Search NASA⌕ Search

SEARCH · Search NASA

Results for “end of discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High-resolution, VUV (147-201 nm) photoabsorption cross sections for C2H2 at 195 and 295 K

Results of measurements of photoabsorption cross sections of acetylene at 195 and 295 K in the wavelength range of 147-201 nm are reported. Short-wavelength data are obtained at 0.002 nm intervals, but no structure was observed on that scale. Emission and absorption lines from contaminant species in xenon and hydrogen discharges are used to determine the correct wavelength scale for the data. The uncertainty in the relative wavelengths is estimated to be about 0.004 nm, whereas the absolute wavelength values are accurate to + or - 0.043 nm. No significant photodestruction of C2H2 was found during the measurements. Cross-section values determined at the beginning portions of the measurements are indistinguishable from the values determined at the ends, thus demonstrating that there was no loss of absorbers.

Smith, Peter L.↗

Energy Efficient Waste Heat Coupled Forward Osmosis for Effluent Water Management at Coal-Fired Power Plants

This project sought to evaluate the technical and economic viability of the Aquapod©, a transformational low energy (<200 kJ/kg water) waste heat coupled forward osmosis (FO) technology, to manage effluents, meet cooling water demands, and achieve water conservation in a coal-fired power plant environment. The Aquapod© process is innovative because it is heat-driven, avoids the evaporation of water, and uses no toxic chemicals such as ammonia or amines. The Aquapod© process accomplishes this using an aqueous two-phase system (ATPS) coupled FO process. The evaluation revealed that the Aquapod© process offers a pathway to exploit waste heat resources within a power plant to achieve flue-gas desulfurization (FGD) wastewater volume reduction and water recovery with minimal pretreatment. Water recovery of 80% from FGD wastewater was achieved with minimal pretreatment, exceeding the project target of 50%. The estimated electrical energy of 2.16 kWh/m 3 of water produced for the Aquapod© process met the project target of < 3.6 kWh/m 3 . The heat required for the process operation was approximately 186 kJ/kg of produced water, which was slightly lower than the project target of 200 kJ/kg. The estimated treatment cost for installing and operating the Aquapod© process in conjunction with a spray dryer evaporator to achieve zero-liquid discharge (ZLD) of the 100 gpm FGD wastewater was $13.24/m 3 over a 30-year lifetime. As a point of reference, this study’s host power plant currently incurs a cost of $3.70/m 3 – $8.87/m3 on a discharged volume basis to discharge its wastewater into the publicly owned treatment works (POTW) after physical-chemical treatment. Therefore, the Illinois power plant would incur an incremental cost increase of $4.37/m 3 – 9.54/m 3 to achieve ZLD using the Aquapod© and spray dryer combination. Ample opportunities exist to further lower the ZLD capital and operating costs in the next design iteration to attain pipe parity at the higher end of the site treatment costs.

01 COAL, LIGNITE, AND PEAT↗

A Study on Advanced Lithium-Based Battery Cell Chemistries to Enhance Lunar Exploration Missions

NASAs Exploration Technology Development Program (ETDP) Energy Storage Project conducted an advanced lithium-based battery chemistry feasibility study to determine the best advanced chemistry to develop for the Altair Lunar Lander and the Extravehicular Activities (EVA) advanced Lunar surface spacesuit. These customers require safe, reliable batteries with extremely high specific energy as compared to state-of-the-art. The specific energy goals for the development project are 220 watt-hours per kilogram (Wh/kg) delivered at the battery-level at 0 degrees Celsius ( C) at a C/10 discharge rate. Continuous discharge rates between C/5 and C/2, operation between 0 and 30 C and 200 cycles are targeted. Electrode materials that were considered include layered metal oxides, spinel oxides, and olivine-type cathode materials, and lithium metal, lithium alloy, and silicon-based composite anode materials. Advanced cell chemistry options were evaluated with respect to multiple quantitative and qualitative attributes while considering their projected performance at the end of the available development timeframe. Following a rigorous ranking process, a chemistry that combines a lithiated nickel manganese cobalt oxide Li(LiNMC)O2 cathode with a silicon-based composite anode was selected as the technology that can potentially offer the best combination of safety, specific energy, energy density, and likelihood of success.

Reid, Concha M.↗

Development and Implementation of a Hardware In-the-Loop Test Bed for Unmanned Aerial Vehicle Control Algorithms

Successful prediction and management of battery life using prognostic algorithms through ground and flight tests is important for performance evaluation of electrical systems. This paper details the design of test beds suitable for replicating loading profiles that would be encountered in deployed electrical systems. The test bed data will be used to develop and validate prognostic algorithms for predicting battery discharge time and battery failure time. Online battery prognostic algorithms will enable health management strategies. The platform used for algorithm demonstration is the EDGE 540T electric unmanned aerial vehicle (UAV). The fully designed test beds developed and detailed in this paper can be used to conduct battery life tests by controlling current and recording voltage and temperature to develop a model that makes a prediction of end-of-charge and end-of-life of the system based on rapid state of health (SOH) assessment.

