Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System (Final Paper)

SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hz 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.

43 PARTICLE ACCELERATORS↗

Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System - Oral Presentation [Slides]

SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hz 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.

43 PARTICLE ACCELERATORS↗

Non-parametric PCM to ADM conversion

An all-digital technique to convert pulse code modulated (PCM) signals into adaptive delta modulation (ADM) format is presented. The converter developed is shown to be independent of the statistical parameters of the encoded signal and can be constructed with only standard digital hardware. The structure of the converter is simple enough to be fabricated on a large scale integrated circuit where the advantages of reliability and cost can be optimized. A concise evaluation of this PCM to ADM translation technique is presented and several converters are simulated on a digital computer. A family of performance curves is given which displays the signal-to-noise ratio for sinusoidal test signals subjected to the conversion process, as a function of input signal power for several ratios of ADM rate to Nyquist rate.

Locicero, J. L.↗

Field oriented control of induction motors

Induction motors have always been known for their simple rugged construction, but until lately were not suitable for variable speed or servo drives due to the inherent complexity of the controls. With the advent of field oriented control (FOC), however, the induction motor has become an attractive option for these types of drive systems. An FOC system which utilizes the pulse population modulation method to synthesize the motor drive frequencies is examined. This system allows for a variable voltage to frequency ratio and enables the user to have independent control of both the speed and torque of an induction motor. A second generation of the control boards were developed and tested with the next point of focus being the minimization of the size and complexity of these controls. Many options were considered with the best approach being the use of a digital signal processor (DSP) due to its inherent ability to quickly evaluate control algorithms. The present test results of the system and the status of the optimization process using a DSP are discussed.

Burrows, Linda M.↗

Field oriented control of induction motors

Induction motors have always been known for their simple rugged construction, but until lately were not suitable for variable speed or servo drives due to the inherent complexity of the controls. With the advent of field oriented control (FOC), however, the induction motor has become an attractive option for these types of drive systems. An FOC system which utilizes the pulse population modulation method to synthesize the motor drive frequencies is examined. This system allows for a variable voltage to frequency ratio and enables the user to have independent control of both the speed and torque of an induction motor. A second generation of the control boards were developed and tested with the next point of focus being the minimization of the size and complexity of these controls. Many options were considered with the best approach being the use of a digital signal processor (DSP) due to its inherent ability to quickly evaluate control algorithms. The present test results of the system and the status of the optimization process using a DSP are discussed.

Burrows, Linda M.↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

DIRECT RF SAMPLING BASED LLRF CONTROL SYSTEM FOR C-BAND LINEAR ACCELERATOR

Low Level RF (LLRF) control systems of linear accel- erators (LINACs) are typically implemented with hetero- dyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Fre- quency System-on-Chip (RFSoC) device from AMD Xilinx integrates data converters with maximum RF frequency of 6 GHz. This enables direct RF sampling of C-band LLRF signal typically operated at 5.712 GHz without any analogue mixers, which can significantly simplify the system architec- ture. The data converters sample RF signals in higher order Nyquist zones and then up or down convert digitally by the integrated data path in RFSoC. The closed-loop feedback control firmware implemented in FPGA integrated in RF- SoC can process the base-band signal from the ADC data path and calculate the updated phase and amplitude to be up- mixed by the DAC data path. We have developed a C-band LLRF control RFSoC platform with direct RF sampling, which targets Cool Copper Collider (𝐶3) and other C or S band LINAC research and development projects. In this paper, the architecture of the platform will be described. We have optimized the configuration of the data converter and characterized performance of them with RF pulses. The test results for some of the key performance parameters for the LLRF platform with our custom solid-state amplifier, such as phase and amplitude stability, will be discussed in this paper.

Liu, C↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗

Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.↗

Software-Reconfigurable Processors for Spacecraft

A report presents an overview of an architecture for a software-reconfigurable network data processor for a spacecraft engaged in scientific exploration. When executed on suitable electronic hardware, the software performs the functions of a physical layer (in effect, acts as a software radio in that it performs modulation, demodulation, pulse-shaping, error correction, coding, and decoding), a data-link layer, a network layer, a transport layer, and application-layer processing of scientific data. The software-reconfigurable network processor is undergoing development to enable rapid prototyping and rapid implementation of communication, navigation, and scientific signal-processing functions; to provide a long-lived communication infrastructure; and to provide greatly improved scientific-instrumentation and scientific-data-processing functions by enabling science-driven in-flight reconfiguration of computing resources devoted to these functions. This development is an extension of terrestrial radio and network developments (e.g., in the cellular-telephone industry) implemented in software running on such hardware as field-programmable gate arrays, digital signal processors, traditional digital circuits, and mixed-signal application-specific integrated circuits (ASICs).

