Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy efficiency measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Measuring the maximum capacity and thermal resistances in phase-change thermal storage devices

Thermal energy storage can increase the efficiency of the electric grid by adding flexibility to thermal systems. The value of thermal storage is a function of its energy and power density, which are driven by the capacity and thermal resistances in the storage device. Measuring these properties in-situ at the device level is an important step to understanding the performance and improving the design of thermal storage systems. Here, we present methods to measure the total capacity and thermal resistances in heat exchangers with integrated phase change materials. These methods are demonstrated on two thermal storage devices - a 570-kWh ice-based storage tank and a 0.35-kWh graphite-tetradecane composite device. The results show how thermal resistances evolve with the state of charge and discharge rate in these devices and quantify the impact of applied pressure on the contact resistance in composite phase change material heat exchangers. The proposed method allows for easy comparison between different systems and provides information on the thermal bottlenecks limiting performance. Ultimately, these measurements will allow designers to make robust, high-performance thermal storage devices for next-generation thermal systems.

25 ENERGY STORAGE↗

Thermoelectric Temperature Measurement of Deforming Solids

Sold phase processing (SPP) utilizes large deformations and elevated but sub-melting temperatures to process materials in an energy-efficient manner to achieve high-performance properties. Studying the fundamental material science and kinetics requires an accurate temperature history of the process, but accurately measuring temperature at the point of deformation is very difficult. This study uses the thermoelectric principle to allow for the direct measurement of a deforming surface by turning the workpieces themselves into the measurement device. By so doing, results measured temperatures are closer to the actual deforming interface, more accurate, more responsive, and more reliable than corresponding measurements taken with standard thermocouples.

36 MATERIALS SCIENCE↗

Mobility Energy Productivity (MEP) Metric: Partnerships, Applications, and Key Enhancements

The Mobility Energy Productivity (MEP) metric is a holistic measure of transportation systems performance that quantifies the ability of individuals to reach destinations in a cost-efficient and energy-efficient manner. This presentation highlights recent partnerships that have advanced the adoption of MEP as a decision-support tool by various agencies, stakeholders, and researchers. Applications include evaluating multimodal accessibility, comparing system-level energy impacts, and informing infrastructure investment strategies. Key enhancements to the metric - such as expanded regional applications and incorporation of emerging technologies - are also discussed. Together, these efforts highlight the potential of MEP to inform data-driven decisions that shape future transportation systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

If One GEB is Good, a Community of GEBs is Better

Energy efficient, connected, grid-interactive, smart and flexible buildings are key to decarbonization, lowering energy use and improving the nation’s electricity grid. The U.S. Department of Energy’s Connected Communities initiative works to demonstrate how coordinated groups of highly efficient buildings combined with other distributed energy resources (DERs), such as electric vehicle (EV) charging, batteries, storage, demand response and photovoltaic (PV) generation can reliably and cost-effectively serve as grid assets by strategically deploying efficiency and demand flexibility while reducing carbon emissions. In 2021, DOE competitively awarded $61 million to a diverse portfolio of 10 pilot projects to promote grid-interactive efficient buildings (GEBs) working together to reliably and cost-effectively serve as grid assets while decarbonizing. Two of the main tenets of the program are measuring the communities’ energy and carbon performance and understanding how to replicate project successes in other communities. This paper begins with a discussion of what Connected Communities are (including a brief history) and their many benefits, including reduced carbon emissions and increased building efficiency and demand flexibility. Next, it provides an overview of the 10 projects, highlighting the diversity of approaches to measure success and replicate the projects: geographic locations; building types; utility, regulatory, market environments; and building vintages that will be used to test the ability of buildings to serve as grid resources. It concludes with a discussion of anticipated project impacts and the metrics that will be used to evaluate the Connected Communities projects.

Nemtzow, David↗

Rate Coefficients for OH + NO (+N 2 ) in the Fall-off Regime and the Impact of Water Vapor

