Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Developing a Hybrid Electric Vehicle Eco-Cooperative Adaptive Cruise Control System at Signalized Intersections.

This study develops an eco-driving strategy for hybrid electric vehicles (HEVs) in the vicinity of signalized intersections, entitled HEV Eco-Cooperative Adaptive Cruise Control at Intersections (Eco-CACC-I). The proposed system computes real-time, energy-optimized vehicle trajectories using HEV vehicle dynamics and energy consumption models. In the proposed system, a simple HEV energy model is used to compute the instantaneous fuel consumption. This HEV energy model is selected since it is general, transferable, and can be easily used to compute instantaneous energy consumption levels for HEVs without the additional input of vehicle engine data or complicated power control strategies. In addition, a vehicle dynamics model is used to capture the relationship between speed, acceleration level, and tractive/resistance forces on vehicles. The energy-optimum problem is formulated as an optimization problem with constraints, which is solved using a moving-horizon dynamic programming approach. The proposed HEV Eco-CACC-I system was tested to evaluate its performance for various speed limits, roadway grades, and signal timings. Lastly, the proposed HEV controller was implemented in a microscopic traffic simulation software to test its network-wide performance. The test results from an arterial corridor with three signalized intersections demonstrate that the proposed system can effectively reduce stop-and-go traffic in the vicinity of signalized intersections producing savings of 7.4% in energy consumption, 5.8% in traffic delay and 23% vehicle stops, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Dashboards to Improve Energy and Comfort in Federal Buildings

Federal agencies are taking many steps to improve the sustainability of their operations, including improving the energy efficiency of their buildings, promoting recycling and reuse of materials, encouraging carpooling and alternative transit schemes, and installing low flow water fixture units are just a few of the common examples. However, an often overlooked means of energy savings is to provide feedback to building users about their energy use through information dashboards connected to a building?s energy information system. An Energy Information System (EIS), broadly defined, is a package of performance monitoring software, data acquisition hardware, and communication systems that is used to collect, store, analyze, and display energy information. At a minimum, the EIS provides the whole-building energy-use information (Granderson 2009a). We define a ?dashboard? as a display and visualization tool that utilizes the EIS data and technology to provide critical information to users. This information can lead to actions resulting in energy savings, comfort improvements, efficient operations, and more. The tools to report analyzed information have existed in the information technology as business intelligence (Few 2006). The dashboard is distinguished from the EIS as a whole, which includes additional hardware and software components to collect and storage data, and analysis for resources and energy management (Granderson 2009b). EIS can be used for a variety of uses, including benchmarking, base-lining, anomaly detection, off-hours energy use evaluation, load shape optimization, energy rate analysis, retrofit and retro-commissioning savings (Granderson 2009a). The use of these EIS features depends on the specific users. For example, federal and other building managers may use anomaly detection to identify energy waste in a specific building, or to benchmark energy use in similar buildings to identify energy saving potential and reduce operational cost. There are several vendors of EIS technology that provide information on energy and other environmental variables in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-I-77: A Noise Reduction Technique for Energy-Resolved Photon-Counting Detectors

Purpose: Finding the optimal energy threshold setting for an energy-resolved photon-counting detector has an important impact on the maximization of contrast-to-noise-ratio (CNR). We introduce a noise reduction method to enhance CNR by reducing the noise in each energy bin without altering the average gray levels in the projection and image domains. Methods: We simulated a four bin energy-resolved photon-counting detector based on Si with a 10 mm depth of interaction. TASMIP algorithm was used to simulate a spectrum of 65 kVp with 2.7 mm Al filter. A 13 mm PMMA phantom with hydroxyapatite and iodine at different concentrations (100, 200 and 300 mg/ml for HA, and 2, 4, and 8 mg/ml for Iodine) was used. Projection-based and Image-based energy weighting methods were used to generate weighted images. A reference low noise image was used for noise reduction purposes. A Gaussian-like weighting function which computes the similarity between pixels of interest was calculated from the reference image and implemented on a pixel by pixel basis for the noisy images. Results: CNR improvement compared to different methods (Charge-Integrated, Photon-Counting and Energy-Weighting) and after noise reduction was highly task-dependent. The CNR improvement with respect to the Charge-Integrated CNR for hydroxyapatite and iodine were 1.8 and 1.5, respectively. In each of the energy bins, the noise was reduced by approximately factor of two without altering their respective average gray levels. Conclusion: The proposed noise reduction technique for energy-resolved photon-counting detectors can significantly reduce image noise. This technique can be used as a compliment to the current energy-weighting methods in CNR optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REopt® [SWR-12-19]

