Search NASA⌕ Search

SEARCH · Search NASA

Results for “filled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Light- and Elevated-Temperature-Induced Degradation-Affected Silicon Cells From a Utility-Scale Photovoltaic System Characterized by Deep-Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated-temperature-induced degradation (LeTID). Samples from the affected monocrystalline silicon cells are cored and extracted from the module packaging and then laser-scribed to form 2-mm diameter isolated areas. Using deep-level transient spectroscopy, a majority-carrier, hole-trap defect with an activation energy of 0.42 eV is detected on degraded and regenerated samples. The LeTID-degraded sample, however, has a larger signal corresponding to a trap density of 1.1 x 10 13 cm -3 , which is about five times larger than the 2.1 x 10 12 cm -3 trap density of the regenerated sample. An increase in filling pulse time from 50 u s to 20 ms shows a slight decrease in activation energy from 0.42 to 0.36 eV suggesting that the defect level may consist of a band of energy states where shallower states continue to fill with long filling times. The capture rate of the defect is directly measured using an increasing series of filling pulsewidths in 15 to 125 ns range. This leads to a measured capture cross section of 5.1 x 10 -17 cm 2 , and using an approximate defect density of 10 13 cm -3 , the majority-carrier-hole lifetime related to this defect is approximately 100 u s when in the LeTID-degraded state.

charge carrier lifetime↗

Top-Performing Photovoltaic Cells Compared to the Shockley–Queisser Limit

Top-performing single-junction and two-terminal tandem devices that include at least one polycrystalline cell are compared with each other and their ideal limits. The parameters of open-circuit voltage, short-circuit current, and fill-factor are individually compared to the Shockley–Queisser limit to investigate where different technologies have room to improve. Technologies, such as silicon and cadmium telluride have the most room for improvement in open-circuit voltage currently utilizing 87% and 81% of their maxima, respectively. Detailed diode and fill-factor loss analysis is presented for single-junction devices to give further insight on how they compare and where efficiency is lost. Single-crystal technologies demonstrate a fill-factor closer to the Shockley–Queisser limit than polycrystalline devices. The high diode quality factor of polycrystalline devices is the leading cause of the decreased fill-factor. Similar analysis on tandem cells with at least one thin-film cell shows that although their efficiency exceeds that of the single-junction cells, the fraction of their ideal efficiency is smaller. Here, by comparing parameters to the Shockley–Queisser limit, it becomes clearer where certain technologies have the potential for improvement.

High efficiency↗

Study on Intelligent Compaction-Equipment Logistics Scheduling and Propagation Characteristics of Vibration Wave in Nonlinear Systems with Multistability Based on Field Test

The equipment scheduling and propagation characteristics of vibration wave from vibratory roller ⟶ filling material nonlinear systems with multistability are the core problems of subgrade intelligent construction technology, and the logistics scheduling of the equipment is directly related to the construction efficiency. Aiming at the shortages, one typical subgrade located at the Gu’an station of Beijing-Xiong’an city railway is selected to research and finish the field tests; some findings are shown as follows: first, some valuable suggestions about the logistics scheduling of intelligent equipment are proposed, which can break the barriers between the organizations and improve construction efficiency; second, when the vibration wave propagates from the vibratory roller ⟶ surface of filling material ⟶ different buried depths of filling material, the peak acceleration of vibration wave gradually decreases and is hyperbolic distribution approximately. At the same time, the sensitive of attenuation is shown as follows: Z R 2 >0.9), and the concrete functional relationship among different amplitudes of harmonics can be summarized as y = Ae −BX ; fourth, the vibration energy is mainly concentrated near 10–30 Hz in the vibratory roller, but when the vibration wave propagates from vibratory roller⟶filling material, the vibration energy gradually decreases with the increase in depth, and the marginal spectrum gradually changes from one peak to two peaks, that is, 30–50 Hz and 50–100 Hz; fifth, the vibration energy in the vibrational wheel is distributed averagely in the compaction process, and the effective compaction time is two seconds, which will be helpful for revealing the propagation characteristics of vibration wave, optimizing the compaction quality control models and providing some support for the development of intelligent compaction theory of railway subgrade.

