Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Beholder Intrusion Detection System Client

Malicious software is capable of hiding itself on a system using the system's own functionality (i.e. system call hooking, interrupt handling, etc.). Hiding requires the use of resources, enabling Beholder to detect the presence of malicious software from the changes in the timing data of critical system functions. The software installs a client, which continually sends analysis reports to a server. The server does post-processing and determines if infection has occurred on the client.

Ferber, Aaron E↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗

Telemetry Anomaly Detection System using Machine Learning to Streamline Mission Operations

Spacecraft housekeeping telemetry is monitored at flight control centers by the operations engineers using tools that can perform limit checking or simple trend analysis. Recent developments in machine learning techniques for anomaly detection enables the implementation of more sophisticated systems that aim to augment current state-of-theart mission tools to provide valuable decision support for the spacecraft operators, assisting in anomaly detection and potentially saving console time for the engineers. We will show some results of the implementation of an anomaly detection tool for the NASA Mars Science Laboratory mission.

Weber, Romann↗

Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, the quality of the reconstructed source image, and the triangulation method. These algorithms have been tested on a large number of simulated photons over a wide energy range (from 200 keV to 2 MeV) emitted by point-like radioactive sources located at different orientations and source-to-detector distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guidance of an autonomous planetary rover based on a short-range hazard detection system

The guidance of an autonomous planetary roving vehicle using a scanning laser/multidetector terrain sensor for short-range hazard detection has been simulated. The sensor data are used to model the terrain, thereby providing the information required by a path selection algorithm to control the motion of the rover. These simulation studies are providing the basis for developing both the real-time computer control software and the hardware systems for laboratory and field testing of rover.

Yerazunis, S. W.↗

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗

Qualification of the ITER CS Quench Detection System using Numerical Modeling

Abstract The ITER Central Solenoid (CS) magnet needs to be protected against overheating of the conductor in the event of the occurrence of a normal zone (NZ). Due to a large amount of stored energy and slow NZ propagation, the NZ needs to be detected and the switchyard needs to open the breakers within 2 s after detection of the NZ. The CS will be discharged on a dump resistor with a time constant of 7.5 s. During operation of the CS and its interaction with the poloidal field (PF) coils and plasma current, the CS experiences large inductive voltages from multiple sources, including nonlinear signals from eddy currents in the vacuum vessel and plasma current variation, that make the task of detecting the resistive signal even more difficult. This inductive voltage needs to be cancelled by quench detection (QD) hardware (e.g., bridges, converters, filters, processors) and appropriate processing of the QD signals to reliably detect NZ initiation and propagation. Two redundant schemes are proposed as the baseline for the CS QD System: 1) A scheme with Regular Voltage Taps (RVT) from triads of Double Pancakes (DP) supplemented by Central Difference Averaging (CDA) and by digital suppression of the inductive voltage from all active coils (the CS and PF coils). Voltage taps are taken from helium outlets at the CS outer diameter. 2)A scheme with Cowound Voltage Taps (CVT) taken from cowound wires routed from the helium inlet at the CS inner diameter. Summary of results of the numerical modeling of the performance of both baseline CS QD systems is presented in this paper. Index Terms Quench detection, Central Solenoid, ITER

Martovetsky, Nicolai N↗

Sensor integration study for a shallow tunnel detection system.

During the past several years, there has been a growing recognition of the threats posed by the use of shallow tunnels against both international border security and the integrity of critical facilities. This has led to the development and testing of a variety of geophysical and surveillance techniques for the detection of these clandestine tunnels. The challenges of detection of these tunnels arising from the complexity of the near surface environment, the subtlety of the tunnel signatures themselves, and the frequent siting of these tunnels in urban environments with a high level of cultural noise, have time and again shown that any single technique is not robust enough to solve the tunnel detection problem in all cases. The question then arises as to how to best combine the multiple techniques currently available to create an integrated system that results in the best chance of detecting these tunnels in a variety of clutter environments and geologies. This study utilizes Taguchi analysis with simulated sensor detection performance to address this question. The analysis results show that ambient noise has the most effect on detection performance over the effects of tunnel characteristics and geological factors.

58 GEOSCIENCES↗

Uniform apparent contrast noise: A picture of the noise of the visual contrast detection system

A picture which is a sample of random contrast noise is generated. The noise amplitude spectrum in each region of the picture is inversely proportional to spatial frequency contrast sensitivity for that region, assuming the observer fixates the center of the picture and is the appropriate distance from it. In this case, the picture appears to have approximately the same contrast everywhere. To the extent that contrast detection thresholds are determined by visual system noise, this picture can be regarded as a picture of the noise of that system. There is evidence that, at different eccentricities, contrast sensitivity functions differ only by a magnification factor. The picture was generated by filtering a sample of white noise with a filter whose frequency response is inversely proportional to foveal contrast sensitivity. It was then stretched by a space-varying magnification function. The picture summmarizes a noise linear model of detection and discrimination of contrast signals by referring the model noise to the input picture domain.