The REopt® techno-economic decision support platform is used by NREL researchers to optimize energy systems for buildings, campuses, communities, microgrids, and more. REopt recommends the optimal mix of renewable energy, conventional generation, and energy storage technologies to meet cost savings, resilience, emissions reductions, and energy performance goals. The REopt® model provides concurrent, multiple technology integration and optimization capabilities to help organizations meet their cost savings and energy performance goals. Formulated as a mixed integer linear program, the REopt model recommends an optimally sized mix of renewable energy, conventional generation, and energy storage technologies; estimates the net present value of implementing those technologies; and provides a dispatch strategy for operating the technology mix at maximum economic efficiency. The REopt model was initially created to identify and prioritize cost-effective renewable energy projects across a portfolio of sites. The model is now also used to optimize the size and operating strategy of microgrids, storage, and energy/water systems.

Walker, Andy↗

DEVELOPING A TRAFFIC SIGNAL ECO-COOPERATIVE ADAPTIVE CRUISE CONTROL SYSTEM FOR BATTERY ELECTRIC VEHICLES

This study developed an eco-driving strategy for battery electric vehicles (BEVs) in the vicinity of signalized intersections, known as BEV Eco-Cooperative Adaptive Cruise Control at Intersections (Eco-CACC-I). The system computes a real-time, energy-optimized vehicle trajectory using a BEV vehicle dynamics and energy consumption model. In the proposed approach, the relationship between vehicle speed, acceleration level, and tractive/resistance forces on the vehicle follows the vehicle dynamics model. The Virginia Tech Comprehensive Power-based Electric Vehicle Energy Consumption Model (VT-CPEM) is used to compute the instantaneous battery energy consumption, with the consideration of battery energy regeneration during braking. The Eco-CACC-I energy-optimum trajectory computation is formulated as an optimization problem with constraints. Considering that the optimization solution needs to be computed at a rapid frequency (e.g., 10 Hz) for real-time applications, an A-star algorithm was used here to expedite the computational speed. Lastly, the proposed BEV Eco-CACC-I system was tested in simulation by considering the impacts of various road grades, speed limits, and signal timings. Simulations for an Internal Combustion Engine Vehicles (ICEVs) was conducted to compare with the BEV test results. The results of the comparison indicate that the energy-optimum solution for BEVs is different from that for ICEVs and thus demonstrating the need for vehicle-tailored optimum trajectories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cognitive barriers during monitoring-based commissioning of buildings

Monitoring-based commissioning (MBCx) is a continuous building energy management process used to optimize energy performance in buildings. Although monitoring-based commissioning (MBCx) can reduce energy waste by up to 20%, many buildings still underperform due to issues such as unnoticed system faults and inefficient operational procedures. While there are technical barriers that impede the MBCx process, such as data quality, the focuses of this paper are the non-technical, behavioral and organizational, barriers that contribute to issues initiating and implementing MBCx. In particular, this paper discusses cognitive biases, which can lead to suboptimal outcomes in energy efficiency decisions, resulting in missed opportunities for energy savings. This paper provides evidence of cognitive biases in decisions during the MBCx process using qualitative data from over 40 public and private sector organizations. The results describe barriers resulting from cognitive biases, listed in descending order of occurrence, including: risk aversion, social norms, choice overload, status quo bias, information overload, professional bias, and temporal discounting. Building practitioners can use these results to better understand potential cognitive biases, in turn allowing them to establish best practices and make more informed decisions. Finally, researchers can use these results to empirically test specific decision interventions and facilitate more energy efficient decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aerosol Envelope Sealing of Existing Residences

This report explores the best methods for aerosol envelope sealing of unoccupied, existing residences and documents typical leakage reductions. The project consisted of three distinct efforts: (1) scaled field demonstrations of the sealing process, tracking from setup to sealing and cleanup, (2) laboratory testing of new sealants that dry clear, making them more appropriate for retrofit applications, and (3) BEopt™ (Building Energy Optimization Tool) modeling of the energy implications of the measured reductions in leakage. Overall, aerosol sealing performance in existing homes was effective, with an average leakage reduction of 47% across all 34 sites. Conventional approaches typically only produce leakage reductions of 25%–30%. The aerosol sealing technology could provide a process for existing homes and multifamily units to gain the benefits of a well-sealed home at a reasonable cost with minimal disruption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling technological change and its impact on energy savings in the U.S. iron and steel sector