Han, Yixuan↗

NGEE Arctic Phase 4 Plant Functional Type Framework for Pan-Arctic Vegetation

The NGEE-Arctic research team identified a common set of hierarchical plant functional types (PFTs) for pan-arctic vegetation that we will use across our research activities. Interdisciplinary work within a large team requires agreement regarding levels of functional organization so that knowledge, data, and technologies can be shared and combined effectively. The team has identified plant functional types as a crucial area where such interoperability is needed. PFTs are used to represent plant pools and fluxes within models, summarize observational data, and map vegetation across the landscape. Within each of these applications, varying levels of PFT specificity are needed according to the specific scientific research goal, computational limitations, and data availability. By agreeing on a specific hierarchical framework for grouping variables in our vegetation data, we ensure the resulting research products will be robust, flexible, and scalable. In this document, we lay out the agreed upon PFT framework with definitions and references to existing literature. Table 1 included in the "NGA700_Phase4PFTFramework_about*" file outlines the relationship between NGEE-Arctic Phase 4, Tier 1 PFTs and the PFTs used within prominent arctic literature as well as publications by the NGEE-Arctic team during phases 1-3.This dataset consists of a table detailing a hierarchical PFT framework that spans 4 tiers with the most granular PFTs listed in tier 1 and the most general PFTs in tier 4. The PFTs within each tier has a single column in the dataset where the PFTs are named and a separate column where the characteristics used to define that PFT are listed. Grey fill of the cells is used to indicate where a given PFT starts to “lose” tier 1 details as you look from left to right. Note the excel file has merged cells to indicate grouping of PFTs across the Tiers- it will not translate into a delimited filetype (.csv, .txt, etc) without modification thus the hierarchical PFT framework table is available in three different file formats: 1) NGA700_Phase4PTS.xlsx – maintains the merged cells and grey fill; 2) NGA700_Phase4PTS.csv – merged cells are split, and grey fill is removed; 3) NGA700_Phase4PTS.pdf – image of the table with merged cells and grey fill. Metadata document included as a *.pdf and file-level metadata and data dictionary as *.csv files.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Monitoring of Fracture Dynamics with a Contrast Agent-Assisted Electromagnetic Method

In collaboration with the Advanced Energy Consortium, our team has previously demonstrated that the placement of electrically active proppants (EAPs) in a hydraulic fracture surveyed by electromagnetic (EM) methods can enhance the imaging of the stimulated reservoir volumes during hydraulic fracturing. That work culminated in constructing a well-characterized EAP-filled fracture anomaly at the Devine field pilot site (DFPS). In subsequent laboratory studies, we observed that the electrical conductivity of our EAP correlates with changes in pressure, salinity, and flow. Thus, we postulated that the EAP could be used as an in-situ sensor for the remote monitoring of these changes in previously EAP-filled fractures. This paper presents our latest field data from the DFPS to demonstrate such correlations at an intermediate pilot scale. We conducted surface-based EM surveys during freshwater (200 ppm) and saltwater (2,500 ppm) slug injections while running surfaced-based EM surveys. Simultaneously, we measured the following: 1) bottomhole pressure and salinity in five monitoring wells; 2) injection rate using high-precision data loggers; 3) distributed acoustic sensors in four monitoring wells; and 4) tiltmeter data on the survey area. We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, by comparing the electrical field traces with the bottomhole pressure, flow rate, and salinity, we concluded that the observed electric field in our study is influenced by fracture dilation and flow rate. Salinity effect was observed when saltwater was injected. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce all of the measured electric field magnitudes. Preliminary estimates showed that including streaming potential in our geophysical model may be needed to reduce the simulation mismatch. The methods developed and demonstrated during this study will lead to a better understanding of the extent of fracture networks, formation stress states, fluid leakoff and invasion, characterizations of engineered fracture systems, and other applications where monitoring subsurface flow tracking is deemed important.

