Search NASA⌕ Search

SEARCH · Search NASA

Results for “control methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Methods for controlling pore morphology in aerogels using electric fields and products thereof

In one embodiment, an aerogel or xerogel includes column structures of a material having minor pores therein and major pores devoid of the material positioned between the column structures, where longitudinal axes of the major pores are substantially parallel to one another. In another embodiment, a method includes heating a sol including aerogel or xerogel precursor materials to cause gelation thereof to form an aerogel or xerogel and exposing the heated sol to an electric field, wherein the electric field causes orientation of a microstructure of the sol during gelation, which is retained by the aerogel or xerogel. In one approach, an aerogel has elongated pores extending between a material arranged in column structures having structural characteristics of being formed from a sol exposed to an electric field that causes orientation of a microstructure of the sol during gelation which is retained by the elongated pores of the aerogel.

36 MATERIALS SCIENCE↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm: Preprint

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighboring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchain↗

Method for Controlling Space Transportation System Life Cycle Costs

A structured, disciplined methodology is required to control major cost-influencing metrics of space transportation systems during design and continuing through the test and operations phases. This paper proposes controlling key space system design metrics that specifically influence life cycle costs. These are inclusive of flight and ground operations, test, and manufacturing and infrastructure. The proposed technique builds on today's configuration and mass properties control techniques and takes on all the characteristics of a classical control system. While the paper does not lay out a complete math model, key elements of the proposed methodology are explored and explained with both historical and contemporary examples. Finally, the paper encourages modular design approaches and technology investments compatible with the proposed method.

McCleskey, Carey M.↗

Secondary Active Rectifier Control Scheme for a Wireless Power Transfer System with Double-Sided LCC Compensation Topology

This paper proposes a secondary control method using an active rectifier for a double-sided LCC tuned wireless power transfer system (WPT) to reduce the communication requirements of the system. As the active rectifier regulates the output power with a constant primary coil current, the secondary circulating time interval is adjusted while maintaining a unity power factor. First, circuit modelling and sensitivity analyses for the voltage gain, input impedance, coil current rating and power transfer are investigated with a design example of 20kW WPT. Subsequently, the control scheme is developed by considering the four operation modes with the phase difference as the control variable. To prove the effectiveness of the proposed control method, a simulation model is built, and the results demonstrate good dynamic performance with high accuracy for voltage regulation. Compared with the conventional secondary control, it improves the performance of the system along with a well-developed converter gain by maintaining the equivalent load resistive and reduced circulating time intervals, which further improves the system efficiency. The proposed system also eliminates the need for an additional de/de converter on the secondary side.

Zou, Shenli↗

Design and implementation of satellite formations and constellations

The direction to develop small low cost spacecraft has led many scientists to recognize the advantage of flying spacecraft in constellations and formations to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, constellations and formation flying impose additional complications on orbit selection and orbit maintenance, especially when each spacecraft has its own orbit or science requirements. The purpose of this paper is to develop an operational control method for maintenance of these missions. Examples will be taken from the Earth Observing-1 (EO-1) spacecraft that is part of the New Millennium Program (NMP) and from proposed Earth System Science Program Office (ESSPO) constellations. Results can be used to determine the appropriateness of constellations and formation flying for a particular case as well as the operational impacts. Applications to the ESSPO and NMP are highly considered in analysis and applications. After constellation and formation analysis is completed, implementation of a maneuver maintenance strategy becomes the driver. Advances in technology and automation by GSFC's Guidance, Navigation, and Control Center allow more of the burden of the orbit selection and maneuver maintenance to be automated and ultimately placed onboard the spacecraft, mitigating most of the associated operational concerns. This paper presents the GSFC closed-loop control method to fly in either constellations or formations through the use of an autonomous closed loop three-axis navigation control and innovative orbit maintenance support. Simulation results using AutoCon(TM) and FreeFlyer(TM) with various fidelity levels of modeling and algorithms are presented.

Folta, David↗

Design and Implementation of Satellite Formations and Constellations

The direction to develop small low cost spacecraft has led many scientists to recognize the advantage of flying spacecraft in constellations and formations to achieve the correlated instrument measurements formerly possible only by flying many instruments on a single large platform. Yet, constellations and formation flying impose additional complications on orbit selection and orbit maintenance, especially when each spacecraft has its own orbit or science requirements. The purpose of this paper is to develop an operational control method for maintenance of these missions. Examples will be taken from the Earth Observing-1 (EO-1) spacecraft that is part of the New Millennium Program (NMP) and from proposed Earth System Science Program Office (ESSPO) constellations. Results can be used to determine the appropriateness of constellations and formation flying for a particular case as well as the operational impacts. Applications to the ESSPO and NMP are highly considered in analysis and applications. After constellation and formation analysis is completed, implementation of a maneuver maintenance strategy becomes the driver. Advances in technology and automation by GSFC's Guidance, Navigation, and Control Center allow more of the burden of the orbit selection and maneuver maintenance to be automated and ultimately placed onboard the spacecraft, mitigating most of the associated operational concerns. This paper presents the GSFC closed-loop control method to fly in either constellations or formations through the use of an autonomous closed loop three-axis navigation control and innovative orbit maintenance support. Simulation results using AutoCon(Trademark) and FreeFlyer(Trademark) with various fidelity levels of modeling and algorithms are presented.

