Dragonfly Rotor Optimization using Machine Learning Applied to an OVERFLOW Generated Airfoil Database

NASA’s 4th New Frontiers Mission is the Titan Dragonfly relocatable lander. This coaxial quadrotor vehicle will be launched on a rocket to Titan in 2028. Following a gravity assisted Earth flyby and an approximate 6-year transit, Dragonfly will enter the Titan atmosphere around 2034 with the goal of exploring Titan’s pre-biotic chemistry and habitability. The multirotor design for this unique application has continually evolved since 2016 with constraints such as Titan’s cryogenic atmosphere at 95 Kelvin (-288 F), gravity 14% that of Earth’s, atmospheric density 440% of standard sea-level air, and the inability to test the entire system together under all these conditions until the first flight on Titan. This paper focuses on rotor design aspects of the Dragonfly lander and introduces a novel framework for multirotor design optimization considering multiple flight conditions. The methodology leverages machine learning methods and is demonstrated in the context of Dragonfly. A new OVERFLOW Machine Learning Airfoil Performance (PALMO) database is first presented. PALMO is then wrapped inside a Bayesian optimization framework and applied to a 4-rotor system (one side of the Dragonfly lander). Training data is generated on each iteration of the optimization using the CAMRAD-II comprehensive analysis software to evaluate successive rotor designs in multiple relevant flight conditions. An optimal design for the 4-rotor system was found with approximately 900 rotor designs analyzed in CAMRAD-II, which required 9 million queries of the PALMO surrogate models. This demonstration case evaluated 10,000,000 potential candidate rotor designs in 5.5 hours on 114 CPU cores using uniform inflow, and in 27.8 hours using the prescribed wake model. This work thus enables mid-fidelity rotor design optimization without requiring access to high-performance computing.

Dragonfly↗

Strong and ductile FeNiCoAl-based high-entropy alloys for cryogenic to elevated temperature multifunctional applications

The highly tunable properties of multi-principal element alloys, commonly known as high-entropy alloys (HEAs), provide a remarkable potential for the development of superior materials for critical structural applications that involve extreme conditions. However, the optimization of the properties of HEAs has been primarily limited to behavior at either low or high temperatures. We report on a non-equiatomic, heterostructured, high-entropy alloy FeNiCoAlTaB which possesses remarkable combinations of mechanical properties across a wide range of temperatures from 77 K to 1073 K. The current metastable alloy presents good ductility and superior engineering tensile strengths of 2.2 GPa, 1.4 GPa, 800 MPa, and 500 MPa at 77 K, 298 K, 873 K, and 1073 K, respectively. This behavior is achieved by a synergic sequence of individual mechanisms that are activated at different temperatures. The alloy even displays pseudoelasticity at 77 K with an applied load up to 2 GPa. This work provides a methodology for tailoring structural heterogeneity and metastability in the design and fabrication of multifunctional HEAs that will outperform known metals and alloys over a wide range of temperatures.

36 MATERIALS SCIENCE↗

Magnetic, Mechanical and Thermal Modeling of Superconducting, Whole-Body, Actively Shielded, 3 T MRI Magnets Wound Using MgB 2 Strands for Liquid Cryogen Free Operation

Here we present magnetic, mechanical and thermal modeling results for a 3 Tesla actively shielded whole body MRI (Magnetic Resonance Imaging) magnet consisting of coils with a square cross section of their windings. The magnet design was a segmented coil type optimized to minimize conductor length while hitting the standard field quality and DSV (Diameter of Spherical Volume) specifications as well as a standard, compact size 3 T system. It had an overall magnet length and conductor length which can lead to conduction cooled designs comparable to NbTi helium bath cooled 3 T MRI magnets. The design had a magnetic field homogeneity better than 10 ppm (part-per-million) within a DSV (Diameter of Spherical Volume) of 48 cm and the total magnet winding length of 1.37 m. A new class of MgB 2 strand especially designed for MRI applications was considered as a possible candidate for winding such magnets. This work represents the first magnetic, mechanical and thermal design for a whole-body 3 T MgB 2 short (1.37 m length) MRI magnet based on the performance parameters of existing MgB 2 wire. 3 Tesla MRI magnet can operate at 20 K at 67% of its critical current.

43 PARTICLE ACCELERATORS↗

High Performance PrFeB Permanent Magnets through Novel Pulse Alignment and Compaction Method for Cryogenic Permanent Magnet Undulators (CPMU)

The Phase I feasibility results of processing PrFeB magnets have shown highly promising magnetic property results with the potential to equal or exceed the best PrFeB properties reported. These findings will be advanced in Phase II through composition tuning, optimization of powder alignment from 95% to > 98%, sintering and heat treat adjustments. The objectives of Phase I were successfully achieved during Phase I work. These were to produce PrFeB magnets and test to establish a baseline process including material chemistry, alloy milling to 3 microns, compaction with domain alignment, and liquid Phase sintering and annealing – under both thermal and vacuum cycles. Success of proper chemistry and processing is determined by the finished magnet density and magnetic performance. A density of 7.45 +/-0.03 g/cm3 has been established as demonstrating full density.