02 PETROLEUM↗

ORNL Input to GDSA Repository Systems Analysis FY21

This document satisfies the M3 milestone M3SF-21OR010304082 titled “ORNL Input to GDSA Repository Systems.” This document describes the current status of Oak Ridge National Laboratory’s (ORNL’s) efforts related to analyses of dual-purpose canister (DPC) disposal in unsaturated alluvium with a focus on thermal hydrological constraints on criticality timing and power output. This analysis updates previous analyses of thermal hydrological constraints on timing and power output of a potential criticality event in Dual-Purpose Canisters (DPCs) in a hypothetical repository in unsaturated alluvium using a more realistic representation of heat transport inside dry DPCs. PFLOTRAN was used for the simulations of multiphase thermal hydrology near a single DPC. The scenario considers a DPC failure at 9000 years, allowing water to enter and eventually fill the DPC. Once the DPC is filled to a level that could support a criticality event, different values for criticality power output were added to the decay heat. The main objective is to bound the power output that could be produced by a criticality event without driving water out of the package. For the conditions analyzed here, following a package breach, the alluvial formation could supply enough water to allow enough accumulation in the DPC to support a criticality event. However, the power output that would be generated is limited to modest values by loss of water moderator due to evaporation and vapor diffusion. In the reference case scenario, the DPC would not start to fill with water until about 16,000 years post closure and would not fill to a level that allows a criticality event until approximately 25,000 years post closure. The long-term average power output that could be sustained without driving off the water and terminating the criticality event is limited to approximately 100 W. Sensitivity to assumed conditions and parameters in the reference case, especially the deep percolation rate, need to be addressed but could not be undertaken because of numerical failures of the PFLOTRAN code running in general mode in the dry conditions of an unsaturated alluvium repository

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identify and Assess Technical Challenges in Safeguards Measurements of Spent Advanced Reactor Fuels

Advanced reactor (AR) designs use various nuclear fuel types that can be significantly different than conventional light-water reactor (LWR) fuels, including differences in sizes, compositions, and chemical forms (e.g., oxide, carbide, metal). Nearly all the proposed AR fuels use high-assay low-enriched uranium (HALEU), which will have higher enrichments (5–20 wt% 235 U) than LWR fuels (currently limited to <5 wt% 235 U). In advance of the wide use of these new fuel types around the world, international safeguards organizations such as the International Atomic Energy Agency (IAEA]) are working with some of the AR vendors to formulate safeguards approaches for these AR fuel cycles. As part of the overall safeguards approach, it is important to identify the potential technical challenges in performing safeguards verification measurements of these AR fuels (both fresh and spent fuels) in advance of the widespread adoption of these new fuel types, because new safeguards technologies can take several years to develop, test, and approve for use. This report documents work performed in fiscal year 2024 based on modeling and simulation to assess the performance of the existing safeguards measurement technologies for irradiated or spent AR fuel elements or items. This work is a continuation of the work performed in fiscal year 2023 that focused on fresh AR fuels. Spent AR fuels have a distinct difference from their LWR counterparts: unlike the spent LWR fuels typically stored in a water-filled pool, some spent AR fuels—such as tristructural-isotropic (TRISO)-based fuels—will most likely be stored in air-filled hot cells. Because most safeguards measurements on spent fuel performed to date have been conducted under water, the air-filled hot cell environment could present unique challenges to safeguards measurements. Fork detector (FDET) and Cerenkov viewing device (CVD) systems have been the two primary instruments used by the IAEA for several decades to measure spent LWR fuel assemblies stored in pools for safeguards verification purposes. Because the lower refractive index of air causes Cerenkov light to be of lower intensity in air than in water, existing CVDs are likely unable to perform safeguards verification measurements for spent fuel stored in an air-filled hot cell, as is the case for the TRISO-based spent fuel elements (e.g., pebbles, graphite fuel blocks). Unlike FDET measurements, CVD measurements do not require fuel be moved, so they are a simpler and faster to take than FDET measurements. The inability to perform CVD measurements on the TRISO-based AR fuel types presents a major technical challenge in the effort to use existing technology to perform safeguards measurements on spent AR fuels. This study was mainly conducted through the modeling and simulation of an FDET or an FDET-like system on five spent AR fuel types, including one metallic fuel type and four TRISO-based fuel types in both pebble and graphite block forms in their respective storage configurations and environments. Because the various AR fuel types have significantly different dimensions, FDET systems must be adapted to accommodate them. Partial defect tests were also simulated in this study to assess the FDET’s ability to detect potential fuel diversions. The FDET measures the fuel’s total passive neutron and gamma emissions. The simulated FDET results from spent AR fuel items are compared against results from a typical spent pressurized water reactor (PWR) assembly. High-purity germanium (HPGe) gamma detector measurements were also simulated for the spent AR fuel types and the PWR assembly because the signature photopeaks have been used in LWR safeguards verifications, although HPGe is usually not used to detect diversions because of the fuel’s self-attenuation effects on those photopeaks. The results indicate that these detectors have significant challenges in performing safeguards measurements of the spent AR fuel items, including incompatibilities between AR fuel items and existing FDETs, lower neutron count rates, lower sensitivities to fuel diversions in certain AR fuel items, and significantly higher interference from a neighboring fuel item when the measurement is performed in air. These results suggest that an alternative technology or significant and timely technology development is needed to perform adequate safeguards measurements of some of these AR fuel items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Balancing Functionality and Printability: High-Loading Polymer Resins for Direct Ink Writing

