Houston, We Have a Problem—and a Solution: Solar Performance Initiative Helps Federal Building Boost Rooftop Production
Fact sheet describes evaluating and optimizing a PV system on the Mickey Leland Federal Building.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fact sheet describes evaluating and optimizing a PV system on the Mickey Leland Federal Building.
Recent high-impact events such as hurricanes and wildfires have resulted in the loss of utility grid power to federal sites, highlighting the need for energy system resilience. To sustain critical functions, site loads may need to operate during an electric grid outage or at least have power restored quickly after the event. A microgrid can provide reliable backup power to critical loads when electric utility power is interrupted, and may also provide value during normal operations.
Presentation provides an overview of federal carbon reduction policy; net-zero emission building, campus, and installation design; performance targets; and decarbonization strategies.
Provides an overview of the National Renewable Energy Laboratory (NREL) Customer Damage Function (CDF) Calculator web tool, developed with funding and support from the Federal Energy Management Program (FEMP). The CDF Calculator is a screening tool that provides justification to site and/or headquarters leadership for resilience investments. It generates monetary values to justify investments in resilience solutions to prevent or lessen the impact of a grid outage at a facility.
The Biden Administration's issuance of Executive Orders directly addressing and accelerating Federal fleet electrification places an onus on both fleet and facility managers. This panel will help fleet and facility personnel understand how to select EVSE infrastructure in terms of implementation, energy management, and costs of procurement, installation/deployment, and electricity. The panel will cover technology aspects to include managed EVSE, bi-directional charging, implications on local electrical systems and storage needs in certain cases to buffer power demand. Discussion will include various considerations relevant to ensuring adequate EVSE, balancing infrastructure needs, and upgrades with fleet needs. The panelists will discuss how to provide sufficient infrastructure support, including which stakeholders to involve, procurement impediments, easement locations, and requirements that arise during the design and implementation process.
The Federal Energy Management Program (FEMP) plays a key role in helping agencies understand and meet energy-related goals, including those surrounding smart buildings technologies and grid-interactive efficient buildings (GEBs), which can support decarbonization. GEB enables demand flexibility that has the potential to reduce electrical infrastructure costs and transform the grid edge, where buildings connect to the power grid.
This presentation provides and overview of the Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions (FAST-DERMS) project and progress to date as of December 2024.
This presentation provides an overview of NREL's Advanced Distribution Management System (ADMS) Test Bed Use Case 5: Federated DERMS for High PV Systems.
Floating photovoltaic generation is a rapidly expanding sector of the solar energy industry, and understanding the quantity that can feasibly be installed is a crucial step to understand its role in future energy systems. This paper presents a novel spatially explicit methology of FPV potential for federally owned and managed reservoirs in the United States that uses site-specific attributes of reservoirs to estimate available area and potential generation capacity. The analysis finds that the proportion reservoir area that is found to be available for FPV development is similar to assumed values used in previous research on average, however there is a wide variability in this proportion on a site by site basis. Potential FPV generation capacity on these reservoirs is estimated to be in the range of 861 to 1,042 GWdc depending on input assumptions, likely representing a significant portion of future US solar generation needs. This work represents an advancement in methods used to estimate FPV potential that presents many natural extensions for further research.
Federated learning (FL) is a distributed machine learning approach that enables multiple local clients and a central server to collaboratively train a model while keeping the data on their own devices. First-order methods, particularly those incorporating variance reduction techniques, are the most widely used FL algorithms due to their simple implementation and stable performance. However, these methods tend to be slow and require a large number of communication rounds to reach the global minimizer. We propose FedOSAA, a novel approach that preserves the simplicity of first-order methods while achieving the rapid convergence typically associated with second-order methods. Our approach applies one Anderson acceleration (AA) step following classical local updates based on first-order methods with variance reduction, such as FedSVRG and SCAFFOLD, during local training. This AA step is able to leverage curvature information from the history points and gives a new update that approximates the Newton-GMRES direction, thereby significantly improving the convergence. We establish a local linear convergence rate to the global minimizer of FedOSAA for smooth and strongly convex loss functions. Numerical comparisons show that FedOSAA substantially improves the communication and computation efficiency of the original first-order methods, achieving performance comparable to second-order methods like GIANT.