Battery Testbed↗

Method and apparatus for fluffing, separating, and cleaning fibers

A perforated tube is housed in a chamber in which vacuum is drawn. An air jet is directed into one end of the tube and fiber bundles are fed into the jet which separates and dispenses individual fibers from the bundle, fluffs them, cleanses them of any particulate material, and carries them into the tube. The tube retains the fibers while fiber fragments, undesirably short fibers and particulate matter are drawn by the vacuum and resultant air flow out of the tube through its perforations to a suitable discharge.

Padilla, D.↗

Results of a 1462 hour ammonia arcjet endurance test

A total of 1462 hours of operaton were demonstrated in an endurance test of a 30 kWe-class ammonia arcjet operated at 10 kWe. The propellant flow rate was 0.170 g/s, and the measured performance increased from approximately 650 s specific impulse at 36 percent efficiency at the beginning of the test to 675 s at 39 percent near the end. The voltage increased and the current dropped slightly over the first 400 hours, and then remained approximately constant for the remainder of the test. The test, scheduled for 1500 hours, was terminated after an insulator in the rear of the engine failed. Post-test examination of the electrodes revealed only minimal damage. Although there was evidence of a number of mass transport processes occurring in the discharge chamber, the primary life-limiting wear mechanisms appear to be cathode tip erosion and constrictor melting.

Polk, J. E.↗

Direct Electrolytic Deposition of Mats of Mn(x)O(y) Nanowires

Mats of free-standing manganese oxide (MnxOy) nanowires have been fabricated as experimental electrode materials for rechargeable electrochemical power cells and capacitors. Because they are free-standing, the wires in these mats are electrochemically accessible. The advantage of the mat-of-nanowires configuration, relative to other configurations of electrode materials, arises from the combination of narrowness and high areal number density of the wires. This combination offers both high surface areas for contact with electrolytes and short paths for diffusion of ions into and out of the electrodes, thereby making it possible to charge and discharge at rates higher than would otherwise be possible and, consequently, to achieve greater power densities. The nanowires are fabricated in an electrolytic process in which there is no need for an electrode binder material. Moreover, there is no need to incorporate an electrically conductive additive into the electrode material; the only electrically conductive material that must be added is a thin substrate contact film at the anchored ends of the nanowires. Hence, the mass fraction of active electrode material is close to 100 percent, as compared with about 85 percent in conventional electrodes made from a slurry of active electrode material, binder, and conductive additive pressed onto a metal foil. The locations and sizes of the nanowires are defined by holes in templates in the form of commercially available porous alumina membranes. In experiments to demonstrate the present process, alumina membranes of various pore sizes and degrees of porosity were used. First, a film of Au was sputtered onto one side of each membrane. The membranes were then attached, variously, to carbon tape or a gold substrate by use of silver or carbon paste. Once thus attached, the membranes were immersed in a plating solution comprising 0.01 M MnSO4 + 0.03 M (NH4)2SO4. The pH of the solution was kept constant at 8 by addition of H2SO4 or NH4OH as needed. Mn(x)O(y) nanowires were potentiostatically electrodeposited in the pores in the alumina templates. Depending on the anodic deposition potentials, Mn(x)O(y) was deposited in various oxidation states [divalent (Mn3O4), trivalent (Mn2O3), or tetravalent (MnO2)]. The Mn(x)O(y) wires were made free-standing (see figure) by dissolving the alumina templates, variously, in KOH or NaOH at a concentration of 20 volume percent.

Myung, Nosang↗

A Convolutional Neural Network Model for Battery Capacity Fade Curve Prediction using Early Life Data

Herein, early prediction of battery performance degradation trends can facilitate research of new materials and cell designs, rapid deployment of batteries in real-world applications, timely replacement of batteries in critical applications, and even the secondary use market. In this study, we design a convolutional neural network model to predict the entire battery capacity fade curve - a critical indicator of battery performance degradation - using first 100 cycles of data (~ three weeks of testing). We use the discharge voltage-capacity curves as input to the model and automate the feature extraction process through the convolutional layers of the network. Our approach can predict the per cycle capacity fade rate and rollover cycle (knee point) in the capacity fade curve, which indicate the onset of rapid capacity decay. On the publicly available graphite/LiFePO 4 battery dataset, optimized networks predict the capacity fade curves, rollover cycle, and end of life with 3.7% (worst-case), 19%, and 17% mean absolute percentage errors, respectively.

