Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric utility programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Phased Retrofits in Existing Homes In Florida Phase I: Shallow and Deep Retrofits

The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and single measures are summarized in this report. Project results will be of interest to utility program designers, weatherization evaluators, and the housing remodel industry. Shallow retrofits were conducted in all homes from March to June 2013. The measures for this phase were chosen based on ease of installation, targeting lighting (CFLs and LED lamps), domestic hot water (wraps and showerheads), refrigeration (cleaning of coils), pool pump (reduction of operating hours), and the home entertainment center (smart plugs). Deep retrofits were conducted on a subset of ten PDR homes from May 2013 through March 2014. Measures included new air source heat pumps, duct repair, ceiling insulation, heat pump water heaters, variable speed pool pumps and learning thermostats. Major appliances such as refrigerators and dishwashers were replaced where they were old and inefficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

INTERFUEL: FAST -- Fueling Center and EVSE Reporting Process Changes

This presentation presents an overview of coming changes to how federal agencies with motor vehicles will submit required information about fueling centers and electric vehicle supply equipment (EVSE) inventory through the Federal Automotive Statistical Tool (FAST). Historically, information covering these two areas has been provide during two separate data submissions, but is now being consolidated and simplified into a single submission due by December 15 of each year. The presentation provides background on the process, a re-cap of how the information is currently submitted, and describes the new approach for organizations to submit the required information. This presentation is intended for delivery via WebEx/GoToMeeting at the July 8, 2020 meeting of the DOE-sponsored INTERFUEL working group. FAST is a web-based information management tool developed by INL and funded by GSA's Office of Government-wide Policy and DOE's Federal Energy Management Program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Fabrication, and Test of a 5-kWh/100-kW Flywheel Energy Storage Utilizing a High-Temperature Superconducting Bearing

The summaries of this project are: (1) Program goal is to design, develop, and demonstrate a 100 kW UPS flywheel electricity system; (2) flywheel system spin tested up to 15,000 RPM in a sensorless, closed loop mode; (3) testing identified a manufacturing deficiency in the motor stator--overheats at high speed, limiting maximum power capability; (4) successfully spin tested direct cooled HTS bearing up to 14,500 RPM (limited by Eddy current clutch set-up); (5) Testing confirmed commercial feasibility of this bearing design--Eddy Current losses are within acceptable limits; and (6) Boeing's investment in flywheel test facilities increased the spin-test capabilities to one of the highest in the nation.

25 ENERGY STORAGE↗

Northwest Open Automated Demand Response Technology Demonstration Project

The Lawrence Berkeley National Laboratory (LBNL) Demand Response Research Center (DRRC) demonstrated and evaluated open automated demand response (OpenADR) communication infrastructure to reduce winter morning and summer afternoon peak electricity demand in commercial buildings the Seattle area. LBNL performed this demonstration for the Bonneville Power Administration (BPA) in the Seattle City Light (SCL) service territory at five sites: Seattle Municipal Tower, Seattle University, McKinstry, and two Target stores. This report describes the process and results of the demonstration. OpenADR is an information exchange model that uses a client-server architecture to automate demand-response (DR) programs. These field tests evaluated the feasibility of deploying fully automated DR during both winter and summer peak periods. DR savings were evaluated for several building systems and control strategies. This project studied DR during hot summer afternoons and cold winter mornings, both periods when electricity demand is typically high. This is the DRRC project team's first experience using automation for year-round DR resources and evaluating the flexibility of commercial buildings end-use loads to participate in DR in dual-peaking climates. The lessons learned contribute to understanding end-use loads that are suitable for dispatch at different times of the year. The project was funded by BPA and SCL. BPA is a U.S. Department of Energy agency headquartered in Portland, Oregon and serving the Pacific Northwest. BPA operates an electricity transmission system and markets wholesale electrical power at cost from federal dams, one non-federal nuclear plant, and other non-federal hydroelectric and wind energy generation facilities. Created by the citizens of Seattle in 1902, SCL is the second-largest municipal utility in America. SCL purchases approximately 40% of its electricity and the majority of its transmission from BPA through a preference contract. SCL also provides ancillary services within its own balancing authority. The relationship between BPA and SCL creates a unique opportunity to create DR programs that address both BPA's and SCL's markets simultaneously. Although simultaneously addressing both market could significantly increase the value of DR programs for BPA, SCL, and the end user, establishing program parameters that maximize this value is challenging because of complex contractual arrangements and the absence of a central Independent System Operator or Regional Transmission Organization in the northwest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Building Energy Model Creation (AutoBEM) for Urban-Scale Energy Modeling and Assessment of Value Propositions for Electric Utilities