The growing convergence of Information Technology (IT) and Operational Technology (OT) within Industry 4.0 environments has introduced new demands on industrial network infrastructure. As cyber-physical systems become increasingly interconnected, ensuring the secure, timely, and efficient exchange of critical data is essential. This thesis explores how network slicing, a method of creating isolated virtual network segments, can be applied within OT environments to address challenges such as latency, security, and resource allocation. The first research question addressed in this thesis is: How can OT networks take advantage of NFV and SDN technology to become cyber resilient? This study examines the operational, security, and architectural implications of introducing network slicing into traditionally static OT infrastructures such as Industrial Control Systems (ICS) and SCADA. Through simulated deployments and case studies, the research demonstrates how slicing enables better isolation between critical and non-critical services, thereby improving response time, throughput, and security in sensitive environments. The second question considers: How to dynamically implement network slicing and take advantage of network resources towards integrating decentralized machine learning? In response, this thesis proposes a framework that combines Software-Defined Networking (SDN), Network Function Virtualization (NFV), and Federated Learning (FL) to enable real-time analytics while maintaining data locality. The proposed approach reduces the burden on centralized infrastructure and minimizes privacy risks by supporting on-site training of models across distributed OT nodes, coordinated through dynamically allocated network slices. The third focus explores: How slicing helps to increase the resiliency of OT networks through the orchestration of a dynamic DMZ? To answer this, the thesis presents a method for creating and managing Dynamic Demilitarized Zones (DMZs) using network slicing. This enables flexible and automated isolation of sensitive subsystems during threat scenarios or high-risk operations. Coupled with intelligent orchestration and containerized security services, the dynamic DMZ significantly enhances the system's ability to respond to cyber incidents without halting production. Ultimately, this thesis contributes a comprehensive architecture that blends network slicing with machine learning, secure segmentation, and automation, paving the way for resilient, adaptive, and intelligent OT environments. Performance evaluations across multiple scenarios show improvements in system reliability, threat response time, model accuracy, and resource utilization, providing a strong foundation for future industrial automation systems.
Due to the distributed nature of Federated Learning (FL) systems, each local client has access to the global model, which poses a critical risk of model leakage. Existing works have explored injecting watermarks into local models to enable intellectual property protection. However, these methods either focus on non-traceable watermarks or traceable but white-box watermarks. We identify a gap in the literature regarding the formal definition of traceable black-box watermarking and the formulation of the problem of injecting such watermarks into FL systems. In this work, we first formalize the problem of injecting traceable black-box watermarks into FL. Based on the problem, we propose a novel server-side watermarking method, TraMark, which creates a traceable watermarked model for each client, enabling verification of model leakage in black-box settings. To achieve this, TraMark partitions the model parameter space into two distinct regions: the main task region and the watermarking region. Subsequently, a personalized global model is constructed for each client by aggregating only the main task region while preserving the watermarking region. Each model then learns a unique watermark exclusively within the watermarking region using a distinct watermark dataset before being sent back to the local client. Extensive results across various FL systems demonstrate that TraMark ensures the traceability of all watermarked models while preserving their main task performance.
This is a poster for the INL Data centers workshop. It shows how power lines were identified as good candidates for reconductoring with advanced conductors to better connect data centers sited on federal lands.
Fact sheet provides an overview and actionable next steps in the microgrid implementation process.
Not Available
Not Available
This report helps agency fleet managers understand and implement optimal petroleum reduction strategies for fleet locations by evaluating the most appropriate combination of the four core principles of sustainable fleet management: right-sizing the fleet to agency mission by implementing a vehicle allocation methodology study; minimizing vehicle miles traveled; increasing fleet fuel efficiency by replacing inefficient vehicles with more fuel-efficient vehicles, maintaining vehicles, driving more efficiently, and avoiding excessive idling; and optimizing cost-effective alternative fuel use, including maximizing utilization of existing alternative fuel infrastructure, installing alternative fuel infrastructure where practical (including electric vehicle charging stations), and aligning deployment of alternative fuel vehicles with fueling infrastructure.
This document is designed to help agency fleet managers understand and implement optimal petroleum reduction strategies for each fleet location by evaluating the most appropriate combination of the four core principles of sustainable fleet management: Right-sizing the fleet to agency mission by implementing a vehicle allocation methodology study; Minimizing vehicle miles traveled; Increasing fleet fuel efficiency by replacing inefficient vehicles with more fuel-efficient vehicles, maintaining vehicles, driving more efficiently, and avoiding excessive idling; Optimizing cost-effective alternative fuel use, including maximizing utilization of existing alternative fuel infrastructure, installing alternative fuel infrastructure where practical (including electric vehicle charging stations), and aligning deployment of alternative fuel vehicles with fueling infrastructure.