Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Real-time processor for staring receivers

The design, fabrication, and testing of a state-of-the-art, high-throughput on-focal plane IR-image signal processor is described. The processing functions performed are frame differencing and thresholding. The final focal plane array will consist of a 128 x 128-pixel platinum-silicide detector bump-mounted to an on-chip CCD multiplexer. The processor is in a 128-channel parallel-pipeline format. Each channel consists of a pixel regenerator (charge differencer), 128-pixel frame store CCD memory, pixel differencer, second pixel regenerator, thresholder (analog comparator), and digital latch. Four parallel analog outputs and four parallel digital outputs are included. The digital outputs provide a bit map of the image. All analog clock signals (128 KHz, 256 KHz, and 5 MHz) are generated by on-chip TTL-input clock drivers. TTL clock driver inputs are generated off-chip. The technology is low-temperature surface and buried channel CCD/CMOS/indium bump. The design goal was 8-bit resolution at 77 K and 1000 frames/s. Applications include point- or extended-target motion detection with thresholding. Design trade-offs and enhancements (such as on-chip detector gain compensation and a simple window processor) are discussed.

Hanzal, Brian↗

Design and performance of very long-wavelength GaAs/Al(x)Ga(1-x)As quantum-well infrared photodetectors

We present an extensive and detailed study of very long wavelength quantum well infrared photodetectors covering the spectral region between 14 and 20 micrometers. Measurements were made on seven different molecular beam epitaxy grown samples having different well widths and barrier heights. In this study we combine experimental results with theoretical analysis and focus on the relationship between the quantum well structure and detector performance, i.e., responsivity, dark current, dynamic resistance, noise current, optical-gain, and detectivity. These results provide the basis for further optimization, and the detector parameters needed for the design of the readout circuit for focal plane arrays.

Sarusi, G.↗

The giant molecular cloud Monoceros R2. 1: Shell structure

We have obtained a 45 sec resolution, Nyquist-sampled map in CO J = 1-0 covering approximately a 3 deg x 3 deg region of the giant molecular cloud Monoceros R2. The map consists of 167,000 spectra observed with the 15 element focal-plane array system on the FCRAO 14 m telescope. The data reveal that the large-scale structure of Mon R2 is dominated by a is approximately 30 pc diameter largely hemispherical shell containing approximately 4 x 10(exp 4) solar mass of molecular material and expanding at approximately 3-4 km s(exp -1) with symmetric axis roughly along the line of sight. The dynamical timescale of the shell is estimated to be approximately 4 x 10(exp 6) yr, which is consistent with the age of main-sequence stars powering the clusters of reflection nebulea in this region. There is no evidence for a redshifted shell on the far side of the interior 'bubble,' which is largely devoid of molecular material. Distortions of the shell are obvious, suggesting inhomogeneity of the cloud and possible presence of a magnetic field prior to its formation. Dense clumps in Mon R2, including the main core and the GGD 12-15 core, appear to be condensations located on the large shell. The reflection nebulea with their illuminating stars as well as embedded IRAS sources suggest that triggered star formation has taken place over a large part of the Mon R2 shell.

Xie, Taoling↗

A visible-infrared imaging spectrometer for planetary missions

This final report summarizes the design effort for the construction of a visible-infrared imaging spectrometer for planetary missions, funded by NASA under the Planetary Instrument Definition and Development Program. The goal was to design and develop a prototype brassboard pushbroom imaging spectrometer covering the 0.35 gm to 2.5 gm spectral region using a simplified optical layout that would minimize the size, mass and parts count of the instrument by using a single holographic grating to disperse and focus light from a single slit onto both the infrared and visible focal plane arrays. Design approaches are presented and analyzed, along with problems encountered and recommended solutions to those problems. In particular, a new type of grating, incorporating two sets of rulings and a filter in a layered structure, is presented for further development.

McCord, Thomas↗

Characterization of Infrared Diode Laser Beams and Atmospheric CO Imaging Instrument

