At least 343 records · Page 19

Communication-efficient certificate revocation management for Advanced Metering Infrastructure and IoT Integration

Advanced Metering Infrastructure forms a communication network for the collection of power data from smart meters in Smart Grid. As the communication between smart meters could be secured utilizing public-key cryptography, however, public-key cryptography still has certain challenges in terms of certificate revocation and management particularly related distribution and storage overhead of revoked certificates. To address this challenge, in this work, we propose a novel revocation management approach by utilizing cryptographic accumulators which reduces the space requirements for revocation information significantly and thus enables efficient distribution of such information to all smart meters. We implemented the proposed approach on both ns-3 network simulator and a testbed. We demonstrated its superior performance with respect to traditional methods for revocation management.

97 MATHEMATICS AND COMPUTING↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

Nanoscale Design to Enable the Revolution in Renewable Energy

The creation of a sustainable energy generation, storage, and distribution infrastructure represents a global grand challenge that requires massive transnational investments in the research and development of energy technologies that will provide the amount of energy needed on a sufficient scale and timeframe with minimal impact on the environment and have limited economic and societal disruption during implementation. In this opinion paper, we focus on an important set of solar, thermal, and electrochemical energy conversion, storage, and conservation technologies specifically related to recent and prospective advances in nanoscale science and technology that offer high potential in addressing the energy challenge. We approach this task from a two-fold perspective: analyzing the fundamental physicochemical principles and engineering aspects of these energy technologies and identifying unique opportunities enabled by nanoscale design of materials, processes, and systems in order to improve performance and reduce costs. Our principal goal is to establish a roadmap for research and development activities in nanoscale science and technology that would significantly advance and accelerate the implementation of renewable energy technologies. In all cases we make specific recommendations for research needs in the near-term (2-5 years), mid-term (5-10 years) and long-term (>10 years), as well as projecting a timeline for maturation of each technological solution. We also identify a number of priority themes in basic energy science that cut across the entire spectrum of energy conversion, storage, and conservation technologies. We anticipate that the conclusions and recommendations herein will be of use not only to the technical community, but also to policy makers and the broader public, occasionally with an admitted emphasis on the US perspective.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Distributed Cooperative Control of Wind Farms with On-Site Battery Energy Storage Systems

This chapter studies the output power regulation in wind farms consisting of doubly-fed induction generator wind turbines, one of the most popular generator configurations in modern multi-MW wind industry, equipped with on-site battery energy storage systems. Traditionally, wind farms were operated as standalone units or were equipped with a central, large-scale, energy storage system. In fact, most of the existing control designs for hybrid wind-storage applications are centralized, where the central unit collects the measured data from all wind turbines and storage systems (if they exist) and compares with the load demand to generate the reference power for each wind turbine controller. Those centralized setups or control structures do not fully exploit the flexibility and locality of the on-site energy storage systems in a wind farm. Moreover, the storage functionality is lost if the central storage system is broken down, while in a distributed architecture, a failure only affects individual on-site storage systems and the others will still operate. Therefore, on-site storage systems and distributed control designs need to be developed for wind farms to provide regulation services for the grid. An approach to tackle that challenge will be presented in this chapter.

17 WIND ENERGY↗

A High-Performance Sintered Iron Electrode for Rechargeable Alkaline Batteries to Enable Large-Scale Energy Storage

Iron-based alkaline rechargeable batteries such as iron-air and nickel-iron batteries are particularly attractive for large-scale energy storage because these batteries can be relatively inexpensive, environment- friendly, and also safe. Therefore, our study has focused on achieving the essential electrical performance and cycling properties needed for the widespread use of iron-based alkaline batteries in stationary and distributed energy storage applications.We have demonstrated for the first time, an advanced sintered iron electrode capable of 3500 cycles of repeated charge and discharge at the 1-hour rate and 100% depth of discharge in each cycle, and an average Coulombic efficiency of over 97%. Such a robust and efficient rechargeable iron electrode is also capable of continuous discharge at rates as high as 3C with no noticeable loss in utilization. We have shown that the porosity, pore size and thickness of the sintered electrode can be selected rationally to optimize specific capacity, rate capability and robustness. As a result, these advances in the electrical performance and durability of the iron electrode enables iron-based alkaline batteries to be a viable technology solution for meeting the dire need for large-scale electrical energy storage.

