Search NASA⌕ Search

SEARCH · Search NASA

Results for “explosives detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Standoff imaging of chemicals using IR spectroscopy

Here we report on a standoff spectroscopic technique for identifying chemical residues on surfaces. A hand-held infrared camera was used in conjunction with a wavelength tunable mid-IR quantum cascade laser (QCL) to create hyperspectral image arrays of a target with an explosive residue on its surface. Spectral signatures of the explosive residue (RDX) were extracted from the hyperspectral image arrays and compared with a reference spectrum. Identification of RDX was achieved for residue concentrations of 20 g per cm2 at a distance of 1.5 m, and for 5 g per cm2 at a distance of 15 cm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IMPLEMENTING THE STANDARD SPECTRUM METHOD FOR ANALYSIS OF β-γ COINCIDENCE SPECTRA

The standard deconvolution analysis tool (SDAT) algorithms were developed and tested at the University of Texas at Austin. These algorithms utilize the standard spectrum technique for spectral analysis of {beta}-{gamma} coincidence spectra for nuclear explosion monitoring. Work has been conducted under this contract to implement these algorithms into a useable scientific software package with a graphical user interface. Improvements include the ability to read in PHD formatted data, gain matching, and data visualization. New auto-calibration algorithms were developed and implemented based on 137Cs spectra for assessment of the energy vs. channel calibrations. Details on the user tool and testing are included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

241Am (n,gamma) isomer ratio measurement

The objective of this project is to improve the accuracy of the {sup 242}Cm/{sup 241}Am radiochemistry ratio. We have performed an activation experiment to measure the {sup 241}Am(n,{gamma}) cross section leading to either the ground state of {sup 242g}Am (t{sub 1/2} = 16 hr) which decays to {sup 242}Cm (t{sub 1/2} = 163 d) or the long-lived isomer {sup 242m}Am (t{sub 1/2} = 141 yr). This experiment will develop a new set of americium cross section evaluations that can be used with a measured {sup 242}Cm/{sup 241}Am radiochemical measurement for nuclear forensic purposes. This measurement is necessary to interpret the {sup 242}Cm/{sup 241}Am ratio because a good measurement of this neutron capture isomer ratio for {sup 241}Am does not exist. The targets were prepared in 2007 from {sup 241}Am purified from LANL stocks. Gold was added to the purified {sup 241}Am as an internal neutron fluence monitor. These targets were placed into a holder, packaged, and shipped to Forschungszentrum Karlsruhe, where they were irradiated at their Van de Graff facility in February 2008. One target was irradiated with {approx}25 keV quasimonoenergetic neutrons produced by the {sup 7}Li(p,n) reaction for 3 days and a second target was also irradiated for 3 days with {approx}500 keV neutrons. Because it will be necessary to separate the {sup 242}Cm from the {sup 241}Am in order to measure the amount of {sup 242}Cm by alpha spectrometry, research into methods for americium/curium separations were conducted concurrently. We found that anion exchange chromatography in methanol/nitric acid solutions produced good separations that could be completed in one day resulting in a sample with no residue. The samples were returned from Germany in July 2009 and were counted by gamma spectrometry. Chemical separations have commenced on the blank sample. Each sample will be spiked with {sup 244}Cm, dissolved and digested in nitric acid solutions. One third of each sample will be processed at a time. First, the gold will be removed by anion exchange chromatography. Then the {sup 242}Cm will be separated from the {sup 241}Am using the methanol/nitric acid anion exchange method. When a sufficient separation has been achieved, a deposit will be prepared and the {sup 242}Cm will be counted by alpha spectrometry. The purified {sup 241}Am fraction containing the long lived {sup 242m}Am will be allowed to decay into {sup 242}Cm for a period of {approx}6 months. After this time, the americium/curium separations will be repeated and the {sup 242}Cm that has grown in will be counted by alpha spectrometry. At the conclusion of the experiment, we will have cross section measurements for {sup 241}Am (n,{gamma}) {sup 242g}Am and {sup 241}Am (n,V) {sup 242m}Am at two energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Method of multi-dimensional moment analysis for the characterization of signal peaks

A method of multi-dimensional moment analysis for the characterization of signal peaks can be used to optimize the operation of an analytical system. With a two-dimensional Peclet analysis, the quality and signal fidelity of peaks in a two-dimensional experimental space can be analyzed and scored. This method is particularly useful in determining optimum operational parameters for an analytical system which requires the automated analysis of large numbers of analyte data peaks. For example, the method can be used to optimize analytical systems including an ion mobility spectrometer that uses a temperature stepped desorption technique for the detection of explosive mixtures.