Folta, David↗

System Design Techniques for Reducing the Power Requirements of Advanced life Support Systems

The high power requirement associated with overall operation of regenerative life support systems is a critical Z:p technological challenge. Optimization of individual processors alone will not be sufficient to produce an optimized system. System studies must be used in order to improve the overall efficiency of life support systems. Current research efforts at NASA Ames Research Center are aimed at developing approaches for reducing system power and energy usage in advanced life support systems. System energy integration and energy reuse techniques are being applied to advanced life support, in addition to advanced control methods for efficient distribution of power and thermal resources. An overview of current results of this work will be presented. The development of integrated system designs that reuse waste heat from sources such as crop lighting and solid waste processing systems will reduce overall power and cooling requirements. Using an energy integration technique known as Pinch analysis, system heat exchange designs are being developed that match hot and cold streams according to specific design principles. For various designs, the potential savings for power, heating and cooling are being identified and quantified. The use of state-of-the-art control methods for distribution of resources, such as system cooling water or electrical power, will also reduce overall power and cooling requirements. Control algorithms are being developed which dynamically adjust the use of system resources by the various subsystems and components in order to achieve an overall goal, such as smoothing of power usage and/or heat rejection profiles, while maintaining adequate reserves of food, water, oxygen, and other consumables, and preventing excessive build-up of waste materials. Reductions in the peak loading of the power and thermal systems will lead to lower overall requirements. Computer simulation models are being used to test various control system designs.

Finn, Cory↗

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

Spectroscopic Investigation of Catalyst Inks and Thin Films Toward the Development of Ionomer Quality Control

As the production of polymer electrolyte fuel cells expands, novel quality control methods must be invented or adapted in order to support expected rates of production. Ensuring the quality of deposited catalyst layers is an essential step in the fuel cell manufacturing process, as the efficiency of a fuel cell is reliant on the catalyst layer being uniform at both the target platinum loading and the target ionomer content. Implementing a quality control method that is sensitive to these aspects is imperative, as wasting precious metals and other catalyst materials is expensive, and represents a potential barrier to entry into the field for manufacturers experimenting with novel deposition processes. In this work, we analyzed catalyst inks to determine if their ionomer content could be quantized spectroscopically. Attenuated total reflection (ATR) Fourier transform infrared spectroscopic technique was investigated producing a signal proportional to the ionomer content. ATR spectroscopy was able to quantitatively differentiate samples in which the ionomer to carbon mass ratio (I/C) varied between 0.9 and 3.0. The I/C ratio was correlated to the measured ATR signal near the CF 2 vibrational bands located between 1100 cm −1 and 1400 cm −1 . The experimental results obtained constitute a step toward the development of novel quality control methodologies for catalyst inks utilized by the fuel cell industry.

30 DIRECT ENERGY CONVERSION↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Nonclassical Flight Control for Unhealthy Aircraft

This research set out to investigate flight control of aircraft which has sustained damage in regular flight control effectors, due to jammed control surfaces or complete loss of hydraulic power. It is recognized that in such an extremely difficult situation unconventional measures may need to be taken to regain control and stability of the aircraft. Propulsion controlled aircraft (PCA) concept, initiated at the NASA Dryden Flight Research Center. represents a ground-breaking effort in this direction. In this approach, the engine is used as the only flight control effector in the rare event of complete loss of normal flight control system. Studies and flight testing conducted at NASA Dryden have confirmed the feasibility of the PCA concept. During the course of this research (March 98, 1997 to November 30, 1997), a comparative study has been done using the full nonlinear model of an F-18 aircraft. Linear controllers and nonlinear controllers based on a nonlinear predictive control method have been designed for normal flight control system and propulsion controlled aircraft. For the healthy aircraft with normal flight control, the study shows that an appropriately designed linear controller can perform as well as a nonlinear controller. On the other hand. when the normal flight control is lost and the engine is the only available means of flight control, a nonlinear PCA controller can significantly increase the size of the recoverable region in which the stability of the unstable aircraft can be attained by using only thrust modulation. The findings and controller design methods have been summarized in an invited paper entitled.

Lu, Ping↗

Active Control of High Frequency Combustion Instability in Aircraft Gas-Turbine Engines

Active control of high-frequency (greater than 500 Hz) combustion instability has been demonstrated in the NASA single-nozzle combustor rig at United Technologies Research Center. The combustor rig emulates an actual engine instability and has many of the complexities of a real engine combustor (i.e. actual fuel nozzle and swirler, dilution cooling, etc.) In order to demonstrate control, a high-frequency fuel valve capable of modulating the fuel flow at up to 1kHz was developed. Characterization of the fuel delivery system was accomplished in a custom dynamic flow rig developed for that purpose. Two instability control methods, one model-based and one based on adaptive phase-shifting, were developed and evaluated against reduced order models and a Sectored-1-dimensional model of the combustor rig. Open-loop fuel modulation testing in the rig demonstrated sufficient fuel modulation authority to proceed with closed-loop testing. During closed-loop testing, both control methods were able to identify the instability from the background noise and were shown to reduce the pressure oscillations at the instability frequency by 30%. This is the first known successful demonstration of high-frequency combustion instability suppression in a realistic aero-engine environment. Future plans are to carry these technologies forward to demonstration on an advanced low-emission combustor.