25 ENERGY STORAGE↗

Integrated Smart Distribution RD&D Project Final Technical Report

Title XIII of the Energy Independence and Security Act of 2007 (EISA), tasked OE with accelerating the commercialization, deployment and integration of advanced digital systems that are needed to modernize the nation’s electricity delivery network for enhanced interoperability and cyber security. To support this mandated task, a goal of the SGR&D Program is to develop technology with the ability to dynamically optimize grid operations and resources and incorporate demand response and consumer participation. The majority of historical research and development in the domain of distribution management systems (DMS) had focused on classical, radial and passive networks with one-way power flow from transmission to distribution systems and thus to the end customer. With the focus on customers, a bottom-up approach required a completely new thinking in real-time operations, and automation, of smart distribution systems. Thus, the GE team embarked on a project with a plan of two distinct phases. Work during the first phase concentrated on research and development (R&D) for the first three years. The second phase, lasting approximately two years, accomplished the demonstration of the use cases developed during the first phase, with further sharing and dissemination of the research at industry events. The consolidated technical scope of the project can be summarized into the following six areas: Advanced distribution modeling capability to accurately simulate/model smart grid operations. Accurate representation of the distribution system in real- or near real-time (capture real-time topology). Interoperability with, and seamless communication between, other management systems and databases used by the utility Simulation of distribution systems based on real-time operational planning to analyze the benefits of smart grid assets. Integration of network, market, and renewable resource models for next generation DMS. Management and forecasting of DER (Distributed Generation, Storage, Demand Response).

14 SOLAR ENERGY↗

Fluctuant storage temperature increased the heterogeneous distributions of pH and fermentation products in large round bale silage

Abstract In practical of silage production, variations in the fermentation parameters of silage might be attributable to changes in weather data, especially for ambient temperature. The objective of this study was to investigate how the changed temperature of outside weather condition affects distributions of pH and fermentation products in large round bale silage. The bale silages (1.22 m × 1.25 m ø; density, about 168.9 kg dry matter [DM]/m 3 ) were produced by BR6090 Combi from New Holland Agriculture, wrapped with six layers of stretch film, stored at ambient temperature (2–20°C) and constant temperature (10°C; 15°C; 25°C) for 3, 9, 15, 45 and 90 days. Compared with other silages, silage stored at 25°C had higher ( p < 0.05) lactic acid content, lower ( p < 0.05) pH, butyric acid content and ammonia‐nitrogen (N) ratio of total N. Fluctuant storage temperature limited lactic acid fermentation process with delayed pH decline and continuous butyric production and crude protein (CP) degradation. The differences of pH, lactic acid, propionic acid and ammonia‐N were considerably less evident in the centre of silages stored at different temperatures, and they increased towards the boundaries. The data shows that fluctuant storage temperature had undesirable effect on the fermentation quality of silage, especially for the external part of silo; relatively high and stable storage temperature for initial stage of ensiling process was necessary, but did not promote a positive response to the homogeneous distributions of pH and fermentation products in large round bale silage.

Li, Ping↗

Grid-Scale Energy Storage Demonstration of Ancillary Services Using the UltraBattery Technology

The collaboration described in this document is being done as part of a cooperative research agreement under the Department of Energy’s Smart Grid Demonstration Program. This document represents the Final Technical Performance Report, from July 2012 through April 2015, for the East Penn Manufacturing Smart Grid Program demonstration project. This Smart Grid Demonstration project demonstrates Distributed Energy Storage for Grid Support, in particular the economic and technical viability of a grid-scale, advanced energy storage system using UltraBattery ® technology for frequency regulation ancillary services and demand management services. This project entailed the construction of a dedicated facility on the East Penn campus in Lyon Station, PA that is being used as a working demonstration to provide regulation ancillary services to PJM and demand management services to Metropolitan Edison (Met-Ed).

25 ENERGY STORAGE↗

Data management in NOAA

NOAA has 11 terabytes of digital data stored on 240,000 computer tapes. There are an additional 100 terabytes (TB) of geostationary satellite data stored in digital form on specially configured SONY U-Matic video tapes at the University of Wisconsin. There are over 90,000,000 non-digital form records in manuscript, film, printed, and chart form which are not easily accessible. The three NOAA Data Centers service 6,000 requests per year and publish 5,000 bulletins which are distributed to 40,000 subscribers. Seventeen CD-ROM's have been produced. Thirty thousand computer tapes containing polar satellite data are being copied to 12 inch WORM optical disks for research applications. The present annual data accumulation rate of 10 TB will grow to 30 TB in 1994 and to 100 TB by the year 2000. The present storage and distribution technologies with their attendant support systems will be overwhelmed by these increases if not improved. Increased user sophistication coupled with more precise measurement technologies will demand better quality control mechanisms, especially for those data maintained in an indefinite archive. There is optimism that the future will offer improved media technologies to accommodate the volumes of data. With the advanced technologies, storage and performance monitoring tools will be pivotal to the successful long-term management of data and information.

