Search NASA⌕ Search

SEARCH · Search NASA

Results for “containment sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Data used in “Enguehard et al. 2022, Machine-Learning Functional Zonation Approach for Characterizing Terrestrial–Aquatic Interfaces: Application to Lake Erie”

The package contains the data layers used in “Enguehard et al. 2022, Machine-Learning Functional Zonation Approach for Characterizing Terrestrial–Aquatic Interfaces: Application to Lake Erie”. Spatial data layers include: topography, wetland vegetation cover, time series of Landsat’s enhanced vegetation index (EVI) between 1990 and 2020. The study aims to characterize coastal wetlands with particular focus on the co-variability between plant dynamics, topography, soil, and other environmental factors. We proposed a functional zonation approach based on machine learning clustering to identify the spatial regions, i.e., zones that capture these co-varied properties. This approach was applied to publicly available datasets along Lake Erie, in the Great Lakes Region

54 ENVIRONMENTAL SCIENCES↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evolution and persistence of SiO emission in nanosecond laser ablation plumes

Analyzing laser-produced plasmas in a controlled oxygen-containing environment provides insight into the formation and evolution of molecular species through gas-phase oxidation. This study explores the role of ambient pressure and oxygen availability in forming SiO molecular species in laser ablation plumes. The self-emission emanating during the reactive ablation of Si targets was characterized by optical emission spectroscopy and optical time-of-flight techniques. Our results showed that the SiO species formation was greatly influenced by both the ambient pressure and oxygen availability. The intensity and the persistence of SiO emission bands are lower at higher oxygen concentrations, indicating they are depopulated by the formation of more complex silicon oxides. The oxygen partial pressure effects on plume chemistry showed that SiO formation is favored even with a minimal oxygen concentration in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Satellite Imagery of PV Site Storm Damage

"This repository contains multiple data sets focused on visible damage to photovoltaic (PV) installations following extreme weather events such as hailstorms and hurricanes. Data sets are split into two categories: the first category, the ‘manually labeled’ data, was compiled by researchers manually, and contains manually identified PV sites exposed to storms. The second data set, the ‘aggregated’ data, is a compilation of the manually labeled PV sites and deep learning-identified PV sites. The hail damage data set focuses on post-storm PV damage following a September 24, 2023 hailstorm in Austin, TX, which caused over $600 million in damages in the Austin metro area. The hurricane damage data set focuses on post-storm PV damage following Hurricanes Irma and Maria in Puerto Rico and the US Virgin Islands. Hurricanes Irma and Maria were back-to-back category 5 hurricanes, which pummeled the Caribbean and southeastern United States in September 2017, causing an estimated $115.2 billion in damages."

14 SOLAR ENERGY↗

Spectro-temporal comparisons of optical emission, absorption, and laser-induced fluorescence for characterizing ns and fs laser-produced plasmas

We performed simultaneous measurement of absorption, emission, and laser-induced fluorescence spectroscopic signatures for determining nanosecond and femtosecond laser-produced plasma’s physical properties throughout its lifecycle. Plasmas are produced by focusing either ~6 ns, 1064 nm pulses from an Nd:YAG or ~35 fs, ~800 nm pulses from a Ti:Sapphire laser on an Inconel target that contains Al as a minor alloying addition. A continuous-wave narrowband tunable laser was used for performing absorption and fluorescence spectroscopy while a fast-gated detection system was used for emission spectroscopy. The temporal evolution of emission, fluorescence, and absorbance of Al transitions are compared for both ns and fs laser-produced plasms. Time-resolved absorbance was also used for evaluating linewidth, lineshape, temperature, and column-averaged atomic number density at late times of ns and fs plasma evolution. Our results demonstrate that lower and excited-state populations of fs laser produced plasmas are short-lived in comparison to those in ns plasmas. The lower state population is observed to reach a maximum value earlier in time for the fs plasma versus the ns plasma, while the kinetic temperature for the ns plasma was higher than for the fs plasma at most times of the plasma evolution.

