Search NASA⌕ Search

SEARCH · Search NASA

Results for “error bars”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Panel report: nuclear physics

Nuclear science is at the very heart of the NNSA program. The energy produced by nuclear processes is central to the NNSA mission, and nuclear reactions are critical in many applications, including National Ignition Facility (NIF) capsules, energy production, weapons, and in global threat reduction. Nuclear reactions are the source of energy in all these applications, and they can also be crucial in understanding and diagnosing the complex high-energy environments integral to the work of the NNSA. Nuclear processes are complex quantum many-body problems. Modeling and simulation of nuclear reactions and their role in applications, coupled tightly with experiments, have played a key role in NNSA's mission. The science input to NNSA program applications has been heavily reliant on experiment combined with extrapolations and physical models 'just good enough' to provide a starting point to extensive engineering that generated a body of empirical information. This body of information lacks the basic science underpinnings necessary to provide reliable extrapolations beyond the domain in which it was produced and for providing quantifiable error bars. Further, the ability to perform additional engineering tests is no longer possible, especially those tests that produce data in the extreme environments that uniquely characterize these applications. The end of testing has required improvements to the predictive capabilities of codes simulating the reactions and associated applications for both well known and well characterized cases as well as incompletely known cases. Developments in high performance computing, computational physics, applied mathematics and nuclear theory have combined to make spectacular advances in the theory of fission, fusion and nuclear reactions. Current research exploits these developments in a number of Office of Science and NNSA programs, and in joint programs such as the SciDAC (Science Discovery through Advanced Computing) that supports the project Building a Universal Nuclear Energy Density Fuctional whose goals are to provide the unified approach to calculating the properties of nuclei. The successful outcome of this, and similar projects is a first steps toward a predictive nuclear theory based on fundamental interactions between constituent nucleons. The application of this theory to the domain of nuclei important for national security missions will require computational resources at the extreme scale, beyond what will be available in the near term future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constant Overhead Entanglement Distillation via Scrambling

High-fidelity quantum entanglement enables key quantum networking capabilities such as secure communication and distributed quantum computing, but long-distance entanglement distribution is limited by noise and loss. Entanglement distillation protocols address this problem by extracting high-fidelity Bell pairs from multiple noisy ones. The primary objective is minimizing the resource overhead: the number of noisy input pairs needed to distill each high-fidelity output pair. While protocols achieving optimal overhead are known in theory, they often require complex decoding operations that make practical implementation challenging. We circumvent this challenge by introducing protocols that use quantum scrambling—the spreading of quantum information under chaotic dynamics—through random Clifford operations. Based on this scrambling mechanism, our protocol maintains asymptotically constant overhead, independent of the desired output error rate $\bar{𝜖}$ , and can be implemented with shallow quantum circuits of depth 𝑂⁡(poly log log⁡ $\bar{𝜖}$ −1 ) and memory 𝑂⁡(poly log⁡ $\bar{𝜖}$ −1 ). Our protocol remains effective even with noisy quantum gates. By incorporating error correction, our protocol achieves state-of-the-art performance: starting with pairs of 10% initial infidelity, we require only seven noisy inputs per output pair to distill a single Bell pair with infidelity $\bar{𝜖}$ =10 −12 , substantially outperforming existing schemes. We demonstrate the utility of our protocols for quantum repeater networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphically Contracted Function Construction with the Recursive Pairwise Merge Algorithm

A new implementation of a recursive pairwise merge algorithm to construct a GCF from a list of CSF expansion coefficients is presented. The essential new feature is the preallocation of some work arrays used within the intermediate steps of the merge procedure. This results in roughly an order of magnitude improvement in overall efficiency and also approximately eliminates a factor of n, the molecular orbital dimension, from the original implementation. Initial application of this merge procedure to a series of H m molecules shows that the GCF wave functions can be represented well both with delocalized canonical Hartree-Fock orbitals and with localized molecular orbitals. Finally, for a given wave function complexity, as measured by the average facet count, $\bar{\text {f}}$, the delocalized Hartree-Fock orbitals show smaller errors for small $\bar{\text {f}}$ values, while the localized orbitals show smaller errors for larger $\bar{\text {f}}$ values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement uncertainty of rossi-alpha neutron experiments

