Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Model predictive control of KSTAR equilibrium parameters enabled by TRANSP

Due to the complex behavior of tokamak plasmas and the importance of optimizing performance while avoiding instabilities and machine limits, plasma control algorithms are becoming increasingly dependent on sophisticated model-based control approaches. It is anticipated that the use of integrated modeling codes in the model-based control design process will reduce the amount of experimental time needed to implement new control algorithms by facilitating development of control-oriented models and enabling higher-fidelity closed-loop simulations. In this work, a reduced model is developed from a series of TRANSP simulations and is used to develop a model predictive control (MPC) algorithm for controlling important equilibrium parameters in KSTAR [1] discharges. The control algorithm uses the KSTAR neutral beam injection system and the target plasma current and plasma boundary as actuators, and optimizes the plasma stored energy, loop voltage, and internal inductance while avoiding constraints that could lead to disruptions. Higher fidelity testing of the control algorithm is performed using a flexible framework for enabling external processes to actively control plasma parameters in TRANSP simulations. Furthermore, closed-loop simulations demonstrate the ability of the control algorithm to respond to disturbances in density and confinement, handle actuator failures, and move the discharge to high non-inductive fraction conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inverter Controls for Smooth Transition Operation of Networked Microgrids

Islanding sections of a distribution grid as microgrids and networking these microgrids offer promising opportunities for improving system reliability; however, this approach may need distributed energy resources (DERs) to switch between grid-connected and islanded operation without affecting the system stability. The Thevenin impedance of the power system at the DER point of common coupling changes due to networking actions. It is critical to have smooth transitions between modes to ensure stable system operation and to avoid nuisance tripping. This paper presents the design of a grid-forming (GFM)-capable inverter control scheme to reliably operate in distribution systems with networked microgrids. Control mechanisms for smooth transitions between grid-following (GFL) and GFM inverter modes are presented. First, we test the control mechanism on a simple two-source power system through electromagnetic transient (EMT) simulations using a digital real-time simulator. Then, we add multiple such DERs to the EMT model of a real-world distribution feeder and demonstrate stable operation between mode transitions during the networking of the microgrids.

grid forming controls↗

Incorporating energy storage and user experience in isolated microgrid dispatch using a multi-objective model

In order to coordinate multiple different scheduling objectives from the perspectives of economy, environment, and users, a practical multi-objective dynamic optimal dispatch model incorporating energy storage and user experience is proposed for isolated microgrids. In this model, besides microturbine units, energy storage is employed to provide spinning reserve services for microgirds; and furthermore, from the perspective of demand side management, a consumer satisfaction indicator is developed to measure the quality of user experience. A two-step solution methodology incorporating multi-objective optimisation and decision analysis is put forward to address this model. First, a powerful heuristic optimisation algorithm, called the -dominance based evolutionary algorithm, is used to find a well-distributed set of Pareto-optimal solutions of the problem. Thereby, the best compromise solutions are identified from the entire solutions with the use of decision analysis by integrating fuzzy C-means clustering and grey relation projection. The simulation results on the modified Oak Ridge National Laboratory Distributed Energy Control and Communication lab microgrid test system demonstrate the effectiveness of the proposed approach.

Li, Yang↗

Synchronverter-based Control of Multi-Port Autonomous Reconfigurable Solar Plants (MARS)

Control of integrated photovoltaic (PV) plants with energy storage systems (ESSs) has become an important research and development topic in recent times. In this context, a Multi-port Autonomous Reconfigurable Solar (MARS) plant that integrates PV and ESS to alternating current transmission grid and high-voltage direct current (HVdc) link is studied in this paper. With penetration of power electronic based resources in the grid, the grid’s capability to recover from frequency or voltage disturbances are reduced. Therefore, one of the vital objectives of any new grid integrated power electronic resource is to provide advanced control functions like voltage and frequency support to the grid during disturbances. In this research work, a detailed implementation of a synchronverter-based control algorithm of MARS is presented. The proposed control algorithm and the MARS control architecture are evaluated through simulations on PSCAD/EMTDC simulation platform to showcase the performance in different operating conditions. In addition, they are evaluated in Opal-RT offline simulation models which can also be used to perform control-hardware-in-the-loop (cHIL) tests.

Marthi, Phani Ratna Vanamali↗

Wide-area Demand-side Control for Inter-area Oscillation Mitigation in Power Systems

Inter-area oscillations have severely limited maximum power transfer among different areas in large-scale interconnected power grid. If not quickly damped as soon as possible, they may cause system breakup and even lead to large cascading blackouts. To increase the damping of inter-area oscillations, both power system stabilizer~(PSS) and flexible AC transmission system~(FACTS) controller have been widely considered, which affect the real power flow indirectly. However, the effectiveness of these controllers is restricted to the neighborhood of a prescribed set of operating conditions. In this paper, wide-area demand-side control is developed to directly modulate the real power of end-user loads for oscillation mitigation. The proposed control strategy is implemented in a hierarchical manner. At the device layer, individual end-user loads independently turn ON or OFF in response to the broadcasted signals from the coordinator during the real time. At the supervisory layer, autonomous responses of end-user loads are coordinated to ensure the desired power modulation. The effectiveness of the proposed wide-area demand-side control in improving small-signal stability is illustrated by simulations on a large-scale test system.