Residential and commercial buildings in the United States consume 73% of all electricity generated. Demand charges (i.e. “peak usage”) can account for 30-70% of a utility bill and continue to grow even as energy prices are decreasing, due largely in part to adoption of intermittent renewables and less efficient, more costly generation assets which must be brought online during peak demand. In order to quantitatively assess business value and either enhance existing or propose new programs for utilities, the ability to detect, generate, and simulate a building energy model has been applied to a 1,385 km2 utility district involving over 160,000 buildings in a smart grid backed by a fiber optic network. The organization operating the electrical distribution and fiber optic networks has prioritized and guided the creation of a virtual utility in order to assess a prioritized list of potential revenue streams and determine the most cost-effective programs for their organization and their rate-payers. We provide an overview of the technical capabilities developed for generally-applicable urban-scale building energy modeling to any geographical area and the utility-defined use cases being assessed.

New, Joshua↗

Conversion of Low-Thrust Airplane Gas-Turbine Engines to Power Generators

The local market demand for generators of electric power and heat of output between 7 kW and 2.5 MW is analyzed. State programs relating to the large-scale use of such generators in industry and utility companies are reviewed. Data for generator imports to Russia between 2014 and 2017 suggest that this demand will outstrip supply in the near future. It is expedient to convert low-thrust airplane gas-turbine engines to power generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

Consumers regularly forgo purchases of high efficiency appliances that appear to be cost effective at a reasonable rate of return. While some argue that this is a true revelation of preferences for appliance features, this 'efficiency gap' can be largely explained by a combination of market and behavioral failures that reduce consumers ability to evaluate the relative value of appliances and skew preferences toward initial cost savings, undervaluing future reductions in operating costs. These failures and barriers include externalities of energy use, imperfect competition between manufacturers, asymmetric information, bounded rationality, split incentives, and transaction costs (Golove 1996). Recognizing the social benefit of energy conservation, several major methods are used by policymakers to ensure that efficient appliances are purchased: minimum efficiency standards, Energy Star labeling, and rebates and tax credits. There is no single market for energy services; there are hundreds of uses, thousands of intermediaries, and millions of users, and likewise, no single appropriate government intervention (Golove 1996). Complementary approaches must be implemented, considering policy and institutional limitations. In this paper, I first lay out the rationale for government intervention by addressing the market and behavioral failures and barriers that arise in the context of residential energy efficiency. I then consider the ways in which some of these failures and barriers are addressed through major federal programs and state and utility level programs that leverage them, as well as identifying barriers that are not addressed by currently implemented programs. Heterogeneity of consumers, lack of financing options, and split incentives of landlords and tenants contribute significantly to the under-adoption of efficient appliances. To quantify the size of the market most affected by these barriers, I estimate the number of appliances, and in particular the number of outdated appliances, in California rental housing. Appliances in rental housing are on average older than those in owner occupied housing. More importantly, a substantial proportion of very old appliances are in rental housing. Having established that a very old stock of appliances exists in California rental housing, I discuss tariff financing as a policy option to reduce the impact of the remaining market and behavioral barriers. In a tariff financing program, the utility pays the initial cost of an appliance, and is repaid through subsequent utility bills. By eliminating upfront costs, tying repayment to the gas or electric meter, requiring a detailed energy audit, and relying upon utility bill payment history rather than credit score in determining participant eligibility, tariff financing largely overcomes many barriers to energy efficiency. Using California as a case study, I evaluate the feasibility of implementing tariff financing. For water heaters in particular, this appears to be a cost-effective strategy. Tariff financing from utilities is particularly valuable because it improves the ability of low-income renters to lower their utility bills, without burdening landlords with unrecoverable capital costs. To implement tariff financing country-wide, regulations in many states defining private loan-making institutions or the allowable use of public benefit funds may need to be modified. Tariff financing is relatively new and in most locations is only available as a pilot program or has only recently exited pilot phase. This preliminary evaluation suggests that tariff financing is a valuable future addition to the toolkit of policymakers who aim to increase the diffusion of efficient appliances. While regulatory approval is necessary in states that wish to pursue tariff financing, at this point, the major barrier to further implementation appears to be the newness of the financing mechanism.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System Advisor Model, SAM 2011.12.2: General Description