(280.4788) Optical Sensing, (300.2140) Emission Sp↗

Integrated Harsh Environment Gas / Temperature Wireless Microwave Acoustic Sensor System for Fossil Energy Applications

There is a significant need for sensors capable of detecting gases, such as H 2 , O 2 , NO x , SO x within harsh environments encountered in power plants, industrial manufacturing, oil and gas exploration, and aerospace applications. This project successfully demonstrated the use of wireless microwave acoustic sensor technology for the detection of gases (H 2 or O 2 ) from ambient temperatures up to 650°C. The work focused on langasite (LGS) based surface acoustic wave resonator (SAWR) sensors as the harsh-environment sensor platform and explored multiple combinations of high-temperature thin films and device structures which were used to increase the sensor platform stability and detection capability at temperatures in the operational range of 150°C to 700°C. Specific material configurations that were investigated include: yttria-stabilized-zirconia (YSZ) decorated with Pt nanoparticles, atomic layer deposited (ALD) Al 2 O 3 , palladium, and Pt/Al 2 O 3 co-deposited electrode alloys. Through the deposition of YSZ at temperatures as high as 850°C and the use of graded alloy concentrations of Pt in the fabrication of the Pt/Al 2 O 3 electrode structures, film stress problems were mitigated, and sensor operation and stability achieved. To test and evaluate SAWR sensor performance for the detection of H 2 and O 2 under the influence of temperature variations, a comprehensive gas sensor control system and test apparatus was created to operate within a laboratory box furnace-controlled environment. In addition to the advancement in thin film materials through the deposition and fabrication techniques mentioned above, the work characterized the performance of sensors containing these films in the presence of oxidizing and reducing gases between 25°C and 700°C. In particular, the work revealed that the exposure of the SAWR sensor surfaces to oxidizing environments significantly improve the sensor response to H 2 , whereas the exposure of the sensor to reducing environments at high temperatures (≈ 500°C) renders the sensor irresponsive to H 2 , requiring sensor surface treatment at high temperatures (above 500°C) to recover the responsiveness to H 2 . The SAWR sensors have been also tested for wireless operation and array operation using multiple orientations to resolve the detection of gases under temperature variations. The work developed at the University of Maine was aided by a collaboration with the NETL Research and Innovation Center, Pittsburgh, PA, where thin film materials and device structures fabricated at UMaine were tested and characterized using NETL gas reactors and surface analysis techniques. SAWR sensors fabricated at UMaine were exposed multiple times to temperatures up to 700°C and H 2 concentrations up to 100% in the NETL facilities to measure the sensor performance. Environetix Technologies Corporation, a UMaine harsh-environment sensor spin-off company, also provided support and assistance in sensor system testing and implementation. The sensor small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems and other aerospace or industrial settings that need to be interrogated wirelessly. The SAW platform is an attractive option for high-temperature harsh-environment gas sensing applications due to its inherent features, namely small size, capability of battery-free and wireless operation, and cost effective scale production using well-established production techniques from the semiconductor industry. The research findings achieved in this work, particularly advances regarding the fabrication and performance of the SAWR gas sensor platform, can be adapted and transferred to industrial power plants and other harsh environments.

01 COAL, LIGNITE, AND PEAT↗

High Speed, Localized Multi-Point Strain Measurements on a Containment Vessel at 1.7 MHz Using Swept-Wavelength Laser-Interrogated Fiber Bragg Gratings

Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.

47 OTHER INSTRUMENTATION↗

Early- and late-time dynamics of laser-produced plasmas by combining emission and absorption spectroscopy

Optical emission spectroscopy and laser absorption spectroscopy are two highly complementary techniques for diagnosing plasmas, specifically in the determination of important parameters such as temperature and density. In this work, we characterized a laser-produced plasma by combining emission and tunable absorption spectroscopy. Plasmas are produced by focusing pulses from a frequency quadrupled Nd:YAG laser onto a glass target containing a minor concentration of aluminum in an ambient atmosphere of ~100 Torr N 2 . Here, emission spectroscopy is used to investigate the line behavior of Al and Ca, electron density, and excitation temperature at times = 5 μs, while absorption spectroscopy is used to investigate the line behavior of Al and Ca, species density, and kinetic temperature at times = 5-100 μs. A comparison is made between the excitation temperature measured from emission using the Boltzmann plot method and the kinetic temperature measured from absorption; the implications of this comparison on local thermodynamic equilibrium and line-of-sight averaging are discussed. By combining the two methods of optical emission and laser absorption spectroscopy, a comprehensive characterization of the plasma over the entire lifetime of its evolution is possible, leading to a greater understanding of the plasma behavior including particle condensation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying the Variability of “Fixed-Width” Buffers on Harvested Lands in Western Oregon and Washington

In contemporary forest management, buffers of unharvested trees are left along streams to protect riparian and aquatic ecosystems. Buffer regulations often focus on specific minimum width requirements, which aid in straightforward regulation and application, but minimum widths also suggest buffered edges are uniform and contain little variability. Conceptual papers suggest that alternative buffer configurations may offer greater flexibility in landscape-level protection, increase forest complexity, and enhance aquatic and riparian biodiversity. However, before considering alternatives to fixed-width buffers, it is necessary to quantify the inherent variability in current buffer practices present on the landscape. In this study, we used aerial imagery to quantify variability of buffer widths in two hundred randomly selected recently harvested units on managed land in Oregon and Washington with both fish-bearing and non-fish-bearing sections of stream. Wider buffers on larger streams had a greater magnitude of variability, but when normalized by stream size, variation was greater in smaller streams, and overall, variation ranged from 25% to 50% of the mean width. Despite local variability, buffer widths rarely fell below 9.14 m (30 ft). The variation quantified here provides an initial measure of variability to inform future management, given emerging interest in variable retention buffers.