47 OTHER INSTRUMENTATION↗

Real time explosive hazard information sensing, processing, and communication for autonomous operation

Methods, computer readable media, and apparatuses provide robotic explosive hazard detection. A robot intelligence kernel (RIK) includes a dynamic autonomy structure with two or more autonomy levels between operator intervention and robot initiative A mine sensor and processing module (ESPM) operating separately from the RIK perceives environmental variables indicative of a mine using subsurface perceptors. The ESPM processes mine information to determine a likelihood of a presence of a mine. A robot can autonomously modify behavior responsive to an indication of a detected mine. The behavior is modified between detection of mines, detailed scanning and characterization of the mine, developing mine indication parameters, and resuming detection. Real time messages are passed between the RIK and the ESPM. A combination of ESPM bound messages and RIK bound messages cause the robot platform to switch between modes including a calibration mode, the mine detection mode, and the mine characterization mode.

97 MATHEMATICS AND COMPUTING↗

Real time explosive hazard information sensing, processing, and communication for autonomous operation

Methods, computer readable media, and apparatuses provide robotic explosive hazard detection. A robot intelligence kernel (RIK) includes a dynamic autonomy structure with two or more autonomy levels between operator intervention and robot initiative A mine sensor and processing module (ESPM) operating separately from the RIK perceives environmental variables indicative of a mine using subsurface perceptors. The ESPM processes mine information to determine a likelihood of a presence of a mine. A robot can autonomously modify behavior responsive to an indication of a detected mine. The behavior is modified between detection of mines, detailed scanning and characterization of the mine, developing mine indication parameters, and resuming detection. Real time messages are passed between the RIK and the ESPM. A combination of ESPM bound messages and RIK bound messages cause the robot platform to switch between modes including a calibration mode, the mine detection mode, and the mine characterization mode.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Defeat system for vehicle attached improvised explosive devices

An explosive device detection and expulsion system broadly comprising a detection subsystem for sensing an IED attached to a vehicle and an expulsion subsystem for expelling the IED from the vehicle. The detection subsystem includes a sensor for detecting an IED via an electromagnetic field change or capacitance change, vibrations, and/or heat, and a controller for activating the expulsion subsystem upon receiving a detection signal from the sensor. The expulsion subsystem includes a deployable panel configured to be attached to the vehicle and a deployable mechanism for shifting the deployable panel from an undeployed state to a deployed state so as to expel the IED from the vehicle.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Defeat system for vehicle attached improvised explosive devices

An explosive device detection and expulsion system broadly comprising a detection subsystem for sensing an IED attached to a vehicle and an expulsion subsystem for expelling the IED from the vehicle. The detection subsystem includes a sensor for detecting an IED via an electromagnetic field change or capacitance change, vibrations, and/or heat, and a controller for activating the expulsion subsystem upon receiving a detection signal from the sensor. The expulsion subsystem includes a deployable panel configured to be attached to the vehicle and a deployable mechanism for shifting the deployable panel from an undeployed state to a deployed state so as to expel the IED from the vehicle.

Hower, Brent↗

Event detection unit

An event detection unit (EDU) for detecting an explosive event is provided. The EDU includes different types of sensors for measuring characteristics of an explosive event. The EDU includes an event notification component. The EDU also includes a processor that receives a measurement from the sensors and generates a combined non-event probability and a combined event probability based on that measurement that indicates a likelihood that an explosive event has not occurred or has occurred. The processor determines whether an explosive event has occurred based on the non-event probabilities and event probabilities. When an explosive event has been determined to occur, the processor directs the event notification component to output a notification that an explosive event has occurred.