36 MATERIALS SCIENCE↗

Extracellular filaments revealed by affinity capture cryogenic-electron tomography

Cryogenic-electron tomography (cryo-ET) has provided an unprecedented glimpse into the nanoscale architecture of cells by combining cryogenic preservation of biological structures with electron tomography. Micropatterning of extracellular matrix proteins is increasingly used as a method to prepare adherent cell types for cryo-ET as it promotes optimal positioning of cells and subcellular regions of interest for vitrification, cryo-focused ion beam (cryo-FIB) milling, and data acquisition. Here we demonstrate a micropatterning workflow for capturing minimally adherent cell types, human T cells and Jurkat cells, for cryo-FIB and cryo-ET. Our affinity capture system facilitated the nanoscale imaging of Jurkat cells, revealing extracellular filamentous structures. It improved workflow efficiency by consistently producing grids with a sufficient number of well-positioned cells for an entire cryo-FIB session. Affinity capture can be extended to facilitate high-resolution imaging of other adherent and non-adherent cell types with cryo-ET.

Biochemistry↗

Conceptual Structural Design and Analysis of a 20 T Hybrid Cos Dipole for Future Particle Colliders

Here, to reach high collision energy for future high-energy particle colliders, like the Future Circular Collider (FCC) or the Muon Collider, it is required to achieve high field strength of the bending dipoles. Currently, the practical limit for Nb$_{\text{3}}$ Sn technology is around 16 T and, in order to further increase the magnetic field, the superconducting magnet community is considering High Temperature Superconductors (HTS), in particular Bi-2212 and REBCO conductors. However, their relevant higher cost has led the community to consider a hybrid approach where HTS materials are used in the high field region of the coils with so-called insert coils, and Low Temperature Superconductors are involved in the lower field part ($< $ 16 T) with so-called outsert coils. This paper describes the conceptual mechanical design of a 20 T hybrid cos$\theta$ dipole configuration. The high stress levels that the structure is facing due to the high magnetic field are discussed. Moreover, it presents the results of the optimization analysis of the shell-based support structure based on the key-and-bladder technology that provides the azimuthal pre-stress during room temperature assembly and cooldown to cryogenic temperatures. The aim of this work is to present a feasible design that satisfies the stress requirements.

D'Addazio, Marika [Politecnico di Torino (Italy); ↗

Novel concepts for the compression of large volumes of carbon dioxide-phase III

In the effort to reduce the release of CO 2 greenhouse gases to the atmosphere, sequestration of CO 2 from Integrated Gasification Combined Cycle (IGCC) and Oxy-Fuel power plants is being pursued. This approach, however, requires significant compression power to boost the pressure to typical pipeline levels. The penalty can be as high as 8-12% on a typical IGCC plant. The goal of this research is to reduce this penalty through novel compression concepts and integration with existing IGCC processes. The primary objective of the study of novel CO 2 compression concepts is to reliably boost the pressure of CO 2 to pipeline pressures with the minimal amount of energy required. Fundamental thermodynamics were studied to explore pressure rise in both liquid and gaseous states. For gaseous compression, the project investigated novel methods to compress CO 2 while removing the heat of compression internal to the compressor. The highpressure ratio, due to the delivery pressure of the CO 2 for enhanced oil recovery, results in significant heat of compression. Since less energy is required to boost the pressure of a cooler gas stream, both upstream and inter-stage cooling is desirable. While isothermal compression has been utilized in some services, it has not been optimized for the IGCC environment. Phase I of this project determined the optimum compressor configuration and developed technology concepts for internal heat removal. Other compression options using liquefied CO 2 and cryogenic pumping were explored as well. Preliminary analysis indicated up to a 35% reduction in power is possible with the new concepts being considered. In the Phase II program, two experimental test rigs were developed to investigate the two concepts further. A new pump loop facility was constructed to qualify a cryogenic turbopump for use on liquid CO 2 . Also, an internally cooled compressor diaphragm was developed and tested in a closed loop compressor facility using CO 2 . Both test programs successfully demonstrated good performance and mechanical behavior. In Phase III, a pilot compression plant consisting of a multi-stage centrifugal compressor with cooled diaphragm technology has been designed, constructed, and tested. Comparative testing of adiabatic and cooled tests at equivalent inlet conditions shows that the cooled diaphragms reduce power consumption by 3-8% when the compressor is operated as a back-to-back unit and by up to 9% when operated as a straight-though compressor with no intercooler. The power savings, heat exchanger effectiveness, and temperature drops for the cooled diaphragm were all slightly higher than predicted values but showed the same trends.