58 GEOSCIENCES↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Desert Peak Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to the Desert Peak Geothermal Field. It includes all input and output files used in the project. The files include data categories of raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs including Radar, SWIR, Thermal, Geophysics, Geology, and Wells. The files for the Desert Peak Geothermal Site are used with the Geothermal Exploration Artificial Intelligence to identify indicators of blind geothermal systems. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Desert Peak Geothermal Field.

15 GEOTHERMAL ENERGY↗

Remote sensing images, DEM, and point clouds associated with “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds”

This data package is associated with the publication “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds” published in Frontiers in Environmental Science, Environmental Informatics and Remote Sensing (Bao et al., 2026; doi: 10.3389/fenvs.2026.1725258). This data package includes the drone photos for a section of Umtanum Creek in Washington, Unted States. The photos were used to reconstruct the 3-dimensional (3D) digital elevation model (DEM) of the riverbed for the investigated stream section. The reconstruction results from four approaches are provided: (1) unoccupied aerial vehicle (UAV, colloquially known as drone) imagery-based Structure-from-Motion (SfM), (2) a machine learning-based 3D reconstruction model, Visual Geometry Grounded Deep Structure from Motion (VGGSfM), (3) Visual Geometry Grounded Transformer for long sequence of images (VGGT-Long), and (4) handheld smartphone LiDAR scanning. The ground truth measurements by tripod-mounted optical level kit and ground control points GPS locations for evaluating the accuracy of the four reconstruction approaches are also provided in this data package. A preliminary version of this data package was published in October 2025 at the time of manuscript submission. It was updated in March 2026, at the time of manuscript acceptance, to include additional metadata (this readme, data dictionary, and file level metadata). The data did not change. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) 8 folders; (2) the detailed flight configuration html files; (3) field metadata; (4) a readme; (5) a data dictionary; and (6) file-level metadata. The folders “2024_10_18_d01” and “2024_10_18_d02” contain the original drone photos for the two drone flights (d01 and d02) on October 18, 2024. The reconstruction results from each of the approaches are in the folders called “ODM_SfM”, “VGGSfM”, “VGGTLong”, and “LiDAR”. The ground truth measurements are in the folder called “optical_level_kit”. Lastly, results comparing the different approaches are in the folder called “comparisons”. All files are .csv, .html, .jpg, .obj, .txt, and .npy. For information on using the .obj and .npy files, see the readme files within the same folder as the files.

54 ENVIRONMENTAL SCIENCES↗

Sensing and arresting metal corrosion in molten chloride salts at 800 degrees Celsius

Originally this was planned as a 5 task, 3 year project, starting in May 2019. Task 1 Detecting oxidants and metal corrosion in molten chloride salt at 800°C. Task 2 Effectiveness of Zr getter using head gas sensors of inlet and outlet gases. Task 3 Cathodic protection of metal in molten salt at reducing potential. Task 4 Find reduction potential of metals in molten chloride salts & quantum modeling. Task 5 Develop corrosion test sections integrated into molten salt flow loop. After Q4, the project was scaled back and the reorganized SOPO was reduced to 3 tasks to be completed at the end of Q7 on 01/05/2021. The 3 SOPO tasks are: Task 1 Sense oxidants and the metal corrosion in molten Na-K-Mg-Cl salt at 800°C. Task 3 Cathodically protect H230 alloy in molten Na-K-Mg-Cl salt at 800C by making H230 alloy the cathode of a power supply with a chromium-rich-metal as the anode. Task 4 Find the reduction potential of Cr metal in molten Na-K-Mg-Cl salt at 800°C. The total timeline was reduced from 12 to 7 quarters with the end date being, January 5, 2021. This amounted to task 1,3 and 4 being done in Q5,6 and 7 of an extended year 1, ending on January 5, 2021. Task 1, 3 and 4 were completed. For task1) the increase of oxidants in molten salt is detected by two things: i) a positive shift of the electrode potential for a Haynes 230 alloy (H230) metal coupon versus a silver/silver-chloride reference electrode (SSE) and ii) an increase in the corrosion rate of a H230 electrode at 800C. For task 3) applying a cathodic potential (negative overpotential) to a H230 electrode versus SSE arrested the corrosion of the cathodically protected H230 compared to an unprotected “spectator H230 electrode” in the same molten chloride salt. Lastly, for task 4) the reduction potential of chrome and chrome rich, and nickel metal electrodes were measured. The most valuable outcome of this work is that a power supply can arrest metal corrosion for metal in molten chloride salt when the power supply applies a cathodic potential to bare metal, like H230, in molten chloride salts, like ternary Mg-K-Na-chloride salt. H230 is a high strength metal for containing molten chloride salt and ternary Mg-K-Na-chloride salt is used as heat transfer fluids in concentrating solar power plants. When to use cathodic protection for protecting metal in molten chloride salts? Two scenarios are envisioned: 1) for protecting high-valued components, like solar collectors and heat exchangers and 2) for protecting the bare surface in holidays (point defects) of corrosion inhibitors that are to intended to cover the entire surface of metal.