Farrington, Allen↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Wavelet Analyses of F/A-18 Aeroelastic and Aeroservoelastic Flight Test Data

Time-frequency signal representations combined with subspace identification methods were used to analyze aeroelastic flight data from the F/A-18 Systems Research Aircraft (SRA) and aeroservoelastic data from the F/A-18 High Alpha Research Vehicle (HARV). The F/A-18 SRA data were produced from a wingtip excitation system that generated linear frequency chirps and logarithmic sweeps. HARV data were acquired from digital Schroeder-phased and sinc pulse excitation signals to actuator commands. Nondilated continuous Morlet wavelets implemented as a filter bank were chosen for the time-frequency analysis to eliminate phase distortion as it occurs with sliding window discrete Fourier transform techniques. Wavelet coefficients were filtered to reduce effects of noise and nonlinear distortions identically in all inputs and outputs. Cleaned reconstructed time domain signals were used to compute improved transfer functions. Time and frequency domain subspace identification methods were applied to enhanced reconstructed time domain data and improved transfer functions, respectively. Time domain subspace performed poorly, even with the enhanced data, compared with frequency domain techniques. A frequency domain subspace method is shown to produce better results with the data processed using the Morlet time-frequency technique.

Martin J Brenner↗

Summary of Research Report Cooperative Agreement

Several areas of work related to commercialization of technology developed at NASA Ames Research Center (ARC) are discussed in this report. The areas are: (1) perform a feasibility study to develop a software commercialization center is at ARC; (2) perform preliminary work for formation of joint development of sensor technology for telemedicine applications; (3) development of a discovery interview process and staff training to assist the commercialization of technology developed at Ames, specifically aimed at working with researchers; (4) develop partners to further develop and commercialize image compression technology developed at AMES; (5) assist efforts to commercialize a software technology which imparts the ability to establish relevance-based retrieval in the handling of large repositories of information; (6) explore the development of cryocooler technology using pulse tube refrigeration; (7) assess interest in commercialization of a new method of measuring skin friction drag on wind tunnel models using liquid crystal material; (8) attempt to incorporate emerging technologies in the infrastructure of natural hazards mitigation; and (9) forming a nonprofit organization, "The Bootstrap Alliance", whose mission is to promote the use of digital technologies for collaborative problem solving. The results of these initiatives are discussed.

Source record↗

Turning Limitations into Opportunities in the Development of the Orion Medical System: Incorporation of mHealth Devices

INTRODUCTION: Selection of medical devices for the Orion medical system is a complex task which is dependent on the current state of terrestrial technology. In this work we review the interplay between NASA requirements, constraints, and opportunities for synergy during the development of the Orion medical system. METHODS: The “plan to treat” list of conditions, and subsequently the medical resource list for the Orion Artemis II lunar flyby mission was completed using semi-quantitative methods. During this process, some medical resources were excluded to comply with mass and volume limits, while other resources applicable to multiple medical requirements were prioritized for inclusion. Choices were also examined considering NASA level of care standards for the Artemis design reference missions. As a means to optimize capabilities in spite of mass and volume constraints, ideas for integration of multiple devices into a single platform were explored, including a ‘hackathon’ challenge which was conducted to generate and evaluate concepts for combining medical devices into a single app-based mobile device (ultrasound, ECG, etc.). RESULTS: The Orion team identified 128 medical conditions that we “plan to treat”, with 139 unique medical resources to address these conditions, including 5 digital diagnostic devices (ECG, otoscope, stethoscope, pulse oximeter, and blood pressure monitor). During selection of these digital devices the team noted that miniaturized medical devices often use mobile device platforms (mHealth), some displaying and transmitting data exclusively via mobile device. Of the 5 initially selected devices, all are capable of mobile connection, one which cannot function without a mobile device (ECG). Furthermore, only one of these devices connects natively to a Windows platform, which is currently the only operating system available on Orion. DISCUSSION: Significant savings in mass and volume as well as training and usability improvements can be achieved by leveraging mHealth technologies. However, the platform presents significant challenges for deployment within the Artemis Program including lack of internet connectivity, incompatible operating systems, and radiation concerns. Each of these drawbacks are surmountable with investment in the supporting vehicle architecture, which may become necessary to support the technology trends seen in commercially available medical devices today. Objective: Learn about the opportunities and challenges of leveraging mHealth devices in the development of medical capabilities for austere environments. Learn about the constraints of the NASA spaceflight environment with regards to digital medical device integration.

Douglas Ebert↗