Rossi-alpha neutron experiments are used to estimate the prompt neutron decay constant of a fissile assembly, a quantity of widespread interest in applications including in nuclear nonproliferation and criticality safety. This work develops a mathematical model to efficiently estimate measurement uncertainty of Rossi-alpha neutron experiments inferred from a two-exponential fit model with histogram binning. The derived uncertainty estimates were validated using repeated Rossi-alpha measurements of a subcritical, 4.5-kg sphere of weapons-grade, alpha-phase plutonium with nickel, copper, tungsten, and polyethylene reflectors. The estimates of uncertainty for the histogram data produced by the model were conservative and agree with the reference uncertainties within noise. The estimates of the prompt neutron decay constant uncertainty agreed with the reference uncertainties within one standard deviation. In conclusion, the proposed model will reduce total measurement times, ultimately reducing operational and procedural costs in application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shock tube and theoretical studies on the thermal decomposition of propane : evidence for a roaming radical channel.

The thermal decomposition of propane has been studied using both shock tube experiments and ab initio transition state theory-based master equation calculations. Dissociation rate constants for propane have been measured at high temperatures behind reflected shock waves using high-sensitivity H-ARAS detection and CH{sub 3} optical absorption. The two major dissociation channels at high temperature are C{sub 3}H{sub 8} {yields} CH{sub 3} + C{sub 2}H{sub 5} (eq 1a) and C{sub 3}H{sub 8} {yields} CH{sub 4} + C{sub 2}H{sub 4} (eq 1b). Ultra high-sensitivity ARAS detection of H-atoms produced from the decomposition of the product, C{sub 2}H{sub 5}, in (1a), allowed measurements of both the total decomposition rate constants, k{sub total}, and the branching to radical products, k{sub 1a}/k{sub total}. Theoretical analyses indicate that the molecular products are formed exclusively through the roaming radical mechanism and that radical products are formed exclusively through channel 1a. The experiments were performed over the temperature range 1417-1819 K and gave a minor contribution of (10 {+-} 8%) due to roaming. A multipass CH{sub 3} absorption diagnostic using a Zn resonance lamp was also developed and characterized in this work using the thermal decomposition of CH{sub 3}I as a reference reaction. The measured rate constants for CH{sub 3}I decomposition agreed with earlier determinations from this laboratory that were based on I-atom ARAS measurements. This CH{sub 3} diagnostic was then used to detect radicals from channel 1a allowing lower temperature (1202-1543 K) measurements of k1a to be determined. Variable reaction coordinate-transition state theory was used to predict the high pressure limits for channel (1a) and other bond fission reactions in C{sub 3}H{sub 8}. Conventional transition state theory calculations were also used to estimate rate constants for other tight transition state processes. These calculations predict a negligible contribution (<1%) from all other bond fission and tight transition state processes, indicating that the bond fission channel (1a) and the roaming channel (1b) are indeed the only active channels at the temperature and pressure ranges of the present experiments. The predicted reaction exo- and endothermicities are in excellent agreement with the current version of the Active Thermochemical Tables. Master equation calculations incorporating these transition state theory results yield predictions for the temperature and pressure dependence of the dissociation rate constants for channel 1a. The final theoretical results reliably reproduce the measured dissociation rate constants that are reported here and in the literature. The experimental data are well reproduced over the 500-2500 K and 1 x 10{sup -4} to 100 bar range (errors of {approx}15% or less) by the following Troe parameters for Ar as the bath gas: k{sub {infinity}} = 1.55 x 10{sup 24}T{sup -2.034} exp(-45490/T) s{sup -1}, k{sub 0} = 7.92 x 10{sup 53}T{sup -16.67} exp(-50380/T) cm{sup 3} s{sup -1}, and F{sub c} = 0.190 exp(-T/3091) + 0.810 exp(-T/128) + exp(-8829/T).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Muon Antineutrino Disappearance in the MINOS Experiment

Antineutrinos from the set of 7.09$\times 10^{20}$ Protons-on-target (POT) of $\nu_\mu\textrm{-dominant}$ and 3.40$\times 10^{20}$ POT of $\bar\nu_\mu\textrm{-enhanced}$ MINOS beam data is analysed to extract the antineutrino atmospheric-scale oscillation parameters $\left|\Delta\bar m^2\right|$ and $\sin^2\left(2\bar\theta\right)$. Using the Feldman-Cousins statistical technique to account for systematic and statistical errors, $\left|\Delta\bar m^2\right|=2.58^{+0.26}_{-0.17} \times 10^{-3}~\textrm{eV}^2$ and $\sin^2\left(2\bar\theta\right)=0.96^{+0.04}_{-0.10}$ were measured. This measurement of $\left|\Delta\bar m^2\right|$ improves on the previous world limits from Super-K by a factor of five. Any observed difference between the neutrino and antineutrino oscillation parameters could be an indication of CPT violation, or otherwise physics beyond the standard model. This measurement is consistent with the global limits on $\left|\Delta m^2\right|$ and $\sin^2\left(2\theta\right)$ for neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SEDS: THE SPITZER EXTENDED DEEP SURVEY. SURVEY DESIGN, PHOTOMETRY, AND DEEP IRAC SOURCE COUNTS