Although direct ink writing (DIW) allows the rapid fabrication of unique 3D printed objects, the resins—or “inks”—available for this technique are in short supply and often offer little functionality, leading to the development of new, custom inks. However, when creating new inks, the ability of the ink to lead to a successful print, or the “printability,” must be considered. Thus, this work examined the effect of filler composition/concentration, printing parameters, and lattice structure on the printability of new polysiloxane inks incorporating high concentrations (50–70 wt%) of metallic and ceramic fillers as well as emulsions. Results suggest that strut diameter and spacing ratio have the most influence on the printability of DIW materials and that the printability of silica- and metal-filled inks is more predictable than ceramic-filled inks. Additionally, higher filler loadings and SC geometries led to stiffer printed parts than lower loadings and FCT geometries, and metal-filled inks were more thermally stable than ceramic-filled inks. The findings in this work provide important insights into the tradeoffs associated with the development of unique and/or multifunctional DIW inks, printability, and the final material’s performance.

36 MATERIALS SCIENCE↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Methodology to determine printability criteria of highly concentrated pastes through rheological characterization

Material extrusion is an additive manufacturing technique that enables the creation of reproducible and complex hardware by depositing a viscous, shear-thinning ink onto a substrate in a custom-pattern via extrusion through a syringe. Here, the ability of an ink to be extruded onto a substrate in many layers, and maintain the desired shape is what defines the printability. Printability is often investigated by formulating, printing, and postmortem analysis of final parts in an iterative manner. Investigations of printability through rheological characterization have often been concerned with inks that straddle the line between printable and too thin, leaving out an entire class of inks that are highly-filled pastes, where extrudability is the limiting factor. Highly-filled pastes continue to pose issues for researchers as the effect of filler morphology, size, loading, and packing fraction on the ink rheology and corresponding printability is not understood. While traditional rheological characterizations may be useful for some inks, we show that protocols utilizing steady-shear, or large-amplitude oscillatory shear are difficult and unreliable for highly-filled pastes. Through transient rheology paired with real-time images we show that each traditional protocol produces inhomogeneous deformations that violate the assumptions that underly common rheological definitions. Instead, we demonstrate metrics measured with small-amplitude oscillatory shear that are correlated to the printability of various ink formulations ranging in loading. The rheological measures that accurately predict the printability of the inks are the axial stress measured at small amplitudes, and the critical stress amplitude above which rheological characterizations become impossible. In addition, we estimate the maximum packing fraction for each filler, based on the exponent common to hard sphere models, and show that the printability of each ink can be predicted by the ratio of the packing fraction to the theoretical maximum. We show how small-amplitude oscillatory shear allows users to develop printability criteria for any ink to enhance the workflow in the development of new inks, increase the performance of material extrusion printing, and improve the stability of printed parts, with less wasted time and materials.

36 MATERIALS SCIENCE↗

Coal Ash Beneficial Use at Savannah River Site

The Savannah River Site (SRS) has over 1.4 million cubic meters of coal ash and coal fines left over from coal-burning power plants that operated on site. Currently, the coal ash must be disposed of in an approved landfill or the coal ash-containing basins must be closed in place (i.e. consolidation, appropriate cover and liner system). Potential beneficial uses of the coal ash include geotechnical fill, such as backfill needed in the closure cap of the Z-area Saltstone Disposal Units (SDU), and use in cementitious material applications like thermal beneficiation or cement kiln feed, thereby reducing the environmental footprint of SRS. In this study, samples of coal ash from SRS were obtained and characterized for chemical and physical properties. Coal ash samples did not leach sulfates or heavy metals, so the coal ash is a candidate for geotechnical fill use. The samples also did not increase the acidity of the leachate during leaching tests, so it would not be detrimental to use as geotechnical fill near cementitious materials. The composition and energy potential of the coal ash makes it favorable for use as feed for external/off-site cement kilns or thermal beneficiation plants

01 COAL, LIGNITE, AND PEAT↗

Development, verification, and validation of comprehensive acoustic fluid-structure interaction capabilities in an open-source computational platform