25 ENERGY STORAGE↗

Evolution of lithium ordering with (de)-lithiation in β-LiVOPO 4 : insights through solid-state NMR and first principles DFT calculations

The lithium-ion battery cathode material β-VOPO 4 is capable of intercalating more than one Li ion per transition metal ion due to the accessibility of both the V 5+ /V 4+ and V 4+ /V 3+ redox couples at ~4.5 V and ~2.3 V vs. Li, respectively, giving a theoretical capacity greater than ~300 mA h g -1 . The ability to perform full and reversible two Li-ion intercalation in this material, however, has been a matter of debate and the poor crystallinity of the fully lithiated phase has thus far precluded its complete structural characterisation by conventional diffraction-based methods. In this work, 7 Li and 31 P NMR spectroscopy, in combination with first principles DFT calculations, indicate that chemical lithiation results in a single phase β-Li 2 VOPO 4 exhibiting a complex Li ordering scheme with lithium ions occupying multiple disordered environments. 2D NMR 7 Li correlation experiments were used to deduce the most likely Li ordering for the β-Li 2 VOPO 4 phase from amongst several DFT optimised structures. In contrast, electrochemically lithiated β-Li 2- x VOPO 4 discharged to 1.6 V exhibits, in addition to β-Li 2 VOPO 4 , a β-Li 1.5 VOPO 4 phase. Additionally, the existence of β-Li 1.5 VOPO 4 is not reflected in the flat galvanostatic charge and discharge curves nor is evident from diffraction-based methods due to the very close structural similarity between the β-Li 1.5 VOPO 4 phase and β-Li 2 VOPO 4 phases. We demonstrate that solid state NMR spectroscopy, in combination with DFT results, provides a powerful tool for identifying intermediate states formed during charge/discharge of these complex phosphates as these phases can be distinguished from the end member phases primarily by the nature of the lithium ordering.

25 ENERGY STORAGE↗

Gamma Irradiation of NaCl-UCl 3 Salt for the Molten Chloride Fast Reactor

This report documents the results of the gamma ray irradiation of NaCl-UCl 3 eutectic salt in the Advanced Test Reactor (ATR) spent fuel pool gamma tube and subsequent analysis of capsules utilizing the Gas Assay Sample and Recharge (GASR) system. NaCl-UCl 3 salt capsules at four different temperatures, 75C, 150C, 300C and 600C, were irradiated shortly after the core internal changeout (CIC) of the ATR, beginning April 28 th of 2021, and ending on August 18 th of 2021. Re-positioning of the fuel elements in the spent fuel pool to move more fresh fuel elements around the gamma tube occurred on May 11 th of 2021, resulting in an approximate 20% increase in the dose rate and consequently the total absorbed dose. In total, the salt-filled capsules underwent 2638 hours of gamma irradiation from the adjacent freshly discharged ATR spent fuel. Capsule internal pressure measurements were taken via the Gas Assay Sample and Recharge (GASR) system in the INL Hot Fuels Examination Facility (HFEF) following completion of the irradiation. Based on the GASR analysis results, the primary conclusion from this experiment to-date is that radiolytic generation of chlorine gas is insignificant for the dose rates and total absorbed dose that these samples experienced. To elucidate more detailed effects of radiolysis on NaCl-UCl 3 eutectic salts and reach a more definitive conclusion, further advanced analyses such as electron microscopy, simultaneous thermal analysis, and electron paramagnetic resonance are recommended to analyze the capsule wall and salt samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstruction and interpretation of ionization asymmetry in magnetic confinement via synthetic diagnostics

Abstract Strong poloidal refueling asymmetry in the DIII-D tokamak is inferred from line radiation measurements. Synthetic diagnostics in neutral transport modeling coupled to gyrokinetic simulations illuminate implications for the plasma flow profile in the scrape-off layer of single-null beam-driven discharges. Recycling occurs primarily either on the inner or outer divertor legs, depending on the toroidal magnetic field direction. By reversing the toroidal magnetic field, the observed line radiation asymmetry is nearly eliminated or reversed. It is determined that, while relatively simple physics can describe the observed ionization asymmetry, predicting the overall brightness of the hydrogenic Lyman- α signal requires detailed simulation of the plasma and resulting turbulence. To this end, kinetic plasma simulations fully coupled to comprehensive neutral transport calculations—a novel capability—provide first-principles reproduction of Lyman- α observations on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

OAO-3 end of mission power subsystem evaluation

End of mission tests were performed on the OAO-3 power subsystem in three component areas: solar array, nickel-cadmium batteries and the On-Board Processor (OBP) power boost operation. Solar array evaluation consisted of analyzing array performance characteristics and comparing them to earlier flight data. Measured solar array degradation of 14.1 to 17.7% after 8 1/3 years is in good agreement with theortical radiation damage losses. Battery discharge characteristics were compared to results of laboratory life cycle tests performed on similar cells. Comparison of cell voltage profils reveals close correlation and confirms the validity of real time life cycle simulation. The successful operation of the system in the OBP/power boost regulation mode demonstrates the excellent life, reliability and greater system utilization of power subsystems using maximum power trackers.

