the extended timeframe prior to reaching the receptor zone (e.g., many decades or even centuries). The ESM approach is based on verification of plume behavior and not on detailed plume dynamics. Monitoring is conducted to confirm expected behavior with an emphasis on exposure pathways to verify that plumes remain contained in areas where the protectiveness objectives can be met. ESM should not be adopted if there is significant risk of the plume extending beyond the containment zone. Given the slow movement within the containment zone, less frequent sampling is required relative to approaches used for conventional-scale remediation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Autonomous monitoring of algal biomass: Success stories and lessons learned from long-term field deployment

Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.

Katinas, Christopher Michael [Sandia National Labo↗

Spectroscopic signatures and oxidation characteristics of nanosecond laser-induced cerium plasmas

Improving technologies related to the wide area environmental sampling of nuclear materials supports the nuclear nonproliferation mission of preventing the proliferation of nuclear weapons by monitoring nuclear weapons tests and detecting undeclared nuclear fuel cycle activities. Standoff, laser-based detection techniques such as laser-induced breakdown spectroscopy have the potential to offer robust, field-deployable methods that provide rapid element-specific and phase identifiable measurements over a wide range of materials. This work aims to elucidate the effects of atmospheric conditions and oxidation reactions on the highly complex and transient spectroscopic signatures of laser-induced plutonium surrogate plasmas. Time-resolved spectra of nanosecond laser ablation cerium plasmas were measured using laser-induced breakdown spectroscopy in a range of atmospheres containing low to high concentrations of oxygen. Here, the growth of strong CeO molecular emission bands was observed in the visible spectrum, where it was shown that the persistence of CeO is reduced from around 60 μs to 50 μs in oxygen rich atmospheric environments. To further investigate the growth and depletion of CeO in the laser-produced plasma, ratios of CeO-to-Ce emission were generated using integrated intensities corresponding to the Q-branch of the CeO D 1 -X 1 transitions and numerous strong atomic Ce peaks. It was determined that the fastest rate of formation of CeO in argon occurred for moderate oxygen mass fractions between 0.10 and 0.15 while the ratios were reduced at higher oxygen mass fractions (i.e., Y O 2 = 0.20) due to competing oxidation reactions and lower plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine-Learning Enabled Evaluation of Probability of Piping Degradation In Secondary Systems of Nuclear Power Plants

The transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, technologies used to perform online monitoring of piping and other secondary system structural components in commercial nuclear power plants (NPPs) are under evaluation. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval thus reducing the maintenance cost. This paper describes distributed high-temperature stable fiber sensors fabricated in optical fibers through a roll-to-roll laser direct writing process using femtosecond lasers. Using phase-sensitive optical time domain reflectometry, distributed acoustic and vibration sensors can be developed and deployed to critical components and systems in NPPs to perform active measurements with spatial resolution down to 0.5-meter throughout the piping systems. Complex acoustic and vibration signatures harnessed by distributed sensors are registered and analyzed by artificial intelligence algorithms for degradation detection and flaw identification. Piping elbows with machined-in flaws were instrumented with fiber sensors. High-spatial-resolution data were used to develop and validate machine learning algorithms, including both linear and nonlinear regression, and classification. Additionally, classification and sensor analysis were also performed for data analysis. The paper concludes with recommendations and future work on applications of machine learning enabled high-resolution fiber sensors for piping degradation monitoring in current or future NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Acid Sequestration to Ease Ocean Acidification (EASE-OA) - CRADA 600 (Abstract)

The PNNL team will coordinate logistics involved with setting up the field trial on the PNNL Sequim campus in collaboration with Ebb Carbon. Facilities on the PNNL Sequim campus are capable of pumping raw or filtered seawater from Sequim Bay at a rate ~45,000 L hr -1 , which can accommodate the 4000 L hr -1 requirement of the 200 ton CO2 yr-1 Ebb Carbon marine carbon dioxide removal (mCDR) system. The primary tasks for the PNNL team are 1) laying out appropriate indoor and outdoor spaces for installing the Ebb Carbon’s mCDR system, 2) facilitating Ebb Carbon’s access to the PNNL’s seawater intake on the PNNL Sequim campus, 3) conducting mesocosm experiments within the PNNL Sequim campus laboratories to test how the brine and base discharged from the Ebb Carbon system affect marine life, and 4) facilitating Ebb Carbon access to the PNNL Sequim installation site and aiding in maintenance as needed. In addition to these tasks, the PNNL team will provide surface water quality data (e.g., salinity, temperature, pH, dissolved O2) from a monitoring station located on the pier to contextualize starting conditions of the seawater used in the mCDR process. Finally, the PNNL team will also consult with Ebb Carbon on strategies for improving overall system performance and next steps for further scaling and/or monitoring the effectiveness of the mCDR system.