We report market penetration of energy-efficient technologies can be estimated using energy optimization models that minimize cost; however, such models typically estimate the minimum cost of optimal pathways under a certain set of non-dynamic assumptions, so technology penetrations determined for the long-term do not fully respond to changing circumstances or costs. Here, investment costs of energy-efficient technologies are modeled dynamically in the Industrial Sector Energy-Efficiency Model (ISEEM) using a technological learning formula. Results from 24 energy-efficient technologies – 14 existing, 10 emerging – selected from the United States (U.S.) iron and steel sector show that when technological learning is incorporated into the model, total energy consumption of this sector is expected to decrease by 13% (180 PJ) in 2050 compared to energy consumption in a non-learning scenario. Average energy intensity of the steel production improves from 12.3 GJ/t in the non-learning scenario to 10.7 GJ/t in the learning scenario in 2050. This decrease represents a cost savings of US $1.6 billion and a carbon dioxide emissions reduction potential of 14.9 billion tonnes. In conclusion, results discussed in this paper focus on the U.S. iron and steel sector, but the proposed framework can be applied to study new technology development in any other industrial processes and regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waste Not, Want Not: Analyzing the Economic and Environmental Viability of Waste-to-Energy (WTE) Technology for Site-Specific Optimization of Renewable Energy Options

Waste-to-energy (WTE) technology burns municipal solid waste (MSW) in an environmentally safe combustion system to generate electricity, provide district heat, and reduce the need for landfill disposal. While this technology has gained acceptance in Europe, it has yet to be commonly recognized as an option in the United States. Section 1 of this report provides an overview of WTE as a renewable energy technology and describes a high-level model developed to assess the feasibility of WTE at a site. Section 2 reviews results from previous life cycle assessment (LCA) studies of WTE, and then uses an LCA inventory tool to perform a screening-level analysis of cost, net energy production, greenhouse gas (GHG) emissions, and conventional air pollution impacts of WTE for residual MSW in Boulder, Colorado. Section 3 of this report describes the federal regulations that govern the permitting, monitoring, and operating practices of MSW combustors and provides emissions limits for WTE projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Dispatch Controller for Fuel Cell-Integrated Building: Preprint

Stationary fuel cells can generate both electrical power and heat, making it them a promising local source to serve building loads. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal in the building to lower reduce its operating cost and allows the building to participate in providing grid services. The proposed controller is tested in a co-simulation setup, where the real building is represented as a high-fidelity model in EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control-based Optimal Coordination of Distributed Energy Resources

Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive control (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.

Mayhorn, Ebony T.↗

Spectral anomaly methods for aerial detection using KUT nuisance rejection

Aerial detection combines all the challenges of standoff detection with all the difficulties of mobile survey, including large and varying standoff distances and abrupt and significant changes in background. Critical issues for aerial detection include land-water interfaces, rapidly changing KUT backgrounds, and varying down scatter with altitude changes. To address these issues a spectral anomaly method has been adapted to aerial detection. The NSCRAD (Nuisance-Rejection Spectral Comparison Ratio) algorithm was initially developed at PNNL for medium resolution detectors. The algorithm has been used for a range of ground-based detection applications, including ground-based detection, portal monitoring, and OSI applications. The method used in NSCRAD includes both optimized energy windows for detection of threat sources and a nuisance rejection capability. Additionally, the spectral anomaly method was optimized in this work for aerial detection systems to increase the probability of detection of threat sources in aerial search while using the nuisance rejection capability to minimize false alarms from rapidly changing aerial background. The adaptation of NSCRAD for aerial detection includes re-optimization of energy windows, adapting KUT nuisance rejection for aerial backgrounds, development of new methods for background tracking and adjustment of tracking and detection thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REopt: Energy Decision Analysis

The REopt techno-economic decision support platform is used by researchers to optimize energy systems for buildings, campuses, communities, microgrids, and more. REopt recommends the optimal mix of renewable energy, conventional generation, and energy storage technologies to meet cost savings, resilience, emissions reductions, and energy performance goals.