Callicott, William M.↗

Testing of Novel Application of GOTHIC{sup TM} to Modelling of Hydrogen Distribution in Intermediate Level Waste Storage Facilities - 16499

One of the strategies for treatment of intermediate level waste in the United Kingdom is to retrieve the waste from the legacy storage area, condition in a suitable storage container and then hold on-site in an intermediate level waste store until permanent storage in a geological disposal facility becomes available. During storage, hydrogen may be generated inside the containers at a slow rate by a number of mechanisms. The containers can be equipped with vents that release hydrogen and other gasses into the intermediate level waste store, a building which would be constructed to high standards to minimise ingress of moisture. With the low number of air changes associated with the building design there is the potential for gas to accumulate over time. There is, therefore, a requirement to be able to predict future gas concentrations inside the building over a range of operating conditions to ensure that a safe operating envelope is maintained. The usual approach to this problem is to model the evolution of the hydrogen distribution by use of computational fluid dynamics tools. In a situation where weeks of real time need to be simulated in order to understand the slow build-up of a very small volumetric concentration of hydrogen, the use of computational fluid dynamics is not practicable within the time scales demanded by industry. This paper investigates a new approach to tackling this problem using the thermal hydraulic code GOTHIC{sup TM} (GOTHIC{sup TM} incorporates technology developed for the electric power industry under the sponsorship of EPRI, the Electric Power Research Institute). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Iodine and Silver as Biocides for Potable Water in Human Missions beyond Low Earth Orbit

Chemical biocides play an important role in potable water storage and distribution systems. They provide protection against microbial growth that can negatively impact efficient water transport and crew health. Molecular iodine and ionic silver have been used on the International Space Station for decades. Future orbiting and surface habitats will have potable water systems that will require reliable potable water storage and challenging transport schemes during daily operations with potentially lengthy and repeated periods of non-use. Based on a review of literature, experimental data, and flight data this paper categorizes the advantages and disadvantages of the two heritage biocides on ISS: iodine and silver. The history of biocide practices on ISS is compared to requirements of future human missions beyond low Earth Orbit. The upstream water quality supply and downstream water uses are defined with respect to the two biocides. The methods of injection and removal of the two biocides are compared for a range of downstream water uses including drinking water, hygiene water, technical water, oxygen generation water, and extravehicular activity water. The paper provides mission planners with a technical and engineering assessment of the two biocides and identifies gaps in knowledge and on-orbit experiences.

Dean Muirhead↗

Recent advances in redox flow cell storage systems

Several features which were conceived and incorporated into complete redox systems that greatly enhanced its ability to be kept in proper charge balance, to be capable of internal voltage regulation, and in general be treated as a true multicell electrochemical system rather than an assembly of single cells that were wired together, were discussed. The technology status as it relates to the two application areas of solar photovoltaic/wind and distributed energy storage for electric utility applications was addressed. The cost and life advantages of redox systems were also covered.

Thaller, L. H.↗

Novel Control Strategy for Multiple Run-of-the-River Hydro Power Plants to Provide Grid Ancillary Services

Hydropower plant (HPP) generation comprises a considerable portion of bulk electricity generation and is delivered with a low-carbon footprint. In fact, HPP electricity generation provides the largest share from renewable energy resources, which include wind and solar. Increasing penetration levels of wind and solar lead to a lower inertia on the electric grid, which poses stability challenges. In recent years, breakthroughs in energy storage technologies have demonstrated the economic and technical feasibility of extensive deployments of renewable energy resources on electric grids. If integrated with scalable, multi-time-step energy storage so that the total output can be controlled, multiple run-of-the-river (ROR) HPPs can be deployed. Although the size of a single energy storage system is much smaller than that of a typical reservoir, the ratings of storages and multiple ROR HPPs approximately equal the rating of a large, conventional HPP. This paper proposes cohesively managing multiple sets of energy storage systems distributed in different locations. This paper also describes the challenges associated with ROR HPP system architecture and operation.

13 HYDRO ENERGY↗

Decision support for integrated water-energy planning.