The Spitzer Extended Deep Survey (SEDS) is a very deep infrared survey within five well-known extragalactic science fields: the UKIDSS Ultra-Deep Survey, the Extended Chandra Deep Field South, COSMOS, the Hubble Deep Field North, and the Extended Groth Strip. SEDS covers a total area of 1.46 deg{sup 2} to a depth of 26 AB mag (3{sigma}) in both of the warm Infrared Array Camera (IRAC) bands at 3.6 and 4.5 {mu}m. Because of its uniform depth of coverage in so many widely-separated fields, SEDS is subject to roughly 25% smaller errors due to cosmic variance than a single-field survey of the same size. SEDS was designed to detect and characterize galaxies from intermediate to high redshifts (z = 2-7) with a built-in means of assessing the impact of cosmic variance on the individual fields. Because the full SEDS depth was accumulated in at least three separate visits to each field, typically with six-month intervals between visits, SEDS also furnishes an opportunity to assess the infrared variability of faint objects. This paper describes the SEDS survey design, processing, and publicly-available data products. Deep IRAC counts for the more than 300,000 galaxies detected by SEDS are consistent with models based on known galaxy populations. Discrete IRAC sources contribute 5.6 {+-} 1.0 and 4.4 {+-} 0.8 nW m{sup -2} sr{sup -1} at 3.6 and 4.5 {mu}m to the diffuse cosmic infrared background (CIB). IRAC sources cannot contribute more than half of the total CIB flux estimated from DIRBE data. Barring an unexpected error in the DIRBE flux estimates, half the CIB flux must therefore come from a diffuse component.

79 ASTRONOMY AND ASTROPHYSICS↗

Testable dark energy predictions from current data

Given a class of dark energy models, constraints from one set of cosmic acceleration observables make predictions for other observables. Here we present the allowed ranges for the expansion rate H(z), distances D(z), and the linear growth function G(z) (as well as other, derived growth observables) from the current combination of cosmological measurements of supernovae, the cosmic microwave background, baryon acoustic oscillations, and the Hubble constant. With a cosmological constant as the dark energy and assuming near-minimal neutrino masses, the growth function is already predicted to better than 2% precision at any redshift, with or without spatial curvature. Direct measurements of growth that match this precision offer the opportunity to stringently test and potentially rule out a cosmological constant. While predictions in the broader class of quintessence models are weaker, it is remarkable that they are typically only a factor of 2-3 less precise than forecasted predictions for future space-based supernovae and Planck CMB measurements. In particular, measurements of growth at any redshift, or the Hubble constant H{sub 0}, that exceed {Lambda}CDM predictions by substantially more than 2% would rule out not only a cosmological constant but also the whole quintessence class, with or without curvature and early dark energy. Barring additional systematic errors hiding in the data, such a discovery would require more exotic explanations of cosmic acceleration such as phantom dark energy, dark energy clustering, or modifications of gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Evaluation of Monte Carlo Simulations of Neutron Multiplicity Measurements of Plutonium Metal