Corrigan, Bob↗

Using Thermally Imperfect and Ideal Gas Equations for Determining Conditions in Slotted Throat Wind Tunnels

The derivation and application of two back pressure controlling methods for setting the dynamic pressure, Mach number, and Reynolds number of subsonic wind tunnels with a slotted-throat test section are discussed. The first method uses a pressure difference to determine the tunnel dynamic pressure via the compressible Bernoulli equations and is used in the ideal gas path in the CFD code. The second method uses an enthalpy difference in the flow to determine the velocity in the test section and can be applied to multispecies, calorically imperfect and calorically perfect gas flow simulations. For a tunnel operating point close to standard atmosphere conditions, Mach number, pressure, and temperature along the tunnel centerline were very closely matched between the various thermodynamic equation assumption controller methods.

Ground Testing↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Tritium Safety: Self-Study Course 11952

Course Overview: Tritium is a radioactive isotope of hydrogen which has characteristics that require workers understand what should be done to work safely and responsibly around it. Tritium is used for defense applications, experimental purposes for general research, and is a byproduct of some of the work that is done at LANL. Practical guidance offered in this training will inform safe handling to minimize negative impacts on personnel, the workspace, and the surrounding environment. This course, Tritium Safety Self-Study (Course 11952), provides information on the physical, chemical, and radioactive properties of tritium; sources of tritium; uses of tritium; biological effects of tritium; radiological control methods for tritium; monitoring methods of tritium; tritium waste minimization and handling; and alarms and proper response to abnormal conditions in a tritium facility. Course Objectives: When you have completed this course, you will be able to: Identify the physical, chemical, and radioactive properties of tritium; Identify the sources of tritium; Identify the uses of tritium; Identify the modes of tritium exposure; Identify the biological effects of tritium; Identify the radiological control methods of tritium; Identify methods used to monitor for tritium; Identify tritium waste minimization and handling techniques; Identify proper response to abnormal conditions in tritium facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent advances in numerical simulation and control of asymmetric flows around slender bodies

The problems of asymmetric flow around slender bodies and its control are formulated using the unsteady, compressible, thin-layer or full Navier-Stokes equations which are solved using an implicit, flux-difference splitting, finite-volume scheme. The problem is numerically simulated for both locally-conical and three-dimensional flows. The numerical applications include studies of the effects of relative incidence, Mach number and Reynolds number on the flow asymmetry. For the control of flow asymmetry, the numerical simulation cover passive and active control methods. For the passive control, the effectiveness of vertical fins placed in the leeward plane of geometric symmetry and side strakes with different orientations is studied. For the active control, the effectiveness of normal and tangential flow injection and surface heating and a combination of these methods is studied.

Kandil, Osama A.↗

System and method of inverter control

A control system and method for an inverter that reduces capacitor current through a DC bus capacitor of the inverter. The control system and method may generate switching signals for a plurality of switching circuits in a manner that reduces capacitor current through the DC bus capacitor.

Xue, Lingxiao↗

Enabling Ultra-Compact, Lightweight, Efficient, and Reliable 6.6 kW On-Board Bi-Directional Electric Vehicle Charger with Advanced Topology and Control

The research explored new topologies, control methods, mechanical integration, and thermal management methods for electric vehicle (EV) on-board chargers. The team investigated capacitor-based power conversion, leveraging the high energy densities inherent to capacitive energy storage compared to inductive methods. The proposed topologies simultaneously enabled high power density and high efficiency of the design. The proposed architecture was demonstrated in a 6.6 kW bi-directional charger prototype. The research pursued several directions to improve system performance. Innovative topologies were studied for both the main power conversion stage as well as the single-phase twice-line-frequency energy buffer. To ensure robust and efficient operation, new control methods were developed to integrate these two subsystems. To achieve high power density in the full system solution, the mechanical structure of the charger is highly optimized to maximally fill the converter box volume. In parallel with the mechanical design effort, the converter was packaged with high-performance cooling methods which removed heat from key areas of power dissipation in the converter. The thermal management system was optimized to minimize its weight and volume, ultimately motivating the design of a custom additively manufactured cold-plate. The full system achieves a peak power of 7 kW with less than 0.3% total harmonic distortion (THD) and greater than 0.994 power factor in power factor correction (PFC) operation, corresponding to a total box-volume power density of 47.9 kW/L and gravimetric power density of 24.6 W/g. The system achieves a peak efficiency of 98.9%, with 97.9% efficiency at maximum power.

33 ADVANCED PROPULSION SYSTEMS↗