A symmetric modal formulation of fluid-structure interaction, including a static approximation to higher order fluid modes

A method of fluid-structure coupling which provides symmetrical matrix equations of standard form solved by existing finite element computer programs is presented. The method postulates that the uncoupled vibration modes of the fluid or the structure be calculated before the coupled analysis. A numerical solution of vibration modes in an axisymmetric container demonstrated that a static approximation to higher order fluid modes can improve the accuracy of dynamic response computations using modal methods.

Macneal, R. H.↗

Comparison of Southern Hemisphere radiosonde and LIMS temperatures at 100 mb

Radiosonde (RS)and satellite-derived (Nimbus-7 LIMS) 100-mb temperatures over New Zealand at 12 GMT are compared for the 1978-79 summer. The colocated LIMS temperature information consists of synoptically mapped values (for 12 GMT), as well as the primary nighttime orbital retrievals valid at about 1030 GMT. The RS time series of temperature is dominated by temporal fluctuations associated mainly with the eastward passage of waves which have characteristic periods of 4-5 and 11-12 days and peak-to-peak amplitudes of 10-15 K. The LIMS temperatures and the corresponding temperature time series are also found to exhibit quite close agreement (in terms of temporal phase for the latter) with the RS data. However, the LIMS-mapped temperature fluctuations suffer from a noticeable attenuation in amplitude (approaching 50 percent for higher-frequency fluctuations), which will affect the accuracy of LIMS-derived estimates of dynamical quantities such as wind velocity and relative vorticity in the lower stratosphere.

Miles, T.↗

Scatterometer azimuthal response and wind wave directionality

Azimuthal response of a scatterometer to radiation scattered by the sea surface was studied in a wind-wave tank. The variation of the normalized radar cross section with the azimuth angle is fitted by a three-term series. Results show that the upwind-downwind asymmetry decreases as the wind speed increases. The crosswind modulation depends on the wind velocity. The results show that the evolution of the long-wind-crosswind ratio evolves with wind speed in a manner similar to the evolution of the isotropy of short capillary-gravity waves. The maximum of the isotropy of the short wind waves is obtained for wind velocities close to 4 m/s. For the same value of the velocity, the variations of radar response between long-wind and crosswind directions is minimum. For lower or higher values of wind velocities the directional accuracy of the radar increases, since the wind-wave field tends to align in the wind direction.

Giovanangeli, J. P.↗

Nongray gas analyses for reflecting walls utilizing a flux technique

A flux formulation for a planar slab of molecular gas radiation bounded by diffuse reflecting walls is developed. While this formulation is limited to the planar geometry, it is useful for studying approximations necessary in modeling nongray radiative heat transfer. The governing equations are derived by considering the history of multiple reflections between the walls. Accurate solutions are obtained by explicitly accounting for a finite number of reflections and approximating the spectral effects of the remaining reflections. Four approximate methods are presented and compared using a single absorption band of H2O. All four methods reduce to an identical zeroth-order formulation, which accounts for all reflections approximately but does handle nonreflected radiation correctly. A single absorption band of CO2 is also considered using the best-behaved approximation for higher orders. A zeroth-order formulation is sufficient to predict the radiative transfer accurately for many cases considered. For highly reflecting walls, higher order solutions are necessary for better accuracy. Including all the important bands of H2O, the radiative source distributions are also obtained for two different temperature and concentration profiles.

Menart, J. A.↗

Integrating the Gradient of the Thin Wire Kernel

A formulation for integrating the gradient of the thin wire kernel is presented. This approach employs a new expression for the gradient of the thin wire kernel derived from a recent technique for numerically evaluating the exact thin wire kernel. This approach should provide essentially arbitrary accuracy and may be used with higher-order elements and basis functions using the procedure described in [4].When the source and observation points are close, the potential integrals over wire segments involving the wire kernel are split into parts to handle the singular behavior of the integrand [1]. The singularity characteristics of the gradient of the wire kernel are different than those of the wire kernel, and the axial and radial components have different singularities. The characteristics of the gradient of the wire kernel are discussed in [2]. To evaluate the near electric and magnetic fields of a wire, the integration of the gradient of the wire kernel needs to be calculated over the source wire. Since the vector bases for current have constant direction on linear wire segments, these integrals reduce to integrals of the form