During June-August 1997 Dr. Jonathan Miles participated in the ASEE-sponsored summer faculty research program at NASA Langley Research Center (LaRC). The Aerospace Electronic Systems Division (AESD), Sensor Systems Branch (SSB), at NASA LARC had proposed a new mission, GEOstationary TROpospheric Pollution SATellite (GEO TROPSAT), to address critical science questions of tropospheric chemistry. The troposphere is a complex system, comprising "point" and distributed sources of natural and anthropogenic origin; complicated transport processes, both lateral and vertical; and photochemistry driven by UV flux, temperature, atmospheric composition, and other variables. GEO TROPSAT would be implemented about a geostationary Earth orbital (GEO) position at the equator between 600 and 80" West longitude to observe the Americas and large portions of the oceans of either coast. This mission would advance our knowledge of the atmosphere by capturing the wide temporal and spatial variability of tropospheric phenomena which is undetectable from low Earth orbit. A pre-prototype imaging carbon monoxide (CO) imaging system operating within a narrow waveband about 4.7 [Lm was built, demonstrated, and evaluated. This system applies the gas-filter correlation radiometry (GFCR) technique and produces digitized images comprising 4096 pixels, each representing a single CO mixing ratio measurement inferred from radiometric data. Associated tasks accomplished included specification for the next-generation prototype system to operate in the 2.3-@tm waveband; characterization of a 64x64, InSb focal-plane-array (FPA) imager; design, fabrication, and assembly of a filter wheel; and software development. Laboratory evaluation of this system involved imaging of a test cell placed in the path of radiant flux emanating from a blackbody source used to simulate the radiant energy reflected by Earth in real application. The cell was evacuated for system balancing and then charged with measured quantities of CO to provide a means for system characterization. Two related research efforts were undertaken during the term of the study reported here - continued development of an atmospheric CO imaging instrument and characterization of diode-laser beams. Both efforts were successful and are described within the body of this report. A second objective was to provide a means for undergraduate ISAT majors to become involved with the research described, to be afforded the opportunity to learn the technologies associated with the work performed. Two ISAT students gained a comprehensive understanding and interest in missions supported by NASA through direct involvement in this project. Many more students were exposed to these technologies through demonstrations, laboratory tours, and explanations provided in lectures.

Miles, Jonathan J.↗

Long-Wavelength 256 x 256 QWIP Hand-Held Camera

In this paper, we discuss the development of very sensitive long wavelength infrared (LWIR) GaAs/Al(x)Ga(l-x)As quantum well infrared photodetectors (QWIPs), fabrication of random reflectors for efficient light coupling, and the demonstration of the first hand-held long-wavelength 256 x 256 QWIP focal plane array camera. Excellent imagery, with a noise equivalent differential temperature (NE Delta T) of 25 mK has been achieved.

Gunapala, S. D.↗

Solution for Direct Solar Impingement Problem on Landsat-7 ETM+ Cooler Door During Cooler Outgas in Flight

There was a thermal anomaly of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) radiative cooler cold stage during the cooler outgas phase in flight. With the cooler door in the outgas position and the outgas heaters enabled, the cold stage temperature increased to a maximum of 323 K when the spacecraft was in the sunlight, which was warmer than the 316.3 K upper set point of the outgas heater controller on the cold stage. Also, the outgas heater cycled off when the cold stage was warming up to 323 K. A corrective action was taken before the attitude of the spacecraft was changed during the first week in flight. One orbit before the attitude was changed, the outgas heaters were disabled to cool off the cold stage. The cold stage temperature increase was strongly dependent on the spacecraft roll and yaw. It provided evidence that direct solar radiation entered the gap between the cooler door and cooler shroud. There was a concern that the direct solar radiation could cause polymerization of hydrocarbons, which could contaminate the cooler and lead to a thermal short. After outgas with the cooler door in the outgas position for seven days, the cooler door was changed to the fully open position. With the cooler door fully open, the maximum cold stage temperature was 316.3 K when the spacecraft was in the sunlight, and the duty cycle of the outgas heater in the eclipse was the same as that in the sunlight. It provided more evidence that direct solar radiation had entered the gap between the cooler door and cooler shroud. Cooler outgas continued for seven more days, with the cooler door fully open. The corrective actions had prevented overheating of the cold stage and cold focal plane array (CFPA), which could damage these two components. They also minimized the risk of contamination on the cold stage, which could lead to a thermal short.

Choi, Michael K.↗

Significance of Landsat-7 Spacecraft Level Thermal Balance and Thermal Test for ETM+Instrument

The thermal design and the instrument thermal vacuum (T/V) test of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument were based on the Landsat-4, 5 and 6 heritage. The ETM+ scanner thermal model was also inherited from Landsat-4, 5 and 6. The temperature predictions of many scanner components in the original thermal model had poor agreement with the spacecraft and instrument integrated sun-pointing safehold (SPSH) thermal balance (T/B) test results. The spacecraft and instrument integrated T/B test led to a change of the Full Aperture Calibrator (FAC) motor stack "solar shield" coating from MIL-C-5541 to multi-layer insulation (MLI) thermal blanket. The temperature predictions of the Auxiliary Electronics Module (AEM) in the thermal model also had poor agreement with the T/B test results. Modifications to the scanner and AEM thermal models were performed to give good agreement between the temperature predictions and the test results. The correlated ETM+ thermal model was used to obtain flight temperature predictions. The flight temperature predictions in the nominal 15-orbit mission profile, plus margins, were used as the yellow limits for most of the ETM+ components. The spacecraft and instrument integrated T/B and TN test also revealed that the standby heater capacity on the Scan Mirror Assembly (SMA) was insufficient when the Earth Background Simulator (EBS) was 1 50C or colder, and the baffle heater possibly caused the coherent noise in the narrow band data when it was on. Also, the cooler cool-down was significantly faster than that in the instrument T/V test, and the coldest Cold Focal Plane Array (CFPA) temperature achieved was colder.

