Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Volatile propellant droplet evaporation measurements in metered dose inhaler sprays

Many aerosol products rely on the rapid vaporization of volatile propellants to produce a fine spray. In the simplest case, these are binary mixtures of propellant and a delivered product which undergo a flash-evaporation process leaving only the less volatile product in the resultant droplet. In more complex applications, such as pressurized metered-dose inhalers, the non-propellant component may contain dissolved or suspended drug which precipitates or dries to form a matured particle. The size and morphology of the particles depend strongly on the time-history of the droplet as the propellant evaporates. However, measuring the dynamic evaporation processes that occur in dense sprays containing millions of droplets is challenging. In this paper, we demonstrate a novel application of Ultra Small Angle X-ray Scattering to measure the bulk composition of volatile HFC134a–ethanol sprays and compare the obtained results with simple evaporation models in a dry nitrogen environment. The data reveal that diffusion-limiting processes inside the droplet are equally important as external convection and mixing-limited factors in determining evaporative timescales.

42 ENGINEERING↗

Towards Mitigating Electron Beam-Induced Damage in MOFs Using Low Dose Electron Microscopy for In-Situ Room-Temperature Measurements

Metal-Organic Frameworks (MOFs) have emerged as a versatile class of materials with applications in gas storage and separation, catalysis, and drug delivery [1]. Understanding their damage mechanisms in under various environmental conditions is crucial for optimizing performance and stability [2]. This study employs a combination of Length Structural Coherence (LSC) analysis in electron scattering and Electron Energy Loss Spectroscopy (EELS) to elucidate the damage mechanisms in two representative MOFs. MIL101(Fe), and MIL101(Cr). Here, the primary objective is to reveal structural and chemical changes that occur under electron beam irradiation in Scanning Transmission Electron Microscopy (STEM), both in the pristine state and during in-situ CO and CO 2 adsorption. By combining LSC in Radial Distribution Function (RDF) analysis with EELS, comprehensive insights into the nanoscale alterations are obtained and correlated to the electron dose rate.

dos Santos, Gabriel T. [Northwestern University, E↗

Evaluating the impact of anatomical and physiological variability on human equivalent doses using PBPK models

Abstract Addressing human anatomical and physiological variability is a crucial component of human health risk assessment of chemicals. Experts have recommended probabilistic chemical risk assessment paradigms in which distributional adjustment factors are used to account for various sources of uncertainty and variability, including variability in the pharmacokinetic behavior of a given substance in different humans. In practice, convenient assumptions about the distribution forms of adjustment factors and human equivalent doses (HEDs) are often used. Parameters such as tissue volumes and blood flows are likewise often assumed to be lognormally or normally distributed without evaluating empirical data for consistency with these forms. In this work, we performed dosimetric extrapolations using physiologically based pharmacokinetic (PBPK) models for dichloromethane (DCM) and chloroform that incorporate uncertainty and variability to determine if the HEDs associated with such extrapolations are approximately lognormal and how they depend on the underlying distribution shapes chosen to represent model parameters. We accounted for uncertainty and variability in PBPK model parameters by randomly drawing their values from a variety of distribution types. We then performed reverse dosimetry to calculate HEDs based on animal points of departure for each set of sampled parameters. Corresponding samples of HEDs were tested to determine the impact of input parameter distributions on their central tendencies, extreme percentiles, and degree of conformance to lognormality. This work demonstrates that the measurable attributes of human variability should be considered more carefully and that generalized assumptions about parameter distribution shapes may lead to inaccurate estimates of extreme percentiles of HEDs.

Toxicology↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Revealing the electronic structure of van der Waals antiferromagnetic NiPS 3 through synchrotron-based 𝜇-ARPES and alkali metal dosing

Antiferromagnetic NiPS 3 has recently emerged as a quantum material of considerable interest, thanks to the discovery of multiple new couplings involving electrons, spins, orbitals, phonons, and magnons. However, controversies and open questions persist concerning the fundamental origins of these couplings. A critical piece of information required to advance the understanding is the precise electronic band structure of NiPS 3 . Angle-resolved photoemission spectroscopy (ARPES), combined with alkali metal dosing (AMD), can enable us to directly observe the subtle electronic states that appear around the Fermi surface, offering valuable insights into the intriguing quantum properties and interplays of the examined material. Here, in this study, we present a comprehensive characterization and analysis of the band structure of van der Waals layered antiferromagnet NiPS 3 , leveraging state-of-the-art μ-ARPES measurements supported by density functional theory (DFT) calculations. Theoretical DFT results identify the orbital contributions to the observed bands, providing a precise understanding of the experimental ARPES data. Crucially, AMD enables the observation of conduction band and defect-related states above the valence band maximum in NiPS 3 . Furthermore, temperature dependent ARPES results across the Néel transition temperature of NiPS 3 reveal that the paramagnetic and antiferromagnetic phases have nearly identical band structures, underlining the highly localized character of Ni d states. These findings substantially deepen our understanding of the electronic properties of NiPS 3 and lay a vital foundation for exploring the intriguing quantum phenomena it exhibits.