Ahumada, A. J., Jr.↗

Signal photon flux and background noise in a coupling electromagnetic detecting system for high-frequency gravitational waves

A coupling system among Gaussian-type microwave photon flux, a static magnetic field, and fractal membranes (or other equivalent microwave lenses) can be used to detect high-frequency gravitational waves (HFGWs) in the microwave band. We study the signal photon flux, background photon flux, and the requisite minimal accumulation time of the signal in the coupling system. Unlike the pure inverse Gertsenshtein effect (G effect) caused by the HFGWs in the gigahertz band, the electromagnetic (EM) detecting scheme proposed by China and the U.S. HFGW groups is based on the composite effect of the synchroresonance effect and the inverse G effect. The key parameter in the scheme is the first-order perturbative photon flux (PPF) and not the second-order PPF; the distinguishable signal is the transverse first-order PPF and not the longitudinal PPF; the photon flux focused by the fractal membranes or other equivalent microwave lenses is not only the transverse first-order PPF but the total transverse photon flux, and these photon fluxes have different signal-to-noise ratios at the different receiving surfaces. Theoretical analysis and numerical estimation show that the requisite minimal accumulation time of the signal at the special receiving surfaces and in the background noise fluctuation would be {approx}10{sup 3}-10{sup 5} seconds for the typical laboratory condition and parameters of h{sub rms}{approx}10{sup -26}-10{sup -30}/{radical}(Hz) at 5 GHz with bandwidth {approx}1 Hz. In addition, we review the inverse G effect in the EM detection of the HFGWs, and it is shown that the EM detecting scheme based only on the pure inverse G effect in the laboratory condition would not be useful to detect HFGWs in the microwave band.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A design study of a signal detection system

A system is described which can aid in the search for radio signals from extraterrestrial sources, or in other applications characterized by low signal-to-noise ratios and very high data rates. The system follows a multichannel (16 million bin) spectrum analyzer, and has critical processing, system control, and memory fuctions. The design includes a moderately rich set of algorithms to be used in parallel to detect signals of unknown form. A multi-threshold approach is used to obtain high and low signal sensitivities. Relatively compact and transportable memory systems are specified.

Healy, T. J.↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser system detects tower deflections

Continuously measure and record deflection of facility during testing. Facility deflections are then subtracted from shroud deflections during data reduction on computer. System is based on tracking light beam by using two-axis photo detector and feeding signals into X and Y servo system.

Fabik, R. H.↗

Development of a tape transport bacterial detection system

The feasibility of a tape transport chemiluminescence system for bacterial monitoring of regenerated water was demonstrated using a manually operated laboratory breadboard. The principle of detection is based on measuring the increase in chemiluminescence produced by the catalytic action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are distinguished from nonviable by comparing the signals of incubated and unincubated water samples. Using optimized protocols, sensitivities were obtained with 400 ml suspensions of E. coli and Cl. sporogenes. The sensitivity of the unincubated cycle E. coli (aerobe) was found to be 30 to 35 cells/m1, and that of the Cl. sporogenes (anaerobe) was 1000 to 10,000 cells/m1. The lower sensitivity toward Cl. sporogenes is attributed to several factors, namely the lower cytochrome content, the tendency to sporulate, long lag periods and the lower growth rate of Clostridia in general. The operational procedures used for processing the incubated and unincubated samples involved the following sequence: (1) concentrating the sample by filtration through a membrane filter, (2) washing with Dextrose-Thioglycollate Broth (3) incubating (0 to 4 hrs as required), (4) washing with 4M Urea, and (5) reacting with reagent in front of a photomultiplier tube. The signal output was recorded on a strip chart recorder.

Witz, S.↗

PROSPECTS FOR CHARACTERIZING HOST STARS OF THE PLANETARY SYSTEM DETECTIONS PREDICTED FOR THE KOREAN MICROLENSING TELESCOPE NETWORK

I investigate the possibility of constraining the flux of the lens (i.e., host star) for the types of planetary systems the Korean Microlensing Telescope Network is predicted to find. I examine the potential to obtain lens flux measurements by (1) imaging the lens once it is spatially resolved from the source, (2) measuring the elongation of the point-spread function of the microlensing target (lens+source) when the lens and source are still unresolved, and (3) taking prompt follow-up photometry. In each case I simulate the observing programs for a representative example of current ground-based adaptive optics (AO) facilities (specifically NACO on the Very Large Telescope), future ground-based AO facilities (GMTIFS on the Giant Magellan Telescope, GMT), and future space telescopes (NIRCAM on the James Webb Space Telescope, JWST). Given the predicted distribution of relative lens-source proper motions, I find that the lens flux could be measured to a precision of σ{sub H{sub ℓ}}≤0.1 for ≳60% of planet detections ≥5 yr after each microlensing event for a simulated observing program using GMT, which images resolved lenses. NIRCAM on JWST would be able to carry out equivalently high-precision measurements for ∼28% of events Δt = 10 yr after each event by imaging resolved lenses. I also explore the effects various blend components would have on the mass derived from prompt follow-up photometry, including companions to the lens, companions to the source, and unassociated interloping stars. I find that undetected blend stars would cause catastrophic failures (i.e., >50% fractional uncertainty in the inferred lens mass) for ≲ (16 · f {sub bin})% of planet detections, where f {sub bin} is the binary fraction, with the majority of these failures occurring for host stars with mass ≲0.3 M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