Choi, Michael K.↗

Thermal Assessment of Landsat-7 ETM+ Radiative Cooler in Instrument and Spacecraft Thermal Vacuum Tests and in Flight

During the radiative cooler cool-down phase of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument thermal vacuum test #3, the coldest temperature that the Cold Focal Plane Array (CFPA) achieved was 89.5 K. The cold stage/CFPA temperature decreased from 315 K to 89.5 K in 80 hours. In the spacecraft and instrument integrated thermal vacuum test, the cold stage/CFPA temperature decreased from 315 K to 86.9 K in 80 hours, and was still decreasing at a rate of 0.08 K/hr when the cool-down was terminated. The cool-down was faster, and a colder CFPA temperature was obtained. In flight, the cooler cool- down was even faster, and colder. The cold stage/CFPA temperature decreased from 315 K to 89.7 K in 33 hours, and was still decreasing at a rate of 1 K/hr when cool- down was terminated at 89.7 K. The factors that affected the ETM+ cooler cool-down are the radiation heat sink temperature for the cold stage and intermediate stage, parasitic radiation heat load to the cooler, parasitic conduction heat load to the cooler, and cooler outgas time preceding cooler cool-down.

Choi, Michael K.↗

Development of the Double Etalon Fabry-Perot Interferometer for Determining Total and Tropospheric Ozone Concentrations

Measuring and understanding the distribution of ozone through the lower levels of Earth's atmosphere are high priorities in global change and climate research. Of particular interest now is the global distribution of ozone in the upper troposphere and lower stratosphere. Global coverage of the stratospheric ozone is feasible only via remote sensing instruments on a space-based platform. And though extensive monitoring tropospheric ozone is possible using instruments flown aboard conventional aircraft, a space-based system would be significantly less costly and provide information over a much broader area and produce more uniform coverage. Here we describe the prototype of an instrument being developed to monitor, from an orbiting spacecraft, the ozone found in Earth's upper troposphere and lower stratosphere. Our new spectrometer is an infrared Fabry-Perot interferometer which uses two synchrounously tuned etalons: a high resolution narrow band device and a lower resolution broader band filtering etalon. The prototype is a scanning device making use of nearly collimated input radiation and a single element detector. As presently configured, it is capable of providing a resolution better than 0.07/cm with a spectral band width approximately 5/cm wide and centered at 1054.7/cm. For the future space-based emission device a modification of the the prototype was to be made to employ innovative circle-to-line detector optics, those developed or in development at UM/SPRL, and a focal plane array detector. These enhancements would enable a simultaneous recording of the entire spectral range of interest, but with simple detection electronics and a significant gain in signal-to-noise over that of the scanning version.

Cook, William↗

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Design of a 2.5 Gbps Optical Transmitter for the International Space Station

A high data rate laser transmitter assembly (LTA) has been designed as the source for an optical free-space communication link between the International Space Station and the 1-meter Optical Communication Telescope Laboratory (OCTL) to be built at the Table Mountain Facility (IMF, Wrightwood, CA). The transmitter design concept uses a fiber-based master oscillator power amplifier (MOPA) configuration with an average output power of 200 made at a 1550 nm transmit wavelength. This transmitter source is also designed to provide a signal at 980 nm to the Silicon-based focal plane array for the point-ahead beam control function. This novel integration of a 980 nm boresight signal allows the use of Silicon based imagers for the acquisition/tracking and point-ahead functions, yet permits the transmit signal to be at any wavelength outside the Silicon sensitivity. The LTA, a sub-system of the Flight Terminal, has been designed to have a selectable data rate from 155 - 2500 Mbps in discrete steps. It also incorporates a 2.5 Gbps pseudo-random bit sequence (PRBS) generator for complete link testing and diagnostics. The design emphasizes using commercial off the shelf components (COTS).