54 ENVIRONMENTAL SCIENCES↗

Novel gas exposure system for the controlled exposure of plants to gaseous hydrogen fluoride

Abstract Plants can serve as sensitive bioindicators of the presence of contaminant vapors in the atmosphere. This work describes a novel laboratory-based gas exposure system capable of calibrating plants as bioindicators for the detection and delineation of the atmospheric contaminant hydrogen fluoride (HF) as a preparatory step for monitoring release emissions. To evaluate changes in plant phenotype and stress-induced physiological effects attributed to HF alone, the gas exposure chamber must have additional controls to simulate otherwise optimal plant growth conditions including variables such as light intensity, photoperiod, temperature, and irrigation. The exposure system was designed to maintain constant growth conditions during a series of independent experiments that varied between optimal (control) and stressful (HF exposure) conditions. The system was also designed to ensure the safe handling and application of HF. An initial system calibration introduced HF gas into the exposure chamber and monitored HF concentrations by cavity ring-down spectroscopy for a 48-h period. Stable concentrations inside the exposure chamber were observed after approximately 15 h, and losses of HF to the system ranged from 88 to 91%. A model plant species ( Festuca arundinacea ) was then exposed to HF for 48 h. Visual phenotype stress-induced responses aligned with symptoms reported in the literature for fluoride exposure (tip dieback and discoloration along the dieback transition margin). Fluoride concentrations in exposed tissues compared to control tissues confirmed enhanced fluoride uptake due to HF exposure. The system described herein can be applied to other reactive atmospheric pollutants of interest in support of bioindicator research.

54 ENVIRONMENTAL SCIENCES↗

2023 Central Hanford Ecological Integrity Assessments Monitoring Report

The Hanford Site is comprised of an expanse of shrub-steppe habitats that provides exceptional ecological value to plants and animals located on the site and in the surrounding greater Columbia Basin. The U.S. Department of Energy (DOE)-managed portion of the Hanford Site, referred to from here on as Central Hanford, has been the focus of various ecological monitoring efforts, including vegetation monitoring. The scope and goals of vegetation surveys have varied greatly since the Hanford Site was established, but previous studies have documented a rapidly changing landscape, making it clear that continued vegetation monitoring is integral to preserving the ecological value of Central Hanford. A new vegetation monitoring effort was initiated in 2023 using methods based on ecological integrity assessments (EIA) (Natural Heritage Report [NHR] 2020-05) developed by the Washington Natural Heritage Program (WNHP), a division of the Washington State Department of Natural Resources (DNR) and NatureServe®. The methods were modified and supplemented to meet monitoring goals at the Hanford Site. The 2023 EIA monitoring effort consisted of field surveys to evaluate vegetation and soil condition across Central Hanford. Surveys were focused on upland habitats, and areas under consideration for upcoming projects were prioritized. Vegetation cover estimates were used to score a variety of metrics for vegetation conditions in each area. In 2023, approximately half of the site was surveyed. Monitoring methods and results for the 2023 field season are summarized in this report, and management recommendations are also provided.

54 ENVIRONMENTAL SCIENCES↗

Checkpoint triggering in a computer system

According to an aspect, a method for triggering creation of a checkpoint in a computer system includes executing a task in a processing node of the computer system. A monitoring block size is determined for the checkpoint. A checkpoint interval is determined based on the monitoring block size, a checkpoint bandwidth, and a failure rate of the computer system. Based on determining that the checkpoint interval has elapsed, the checkpoint including state data of the task is created to enable restarting execution of the task upon a restart operation. The state data of the checkpoint is restored from a memory responsive to detecting an error condition at the processing node. Execution of the task is restarted in the processing node based on the state data restored from the memory.

97 MATHEMATICS AND COMPUTING↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Application of a Geochemically Informed Leak Detection (GILD) Model to CO 2 Injection Sites on the United States Gulf Coast

The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.

58 GEOSCIENCES↗

Poly(lactic acid)-Based Ink for Biodegradable Printed Electronics With Conductivity Enhanced through Solvent Aging

Biodegradable electronics is a rapidly growing field, and the development of controllably biodegradable, high-conductivity materials suitable for additive manufacturing under ambient conditions remains a challenge. Here, printable conductive pastes that employ poly(lactic acid) (PLA) as a binder and tungsten as a conductor are demonstrated. These composite conductors can provide enhanced stability in applications where moisture may be present, such as environmental monitoring or agriculture. Post-processing the printed traces using a solvent-aging technique increases their conductivity by up to 2 orders of magnitude, with final conductivities approaching 5000 S/m. Such techniques could prove useful when thermal processes including heating or laser sintering are limited by the temperature constraints of typical biodegradable substrates. Finally, both accelerated oxidative and hydrolytic degradation of the printed composite conductors are examined, and a fully biodegradable capacitive soil moisture sensor is fabricated and tested.