This document describes the capabilities of the U.S. Department of Energy and National Renewable Energy Laboratory's System Advisor Model (SAM), Version 2011.12.2, released on December 2, 2011. SAM is software that models the cost and performance of renewable energy systems. Project developers, policy makers, equipment manufacturers, and researchers use graphs and tables of SAM results in the process of evaluating financial, technology, and incentive options for renewable energy projects. SAM simulates the performance of solar, wind, geothermal, biomass, and conventional power systems. The financial model can represent financing structures for projects that either buy and sell electricity at retail rates (residential and commercial) or sell electricity at a price determined in a power purchase agreement (utility). Advanced analysis options facilitate parametric, sensitivity, and statistical analyses, and allow for interfacing SAM with Microsoft Excel or with other computer programs. SAM is available as a free download at http://sam.nrel.gov. Technical support and more information about the software are available on the website.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response Analysis for Different Residential Personas in a Comfort-Driven Behavioral Context

Low demand response (DR) participation and high program drop-out rates continue to impede DR goals that could save up to $13 billion in annual grid expansion and electricity demand costs. Yet, the literature lacks a thorough understanding of how different residential customer segments enrolled in DR programs respond to utility signals in view of occupant comfort considerations. The objective of this study is to gain a clear understanding of the effects of four different customer personas on residential DR. Given current data limitations, this work developed an array of hypothetical personas with varied priorities, activity levels, and comfort thresholds based on demographic variables that have been found in previous studies to influence energy consumption. A BEopt DR model for a reference residential single-family building located in Colorado was built to isolate the effect of differences in buildings or climate. The results provide useful evidence on how persona-comfort differences lead to significant deviations in DR goals (especially peak demand reduction), ranging from 0.1% to 20%. This work presents a novel framework representing comfort preferences in DR models. The data generated, albeit synthetic, and the results could inform DR program design considerations of how different people respond to different comfort priorities.

BEopt↗

ECAR-6584 MARVEL Reactor Support Frame Analysis

Idaho National Laboratory (INL) is developing a small microreactor to produce electrical power utilizing a small nuclear core and Stirling engines for power output under the Microreactor Application Research Validation and Evaluation (MARVEL) program. The MARVEL Reactor will be installed in the Transient Reactor Test (TREAT) Facility. Walsh Engineering Services, PC (WES) has contracted with the INL to support the completion of the final design. There are six main systems in the MARVEL, one of which is the MARVEL Reactor System (MRS). The MRS contains a subsystem – the Reactor Support Frame (RSF) – that supports and orients nearly all the MRS and the RSF will be bolted to the TREAT Facility. The subject of this Engineering Calculations and Analysis Report (ECAR) is the frame weldment (see Figure 1), which is the only item that is contained in the RSF subsystem and will be called herein “RSF”.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ECAR-6585 MARVEL Core Support Structure Analysis: Project #33526

Idaho National Laboratory (INL) is developing a small microreactor to produce electrical power utilizing a small nuclear core and stirling engines for power output under the Microreactor Application Research Validation and Evaluation (MARVEL) program. The MARVEL Reactor (Figure 1) will be installed in the Transient Reactor Test (TREAT) Facility. Walsh Engineering Services, PC (WES) has contracted with the INL to detail the final design. There are six main systems in the MARVEL, one of which is the Fuel and Core System (FCS). The FCS contains a subsystem–the Core Support Structures Subsystem (CSS)–that supports and orients each of the 36 nuclear fuel pins in the MARVEL Reactor System. The FCS (apart from the fixed Beryllium Oxide radial reflectors) is shown in light green and is depicted in more detail in Figure 1 and Figure 2. The main subject of this analysis is the lower grid plate, which is the principal item in the CSS which supports the fuel, see Figure 3. Additionally, the upper grid plate thermal expansion of the upper grid plate is presented in Appendix A.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technoeconomic Opportunity Analysis for Local Power Generation in Falls City, Nebraska

Falls City is a small community in Nebraska interested in understanding how energy from local energy systems could support the community's economic development planning. To address the current community needs and address the future energy demand technical assistance conducted through the Communities Local Energy Action Program (Communities LEAP) assessed the technical and economic opportunities of adding energy technologies to Falls City's municipally owned and operated electric utility system. The modeling performed considered the technical and economic feasibility of technologies using the System Advisor Model (SAM). The modeling explored three technology configurations using multiple years of historical weather and wholesale cost data (2015-2022 & a typical meteorological year), and two different wholesale escalation rates (0.3% and 2.5%). Wholesale energy prices were based on the Southwest Power Pool's (SPP) real-time energy market and the annual escalation rates of these rates based on historical SPP wholesale and national retail electricity price trends. Results from the modeling showed that at current CAPEX costs and SPP wholesale electricity costs no technology combination averaged across the scenarios run provide a positive net present value (NPV). External financial support, changes in market conditions, and additional revenue streams would help create more economically favorable projects. As conditions change re-evaluation may be necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The initiatives of the Los Alamos Scientific Laboratory in the transfer of a new excavation technology