54 ENVIRONMENTAL SCIENCES↗

Systems-To-Atoms (S2A): enabling hydrogen for climate security

The project addresses a critical gap in hydrogen infrastructure by integrating system-level energy models with atomic-scale material simulations in a unified Systems-to-Atoms (S2A) framework. The motivation stems from the need to develop efficient, cost-effective, and durable hydrogen transport and utilization technologies to support decarbonization of hard-to-electrify sectors such as heavy-duty transportation. Current system models lack awareness of material performance mechanisms, while material-scale models do not account for system-level usage and variability. To bridge this divide, the team developed a co-simulation capability linking techno-economic analyses, reactor/process-flow modeling, and molecular-scale catalysis simulations. Applied to hydrogen delivery in California, the framework enabled comparative evaluations of compressed, cryogenic, and liquid organic hydrogen carrier (LOHC) pathways, highlighting how catalyst operation and unit process efficiency influence overall performance. The results demonstrate that no single material or transport mode is universally optimal; instead, heterogeneous solutions tuned to specific operational contexts deliver better performance. The project delivers a new capability for cross-scale material co-design, advancing hydrogen infrastructure readiness and informing DOE and LLNL missions in climate and energy resilience.

organic↗

Technology development program for the Space Infrared Telescope Facility (SIRTF) science instruments

A coordinated technology program for the Space Infrared Telescope Facility (SIRTF) is described. The program encompasses detector technology, cryogenic mechanisms technology, and an adiabatic demagnetization refrigerator. Discrete detectors, detector arrays, detector readouts, and testing of engineering models under simulated flight environment conditions are considered. Several focal planes will be optimized at a particular wavelength range to make up over 247,000 detector pixels from about 1.8 to 1000 microns.

Ramos, Ruben↗

Understanding the Role of Extrinsic Impurities in Bulk Nb SRF Cavities

High gradient and high quality factor superconducting radiofrequency (SRF) cavities are essential for efficient particle acceleration in next-generation accelerators. This work demonstrates that the superconducting performance of bulk niobium can be enhanced through a controlled introduction of interstitial oxygen and nitrogen. Thermal and chemical surface treatments modify the concentration and distribution of these impurities, enabling systematic tuning of SRF cavity performance. By combining cavity RF measurements with quantitative materials characterizations, we isolate the impact of impurity concentration on BCS surface resistance and identify the mechanisms by which interstitial impurities alter the superconducting properties of niobium. We find that nitrogen is an order of magnitude more effective than oxygen in reducing BCS resistance at 16 MV/m and that the reduction arises from a combination of mean free path optimization and superconducting gap enhancement. Using these insights, we develop a predictive model that estimates cavity performance directly from room temperature sample material studies, reducing the reliance on full-scale cryogenic tests for surface treatment development. We then apply this model to explore co-doping strategies, demonstrating that combining interstitial oxygen and nitrogen achieves a synergistic reduction in BCS resistance. These results establish co-doping as a viable path for the development of surface-engineered niobium for future high quality factor SRF applications.

Hu, Hannah [Chicago U.]↗

Compact drilling and sample system

The Compact Drilling and Sample System (CDSS) was developed to drill into terrestrial, cometary, and asteroid material in a cryogenic, vacuum environment in order to acquire subsurface samples. Although drills were used by the Apollo astronauts some 20 years ago, this drill is a fraction of the mass and power and operates completely autonomously, able to drill, acquire, transport, dock, and release sample containers in science instruments. The CDSS has incorporated into its control system the ability to gather science data about the material being drilled by measuring drilling rate per force applied and torque. This drill will be able to optimize rotation and thrust in order to achieve the highest drilling rate possible in any given sample. The drill can be commanded to drill at a specified force, so that force imparted on the rover or lander is limited. This paper will discuss the cryo dc brush motors, carbide gears, cryogenic lubrication, quick-release interchangeable sampling drill bits, percussion drilling and the control system developed to achieve autonomous, cryogenic, vacuum, lightweight drilling.

Gillis-Smith, Greg R.↗

Instrumentation status of the low-b magnet systems at the Large Hadron Collider (LHC)

The low-{beta} magnet systems are located in the Large Hadron Collider (LHC) insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process allowing proton collisions at luminosity up to 10{sup 34}cm{sup -2}s{sup -1}. Those systems are a contribution of the US-LHC Accelerator project. The systems are mainly composed of the quadrupole magnets (triplets), the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} magnet systems operate in an environment of extreme radiation, high gradient magnetic field and high heat load to the cryogenic system due to the beam dynamic effect. Due to the severe environment, the robustness of the diagnostics is primordial for the operation of the triplets. The hardware commissioning phase of the LHC was completed in February 2010. In the sake of a safer and more user-friendly operation, several consolidations and instrumentation modifications were implemented during this commissioning phase. This paper presents the instrumentation used to optimize the engineering process and operation of the final focusing/defocusing quadrupole magnets for the first years of operation.

