Major Drivers of Long-Term Distribution Transformer Demand

Distribution transformers, used to step-down medium voltage to service-voltage level for end-use electrical consumption, are currently experiencing major shortages. Utilities are experiencing extended lead times for transformers of up to 2 years (a 4x increase on lead times pre-2022) and prices have gone up by as much as 5-6 times in the past 2 years. Current shortages have been attributed to pent-up post-pandemic demand, workforce shortages and low retention rates, component supply chain challenges, and materials shortages (grain-oriented electrical steel, aluminum, and copper). The supply of this equipment is critical for the reliability and growth of the power system, and in meeting administration climate goals in terms of electrification of demand and the growth of renewable energy. This report details some of the initial analysis conducted by the National Renewable Energy Laboratory (NREL), supported by the Department of Energy's Office of Electricity and Office of Policy, in assessing the long-term demand trends for distribution transformers. Expected increased demand is due to a confluence of not only electrification and renewable energy growth, but also in the context of aging electric infrastructure, increased frequency and severity of extreme weather events, and utility-driven investments in reliability and resiliency of the electricity distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Experimental Capabilities to Support Design, Development and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support non-nuclear demonstration of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the single primary heat extraction and removal emulator (SPHERE) and the microreactor agile non-nuclear experimental test bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes non-contact infrared thermal imaging, surface thermocouples, spatially distributed fiber-optic temperature and strain sensors, electrical power meters, and a water-cooled, gas gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guide for Grid-Interactive Efficient Buildings for Federal Agencies

This guide provides an overview of GEB characteristics and benefits and how to analyze, identify, and implement GEB retrofit opportunities. It is important to understand the building’s systems as well as what utility program offerings are available at the site (e.g., time-of-use, electricity rates, demand charges, demand response programs, etc.). It is also important to understand the key goals for the site (e.g., environmental, cost savings, energy savings) and the current energy usage breakdown by equipment and load profile variability by day, month, and season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic and Cost Analysis for Winston-Salem, North Carolina

This study assesses the feasibility of solar installations at various sites in Winston-Salem, focusing on factors such as solar resource availability, electricity costs, and rooftop area for photovoltaic systems. The analysis begins by estimating daily energy requirements based on annual electricity use, followed by adjusting for seasonal and operational fluctuations. Using regional solar data from the National Solar Radiation Database (NSRDB), we calculate average peak sun hours to determine effective system sizing. A parametric approach using the System Advisor Model (SAM) refines this sizing process, incorporating a safety margin of 1.2 to address demand peaks. Each PV system is designed to fit available rooftop space, and a coverage threshold of 70% is identified as optimal for maximizing cost savings and sustainability. This threshold allows installations to meet substantial energy demands, supporting energy resilience and enhancing economic returns.

14 SOLAR ENERGY↗

Magnetism in Moiré Materials

This project focused on the theory of the electronic properties of magnetic moire materials. Moire materials can be formed by overlaying two or more two-dimensional crystals that are either semiconductors or semimetals and establishing a moire pattern. Low-energy electronic properties are then described by a continuum model with crystalline periodicity. Moire materials are therefore artificial two-dimensional crys- tals whose periodicity is at the tens of nanometers scale, increasing the unit cell area by a factor of about 10,000 compared to real crystals. They are important because the main tuning knob of chemistry, the number of electrons per effective atom or molecule (the analog of the number of electrons per unit cell in real crystals), can be shifted by more than one simply by using electrical gates. The research covered two diffeerent classes of moire materials, graphene multilayers twisted to a rotation angle at which correlations are strong, and transition metal dichalcogenide semiconductors. The proposal identifed one project in each area both related very broadly to magnetism: i) Advancing understanding of broken spin-valley and sublattice symmetries in Magic Angle Twisted Bilayer Graphene and ii) Developing the theory of itinerant electron magnetism in Gamma-valley and K-valley transition metal dichalcogenide moire materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comprehensive Life Cycle Analysis of Methanol Production and Methanol-to-Diesel Conversion

Methanol is a strategic chemical and intermediate in the manufacture of synthetic diesel, due to its versatility, diesel’s compatibility with existing infrastructure, and their role in industrial and transport applications. Conventional production methods for methanol, primarily steam methane reforming (SMR), rely on natural gas and are subject to the price variability due to market conditions and geopolitical events. They are also associated with greenhouse gas (GHG) emissions. Methanol and synthetic diesel production could be integrated with nuclear energy to stabilize fuel prices and insulate pricing from outside geopolitical events due to the relative stability of nuclear fuel as compared to natural gas. This could lead to increased transportation fuel security, reliability and resilience. An added benefit is the abatement of emissions when substituting nuclear energy for conventional energy from natural gas. This report presents a comprehensive life cycle analysis(LCA) framework which was developed to evaluate the GHG emissions reduction potential associated with nuclear integrated methanol production, methanol-to-diesel upgrading, and end-use combustion. Gate-to-gate methanol production and cradle-to-grave emissions were evaluated in, starting with a business-as-usual (BAU) SMR-based methanol plant, and then considering stepwise nuclear integration. Methanol-to-diesel (MTD) conversion was evaluated accounting for nuclear energy integration and hydrogen production via high-temperature steam electrolysis (HTSE) using electricity either from the grid or from a dedicated nuclear power system. This multi-step process diverts stable and reliable nuclear energy into the transportation sector by upgrading low energy dense natural gas into liquid fuels fully compatible with existing infrastructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bridging the length scales in ionic separations via data-driving machine learning