14 SOLAR ENERGY↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Terrestrial laser scanning data (Levels 0 and 1) from Urban Biogeochemistry Pilot Project sites, Knoxville, Tennessee, Jul 2024 - Jul 2025

This data package contains data from terrestrial laser scanning (TLS) at five urban park sites in Knoxville, Tennessee, USA. All parks include open-grown and/or closed-canopy trees and mixed nearby land use. These study sites were established as part of the Urban Biogeochemistry Pilot Project, which has an overall goal of better understanding how hydrobiogeochemical cycling is altered within the human environment. These five sites represent a gradient of urbanization, and were instrumented to understand hydrological and biogeochemical cycling (e.g., soil moisture, soil physical properties and biogeochemistry, tree transpiration, species type). The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree- and stand-level characterization of woody structure and leaf area. TLS scans were placed to capture the area around trees with sap flow sensors, and as much of a 50 m radius area around the meteorological station as possible given site property limits. Derived products will allow upscaling of water content and transpiration data. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Salton Sea Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to Salton Sea Geothermal Field. It includes all input and output files used with the Geothermal Exploration Artificial Intelligence. Input and output files are sorted into three categories: raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs which are titled Radar, SWIR, Thermal, Geophysics, Geology, and Wells. The files are used with the Geothermal Exploration Artificial Intelligence for the Salton Sea Geothermal Site to identify indicators of blind geothermal systems. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Salton Sea Geothermal Site.

15 GEOTHERMAL ENERGY↗

Metaoptics Enabled Multifunctional Imaging

Despite the fact that most microorganisms occupy two- and three-dimensional space in heterogeneous arrangements and in proximity to other microorganisms of different species, much of our current knowledge about their metabolic processes is derived from homogenizing, then analyzing, the chemical content of cultures containing a single microbial species. This project addressed this fundamental dichotomy by developing a set of optical imaging principles combining multiple new technologies. The imaging strategies developed in this project combine metaoptics structures with active in situ nanoscale control of the chemical environment and applied them to a microbial system, Myxococcus xanthus, with particular relevance to the DoE mission. The combination of metaoptical architectures and nanoscale control over the molecular environment enables: (a) precise control over the electromagnetic (EM) field at length scales smaller than the wavelength of light; (b) control of the interaction of the EM field with critical molecular systems in DOE relevant microbes; (c) control over the chemical environment – especially the presence and quantity of reactive oxygen species (ROS) that can affect redox homeostasis; and (d) the ability to ask new kinds of questions not accessible to ‘omics’ approaches or standard methods of biological imaging. These capabilities are applicable to detailed studies of metabolic pathways in microbes and to lignocellulosic biomass deconstruction. To accomplish these objectives, we pursued two over-arching technical goals: (1) the development of new metaoptics-enabled approaches to imaging and spectroscopic characterization; and (2) the development of tools to control the chemical environment of a microbial sample with nanometer-scale precision. Goal 1 was addressed through the design, fabrication, and characterization of new metasurfaces capable of super-resolution imaging through extreme confinement of the optical field. Goal 2 was addressed by controlling the redox potential on the nanoscale in microbial communities and characterizing their effect on intrinsic bacterial fluorophores which act as molecular sentinels and through characterization of soluble factors secreted by Myxococcus xanthus by confocal Raman imaging. The optical imaging/sensing approaches developed here make it possible to use these powerful new imaging and sensing modalities in metabolic studies by making it possible to visualize and track the spatial and temporal expression patterns of natural or engineered pathways in microorganisms.

09 BIOMASS FUELS↗