43 PARTICLE ACCELERATORS↗

Sensitivity of Proposed Search for Axion-induced Magnetic Field using Optically Pumped Magnetometers

We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014)]. The modification of Maxwell’s equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. Here, we discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10 -7 GeV -1 for an axion mass near 3 × 10 -10 eV, which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10 -1 and 10 -7 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 100 micron detector development program

An effort to optimize gallium-doped germanium photoconductors (Ge:Ga) for use in space for sensitive detection of far infrared radiation in the 100 micron region is described as well as the development of cryogenic apparatus capable of calibrating detectors under low background conditions.

Moore, W. J.↗

A New Aging Treatment for Improving Cryogenic Toughness of the Main Structural Alloy of the Super Lightweight Tank

Marshall Space Flight Center (MSFC) has developed a new technique that can enhance cryogenic fracture toughness and reduce the statistical spread of toughness values in alloy 2195. This aging treatment can control the location and size of strengthening precipitate T1, making improvements possible in cryogenic fracture toughness (CFT) and fracture toughness ratio (FTR). At the start of this program, design of experiments (DOE) ingot No. 10 was used as a baseline for aging process development and optimization. The new aging treatment was found to be very effective, improving CFT by approximately 15 to 20 percent for DOE ingot No. 10. To further evaluate the repeatability and effectiveness of this new treatment, the investigators selected and tested three more lots of alloy 2195, using 1.75-in-thick gauge plates with FTR values ranging from 0.85 to 1.07. The new aging treatment effectively enhanced CFT and FTR values for all three lots. In one instance, the material was considered rejectable because it did not meet the minimum FTR value (1.0) of the super lightweight tank (SLWT). The new aging treatment improved its FTR from 0.85 to 1.01, making this material acceptable for use in the SLWT.

Chen, P. S.↗

Computational Optimization of Room Temperature Usable Capacity for Hydrogen Storage in MFU-4-Type Metal–Organic Frameworks via Pairwise Metal Substitutions

The efficient storage of hydrogen is a critical challenge in the quest for sustainable energy solutions. Current adsorbent-based methods achieve satisfactory storage densities predominantly under cryogenic temperatures and/or high pressures, which imposes problems with cost-efficient and safe implementation of this technology. Materials that can bind hydrogen gas reversibly at ambient temperatures and more moderate pressures could play a pivotal role in enabling hydrogen-powered technologies. In this study, we use reliable computational modeling to investigate two synthetically feasible paths for tuning the enthalpy of H2 binding in MFU-4-type metal–organic frameworks (MOFs), aiming to maximize usable capacity. This study examines MIM4 IICl3(bta)6 (bta– = benzotriazolate) Kuratowski-type clusters as a model for strong binding sites in MFU-4l frameworks. We systematically evaluate the impact of separately tuning the central MII metal ion (which plays a structural role) and the peripheral MI metal ion (which binds the substrate) on the energetics of H2 binding. Our computational study reveals that H2 binding at an MI site mostly follows the trend AgI < CuI < NiI < CoI < AuI while a larger central MII site generally weakens the H2 binding at a MI site. Importantly, we have identified three new combinations of MI and MII to achieve high fractional usable capacities of the total H2 adsorbed under a pressure swing from 5 to 100 bar at room temperature. Additionally, we examine the nature of the binding interaction between the peripheral metal atom and the hydrogen molecule. While charge transfer predominantly induces this interaction, for several atom combinations, a change in the polarization (associated with variations in the ionic radius of the MI binding atom) is another important factor for adjusting the strength of the interaction. We suggest that the proposed compositions of Kuratowski-type clusters are highly desirable synthetic targets for future laboratory study.

Tkachenko, Nikolay V↗

Resonant cryogenic chopper

An account is given of the design features, construction, and performance of a both mechanically and thermally robust, resonant cryogenic chopper operating at 4.2 K. The chopper can occult a 2.54-cm aperture at 4.5 Hz, with approximately 1-mW dissipation. The controllability of the stator and rotor magnetic fields facilitates performance optimization and the determination of any possible interference effects. Attention is given to long-term amplitude stability determinations.

Page, Lyman A.↗

JWST ISIM Primary Structure and Kinematic Mount Configuration

In this presentation we will review the evolution of the ISIM primary structure tube topology and kinematic mount configuration to the current baseline concept. We will also show optimization procedures used and challenges resulting from complex joints under launch loads. Two additional key ISIM structure challenges of meeting thermal distortion and stability requirements and metal-composite bonded joint survivability at cryogenic temperatures are covered in other presentations.

Bartoszyk, Andrew↗