We pursued a data science driven machine learning (ML) approach that blended molecular scale attributes informed from molecular dynamics (MD) simulation and materials properties to the selectivity and energy efficiency in targeted ionic separations using electric fields. The model mixtures investigated for ionic separations are pH sensitive and include organic acids, silica and boron, transition metals, such as copper and chromium. There were two major research thrusts of this project. Firstly, we investigated surrogate models and deep learning that relate material chemistries and structures to selective transport of ionic species under applied electric fields. Secondly we investigated how the bipolar junction interfacial design and water dissociation catalyst in bipolar membranes affect reverse bias polarization behavior and pH modulation in deionization platforms as a function of the platform operating parameters (e.g., cell voltage, residence time, and salt feed concentration). As a result of this work, we also were able to start a new direction, namely ML models for molecular design of surfactants.

36 MATERIALS SCIENCE↗

Dilute Paramagnetism and Non-Trivial Topology in Quasicrystal Approximant Fe4Al13

A very fundamental property of both weakly and strongly interacting materials is the nature of their magnetic response. In this work, we detail the growth of crystals of the quasicrystal approximant Fe4Al13 with an Al flux solvent method. We characterize our samples using electrical transport and heat capacity, yielding results consistent with a simple non-magnetic metal. However, magnetization measurements portray an extremely unusual response for a dilute paramagnet and do not exhibit the characteristic Curie behavior expected for a weakly interacting material at high temperature. Electronic structure calculations confirm metallic behavior but also indicate that each isolated band near the Fermi energy hosts non-trivial topologies, including strong, weak, and nodal components, with resultant topological surface states distinguishable from bulk states on the (001) surface. With half-filled flat bands apparent in the calculation, but an absence of long-range magnetic order, the unusual quasi-paramagnetic response suggests the dilute paramagnetic behavior in this quasicrystal approximant is surprising and may serve as a test of the fundamental assumptions that are taken for granted for the magnetic response of weakly interacting systems.

Avers, Keenan E. (ORCID:0000000223441939)↗

Liquid Copper and Iron Production from Chalcopyrite, in the Absence of Oxygen

Clean energy infrastructure depends on chalcopyrite: the mineral that contains 70% of the world’s copper reserves, as well as a range of precious and critical metals. Smelting is the only commercially viable route to process chalcopyrite, where the oxygen-rich environment dictates the distribution of impurities and numerous upstream and downstream unit operations to manage noxious gases and by-products. However, unique opportunities to address urgent challenges faced by the copper industry arise by excluding oxygen and processing chalcopyrite in the native sulfide regime. Through electrochemical experiments and thermodynamic analysis, gaseous sulfur and electrochemical reduction in a molten sulfide electrolyte are shown to be effective levers to selectively extract the elements in chalcopyrite for the first time. We present a new process flow to supply the increasing demand for copper and byproduct metals using electricity and an inert anode, while decoupling metal production from fugitive gas emissions and oxidized by-products.

36 MATERIALS SCIENCE↗

Multi-modular power plant with off-grid power source

A multi-modular power plant may include a plurality of on-site nuclear power modules configured to generate a power plant output, wherein one or more of the nuclear power modules may be designated as service module units which are configured to generate a first portion of the power plant output. A remainder of the nuclear power modules may be configured to generate a second portion of the power plant output. A number of power plant systems may be configured to operate using electricity associated with a house load of the power plant, wherein the first portion of the power plant output is equal to or greater than the house load. Additionally, a switchyard may be configured to electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers, and the switchyard may be configured to apply the second portion of the power plant output to the distributed electrical grid. The switchyard may further be configured to apply at least part of the first portion of the power plant output to the power plant systems during a loss of power from the distributed electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Dynamic clay microstructures emerge via ion complexation waves

Clays control carbon, water and nutrient transport in the lithosphere, promote cloud formation5 and lubricate fault slip through interactions among hydrated mineral interfaces. Clay mineral properties are difficult to model because their structures are disordered, curved and dynamic. Consequently, interactions at the clay mineral-aqueous interface have been approximated using electric double layer models based on single crystals of mica and atomistic simulations. We discover that waves of complexation dipoles at dynamically curving interfaces create an emergent long-range force that drives exfoliation and restacking over time- and length-scales that are not captured in existing models. Curvature delocalizes electrostatic interactions in ways that fundamentally differ from planar surfaces, altering the ratio of ions bound to the convex and concave sides of a layer. Multiple-scattering reconstruction of low-dose energy-filtered cryo electron tomography enabled direct imaging of ion complexes and electrolyte distributions at hydrated and curved mineral interfaces with {\aa}ngstrom resolution over micron length scales. Layers exfoliate and restack abruptly and repeatedly over timescales that depend strongly on the counterion identity, demonstrating that the strong coupling between elastic, electrostatic and hydration forces in clays promote collective reorganization previously thought to be a feature only of active matter.

Whittaker, Michael L↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection: Preprint

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

The National Climate Data Base (NCDB): A Bias-Corrected High-Resolution Climate Dataset

Assessing renewable energy resources under future climate scenarios has been highlighted in recent years to analyze and understand potential impacts of future change in renewable generation on the power sector. Solar energy is well-known as the most plentiful among various renewable resources and usually converted to electricity using photovoltaics (PV) technologies, and the global deployment of PV technology has increased rapidly in recent decades. In this study, we develop a statistical technique to downscale the future projection of solar irradiance for PV energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the proposed downscaling method and future extension of this research.

climate data↗