Candy, James Vincent↗

Event detection unit

An event detection unit (EDU) for detecting an explosive event is provided. The EDU includes different types of sensors for measuring characteristics of an explosive event. The EDU includes an event notification component. The EDU also includes a processor that receives a measurement from the sensors and generates a combined non-event probability and a combined event probability based on that measurement that indicates a likelihood that an explosive event has not occurred or has occurred. The processor determines whether an explosive event has occurred based on the non-event probabilities and event probabilities. When an explosive event has been determined to occur, the processor directs the event notification component to output a notification that an explosive event has occurred.

Candy, James Vincent↗

Single sample extraction and HPLC processing for quantification of NAD and NADH levels in Saccharomyces cerevisiae

A robust redox extraction protocol for quantitative and reproducible metabolite isolation and recovery has been developed for simultaneous measurement of nicotinamide adenine dinucleotide (NAD) and its reduced form, NADH, from Saccharomyces cerevisiae. Following culture in liquid media, approximately 10{sup 8} yeast cells were harvested by centrifugation and then lysed under non-oxidizing conditions by bead blasting in ice-cold, nitrogen-saturated 50-mM ammonium acetate. To enable protein denaturation, ice cold nitrogen-saturated CH{sub 3}CN + 50-mM ammonium acetate (3:1; v:v) was added to the cell lysates. After sample centrifugation to pellet precipitated proteins, organic solvent removal was performed on supernatants by chloroform extraction. The remaining aqueous phase was dried and resuspended in 50-mM ammonium acetate. NAD and NADH were separated by HPLC and quantified using UV-VIS absorbance detection. Applicability of this procedure for quantifying NAD and NADH levels was evaluated by culturing yeast under normal (2% glucose) and calorie restricted (0.5% glucose) conditions. NAD and NADH contents are similar to previously reported levels in yeast obtained using enzymatic assays performed separately on acid (for NAD) and alkali (for NADH) extracts. Results demonstrate that it is possible to perform a single preparation to reliably and robustly quantitate both NAD and NADH contents in the same sample. Robustness of the protocol suggests it will be (1) applicable to quantification of these metabolites in mammalian and bacterial cell cultures; and (2) amenable to isotope labeling strategies to determine the relative contribution of specific metabolic pathways to total NAD and NADH levels in cell cultures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Resonance Fluorescence Measurements of High Explosives

Pacific Northwest National Laboratory and Passport Systems have collaborated to perform Nuclear Resonance Fluorescence experiments using several high quality high-explosive simulant samples. These measurements were conducted to determine the feasibility of finding and characterizing high explosive material by NRF interrogation. Electron beams of 5.1, 5.3, 8, and 10 MeV were used to produce bremsstrahlung photon beams, which irradiated the samples. The gamma-ray spectra were collected using high-purity germanium detectors. Nitrogen-to-carbon ratios of the high-explosive simulants were extracted from the 5.1 and 5.3 MeV data and compare favorably with accepted values. Analysis of the 8 and 10 MeV data is in progress; preliminary isotopic comparisons within the samples are consistent with the expected results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High brightness--multiple beamlets source for patterned X-ray production

Techniques for controllably directing beamlets to a target substrate are disclosed. The beamlets may be either positive ions or electrons. It has been shown that beamlets may be produced with a diameter of 1 .mu.m, with inter-aperture spacings of 12 .mu.m. An array of such beamlets, may be used for maskless lithography. By step-wise movement of the beamlets relative to the target substrate, individual devices may be directly e-beam written. Ion beams may be directly written as well. Due to the high brightness of the beamlets from extraction from a multicusp source, exposure times for lithographic exposure are thought to be minimized. Alternatively, the beamlets may be electrons striking a high Z material for X-ray production, thereafter collimated to provide patterned X-ray exposures such as those used in CAT scans. Such a device may be used for remote detection of explosives.

47 OTHER INSTRUMENTATION↗