The termolecular, association reaction between OH and NO is a source of nitrous acid (HONO), an important atmospheric trace gas. Rate coefficients for the title reaction as recommended by evaluation panels differ substantially at the temperatures and pressures that prevail in the Earth’s boundary layer where the reaction is in the fall-off regime between low- and high-pressure limiting rate coefficients. Using pulsed laser methods for generation and detection of OH, we have reinvestigated the kinetics of the title reaction at pressures of 22–743 Torr (1 Torr = 1.333 hPa) and temperatures (273, 298, and 333 K) in pure N 2 and in N 2 –H 2 O bath gases. In situ optical absorption measurements were used to rule out any bias due to NO 2 or HONO impurities. Our rate coefficients (k 1 ) in N 2 bath gas are parametrized in terms of low-pressure (k o ) and high-pressure (k ∞ ) rate coefficients and a fall-off parameter (F C ) with k 1,0 N 2 = 7.24 × 10 –31 (T/300 K) –2.17 cm 6 molecule –2 s –1 , k 1,∞ = 3.3 × 10 –12 (T/300 K) –3 cm 3 molecule –1 s –1 , and F C = 0.53. Used with the “Troe” expression for termolecular reactions, these parameters accurately reproduce the current data in the fall-off regime and also capture literature rate coefficients at extrapolated temperatures. The presence of water vapor was found to enhance the rate coefficients of the title reaction significantly. The low-pressure limiting rate coefficient in H 2 O bath gas is a factor 5–6 larger than in N 2 , at room temperature (k 1,o H 2 O = 4.55 × 10 –30 (T/300 K) –4.85 cm 6 molecule –2 s –1 ) indicating that H 2 O is much more efficient in quenching the association complex HONO* through collisional energy transfer. Based on measurements in N 2 –H 2 O mixtures, a parametrization of k 1 including both N 2 and H 2 O as third-body quenchers was derived. Neglecting the effect of H 2 O results, e.g., in an underestimation of k 1 by >10% in the tropical boundary layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of proton capture in the A=100–110 mass region: Constraints on the In 111 (γ,p)/(γ,n) branching point relevant to the γ process

The γ process is an explosive astrophysical scenario, which is thought to be the primary source of the rare proton-rich stable p nuclei. However, current γ-process models remain insufficient in describing the observed p-nuclei abundances, with disagreements up to two orders of magnitude. A sensitivity study has identified 111 In as a model-sensitive (γ,p)/(γ,n) branching point within the γ process. Constraining the involved reaction rates may have a significant impact on the predicted p-nuclei abundances. Here we report on measurements of the cross sections for 102 Pd (p,γ) 103 Ag, 108 Cd (p,γ) 109 In, and 110 Cd (p,γ) 111 In reactions for proton laboratory energies 3–8 MeV using the high efficiency total absorption spectrometer and the γ-summing technique. These measurements were used to constrain Hauser-Feshbach parameters used in talys 1.9, which constrains the 111 In(γ,p) 110 Cd and 111 In(γ,n) 110 Ag reaction rates. The newly constrained reaction rates indicate that the 111 In(γ,p)/(γ,n) branching point occurs at a temperature of 2.71 ± 0.05 GK, well within the temperature range relevant to the γ process. These findings differ significantly from previous studies and may impact the calculated abundances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accurate calibration of thermophotovoltaic efficiency

Abstract The new record efficiency in Thermophotovoltaics relies upon a highly reflective rear mirror. The excellent rear mirror boosts voltage by enhancing the luminescence extraction, and separately also reflects low energy photons, which would otherwise be useless in thermophotovoltaics. The reflected low energy photons reheat the thermal emitter, and regenerate above-bandgap energy photons. The efficiency calibration for such regenerative thermophotovoltaics depends on several factors, yet predominantly on the accurate measurement of the rear mirror reflectivity. Here, we report on the technique for accurate measurement of mirror reflectivity, and of record thermophotovoltaic efficiency 29.1 ± 0.6%, at 1207 °C.

14 SOLAR ENERGY↗

Smart, Connected Manufactured Housing Solutions through High-Performance Design. Final CRADA report