Champagne, Nathan J.↗

NASA Tech Briefs, May 2004

Topics include: Embedded Heaters for Joining or Separating Plastic Parts; Curing Composite Materials Using Lower-Energy Electron Beams; Aluminum-Alloy-Matrix/Alumina-Reinforcement Composites; Fibrous-Ceramic/Aerogel Composite Insulating Tiles; Urethane/Silicone Adhesives for Bonding Flexing Metal Parts; Scalable Architecture for Multihop Wireless ad Hoc Networks; Improved Thermoplastic/Iron-Particle Transformer Cores; Cooperative Lander-Surface/Aerial Microflyer Missions for Mars Exploration Dual-Frequency Airborne Scanning Rain Radar Antenna System Eight-Channel Continuous Timer Reduction of Phase Ambiguity in an Offset-QPSK Receiver Ambient-Light-Canceling Camera Using Subtraction of Frames Lightweight, Flexible, Thin, Integrated Solar-Power Packs Windows(Registered Trademark)-Based Software Models Cyclic Oxidation Behavior Software for Analyzing Sequences of Flow-Related Images Improved Ball-and-Socket Docking Mechanism Two-Stage Solenoid Ordered Nanostructures Made Using Chaperonin Polypeptides Low-Temperature Plasma Functionalization of Carbon Nanotubes Improved Cryostat for Cooling a Wide Panel Current Pulses Momentarily Enhance Thermoelectric Cooling Hand-Held Color Meters Based on Interference Filters Calculating Mass Diffusion in High-Pressure Binary Fluids Fresnel Lenses for Wide-Aperture Optical Receivers Increasing Accuracy in Computed Inviscid Boundary Conditions Higher-Order Finite Elements for Computing Thermal Radiation Radar for Monitoring Hurricanes from Geostationary Orbit Time-Transfer System for Two Orbiting Spacecraft

Source record↗

Height Error Correction for the New SRTM Elevation Product

The Shuttle Radar Topography Mission (SRTM), carrying a single-pass interferometric synthetic aperture radar(SAR) instrument, collected a global elevation data set, which has been widely used in scientific, military and commercial communities. In the new proposed NASA SRTM reprocessing task, the SRTM elevation data is going to be processed at higher spatial resolution and with improved height accuracy. Upon completion, the improved SRTM product will be freely available. This paper describes the calibration approaches for reduction of elevation ripple effects and height accuracy improvements.

Synthetic Aperture Radar Interferometry (InSAR)↗

Position Corrections for Airspeed and Flow Angle Measurements on Fixed-Wing Aircraft

This report addresses position corrections made to airspeed and aerodynamic flow angle measurements on fixed-wing aircraft. These corrections remove the effects of angular rates, which contribute to the measurements when the sensors are installed away from the aircraft center of mass. Simplified corrections, which are routinely used in practice and assume small flow angles and angular rates, are reviewed. The exact, nonlinear corrections are then derived. The simplified corrections are sufficient in most situations; however, accuracy diminishes for smaller aircraft that incur higher angular rates, and for flight at high air flow angles. This is demonstrated using both flight test data and a nonlinear flight dynamics simulation of a subscale transport aircraft in a variety of low-speed, subsonic flight conditions.

Grauer, Jared A.↗

High Fidelity Collision Probabilities Estimated Using Brute Force Monte Carlo Simulations

The NASA Conjunction Assessment Risk Analysis team has implemented new software to estimate the probability of collision (P (sub c)) for Earth-orbiting satellites. The algorithm employs a brute force Monte Carlo (BFMC) method which differs from most other methods because it uses orbital states and covariances propagated from their orbit determination epoch times using the full set of Astrodynamics Support Workstation higher order theory models, including the High Accuracy Satellite Drag Model. This paper de-scribes the BFMC algorithm, presents comparisons of BFMC P (sub c) estimates to those calculated using other methods, and discusses the implications for conjunction risk assessment.

Probabilities↗

Unsteady Pressure Sensitive Paint Camera Calibration Improvements

New challenges have arisen in processing a significantly increased volume of data collected during recent large-scale demonstrations of unsteady pressure-sensitive paint. Techniques designed for several thousands of images collected in a lab do not necessarily scale to tens of millions collected in a large-scale test. New techniques are needed to meet the tighter requirements on robustness and accuracy that accompany larger wind tunnel models, higher camera resolution, and more run conditions per test. This paper outlines several such techniques and improvements in regard to the camera calibration process.

Camera calibration↗

Unsteady Pressure Sensitive Paint Camera Calibration Improvements

New challenges have arisen in processing a significantly increased volume of data collected during recent large-scale demonstrations of unsteady pressure-sensitive paint. Techniques designed for several thousands of images collected in a lab do not necessarily scale to tens of millions collected in a large-scale test. New techniques are needed to meet the tighter requirements on robustness and accuracy that accompany larger wind tunnel models, higher camera resolution, and more run conditions per test. This paper outlines several such techniques and improvements in regard to the camera calibration process.

Camera calibration↗

Geospatial Method for Computing Supplemental Multi-Decadal U.S. Coastal Land-Use and Land-Cover Classification Products, Using Landsat Data and C-CAP Products

