Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

State-Level Comparison of Processes and Timelines for Distributed Photovoltaic Interconnection in the United States

This report presents results from an analysis of distributed photovoltaic (PV) interconnection and deployment processes in the United States. Using data from more than 30,000 residential (up to 10 kilowatts) and small commercial (10-50 kilowatts) PV systems, installed from 2012 to 2014, we assess the range in project completion timelines nationally (across 87 utilities in 16 states) and in five states with active solar markets (Arizona, California, New Jersey, New York, and Colorado).

14 SOLAR ENERGY↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Distribution Model Creation using Circuit Maps for Applied PV Impact Studies

Photovoltaic (PV) generation is becoming increasingly common on power distribution systems. The output fluctuations of this variable resource necessitate the creation of an accurate model to ensure that any adverse impacts to the distribution system are properly addressed. To reduce model creation time, a method of extracting data from AutoCAD drawings using scripted methods was developed. This paper will present a distribution model creation and validation process, document case studies of evaluating the impact of PV interconnections on utility distribution feeders, and discuss future applications. PV integration was found to be easier on 23 kV circuits compared to 4.16 kV circuits.

integrated circuit modeling↗

Large-Scale PV Integration Study

This research effort evaluates the impact of large-scale photovoltaic (PV) and distributed generation (DG) output on NV Energy’s electric grid system in southern Nevada. It analyzes the ability of NV Energy’s generation to accommodate increasing amounts of utility-scale PV and DG, and the resulting cost of integrating variable renewable resources. The study was jointly funded by the United States Department of Energy and NV Energy, and conducted by a project team comprised of industry experts and research scientists from Navigant Consulting Inc., Sandia National Laboratories, Pacific Northwest National Laboratory and NV Energy.

14 SOLAR ENERGY↗

2015 South Carolina PV Soft Cost and Workforce Development Part 2: Six Month Confirmation of Anticipated Job Growth

In 2015, a program was initiated to carefully track and monitor the growth of the solar industry in SC. Prior to then, little information was available on the costs associated with distributed photovoltaic (PV) installations in the Southeastern US. For this report, data were collected from businesses on the number of hires they had at the end of 2014 and compared with data for 2015 and June 2016. It was found that the percentage of installers within the state who serve the residential sector increased to 82% from 67%. During the same time period, the average size of initiated installations for residential, commercial, and utility scale installations all trended upwards. Where residential installations were typically 5 kW-DC in 2014, they were typically 10 kW-DC by late 2015 and in mid-2016. For commercial installations, the average size grew from 84 kW-DC in 2014 to between 136-236 kW-DC in 2015 and then 188-248 kWDC in mid-2016. An exception was seen in utility scale installations where a 2.3 MW-DC system was common in 2014, the size grew to be 5-15 MW-DC in late 2015. The average size dropped 3.1-4.4 MWDC in mid-June 2016, though individual averages up to 20 MW-DC were reported.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Distributed photovoltaic systems: Utility interface issues and their present status

Major technical issues involving the integration of distributed photovoltaics (PV) into electric utility systems are defined and their impacts are described quantitatively. An extensive literature search, interviews, and analysis yielded information about the work in progress and highlighted problem areas in which additional work and research are needed. The findings from the literature search were used to determine whether satisfactory solutions to the problems exist or whether satisfactory approaches to a solution are underway. It was discovered that very few standards, specifications, or guidelines currently exist that will aid industry in integrating PV into the utility system. Specific areas of concern identified are: (1) protection, (2) stability, (3) system unbalance, (4) voltage regulation and reactive power requirements, (5) harmonics, (6) utility operations, (7) safety, (8) metering, and (9) distribution system planning and design.

Hassan, M.↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Model-Free Probabilistic Forecasting of Nodal Voltages in Distribution Systems

As the penetration of distributed energy resources (DERs) into distribution systems increases, so does the interest in forecasting relevant system variables to help mitigate the associated challenges. One such challenge is the more frequent occurrence of excessive voltages in distribution systems with higher shares of DERs. Accurate and reliable estimates together with forecasts of system states (i.e., nodal voltages) will therefore play a key role in improving the utilization of these variable and uncertain sources while mitigating potential operational risks. Whilst recent literature has explored machine learning (ML) methods for voltage estimation and their extrapolation for a short-time period into the future, few have taken uncertainty quantification into account, and these methods have not yet been translated into operations. This paper discusses the advantages offered by probabilistic voltage forecasts and proposes a non-parametric Bayesian method suitable for forecasting nodal voltages at short-term time horizons while accounting for uncertainties in load and distributed photovoltaic (PV) generation. We demonstrate the value of the proposed Gaussian process (GP) model for a case study using historical forecasts and observation data.

distribution system↗

Advanced Photovoltaic Inverter Functionality using 500 kW Power Hardware-in-Loop Complete System Laboratory Testing: Preprint

With the increasing penetration of distribution connected photovoltaic (PV) systems, more and more PV developers and utilities are interested in easing future PV interconnection concerns by mitigating some of the impacts of PV integration using advanced PV inverter controls and functions. This paper describes the testing of a 500 kW PV inverter using Power Hardware-in-Loop (PHIL) testing techniques. The test setup is described and the results from testing the inverter in advanced functionality modes, not commonly used in currently interconnected PV systems, are presented. PV inverter operation under PHIL evaluation that emulated both the DC PV array connection and the AC distribution level grid connection are shown for constant power factor (PF) and constant reactive power (VAr) control modes. The evaluation of these modes was completed under varying degrees of modeled PV variability.

14 SOLAR ENERGY↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management platform↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data: Preprint

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management↗