This report focuses on HVAC, domestic hot water, and miscellaneous electric loads via voluntary opportunities that may arise from partnerships with utilities, as well as future US Environmental Protection Agency ENERGY STAR and DOE Zero Energy Ready Manufactured Home programs. Phase I of this project has begun the technical dialogue toward developing an implementation plan among DOE’s Oak Ridge National Laboratory, Clayton Manufactured Homes, and US Department of Housing and Urban Development Code manufactured housing stakeholders. These activities have focused on delivering high-performance design through integration of technology. Project tasks include the following: Identifying baseline energy analysis resources opportunities from a variety of DOE and utility stakeholders; Developing a smart home and business solution by leveraging existing utility programs working with Smart Homes Partners resources such as ACE IoT Solutions, Google Nest, and Ecobee; Developing improved smarter ventilation systems with industry ventilation partners such as the Madison Group; Developing improved building science QA/QC testing equipment with manufacturers such as The Energy Conservatory, and supporting other feasible concepts vetted under DOE’s Advanced Buildings Collaborative with Slipstream, reinventing HVAC in manufactured housing; and, Developing smart home short- and long-term viable technical solutions in coordination with Clayton Manufactured Homes in new and/or revitalized community scales for future Phase II prototype demonstrations, which may include design (and perhaps construction) of single-section homes targeting rental property developers and multi-section homes targeting low- to middle-income affordable housing community developers Given the ongoing US Department of Energy (DOE) rulemaking activities, baseline energy analysis assessments of envelope prescriptive and Uo (i.e., the overall thermal energy efficiency of the home in British thermal units per square foot of exterior heat loss/gain surfaces) measures were removed from the scope of Phase I of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rheological Characterization of Biomass Feedstock for Alternative Energy Applications

With the increased necessity of alternative energy resources, bulk feedstock biomass materials were characterized with the purpose of replacing depleting energy supplies such as fossil fuels and other nonrenewable energy sources. Residual organic waste material (biomass) left over from agricultural processing and handling systems was recycled, and further investigated for renewable energy use. Understanding the scope of flowability for biomass material yielded more efficient, and economical crop harvesting, transporting, and storing method design for the agricultural industry. The effects of moisture on bulk solid flowability was investigated using a variety of parametric testing methods that measure basic flowability energy, and other properties such as compressibility and material resistance. In an industry where organic material is a wasteful byproduct, converting this biomass material into a new energy source and streamlining efficiently for innovative agricultural development supports a clean, renewable energy approach to everyday nonrenewable energy uses, such as oil, propane, and coal. As observed from the repeatable results from the investigated rheological material properties, biomass is an incredibly diverse material that requires modern engineering solutions to revolutionize biomass into a renewable energy source. Biomass will decarbonize petroleum (nonrenewable) derived fuels and chemicals, yielding recyclable carbon. This push to replace fossil fuels with recycled carbon is ideal because of the abundant, renewable, and otherwise agricultural waste of corn stover material. Decarburization, and reduction of C0 2 emissions reduces the effects of global warming.

09 BIOMASS FUELS↗

Dynamic Undervolting to Improve Energy Efficiency on Multicore X86 CPUs

Chip manufacturers introduce redundancy at various levels of CPU design to guarantee correct operation, even for worst-case combinations of non-idealities in process variation and system operating conditions. This redundancy is implemented partly in the form of voltage margins. However, for a wide range of real-world execution scenarios these margins are excessive and merely translate to increased power consumption, hindering the effort towards higher-energy efficiency in both HPC and general purpose computing. Our study on the x86-64 Haswell and Skylake multicore microarchitectures reveals-wide voltage margins, which vary across different microarchitectures, different chip parts of the same microarchitecture, and across different workloads. We find that it is necessary to quantify-voltage margins using multi-threaded and multi-instance workloads, as characterization with single-threaded and single-instance workloads that do not stress the CPU to its full capacity typically identifies overly optimistic margins that lead to errors when applied in realistic program execution scenarios. In addition, we introduce, deploy and evaluate a run-time governor that dynamically reduces the supply voltage of modern multicore x86-64 CPUs. Our governor employs a model that takes as input a set of performance metrics which are directly measurable via performance monitoring counters and have high predictive value for the minimum tolerable supply voltage (V min ), to predict and apply the appropriate reduction for the workload at hand. Compared with the conventional DVFS governor, our approach in this study achieves up to 42 percent energy savings for the Skylake family and 34 percent for the Haswell family for complex, real-world applications.

97 MATHEMATICS AND COMPUTING↗

Strategies to improve the mechanical robustness of metal halide perovskite solar cells

We report on the mechanical properties of high-efficiency perovskite solar cells (PSCs) with different chemical components by measuring the fracture energy (G c ) of films and devices. With the help of both macroscopic and microscopic techniques, we identify the locations where fracture takes place in the devices (either adhesive or cohesive failure) with various material and device structures. We propose strategies that can improve the fracture energy of PSCs based on the measured G c : the use of ozone-nucleated atomic layer deposition to improve charge transport layer robustness and the use of 2D perovskites and morphology control to improve the perovskite robustness. Our findings offer a pathway to rationally study the mechanical properties of PSCs and enable such cells to be more mechanically robust to reach commercial viability.

14 SOLAR ENERGY↗