The acoustic fluid-structure interaction (FSI) formulation is a practical numerical approach for the seismic analysis of fluid-filled tanks. However, there are no verification and validation studies reported in the literature that demonstrate the ability of an acoustic FSI numerical model to predict responses important to structural and mechanical design for intense translational and rotational earthquake inputs. Herein, an acoustic FSI formulation is implemented in the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE), and is formally verified and validated using analytical solutions and code-to-code verification, and experimental data, respectively. The analytical solutions are for small amplitude, unidirectional seismic inputs. The code-to-code verification utilizes a previously verified and validated Arbitrary Lagrangian-Eulerian (ALE) numerical model in the commercial finite element code LS-DYNA. The validation studies utilize a comprehensive data set assembled from results of 3D earthquake-simulator tests of a fluid-filled vessel. The acoustic numerical model in MOOSE is verified and validated for hydrodynamic pressures and support reactions except for cases that involve significant convective response. For small amplitude inputs, numerically predicted wave heights match those of the analytical solutions. The numerical model is not verified and validated for wave height calculations under intense 3D seismic inputs. The run times for the acoustic FSI simulations in MOOSE are an order of magnitude, or more, shorter than for the corresponding ALE simulations in LS-DYNA. The utility of the MOOSE acoustic FSI implementation is demonstrated by seismic analysis of a building equipped with a fluid-filled, advanced nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radial storage efficiency for CO 2 injection: Quantifying effectiveness of local flow control methods

Basin-scale geologic carbon sequestration will require hundreds of injection wells, each of which has costs related to property rights and regulatory requirements that correlate with the areal size of the carbon dioxide plume. These surface-footprint-related issues motivate maximizing storage efficiency radially away from each well. Radial storage efficiency (RSE) is defined here as the ratio of the volumetrically weighted carbon dioxide free-phase saturation within a given radius away from the injection well to the available pore space within that same radius. Maximizing RSE effectively minimizes the radial extent of the CO 2 plume. Optimizing RSE around individual wells requires local flow control injection strategies that can increase the uniformity of the filling of pore space around the well over the entire length of the perforated injection interval despite differences in local formation transmissivity. The goal of uniform filling of the storage reservoir starting from the well outward is to maximize carbon dioxide sweep and trapping locally outward from the well in all of the layers of the storage region before buoyancy forces predominate and drive carbon dioxide upward where it will spread laterally under lower-permeability layers. Example simulations of carbon dioxide injection into a layered storage system with and without local flow control are presented to show the advantage of uniformly filling all layers and how RSE can be used to quantify storage efficiency for the two different injection approaches. Published 2021. This article is a U.S. Government work and is in the public domain in the USA.

03 NATURAL GAS↗

Genetic variation in nitrogen‐use efficiency and its associated traits in dryland winter wheat ( Triticum aestivum L.) cultivars released from the 1940s to the 2010s in Shaanxi Province, China

Abstract BACKGROUND Improving the nitrogen‐use efficiency (NUE) of wheat can help mitigate the problems of poor soil fertility under dryland conditions. We conducted field experiments using three nitrogen (N) fertilization levels (0, 120, and 180 kg ha −1 ) applied to eight dryland wheat cultivars to assess NUE and its associated traits. RESULTS The grain yield significantly increased with the improvement in variety, mainly as a result of a substantial increase in 1000‐grain weight and harvest index. Modern wheat varieties have stabilized at an optimal plant height and exhibited improved performance in terms of NUE, partial N productivity, N harvest index, and grain protein content compared to older varieties. The NUE of wheat gradually increased with variety replacement. The net photosynthesis rate of the flag leaves in the filling stage improved with the year of cultivar release; Increasing soil–plant analysis development (SPAD) values of flag leaves in the flowering and filling stages were observed over time, with the flag leaves of modern varieties showing a high chlorophyll content in the filling stage. Additionally, the principal component analysis showed that the SPAD value, grain number per unit area, transpiration rate, leaf area, and grain protein content positively contributed to the clustering of the N180 and modern cultivars (from the 2000s to 2010s). CONCLUSION Overall, high levels of N application did not significantly improve the NUE of wheat. However, modern wheat varieties can optimize N distribution, increase flag leaf photosynthetic capacity, and improve photosynthesis ability, thus enhancing NUE to achieve high yields under a suitable level of N supply. © 2022 Society of Chemical Industry.

Lian, Huida↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