Ortiz, Gerardo G.↗

Optical Communication Transceiver For X2000; Second Delivery Program

Conceptual-design of a multi-functional optical instrument is underway for the X2000 - Second Delivery Program. The transceiver will perform both free-space optical- communication and science imaging by sharing a common 10-cm aperture telescope. A single focal-plane array (such as, APS-Active Pixel Sensor) in conjunction with a filter wheel will be used to perform the two functions. Targeted values for the transceiver's weight and power consumption are: 4 Kg, and 14 W. This transceiver would be capable of delivering greater than IO Kbps to a 3.5-m diameter receiving station from the range of 2 AU during day-time.

Hemmati, H.↗

A Near IR Fabry-Perot Interferometer for Wide Field, Low Resolution Hyperspectral Imaging on the Next Generation Space Telescope

We discuss work in progress on a near-infrared tunable bandpass filter for the Goddard baseline wide field camera concept of the Next Generation Space Telescope (NGST) Integrated Science Instrument Module (ISIM). This filter, the Demonstration Unit for Low Order Cryogenic Etalon (DULCE), is designed to demonstrate a high efficiency scanning Fabry-Perot etalon operating in interference orders 1 - 4 at 30K with a high stability DSP based servo control system. DULCE is currently the only available tunable filter for lower order cryogenic operation in the near infrared. In this application, scanning etalons will illuminate the focal plane arrays with a single order of interference to enable wide field lower resolution hyperspectral imaging over a wide range of redshifts. We discuss why tunable filters are an important instrument component in future space-based observatories.

Barry, R. K.↗

Long-Wavelength 640 x 486 GaAs/AlGaAs Quantum Well Infrared Photodetector Snap-Shot Camera

A 9-micrometer cutoff 640 x 486 snap-shot quantum well infrared photodetector (QWIP) camera has been demonstrated. The performance of this QWIP camera is reported including indoor and outdoor imaging. The noise equivalent differential temperature (NE.deltaT) of 36 mK has been achieved at 300 K background with f/2 optics. This is in good agreement with expected focal plane array sensitivity due to the practical limitations on charge handling capacity of the multiplexer, read noise, bias voltage, and operating temperature.

Gunapala, Sarath D.↗

Earth Observing-1 Advanced Land Imager: Radiometric Response Calibration

The Advanced Land Imager (ALI) is one of three instruments to be flown on the first Earth Observing mission (EO-1) under NASA's New Millennium Program (NMP). ALI contains a number of innovative features, including a wide field of view optical design, compact multispectral focal plane arrays, non-cryogenic HgCdTe detectors for the short wave infrared bands, and silicon carbide optics. This document outlines the techniques adopted during ground calibration of the radiometric response of the Advanced Land Imager. Results from system level measurements of the instrument response, signal-to-noise ratio, saturation radiance, and dynamic range for all detectors of every spectral band are also presented.

Mendenhall, J. A.↗

Simulated Performance of the Orbiting Wide-angle Light Collectors (OWL) Experiment

The Orbiting Wide-angle Light collectors (OWL) experiment is in NASA's mid-term strategic plan and will stereoscopically image, from equatorial orbit, the air fluorescence signal generated by airshowers induced by the ultrahigh energy (E greater than few x 10(exp 19) eV) component of the cosmic radiation. The use of a space-based platform enables an extremely large event acceptance aperture and thus will allow a high statistics measurement of these rare events. Detailed Monte Carlo simulations are required to quantify the physics potential of the mission as well as optimize the instrumental parameters. This paper reports on the results of the GSFC Monte Carlo simulation for two different, OWL instrument baseline designs. These results indicate that, assuming a continuation of the cosmic ray spectrum (theta approximately E(exp -2.75), OWL could have an event rate of 4000 events/year with E greater than or equal to 10(exp 20) eV. Preliminary results, based upon these Monte Carlo simulations, indicate that events can be accurately reconstructed in the detector focal plane arrays for the OWL instrument baseline designs under consideration.

Krizmanic, J. F.↗

Fully "Eqwipped" to See the Heat

Developed by NASA's Jet Propulsion Laboratory over the past decade with an excess of $15 million of government research and development investment, quantum well infrared photodetectors (QWIPs) are infrared imaging sensors that can operate in the long wavelength portion of the electromagnetic spectrum, where objects at an ambient temperature emit the most energy. QWIPTECH was formed in July 1998 to offer JPL's QWIPs in a commercial format. The company currently holds an exclusive worldwide license to manufacture and sell the infrared photodetector sensors as part of a focal plane array called a QWIP Chip(TM). The QWIP Chip provides high thermal sensitivity (0.001 C) and possesses a broad dynamic range, permitting precise observations over a wide range of temperatures. Since the technology uses heat rather than light, it can "see" in complete darkness and through conditions such as dust, smoke, and light fog.

Source record↗