36 MATERIALS SCIENCE↗

Influence of Water, Vacuum, and Temperature on Surface Conditions of a Zeolite‐based Molecular Sieve

Molecular sieves such as zeolite-based materials are ubiquitous in industrial separation processes. However, there is a significant gap in understanding the surface properties and adsorption mechanisms for commercial zeolites, as most research focuses on pure zeolite powders rather than industrially relevant forms. Here, this work addresses this gap in understanding by employing advanced characterization techniques, including positron annihilation spectroscopy, X-ray diffraction, scanning electron microscopy, X-ray fluorescence spectroscopy, X-ray photoelectron spectroscopy, liquid nitrogen sorption, and Fourier-transform infrared spectroscopy, to investigate the adsorption and desorption behavior of water in commercial zeolite 13X. Our research reveals insights into the pore-filling mechanisms, the impact of material binders on adsorption properties, and the dynamics of hydration and drying processes for zeolites. Monitoring changes on a minute scale allowed the distinction between fast and slow processes leading to sample drying. The identification of positronium bound to Na + ions indicated that water molecules remain in the vicinity of Na + ions after air-drying zeolite 13X. These findings highlight the importance of various environmental conditions in restoring zeolite properties to baseline after hydration, with significant implications for optimizing industrial processes. This work sets the direction for further research aimed at developing more efficient and robust separation techniques.

Beads Binder↗

Monitoring leaf phenology in moist tropical forests by applying a superpixel-based deep learning method to time-series images of tree canopies

Tropical leaf phenology-particularly its variability at the tree-crown scale-dominates the seasonality of carbon and water fluxes. However, given enormous species diversity, accurate means of monitoring leaf phenology in tropical forests is still lacking. Time series of the Green Chromatic Coordinate (GCC) metric derived from tower-based red-green-blue (RGB) phenocams have been widely used to monitor leaf phenology in temperate forests, but its application in the tropics remains problematic. To improve monitoring of tropical phenology, we explored the use of a deep learning model (i.e. superpixel-based Residual Networks 50, SP-ResNet50) to automatically differentiate leaves from non-leaves in phenocam images and to derive leaf fraction at the tree-crown scale. To evaluate our model, we used a year of data from six phenocams in two contrasting forests in Panama. Here, we first built a comprehensive library of leaf and non-leaf pixels across various acquisition times, exposure conditions and specific phenocams. We then divided this library into training and testing components. We evaluated the model at three levels: 1) superpixel level with a testing set, 2) crown level by comparing the model-derived leaf fractions with those derived using image-specific supervised classification, and 3) temporally using all daily images to assess the diurnal stability of the model-derived leaf fraction. Finally, we compared the model-derived leaf fraction phenology with leaf phenology derived from GCC. Our results show that: 1) the SP-ResNet50 model accurately differentiates leaves from non-leaves (overall accuracy of 93%) and is robust across all three levels of evaluations; 2) the model accurately quantifies leaf fraction phenology across tree-crowns and forest ecosystems; and 3) the combined use of leaf fraction and GCC helps infer the timing of leaf emergence, maturation and senescence, critical information for modeling photosynthetic seasonality of tropical forests. Collectively, this study offers an improved means for automated tropical phenology monitoring using phenocams.

54 ENVIRONMENTAL SCIENCES↗

Assessing Options for Particulate Measurement Tools to Advance Wood Heaters (CRADA Final Report)

For approximately 40 years, particulate matter (PM) from residential wood heaters has been certified in North America using an EPA dilution tunnel with a filter-based gravimetric measurement. While reasonably repeatable, this approach reports only a single value for the entire burn sequence and does not provide information on PM at different points within the sequence, which would support improved wood heater designs. PM monitors that report with high time resolution offer a potential solution, but their performance for various types of heaters and across heater operating conditions has not been extensively evaluated. In this 18-month collaborative project, the Hearth, Patio & Barbecue Association (HPBA) and Lawrence Berkeley National Laboratory (LBNL) tested five continuous PM instruments spanning three measurement principles—light-scattering, inertial mass (TEOM), and triboelectric—against gravimetric and size-resolved references on three residential heater types (cordwood, catalytic cordwood, and pellet) across startup, high-burn, and low-burn operating phases.

42 ENGINEERING↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