Lian, Jianming↗

Development of Mockups and Instrumentation for Spent Fuel Drying Tests

The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupled Aerodynamic and Hydrodynamic Hybrid Simulation of Floating Offshore Wind Turbines

The development and innovation of floating offshore wind energy in the U.S. requires detailed high-fidelity observations and measurements of turbine and platform loading due to wind, waves, and currents. However, full-scale and quasi-full-scale experiments require significant financial and temporal investments for construction, experimental testing, and long-term field campaigns. To support the commercial advancement of the offshore wind energy industry, specialized wind tunnel and wave basin experimental facilities are critical to be able to test FOWT designs at small scale under controlled conditions prior to full-scale deployment. Oregon State University (OSU) is internationally known as a leader in water and energy research, development, and testing. The O.H. Hinsdale Wave Research Laboratory (HWRL) and the Wallace Energy Systems and Renewables Facility (WESRF) at OSU have extensive experience building, modeling, monitoring, controlling, and actuating scaled systems. Experiments on wave-structure interaction have been performed at the HWRL since its establishment in 1972. Studies have included the interaction of waves with coastal structures (breakwaters, seawalls, buildings, cylinders, bridges, fixed foundations of offshore wind turbines, etc.) and with floating structures (e.g., wave energy converters, maneuvering of vessels, etc.). Hinsdale is actively used by marine energy technology developers, both for private testing and OSU-collaborative research projects. However, despite the availability of several large-scale facilities for hydrodynamic testing (at OSU and elsewhere in the U.S.), existing experimental laboratories are generally limited in their ability to accurately generate combined wind and wave conditions. The simulation of both wind and waves in experimental testing is complicated due to a number of constraints, including: [i] incompatible similitude laws governing the wind and waves for scaled experiments, [ii] producing accurate wind over a large enough control volume via fans, and [iii] generating wind that reasonably represents the atmospheric boundary layer in existing wave basins/flumes. Hence, physical test data providing insight into the simultaneous wave- and wind-structure response of floating offshore wind components can be difficult to generate. Given the aforementioned challenges in classic hydrodynamic experiments, the motivation of this project is to establish a real-time hybrid simulation (RTHS) approach that can apply aero- and hydro-dynamic loading by augmenting wave-only experimental facilities with virtual aerodynamic forces through numerical models representing the remaining dynamic forces. RTHS is a physical-numerical approach that partitions a prototype system into physical and numerical sub-assemblies that interact with each other through actuators and sensors in real time. In coupling physical and numerical models, the hybrid simulation approach applied herein is ideal for problems with: (1) structures subjected to different scaling laws, such as floating offshore wind turbines subjected to combined aero/hydro-dynamic loading, (2) structures that are too large or complex to be tested entirely in a laboratory setting, such as deep-water mooring applications, and (3) component testing, where the behavior of a portion of the assembly is uncertain but still interacts with other portions of the structure, such as testing the fatigue life of turbine blades. Few U.S. experimental facilities are able to test simultaneous aero- and hydro-dynamic loading and none can accurately produce aero/hydro-dynamic response on scaled FOWT models due to conflicting similitude laws between the wind (commonly Reynolds) and the waves (commonly Froude). To aid in accelerating the development of the U.S. floating offshore industry, there is a significant need to develop a flexible, modular framework that can expand the capacities of existing wave-only laboratories. The project goal is to demonstrate a hydrodynamic real-time hybrid simulation (hydro-RTHS) framework that couples numerical wind and physical waves acting on a FOWT, thus representing simultaneous aero/hydro-dynamic loading. The FOWT is partitioned into a full-scale numerical sub-assembly associated with the aerodynamics and a model-scale physical sub-assembly associated with the hydrodynamics. The numerical-physical partition associated with hydro-RTHS mitigates scaling constraints by supplying different scaling laws to the physical and numerical sub-assemblies. Herein, length, force, and time are scaled and exchanged between the sub-assemblies using Froude scaling to represent the open-channel flow in the physical sub-assembly. Other similitude laws could also be utilized depending on the problem definition. It is envisioned that the ability to model FOWTs under waves and wind, with mitigation of similitude distortions, would result in reduced development costs (currently, FOWT concept development is performed with full-size pro- totypes at enormous expense and risk) and increase the reliability of the FOWT industry (since extreme wave and wind conditions and contingency events can be tested safely in a controlled environment).

16 TIDAL AND WAVE POWER↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

ORBIT simulations of fast ion power loads on the wall of the Divertor Tokamak Test

Abstract Neutral beam injection in tokamaks produces a population of fast ions, which interact with 3D magnetic fields in a variety of ways, often resulting in energetic particle losses in very short times to the wall. Careful design of neutral beams and active control of error fields helps to keep these losses to a minimum. Nevertheless, past experience in tokamaks in the 1980s and detailed simulations for future machines, such as International Thermonuclear Experimental Reactor, suggest that very localized fast ion losses (‘hot spots’) can be present, even if the overall losses are low. In this paper, we discuss this issue in the Divertor Tokamak Test (DTT) project, and we show that in the standard single-null full-power scenario of the DTT, fast ions produce two hot spots, corresponding approximately to the beam injection and exit toroidal angles: the former being mainly due to prompt losses/passing particles, while the latter is due to trapped ions. However, the maximum power load in these spots is of the order ∼ 63 kW m −2 , below the tolerance of plasma-facing components of the machine.

Physics↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

IEEE SusTech 2025 Presentation

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6\% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

42 - ENGINEERING↗

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