battery↗

Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IW n ). The advanced control program was then installed in the IW n control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building occupants and the building operator. Lifecycle cost analyses of the advanced building control were performed, and a Building Control System Guide was prepared and published to inform owners, architects, and engineers dealing with new construction or renovation of buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LDRD HPC4Energy Wrapup Report - LDRD 12-ERD-074

High-performance computing and simulation has the potential to optimize production, distribution, and conversion of energy. Although a number of concepts have been discussed, a comprehensive research project to establish and quantify the effectiveness of computing and simulation at scale to core energy problems has not been conducted. We propose to perform the basic research to adapt existing high-performance computing tools and simulation approaches to two selected classes of problems common across the energy sector. The first, applying uncertainty quantification and contingency analysis techniques to energy optimization, allows us to assess the effectiveness of LLNL core competencies to problems such as grid optimization and building-system efficiency. The second, applying adaptive meshing and numerical analysis techniques to physical problems at fine scale, could allow immediate impacts in key areas such as efficient combustion and fracture and spallation. By creating an integrated project team with the necessary expertise, we can efficiently address these issues, delivering both near-term results as well as quantifying developments needed to address future energy challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bias Correction in Urban Building Energy Modeling for Chicago Using Machine Learning

Urban-scale building energy modeling (UBEM) holds promise for optimizing energy usage across extensive geographic regions. However, there is a recognized bias between simulated energy consumption and actual measured data. This study, based on building data from Chicago, delved into bias correction techniques for enhancing the accuracy of UBEM energy consumption estimates. Initially, the AutoBEM simulation yielded a normalized mean bias error (NMBE) of 1.1% and 51% of Coefficient of the Variation of the Root Mean Square Error (CVRMSE) after outlier exclusion. To address this, three bias correction methods were deployed: Average Mean Bias Error based bias correction, Quantile mapping bias correction, and Machine learning-based bias correction using Linear Regression and Random Forest models. Post-correction results exhibited marked improvement. The NMBE values were diminished to 0 for Average MBE-based, 0.36 for Quantile Mapping, and 0 for Machine Learning-based corrections. Concurrently, the CVRMSE values registered reductions from an original 51 to 50.8 for Quantile Mapping, and 38.56 for Machine Learning-based corrections, pointing towards the effectiveness of specific bias correction methods in refining the precision of UBEM energy predictions. Such accurate estimations are paramount for informed energy planning and urban policy-making.

Chowdhury, Shovan↗

TAS: 89 0227: TAS Recovery Act - Optimization and Control of Electric Power Systems: ARRA

The name SuperOPF is used to refer several projects, problem formulations and soft-ware tools intended to extend, improve and re-define some of the standard methods of optimizing electric power systems. Our work included applying primal-dual interior point methods to standard AC optimal power flow problems of large size, as well as extensions of this problem to include co-optimization of multiple scenarios. The original SuperOPF problem formulation was based on co-optimizing a base scenario along with multiple post-contingency scenarios, where all AC power flow models and constraints are enforced for each, to find optimal energy contracts, endogenously determined locational reserves and appropriate nodal energy prices for a single period optimal power flow problem with uncertainty. This led to example non-linear programming problems on the order of 1 million constraints and half a million variables. The second generation SuperOPF formulation extends this by adding multiple periods and multiple base scenarios per period. It also incorporates additional variables and constraints to model load following reserves, ramping costs, and storage resources. A third generation of the multi-period SuperOPF, adds both integer variables and a receding horizon framework in which the problem type is more challenging (mixed integer), the size is even larger, and it must be solved more frequently, pushing the limits of currently available algorithms and solvers. The consideration of transient stability constraints in optimal power flow (OPF) problems has become increasingly important in modern power systems. Transient stability constrained OPF (TSCOPF) is a nonlinear optimization problem subject to a set of algebraic and differential equations. Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability in OPF. To handle the dynamics in TSCOPF, the set of differential equations can be approximated or converted into equivalent algebraic equations before they are included in an OPF formulation. In Chapter 4, a rigorous evaluation of using a predefined and fixed threshold for rotor angles as a mean to determine transient stability of the system is developed. TSCOPF can be modeled as a large-scale nonlinear programming problem including the constraints of differential-algebraic equations (DAE). Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability constraint in OPF. Unfortunately, even the current best TSCOPF solvers still suffer from the curse of dimensionality and unacceptable computational time, especially for large-scale power systems with multiple contingencies. In chapter 5, thse issues will be addressed and a new method to incorporate the transient stability constraints will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