Currently, electrical power generation uses about 140 billion gallons of water per day accounting for over 39% of all freshwater withdrawals thus competing with irrigated agriculture as the leading user of water. Coupled to this water use is the required pumping, conveyance, treatment, storage and distribution of the water which requires on average 3% of all electric power generated. While water and energy use are tightly coupled, planning and management of these fundamental resources are rarely treated in an integrated fashion. Toward this need, a decision support framework has been developed that targets the shared needs of energy and water producers, resource managers, regulators, and decision makers at the federal, state and local levels. The framework integrates analysis and optimization capabilities to identify trade-offs, and 'best' alternatives among a broad list of energy/water options and objectives. The decision support framework is formulated in a modular architecture, facilitating tailored analyses over different geographical regions and scales (e.g., national, state, county, watershed, NERC region). An interactive interface allows direct control of the model and access to real-time results displayed as charts, graphs and maps. Ultimately, this open and interactive modeling framework provides a tool for evaluating competing policy and technical options relevant to the energy-water nexus.

13 HYDRO ENERGY↗

Efficient Public-key Revocation Management for Secure Smart Meter Communications using One-way Cryptographic Accumulators

Advanced Metering Infrastructure (AMI) forms a communication network for the collection of power data from smart meters in Smart Grid. As the communication within an AMI needs to be secure, public-key cryptography can be used to reduce the overhead of key management. However, it still has certain challenges in terms of certificate revocation and management. In particular, distribution and storage of the Certificate Revocation List (CRL), which holds the revoked certificates, is a major challenge due to its overhead. To address this challenge, in this paper, we propose a novel revocation management scheme by utilizing cryptographic accumulators which not only reduces the space requirements for revocation information but also enables convenient distribution of revocation information to all smart meters. We implemented this oneway cryptographic accumulator-based revocation scheme on ns-3 using IEEE 802.11s mesh standard as a model for AMI and demonstrated its superior performance with respect to traditional methods of CRL management through extensive simulations.

42 ENGINEERING↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating Demand Participation in Market Operations

Abstract—Demand response and dynamic pricing programs are emerging in greater numbers as policy makers look for higher efficiencies and new mechanisms to integrate distributed resources into system operations. The behavior of demand-side resources (including distributed generation, storage, and load), their interaction with the power system, and their operating characteristics under different electric market scenarios raise many questions for system operators, market operators, and regulators. Computer simulation provides a powerful tool for investigating these issues. This paper discusses the use of GridLab-D as simulation environment to model the behavior of distributed resources in detail such that resources interact in new market environments while observing the physical constraints of system operation. GridLab-D provides an open source platform for integrating demand-side models with power system models and market operation models. The flexibility of this environment will be discussed as well as some of the findings emerging from having this simulation capability. Index Terms—power simulation, power modeling, po

Chassin, David P.↗

Reliability and Safety Assessment of Urban Air Mobility Concept Vehicles

The following work was commissioned by the National Aeronautics and Space Administration (NASA) to guide industry and future regulation related to urban air mobility (UAM). Prior studies compared the relative safety of NASA concept vehicles, Figure ES1, designed for UAM and provided recommendations for industry research, aircraft architectural improvements, and regulatory updates. After the prior study completed, the European Aviation Safety Agency (EASA) released regulatory guidance in the form of a special condition (SC), SC-VTOL-01, for multirotors with distributed propulsion and flight controls (DPFC). The objective of the current work was to develop DPFC architectures that will comply with SC-VTOL-01. Vehicle designs, DPFC architectures, and stability & control (S&C) models were developed to find limitations and trends to guide industry. To guide this task, NASA developed quad, hex, and an octorotor to better define vehicle attributes and trade space. Aircraft for study included electric, hybrid-electric, and turboshaft powerplants and collective and RPM control schemes. Assessments are in terms of the safety level achieved, and/or aircraft component/features needed to meet SC-VTOL-01. The most challenging criteria being the catastrophic failure rate, ≤10-9 catastrophic failures per flight hour, and that no single failures may result in a catastrophic event. A disciplined process was followed, similar to that in Aerospace Recommended Practice (ARP) 4761. A preliminary system safety assessment (PSSA) leveraged prior work as a basis of creating failure rate budgets for system design teams. System designs were updated and iterated upon, working with reliability and safety subject matter experts to develop SC-VTOL-01 compliant designs. Design changes were reflected in updated PSSAs for initial verification of compliance. The DPFC architecture was broken into four system design teams, the (1) flight control system (FCS), (2) drive and power system, (3) thermal management system (TMS), and (4) electrical power and distribution system. The FCS including elements necessary to control the aircraft, drive and power including elements necessary to generate and transmit shaft power, the TMS including elements necessary to maintain temperature limits in all operating environments, and electrical pow-er and distribution including equipment necessary to store and transmit electrical energy. Results found that all aircraft evaluated may have paths to comply with SC-VTOL-01, Figure ES2. However, S&C models showed large power transients that must be addressed and PSSA results show that future work is needed in single load path structures, high voltage power storage and distribution, and in motor/rotor overspeed protection.

Boeing↗