In January 2009, Sandia National Laboratories conducted neutron multiplicity measurements of a polyethylene-reflected plutonium metal sphere. Over the past 3 years, those experiments have been collaboratively analyzed using Monte Carlo simulations conducted by University of Michigan (UM), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), and North Carolina State University (NCSU). Monte Carlo simulations of the experiments consistently overpredict the mean and variance of the measured neutron multiplicity distribution. This paper presents a sensitivity study conducted to evaluate the potential sources of the observed errors. MCNPX-PoliMi simulations of plutonium neutron multiplicity measurements exhibited systematic over-prediction of the neutron multiplicity distribution. The over-prediction tended to increase with increasing multiplication. MCNPX-PoliMi had previously been validated against only very low multiplication benchmarks. We conducted sensitivity studies to try to identify the cause(s) of the simulation errors; we eliminated the potential causes we identified, except for Pu-239 {bar {nu}}. A very small change (-1.1%) in the Pu-239 {bar {nu}} dramatically improved the accuracy of the MCNPX-PoliMi simulation for all 6 measurements. This observation is consistent with the trend observed in the bias exhibited by the MCNPX-PoliMi simulations: a very small error in {bar {nu}} is 'magnified' by increasing multiplication. We applied a scalar adjustment to Pu-239 {bar {nu}} (independent of neutron energy); an adjustment that depends on energy is probably more appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-192: A Quick and Effective Method to Validate Patient’s Daily Setup and Geometry Changes Prior to Proton Treatment Delivery Based On Water Equivalent Thickness Projection Imaging (WETPI) for Head Neck Cancer (HNC) Patient

Purpose: With the implementation of Cone-beam Computed-Tomography (CBCT) in proton treatment, we introduces a quick and effective tool to verify the patient’s daily setup and geometry changes based on the Water-Equivalent-Thickness Projection-Image(WETPI) from individual beam angle. Methods: A bilateral head neck cancer(HNC) patient previously treated via VMAT was used in this study. The patient received 35 daily CBCT during the whole treatment and there is no significant weight change. The CT numbers of daily CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration(DIR). IMPT plan was generated using 4-field IMPT robust optimization (3.5% range and 3mm setup uncertainties) with beam angle 60, 135, 300, 225 degree. WETPI within CTV through all beam directions were calculated. 3%/3mm gamma index(GI) were used to provide a quantitative comparison between initial sim-CT and mapped daily CBCT. To simulate an extreme case where human error is involved, a couch bar was manually inserted in front of beam angle 225 degree of one CBCT. WETPI was compared in this scenario. Results: The average of GI passing rate of this patient from different beam angles throughout the treatment course is 91.5 ± 8.6. In the cases with low passing rate, it was found that the difference between shoulder and neck angle as well as the head rest often causes major deviation. This indicates that the most challenge in treating HNC is the setup around neck area. In the extreme case where a couch bar is accidently inserted in the beam line, GI passing rate drops to 52 from 95. Conclusion: WETPI and quantitative gamma analysis give clinicians, therapists and physicists a quick feedback of the patient’s setup accuracy or geometry changes. The tool could effectively avoid some human errors. Furthermore, this tool could be used potentially as an initial signal to trigger plan adaptation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-65: Prediction of Patient Setup Errors and Errors in the Calibration Curve from Prompt Gamma Proton Range Measurements

Purpose: To understand the extent to which the prompt gamma camera measurements can be used to predict the residual proton range due to setup errors and errors in the calibration curve. Methods: We generated ten variations on a default calibration curve (CC) and ten corresponding range maps (RM). Starting with the default RM, we chose a square array of N beamlets, which were then rotated by a random angle θ and shifted by a random vector s. We added a 5% distal Gaussian noise to each beamlet in order to introduce discrepancies that exist between the ranges predicted from the prompt gamma measurements and those simulated with Monte Carlo algorithms. For each RM, s, θ, along with an offset u in the CC, were optimized using a simple Euclidian distance between the default ranges and the ranges produced by the given RM. Results: The application of our method lead to the maximal overrange of 2.0mm and underrange of 0.6mm on average. Compared to the situations where s, θ, and u were ignored, these values were larger: 2.1mm and 4.3mm. In order to quantify the need for setup error corrections, we also performed computations in which u was corrected for, but s and θ were not. This yielded: 3.2mm and 3.2mm. The average computation time for 170 beamlets was 65 seconds. Conclusion: These results emphasize the necessity to correct for setup errors and the errors in the calibration curve. The simplicity and speed of our method makes it a good candidate for being implemented as a tool for in-room adaptive therapy. This work also demonstrates that the Prompt gamma range measurements can indeed be useful in the effort to reduce range errors. Given these results, and barring further refinements, this approach is a promising step towards an adaptive proton radiotherapy.