A system for making vertical or horizontal holes in rock or soil by progressive local melting is described. In one operation the three major tasks of excavation are performed with the Subterrene concept: (1) rock fracturing; (2) debris removal; and (3) wall stabilization. Potential applications of the Subterrene system are indicated, with emphasis on extraction of geothermal energy and development of superconduction transmission lines for electrical power. A program in technology dissemination implemented by the staff members is described. It is indicated that a large scale commercial utilization of the technology is required to complete the transfer of technology.

Hanold, R. J.↗

A Framework to Survey the Energy Efficiency of Installed Motor Systems

While motors are ubiquitous throughout the globe, there is insufficient data to properly assess their level of energy efficiency across regional boundaries. Furthermore, many of the existing data sets focus on motor efficiency and neglect the connected drive and system. Without a comprehensive survey of the installed motor system base, a baseline energy efficiency of a country or region’s motor systems cannot be developed. The lack of data impedes government agencies, utilities, manufacturers, distributers, and energy managers when identifying where to invest resources to capture potential energy savings, creating programs aimed at reducing electrical energy consumption, or quantifying the impacts of such programs. This paper will outline a data collection framework for use when conducting a survey under a variety of execution models to characterize motor system energy efficiency within a country or region. The framework is intended to standardize the data collected ensuring consistency across independently conducted surveys. Consistency allows for the surveys to be leveraged against each other enabling comparisons to motor system energy efficiencies from other regions. In creating the framework, an analysis of various motor driven systems, including compressed air, pumping, and fan systems, was conducted and relevant parameters characterizing the efficiency of these systems were identified. A database using the framework will enable policymakers and industry to better assess the improvement potential of their installed motor system base particularly with respect to other regions, assisting in efforts to promote improvements to the energy efficiency of motor driven systems.

Rao, Prakash↗

Status and Trends in U.S. Compliance and Voluntary Renewable Energy Certificate Markets (2010 Data)

This report documents the status and trends of 'compliance'--renewable energy certificate (REC) markets used to meet state renewable portfolio standard (RPS) requirements--and 'voluntary' markets--those in which consumers and institutions purchase renewable energy to match their electricity needs on a voluntary basis. Today, 29 states and the District of Columbia have an RPS, more than half ofall U.S. electricity customers have an option to purchase some type of green power product directly from a retail electricity provider, and all consumers have the option to purchase RECs. This report documents REC activities and trends in the United States. The compliance REC market analysis includes analysis of REC trading, regional REC markets, REC tracking systems, types of compliance RECs,compliance REC pricing trends, and an overview of compliance with RPS polices. The voluntary REC analysis presents data and analysis on voluntary market sales and customer participation, products and premiums, green pricing marketing and administrative expenses, voluntary REC pricing, and the voluntary carbon offsets market. The report concludes with a discussion of upcoming guidance from theFederal Trade Commission on green marketing claims, the emergence of community solar programs, and the potential impact of Dodd-Frank regulations on the REC market.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demand Response in U.S. Electricity Markets: Empirical Evidence

Empirical evidence concerning demand response (DR) resources is needed in order to establish baseline conditions, develop standardized methods to assess DR availability and performance, and to build confidence among policymakers, utilities, system operators, and stakeholders that DR resources do offer a viable, cost-effective alternative to supply-side investments. This paper summarizes the existing contribution of DR resources in U.S. electric power markets. In 2008, customers enrolled in existing wholesale and retail DR programs were capable of providing ~;;38,000 MW of potential peak load reductions in the United States. Participants in organized wholesale market DR programs, though, have historically overestimated their likely performance during declared curtailments events, but appear to be getting better as they and their agents gain experience. In places with less developed organized wholesale market DR programs, utilities are learning how to create more flexible DR resources by adapting legacy load management programs to fit into existing wholesale market constructs. Overall, the development of open and organized wholesale markets coupled with direct policy support by the Federal Energy Regulatory Commission has facilitated new entry by curtailment service providers, which has likely expanded the demand response industry and led to product and service innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