Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Influence of Methylammonium Chloride on Wide-Bandgap Halide Perovskites Films for Solar Cells

Wide-bandgap perovskites are of paramount importance as the photoactive layer of the top cell in high-efficiency tandem solar cells. Comparably high Br contents are required to widen the perovskite bandgap. However, the increase in Br content causes heterogeneous halide distribution and photoinstability. Here, in this study, the positive effect of the additive methylammonium chloride (MACl) on the optical and electronic properties of Br-rich perovskite, deposited using N-methyl-2-pyrrolidone (NMP) as co-solvent and the gas quenching method, is investigated. Simultaneous in situ grazing-incidence wide-angle X-ray scattering and photoluminescence spectroscopy are used to track the evolution of the structural and optoelectronic properties of the perovskites with different amounts of Br and MACl during the spin-coating and thermal annealing steps. The formation mechanism is elucidated in the presence of MACl. It is observed that chloride ions inhibit the intermediate phases, favoring the formation of a perovskite phase with higher crystallinity. Nano X-ray fluorescence mapping recognizes Br-richer and poorer nanometric domains, whose average sizes reduce for samples with MACl. In conclusion, it is demonstrated that adding MACl affects the formation of wide-bandgap perovskites via destabilization of the intermediate phases and acts on the homogenization of the halide distribution, leading to improved solar cell performances.

14 SOLAR ENERGY↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

Solar-to-Grid Public Data File for Utility-scale (UPV) and Distributed Photovoltaics (DPV) Generation, Capacity Credit, and Value for 2012-2020

Lawrence Berkeley National Laboratory (Berkeley Lab) estimates hourly project-level generation data for utility-scale solar projects and hourly county-level generation data for residential and non-residential distributed photovoltaic (PV) systems in the seven organized wholesale markets and 10 additional Balancing Areas. To encourage its broader use, Berkeley Lab has made this data file public here at OEDI, covering the years 2012-2020. The public project-level dataset is updated annually with data from the previous calendar year. For more information about the research project, including a technical report, briefing material, visualizations, and additional data, please visit the project homepage linked in this submission.

annual solar value↗

Multijunction solar cells with graded buffer Bragg reflectors

Distributed Bragg reflectors are incorporated into the compositionally graded buffers of metamorphic solar cells, adding functionality to the buffer without adding cost. The reflection aids in collection in subcells that are optically thin due to low diffusion length, high bulk recombination, radiation hardness, partially-absorbing quantum structures, or simply for cost savings. Performance enhancements are demonstrated in GaAs subcells with QWs, which is beneficial when GaAs is not the ideal bandgap.

France, Ryan Matthew↗

Spectral Properties of Globally Distributed ENA Fluxes across Diverse Regions of the Heliosphere

This study analyzes energetic neutral atom (ENA) spectral properties across distinct regions of globally distributed flux (GDF) sky maps, using Interstellar Boundary Explorer data from a full solar cycle, corrected for time dispersion. By time-shifting the data to the heliosheath using GDF source distances from D. B. Reisenfeld et al., we achieve a more accurate representation of heliosheath GDF energy spectra. We quantify ENA spectral characteristics, heliosheath line-of-sight-integrated proton pressure, and heliosheath proton temperature, comparing these to solar wind properties at 1 au and interplanetary scintillation-derived solar wind data. Our findings show that the spectral index is generally anticorrelated with heliosheath proton temperature and pressure, except in the central tail, where a partial positive correlation is observed. The lowest spectral index values occur when high-latitude heliosheath regions are dominated by fast solar wind from polar coronal holes. The south pole exhibits the flattest energy spectra due to plasma heating from both fast solar wind and a late-2014 pressure pulse. The central tail shows shorter variability (5–6 yr) for spectral index and heliosheath proton temperature, while proton pressure follows the 11 yr solar cycle. Most spectral shapes exhibit a “knee” distribution, peaking during solar maximum, with an “ankle” shape observed only at the south pole during solar cycle transitions. Asymmetry in proton pressure in the lobes is driven by the draping effect of the local interstellar magnetic field. This study provides insights into the energetic properties of GDF across the heliosphere, enhancing our understanding of the heliospheric environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Probabilistic Modeling of Climate Change Impacts on Renewable Energy and Storage Requirements for NM's Energy Transition Act (SAND Report)

This report provides a study of the potential impacts of climate change on intermittent renewable energy resources, battery storage, and resource adequacy in Public Service Company of New Mexico’s Integrated Resource Plan for 2020 – 2040. Climate change models and available data were first evaluated to determine uncertainty and potential changes in solar irradiance, temperature, and wind speed in NM in the coming decades. These changes were then implemented in solar and wind energy models to determine impacts on renewable energy resources in NM. Results for the extreme climate-change scenario show that the projected wind power may decrease by ~13% due to projected decreases in wind speed. Projected solar power may decrease by ~4% due to decreases in irradiance and increases in temperature in NM. Uncertainty in these climate-induced changes in wind and solar resources was accommodated in probabilistic models assuming uniform distributions in the annual reductions in solar and wind resources. Uncertainty in battery storage performance was also evaluated based on increased temperature, capacity fade, and degradation in round-trip efficiency. The hourly energy balance was determined throughout the year given uncertainties in the renewable energy resources and energy storage. The loss of load expectation (LOLE) was evaluated for the 2040 No New Combustion portfolio and found to increase from 0 days/year to a median value of ~2 days/year due to potential reductions in renewable energy resources and battery storage performance and capacity. A rank-regression analyses revealed that battery round-trip efficiency was the most significant parameter that impacted LOLE, followed by solar resource, wind resource, and battery fade. An increase in battery storage capacity to ~25,000 – 30,000 MWh from a baseline value of ~14,000 MWh was required to reduce the median value of LOLE to ~0.2 days/year with consideration of potential climate impacts and battery degradation.

54 ENVIRONMENTAL SCIENCES↗

LA100 Equity Strategies. Chapter 8: Equitable Rooftop Solar Access and Benefits

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on analysis of customer-sited rooftop solar and storage as a means to reduce electricity bills for low- and moderate-income (LMI) households, multifamily building residents, and renters, who traditionally lack access to bill savings from rooftop solar. Specifically, NREL modeled customer-sited solar and storage adoption using the Distributed Generation Market Demand (dGen™)1 model through 2035 and developed scenarios to identify programs or policies that could support equitable access to bill savings from rooftop solar or solar-plus-storage. Scenarios tested include a direct-install program for LMI customers, net metering for LMI customers, and equitable distribution of benefits from installing solar between owners and renters of renter-occupied buildings. Research was guided by input from the community engagement process, and equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