Cao, Yifeng [Boston Univ., MA (United States); Law↗

Single-dose mucosal replicon-particle vaccine protects against lethal Nipah virus infection up to 3 days after vaccination

Nipah virus (NiV) causes a highly lethal disease in humans who present with acute respiratory or neurological signs. No vaccines against NiV have been approved to date. Here, we report on the clinical impact of a novel NiV-derived nonspreading replicon particle lacking the fusion (F) protein gene (NiVΔF) as a vaccine in three small animal models of disease. A broad antibody response was detected that included immunoglobulin G (IgG) and IgA subtypes with demonstrable Fc-mediated effector function targeting multiple viral antigens. Single-dose intranasal vaccination up to 3 days before challenge prevented clinical signs and reduced virus levels in hamsters and immunocompromised mice; decreases were seen in tissues and mucosal secretions, critically decreasing potential for virus transmission. This virus replicon particle system provides a vital tool to the field and demonstrates utility as a highly efficacious and safe vaccine candidate that can be administered parenterally or mucosally to protect against lethal Nipah disease.

60 APPLIED LIFE SCIENCES↗

Modeling Cell Survival Fraction and Other Dose-Response Relationships for Immunodeficient C.B-17 SCID Mice Exposed to 320-kV X Rays

US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.

Scott, Bobby R.↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

The Oak Ridge National Laboratory (ORNL) Second Target Station (STS) neutron production facility is an accelerator driven pulsed neutron source that is currently being actively developed at ORNL. The neutrons are produced by proton-induced spallation reactions. A proton beam of 700 kW power is delivered to a spallation target in short, less than 1 µs long pulses, with 15 Hz repetition rate. The spallation target of ORNL STS is a rotating water-cooled tungsten target with tantalum cladding housed in a stainless-steel shroud. It is divided into 21 segments. These segments become highly activated due to spallation reactions or nuclei transmutation by the emitted neutrons. The radioactive nuclides continue to decay after ceasing operation. The decay dose rates generated from the target segments once they are removed from their operational location within the core vessel must be accurately quantified to determine the shielding configurations of remote handling tools and transport casks and to aid in planning maintenance events. To determine the shielding configurations needed for an activated target segment after ceasing operation, both the hybrid unstructured mesh (UM)/constructive solid geometry (CSG) approach that was previously utilized for STS analyses [1] and the ADVANTG code [2] were used. Even though the ADVANTG code does not include UM capability, the utilization of its advanced variance reduction technique was crucial to accelerate the extremely difficult final photon transport calculation in this analysis. This paper also describes the procedures taken to mitigate the convergence issues that occur when ADVANTG uses a source definition that does not match the source of the final Monte Carlo (MC) calculation. These convergence issues often occur because of inconsistencies between source and transport biasing parameters.

Ibrahim, Ahmad↗

Ketone monoester plus high‐dose glucose supplementation before exercise does not affect immediate post‐exercise erythropoietin concentrations versus glucose alone

Abstract The objective of this study was to examine the effect of consuming ketone monoester plus a high dose of carbohydrate from glucose (KE + CHO) on the change in erythropoietin (EPO) concentrations during load carriage exercise compared with carbohydrate (CHO) alone. Using a randomized, crossover design, 12 males consumed KE + CHO (573 mg KE/kg body mass, 110 g glucose) or CHO (110 g glucose) 30 min before 4 miles of self‐paced treadmill exercise (KE + CHO:51 ± 13%, CHO: 52 ± 12% V̇O 2peak ) wearing a weighted vest (30% body mass; 25 ± 3 kg). Blood samples for analysis were obtained under resting fasted conditions before (Baseline) consuming the KE + CHO or CHO supplement and immediately after exercise (Post). βHB increased ( p < 0.05) from Baseline to Post in KE + CHO, with no change in CHO. Glucose and glycerol increased ( p < 0.05) from Baseline to Post in CHO, with no effect of time in KE + CHO. Insulin and lactate increased ( p < 0.05) from Baseline to Post independent of treatment. EPO increased ( p < 0.05) from Baseline to Post in KE + CHO and CHO with no difference between treatments. Although KE + CHO altered βHB, glucose, and glycerol concentrations, results from this study suggest that KE + CHO supplementation before load carriage exercise does not enhance immediate post‐exercise increases in EPO compared with CHO alone.