Tasevoli, M.↗

Elemental Analyses of Hypervelocity Microparticle Impact Sites on Interplanetary Dust Experiment Sensor Surfaces

The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to breakdown the 0.4 or 1.0 micron thick SiO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results classification resulted from the particles' origins as 'manmade', 'natural', or 'indeterminate'. The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters, of these features. Thus far, a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF were analyzed: 36 from tray C-9 (Leading (ram), or east, side), 18 from tray C-3 (Trailing (wake), or west, side), 12 from tray B-12 (north side), 4 from tray D-6 (south side), 3 from tray H-11 (space end), and 6 from tray G-10 (earth end). Residue from manmade debris was identified in craters on all trays (aluminum oxide particle residues were not detectable on the Al/Si substrates). These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the west, space, and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the east, north, and south sides of the satellite, denoting passage through orbital debris clouds or rings.

Simon, C. G.↗

Charge-Dissipative Electrical Cables

Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

Kolasinski, John R.↗

Temporal Patterns in Soil Redox Potential Vary Across a Freshwater Coastal Delta

Widespread and persistent flooding is submerging coastal ecosystems, particularly along the Louisiana Gulf coast, where flooding results from the compounding effects of ground subsidence and rising sea level. Restoration projects aim to mitigate land loss by diverting sediment loads from rivers into degraded areas to increase ground elevation. To predict how coastal ecosystems will change over time in response to projected changes in relative sea level and restoration, it is necessary to understand how subsurface biogeochemical processes respond to dynamic hydrologic forcings. Here, this study evaluates how environmental parameters that integrate biogeochemical processes vary with water table fluctuations in the freshwater Wax Lake Delta (WLD) in Louisiana, USA, where water diversions have formed one of the only active deltas along the coast. High‐frequency observations of water level, soil redox potential, specific conductance and pH were made for 1 year along elevation transects located on the older, proximal and younger, distal ends of a deltaic island. Redox responded rapidly to changing water tables, with fluctuations occurring primarily in shallow soils (< 20 cm) and at higher elevations. Deeper soils and those at lower elevation remained inundated and reduced. Semi‐diurnal tidal fluctuations were pronounced in younger, distal soils, presumably due to rapid groundwater exchange with the river channel. Tidal signals were muted in older soils that instead exhibited seasonal variability associated with river discharge and evapotranspiration. Although much of the delta sediments are persistently reducing and anoxic, redox fluctuations in the natural levees that border the deltaic islands likely drive high rates of biogeochemical activity. Evaluating how hydrology drives the frequency and duration of redox fluctuations provides a basis for understanding how biogeochemical processes might vary with complex hydrological interactions in coastal systems.

Herndon, Elizabeth [Oak Ridge National Laboratory ↗

Plasma research in electric propulsion at Colorado State University

The effect of electron bombardment ion thruster magnetic field configurations on the uniformity of the plasma density and the ion beam current density are discussed. The optimum configuration is a right circular cylinder which has significant fields at its outer radii and one end but is nearly field free within the cylinder and at the extraction grid end. The production and loss of the doubly charged ions which effect sputtering damage within thrusters are modeled and the model is verified for the mercury propellant case. Electron bombardment of singly charged ions is found to be the dominant double ion production mechanism. The low density plasma (approx. one million elec/cubic centimeter which exists in the region outside of the beam of thrust producing ions which are drawn from the discharge chamber is discussed. This plasma is modeled by assuming the ions contained in it are generated by a charge exchange process in the ion beam itself. The theoretical predictions of this model are shown to agree with experimental measurements.

Wilbur, P. J.↗

Elemental analyses of hypervelocity microparticle impact sites on Interplanetary Dust Experiment sensor surfaces

The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to break down the 0.4 or 1.0 micron thick SIO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle impact sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results were used to classify the particles' origins as 'manmade,' 'natural,' or 'indeterminate.' The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters of these features. Thus far a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF have been analyzed: 36 from tray C-9 (Leading (ram), or East, side), 18 from tray C-3 (Trailing (wake), or West, side), 12 from tray B-12 (North side), 4 from tray D-6 (South side), 3 from tray H-11 (Space end), and 6 from tray G-10 (Earth end). Residue from manmade debris was identified in craters on all trays. (Aluminum oxide particle residues were not detectable on the Al/Si substrates.) These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the West, Space and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the East, North, and South sides of the satellite, denoting passage through orbital debris clouds or rings.

Simon, Charles G.↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