60 APPLIED LIFE SCIENCES↗

Testing CPT conservation using the NuMI neutrino beam with the MINOS experiment

The MINOS experiment was designed to measure neutrino oscillation parameters with muon neutrinos. It achieves this by measuring the neutrino energy spectrum and flavor composition of the man-made NuMI neutrino beam 1km after the beam is formed and again after 735 km. By comparing the two spectra it is possible to measure the oscillation parameters. The NuMI beam is made up of 7.0%$\bar{v}$ μ , which can be separated from the v μ because the MINOS detectors are magnetized. This makes it possible to study $\bar{v}$ μ oscillations separately from those of muon neutrinos, and thereby test CPT invariance in the neutrino sector by determining the $\bar{v}$ μ oscillation parameters and comparing them with those for v μ , although any unknown physics of the antineutrino would appear as a difference in oscillation parameters. Such a test has not been performed with beam $\bar{v}$ μ before. It is also possible to produce an almost pure $\bar{v}$ μ beam by reversing the current through the magnetic focusing horns of the NuMI beamline, thereby focusing negatively, instead of positively charged particles. This thesis describes the analysis of the 7% $\bar{v}$ μ component of the forward horn current NuMI beam. The $\bar{v}$ μ of a data sample of 3.2 x 10{sup 20} protons on target analysis found 42 events, compared to a CPT conserving prediction of 58.3 -7.6 +7.6 (stat.) -3.6 +3.6 (syst.) events. This corresponds to a 1.9 σ deficit, and a best fit value of Δ$\bar{m}$ 32 2 = 18 x 10 -3 eV 2 and sin 2 2$\bar{θ}$ 23 = 0.55. This thesis focuses particularly on the selection of $\bar{v}$ μ events, and investigates possible improvements of the selection algorithm. From this a different selector was chosen, which corroborated the findings of the original selector. The thesis also investigates how the systematic errors affect the precision of Δ$\bar{m}$ 32 2 and sin 2 2$\bar{θ}$ 23 . Furthermore, it describes a study to determine the gains of the PMTs via the single-photoelectron spectrum. The results were used as a crosscheck of the gains determined at higher intensities by an LED-based light-injection system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the Semileptonic Decays \Bb\to D\ell\nub and \Bb\to D^*\ell\nub Using a Global Fit to D X\ell\nub Final States

Semileptonic {bar B} decays to DX{ell}{bar {nu}} ({ell} = e or {mu}) are selected by reconstructing D{sup 0}{ell} and D{sup +}{ell} combinations from a sample of 230 million {Upsilon}(4S) {yields} B{bar B} decays recorded with the BABAR detector at the PEP-II e{sup +}e{sup -} collider at SLAC. A global fit to these samples in a 3-dimensional space of kinematic variables is used to determine the branching fractions {Beta}(B{sup -} {yields} D{sup 0}{ell}{bar {nu}}) = 2.36 {+-} 0.03 {+-} 0.12% and {Beta}(B{sup -} {yields} D*{sup 0}{ell}{bar {nu}}) = (5.37 {+-} 0.02 {+-} 0.21)% where the errors are statistical and systematic, respectively. The fit also determines form factor parameters in a HQET-based parameterization, resulting in {rho}{sub D}{sup 2} = 1.22 {+-} 0.04 {+-} 0.07 for {bar B} {yields} D{ell}{bar {nu}} and {rho}{sub D*}{sup 2} = 1.21 {+-} 0.02 {+-} 0.07 for {bar B} {yields} D*{ell}{bar {nu}}. These values are used to obtain the product of the CKM matrix element |V{sub cb}| times the form factor at the zero recoil point for both {bar B} {yields} D{ell}{bar {nu}} decays, G(1)|V{sub cb}| = (43.8 {+-} 0.8 {+-} 2.3) x 10{sup -3}, and for {bar B} {yields} D*{ell}{bar {nu}} decays, F(1)|V{sub cb}| = (35.7 {+-} 0.2 {+-} 1.2) x 10{sup -3}.

43 PARTICLE ACCELERATORS↗

A Correction Scheme for Thermal Conductivity Measurement Using the Comparative Cut-bar Technique Based on a 3D Numerical Simulation

As an important factor affecting the accuracy of the thermal conductivity measurement, systematic (bias) error in the guarded comparative axial heat flow (cut-bar) method was mostly neglected by previous researches. This bias is due primarily to the thermal conductivity mismatch between sample and meter bars (reference), which is common for a sample of unknown thermal conductivity. A correction scheme, based on a finite element simulation of the measurement system, was proposed to reduce the magnitude of the overall measurement uncertainty. This scheme was experimentally validated by applying corrections on four types of sample measurements in which the specimen thermal conductivity is much smaller, slightly smaller, equal and much larger than that of the meter bar. As an alternative to the optimum guarding technique proposed before, the correction scheme can be used to minimize uncertainty contribution from the measurement system with non-optimal guarding conditions. It is especially necessary for large thermal conductivity mismatches between sample and meter bars.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ON THE CURVATURE OF DUST LANES IN GALACTIC BARS