Howard, Emily E.↗

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

Hotspot 2.07.1 doses (FGR-13) from releases of 1 g Pu-239 (SBK Calcs)

This calculation is to be used for accident analysis at B239, B331, B332, and B334. The objective of this analysis is to determine: The dose per gram of Pu-239 Solubility Class S (FGR-13) for various release heights, receptor heights and distances from 100 to 1000 meters. This calculation can be used to evaluate particulate plume dispersion releases for the co-located worker and public receptors.

61 RADIATION PROTECTION AND DOSIMETRY↗

95th percentile doses to public and co-located workers based on five years (2010-2014) of LLNL meteorological data (WSF B625)

This calculation is to be used for accident analysis at the Waste Storage Facilities (WSF). The objective of this analysis is to determine: The 95th percentile dose to the public and co-located workers used for accident analysis consistent with NRC Regulatory Guide 1.145 Position 3 using MACCS2 and five years (2010-2014) of LLNL meteorological data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Default Radioactive and Hazardous Waste Management (RHWM) Dose Conversion Factors (DCFs) and Weighting Factors and plutonium-239 equivalent Curie (PE-Ci) methodology for acceptance into the Waste Storage Facilities

DOE-STD-5506-2007 (Ref. 1) is the standard that provides the methodology for preparing hazard analysis and accident analysis for transuranic (TRU) waste facilities. The Waste Storage Facilities hazard and accident analysis for the DSA is developed in accordance with DOE-STD- 5506-2007. Two related issues need to be addressed when implementing DOE-STD-5506-2007 regarding the calculation of consequences from TRU waste releases in accident analysis: Consequences determined in accident analysis must be modeled using inhalation Dose Conversion Factors (DCFs) that are consistent with those from the International Commission on Radiological Protection Publication 72 (ICRP-72, Ref. 2).; The use of a statistical Material at Risk (MAR) representing the distribution of radiological loading of TRU waste containers based on the use of a plutonium-239 equivalent Curie (PE-Ci) methodology. The PE-Ci methodology simplifies accident analysis by allowing one to model releases based on the Curie value of one standard nuclide (e.g., Pu-239) instead of needing to model releases for every potential nuclide of interest. This is accomplished by normalizing the Curie value of all nuclides to a single Curie value of a standard nuclide by using a Weighting Factor that is a ratio of the DCFs associated with the nuclides and that of the standard nuclide. By using the ICRP-72 DCFs to calculate PE-Ci values used in the statistical MAR, the accident analysis that uses that statistical MAR will be consistent with the consequence methodology identified in DOE-STD- 5506-2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Null-Space Model Carlo Flow Model Set

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations as a part an uncertainty analysis for the updated Hanford Site Composite Analysis (CA). The Plateau-to River (P2R) Groundwater Model (CP-57037, Model Package Report: Plateau to River Groundwater Model Version 8.3) is the CA base case that simulates the fate and transport of radiological contaminants within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. An NSMC analysis was performed to identify and quantify the potential uncertainties associated with the P2R Model. The result of the NSMC analysis is a set of flow and transport simulations that provide an estimated range of possible outcomes that are used to quantify the uncertainty associated with the simulated base case concentrations.

54 ENVIRONMENTAL SCIENCES↗

On the Determination of the Radiation Doses at Hiroshima [Slides]

Essentially all knowledge regarding the chronic effects of radiation exposure is derived from statistical analyses of the survivors of Hiroshima and Nagasaki. However, we were then, and are now, uncertain about the exposures. That is: We know the effects through observations and statistical analyses, but we can only estimate the doses. Other complications include the fact that Little Boy was truly unique. It was never tested, measurements of yield were ambiguous, calculations of yield were not consistent, and calibration measurements were not made, could not be made.

61 RADIATION PROTECTION AND DOSIMETRY↗

Expected Dose Rates from 1 MeV Electron Accelerator

The purpose of this study was to simulate UCLA’s 1 MeV electron accelerator and calculate the expected dose rates at various locations inside of the lab and outside of the building to see if they fall into safe levels.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Tritium Dose Calculations from MACCS, UFOTRI, and ETMOD

Tritium exhibits unique environmental behavior because of its potential interactions with water and organic substances. Modeling the environmental consequences of tritium releases can be relatively complex and thus an evaluation of MACCS is needed to understand what updates, if any, are needed in MACCS to account for the behavior of tritium. We examine documented tritium releases and previous benchmarking assessments to perform a model intercomparison between MACCS and state-of-practice tritium-specific codes UFOTRI and ETMOD to quantify the difference between MACCS and state of practice models for assessing tritium consequences. Additionally, information to assist an analyst in judging whether a postulated tritium release is likely to lead to significant doses is provided.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