This paper discusses the development and implementation of a geospatial data processing method and multi-decadal Landsat time series for computing general coastal U.S. land-use and land-cover (LULC) classifications and change products consisting of seven classes (water, barren, upland herbaceous, non-woody wetland, woody upland, woody wetland, and urban). Use of this approach extends the observational period of the NOAA-generated Coastal Change and Analysis Program (C-CAP) products by almost two decades, assuming the availability of one cloud free Landsat scene from any season for each targeted year. The Mobile Bay region in Alabama was used as a study area to develop, demonstrate, and validate the method that was applied to derive LULC products for nine dates at approximate five year intervals across a 34-year time span, using single dates of data for each classification in which forests were either leaf-on, leaf-off, or mixed senescent conditions. Classifications were computed and refined using decision rules in conjunction with unsupervised classification of Landsat data and C-CAP value-added products. Each classification's overall accuracy was assessed by comparing stratified random locations to available reference data, including higher spatial resolution satellite and aerial imagery, field survey data, and raw Landsat RGBs. Overall classification accuracies ranged from 83 to 91% with overall Kappa statistics ranging from 0.78 to 0.89. The accuracies are comparable to those from similar, generalized LULC products derived from C-CAP data. The Landsat MSS-based LULC product accuracies are similar to those from Landsat TM or ETM+ data. Accurate classifications were computed for all nine dates, yielding effective results regardless of season. This classification method yielded products that were used to compute LULC change products via additive GIS overlay techniques.

Spruce, J. P.↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

A Kinematic Calibration Process for Flight Robotic Arms

The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.

Collins, Curtis L.↗

An analysis of Landsat Thematic Mapper P-Product internal geometry and conformity to earth surface geometry

Performance requirements regarding geometric accuracy have been defined in terms of end product goals, but until recently no precise details have been given concerning the conditions under which that accuracy is to be achieved. In order to achieve higher spatial and spectral resolutions, the Thematic Mapper (TM) sensor was designed to image in both forward and reverse mirror sweeps in two separate focal planes. Both hardware and software have been augmented and changed during the course of the Landsat TM developments to achieve improved geometric accuracy. An investigation has been conducted to determine if the TM meets the National Map Accuracy Standards for geometric accuracy at larger scales. It was found that TM imagery, in terms of geometry, has come close to, and in some cases exceeded, its stringent specifications.

Bryant, N. A.↗

Automated Pneumothorax Diagnosis using Deep Neural Networks

Thoracic ultrasound can provide information leading to rapid diagnosis of pneumothorax with improved accuracy over the standard physical examination and with higher sensitivity than anteroposterior chest radiography. However, the clinical We have Furthermore, remote environments, such as the battlefield or deep-space exploration, may lack expertise for diagnosing developed an automated image interpretation pipeline for the analysis of thoracic ultrasound data and the classification of pneumothorax events to provide decision support in such situations. Our pipeline consists of image preprocessing, data augmentation, and deep learning architectures for medical diagnosis. In this work, we demonstrate that robust, accurate interpretation of chest images and video can be achieved using deep neural networks. A number of novel image processing techniques were employed to achieve this result. Affine transformations were applied for data augmentation. Hyperparameters were optimized for learning rate, dropout regularization, batch size, and epoch iteration by a sequential model-based Bayesian approach. In addition, we utilized pretrained architecturesinterpretation of a patient medical image is highly operator dependent. certain pathologies., applying transfer learning and fine-tuning techniques to fully connected layers. Our pipeline yielded binary classification validation accuracies of 98.3% for M-mode images and 99.8% with B-mode video frames.

US Army collaboration↗

Research in computational fluid dynamics and analysis of algorithms

Recently, higher-order compact schemes have seen increasing use in the DNS (Direct Numerical Simulations) of the Navier-Stokes equations. Although they do not have the spatial resolution of spectral methods, they offer significant increases in accuracy over conventional second order methods. They can be used on any smooth grid, and do not have an overly restrictive CFL dependence as compared with the O(N(exp -2)) CFL dependence observed in Chebyshev spectral methods on finite domains. In addition, they are generally more robust and less costly than spectral methods. The issue of the relative cost of higher-order schemes (accuracy weighted against physical and numerical cost) is a far more complex issue, depending ultimately on what features of the solution are sought and how accurately they must be resolved. In any event, the further development of the underlying stability theory of these schemes is important. The approach of devising suitable boundary clusters and then testing them with various stability techniques (such as finding the norm) is entirely the wrong approach when dealing with high-order methods. Very seldom are high-order boundary closures stable, making them difficult to isolate. An alternative approach is to begin with a norm which satisfies all the stability criteria for the hyperbolic system, and look for the boundary closure forms which will match the norm exactly. This method was used recently by Strand to isolate stable boundary closure schemes for the explicit central fourth- and sixth-order schemes. The norm used was an energy norm mimicking the norm for the differential equations. Further research should be devoted to BC for high order schemes in order to make sure that the results obtained are reliable. The compact fourth order and sixth order finite difference scheme had been incorporated into a code to simulate flow past circular cylinders. This code will serve as a verification of the full spectral codes. A detailed stability analysis by Carpenter (from the fluid Mechanics Division) and Gottlieb gave analytic conditions for stability as well as asymptotic stability. This had been incorporated in the code in form of stable boundary conditions. Effects of the cylinder rotations had been studied. The results differ from the known theoretical results. We are in the middle of analyzing the results. A detailed analysis of the effects of the heating of the cylinder on the shedding frequency had been studied using the above schemes. It has been found that the shedding frequency decreases when the wire was heated. Experimental work is being carried out to affirm this result.

Gottlieb, David↗