We test the theoretical prediction that the straightest dust lanes in bars are found in strongly barred galaxies, or more specifically, that the degree of curvature of the dust lanes is inversely proportional to the strength of the bar. The test uses archival images of barred galaxies for which a reliable nonaxisymmetric torque parameter (Q {sub b}) and the radius at which Q {sub b} has been measured (r(Q {sub b})) have been published in the literature. Our results confirm the theoretical prediction but show a large spread that cannot be accounted for by measurement errors. We simulate 238 galaxies with different bar and bulge parameters in order to investigate the origin of the spread in the dust lane curvature versus Q {sub b} relation. From these simulations, we conclude that the spread is greatly reduced when describing the bar strength as a linear combination of the bar parameters Q {sub b} and the quotient of the major and minor axes of the bar, a/b. Thus, we conclude that the dust lane curvature is predominantly determined by the parameters of the bar.

79 ASTRONOMY AND ASTROPHYSICS↗

An optimal guarding scheme for thermal conductivity measurement using a guarded cut-bar technique, part 1 experimental study

In the guarded cut-bar technique, a guard surrounding the measured sample and reference (meter) bars is temperature controlled to carefully regulate heat losses from the sample and reference bars. Guarding is typically carried out by matching the temperature profiles between the guard and the test stack of sample and meter bars. Problems arise in matching the profiles, especially when the thermal conductivitiesof the meter bars and of the sample differ, as is usually the case. In a previous numerical study, the applied guarding condition (guard temperature profile) was found to be an important factor in measurement accuracy. Different from the linear-matched or isothermal schemes recommended in literature, the optimal guarding condition is dependent on the system geometry and thermal conductivity ratio of sample to meter bar. To validate the numerical results, an experimental study was performed to investigate the resulting error under different guarding conditions using stainless steel 304 as both the sample and meter bars. The optimal guarding condition was further verified on a certified reference material, pyroceram 9606, and 99.95% pure iron whose thermal conductivities are much smaller and much larger, respectively, than that of the stainless steel meter bars. Additionally, measurements are performed using three different inert gases to show the effect of the insulation effective thermal conductivity on measurement error, revealing low conductivity, argon gas, gives the lowest error sensitivity when deviating from the optimal condition. The result of this study provides a general guideline for the specific measurement method and for methods requiring optimal guarding or insulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Wormholes Within: A Study of 1, 3, 5–Triamino–2, 4, 6–Trinitrobenzene Crystal Morphology by Micro and Nano–Scale X–Ray Computed Tomography and its Effects Upon the Shock Sensitivity of Detonation

We report that we understand heterogeneous-explosive detonation only to the extent that we can first measure the salient chemical and microstructural features. Barring an inordinate amount of trial and error, we can tailor the detonation properties of our HE formulations only to the extent that we understand (at least qualitatively) the same effects. As an insensitive high explosive, 1, 3, 5-triamino-2, 4, 6-trinitrobenzene (TATB) burns more heterogeneously than conventional high explosives, making its detonation properties sensitive to microstructure. The Benziger route can produce various grain morphologies depending on the amount of water used in the amination step. So-called dry-aminated (DA) TATB crystals are riddled with a void structure called wormholes, which are washed out ammonium chloride (NH4Cl) inclusions that form during synthesis. So-called wet-aminated (WA) TATB crystals do not contain NH 4 Cl inclusions but possess a very convoluted external structure. Using both micro and nano-scale CT, we explore three DA-TATB lots that reflect evolutionary processing changes, plus one WA-TATB material. Micro CT imaged crystal collections show the exterior grain structure, revealing its roughness and providing a crude particle size measurement. The DA-TATB lots that test most sensitively in the LANL ECOT corner-turning test are roughest, having the appearance of being “corroded”. Nano-scale CT reveals both internal NH 4 Cl inclusions and void structures. The DA-TATB lots that tested intermediate and high sensitivity in ECOT exhibited similar wormhole structures, which were more extensive than that of the low-sensitivity lot. The least sensitive DA-TATB lot also retained more NH 4 Cl, consistent with reduced connectivity of voids to the surface.

1, 3, 5-triamino-2,4↗