Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large ordered moment with strong easy-plane anisotropy and vortex-domain pattern in the kagome ferromagnet Fe 3 Sn

We report the magnetic anisotropy of kagome bilayer ferromagnet Fe 3 Sn probed by the bulk magnetometry and magnetic force microscopy (MFM) on high-quality single crystals. The dependence of magnetization on the orientation of the external magnetic field reveals strong easyplane magnetocrystalline anisotropy and anisotropy of the saturation magnetization. The leading magnetocrystalline anisotropy constant shows a monotonous increase from $\mathrm{K_1$≈ –1.0 \times 10^6 J/m^3}$ at 300 K to $\mathrm{–1.3 \times 10^6 J/m^3}$ at 2 K. Our ab initio electronic structure calculations yield the value of total magnetic moment of 7.1$μ_Β$/$f.u.$ and a magnetocrystalline anisotropy energy density of –0.57 $\mathrm{meV/}$$f.u.$ $\mathrm{(–1.62 \times 10^6J/m^3)}$ both being in reasonable agreement with the experimental values. The MFM imaging reveals micrometer-scale magnetic vortices with weakly pinned cores that vanish at the saturation field of ~3T applied perpendicular to the kagome plane. The observed vortex-domain structure is well reproduced by the micromagnetic simulations, using the experimentally determined value of the anisotropy and exchange stiffness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-DE-207A-05: Dictionary Learning Based Reconstruction with Low-Rank Constraint for Low-Dose Spectral CT

Purpose: Spectral CT enabled by an energy-resolved photon-counting detector outperforms conventional CT in terms of material discrimination, contrast resolution, etc. One reconstruction method for spectral CT is to generate a color image from a reconstructed component in each energy channel. However, given the radiation dose, the number of photons in each channel is limited, which will result in strong noise in each channel and affect the final color reconstruction. Here we propose a novel dictionary learning method for spectral CT that combines dictionary-based sparse representation method and the patch based low-rank constraint to simultaneously improve the reconstruction in each channel and to address the inter-channel correlations to further improve the reconstruction. Methods: The proposed method has two important features: (1) guarantee of the patch based sparsity in each energy channel, which is the result of the dictionary based sparse representation constraint; (2) the explicit consideration of the correlations among different energy channels, which is realized by patch-by-patch nuclear norm-based low-rank constraint. For each channel, the dictionary consists of two sub-dictionaries. One is learned from the average of the images in all energy channels, and the other is learned from the average of the images in all energy channels except the current channel. With average operation to reduce noise, these two dictionaries can effectively preserve the structural details and get rid of artifacts caused by noise. Combining them together can express all structural information in current channel. Results: Dictionary learning based methods can obtain better results than FBP and the TV-based method. With low-rank constraint, the image quality can be further improved in the channel with more noise. The final color result by the proposed method has the best visual quality. Conclusion: The proposed method can effectively improve the image quality of low-dose spectral CT. This work is partially supported by the National Natural Science Foundation of China (No. 61302136), and the Natural Science Basic Research Plan in Shaanxi Province of China (No. 2014JQ8317).

60 APPLIED LIFE SCIENCES↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Effects of sintering aid CuTa{sub 2}O{sub 6} on piezoelectric and dielectric properties of sodium potassium niobate ceramics

Graphical abstract: NKN ceramics with a sintering aid CuTa{sub 2}O{sub 6} (CT) doping increased the mechanical quality factor (Q{sub m}) and electromechanical coupling factor (k{sub p}). Highlights: Black-Right-Pointing-Pointer A new sintering aid CuTa{sub 2}O{sub 6} was developed to dope into NKN ceramics. Black-Right-Pointing-Pointer Dense NKN ceramics were obtained as CuTa{sub 2}O{sub 6} compound doping. Black-Right-Pointing-Pointer We find the soluble limit of CuTa{sub 2}O{sub 6} compound incorporated into NKN ceramics. Black-Right-Pointing-Pointer The maximum Q{sub m} and k{sub p} values were more than 1500 and 42%, respectively. Black-Right-Pointing-Pointer CuTa{sub 2}O{sub 6} compound is a better sintering aid compared with K{sub 5.3}Cu{sub 1.3}Ta{sub 10}O{sub 29}. -- Abstract: In this study, the effects of a sintering aid CuTa{sub 2}O{sub 6} (CT) on (Na{sub 0.5}K{sub 0.5})NbO{sub 3} (NKN) ceramics were investigated. The diffracted angles in XRD profiles decreased because the Nb-sites were replaced by Cu and Ta ions, causing the expansion of lattice volume. SEM images showed smaller grain sizes at a low concentration of CuTa{sub 2}O{sub 6}, and grain sizes increased as the concentration of CuTa{sub 2}O{sub 6} doping increased because of a liquid phase formed. When CuTa{sub 2}O{sub 6} dopants were doped into NKN ceramics, the T{sub O-T} and T{sub c} phase transitions decreased because the replacement of Ta{sup 5+} ions in the B-site. A high bulk density (4.595 g/cm{sup 3}) and electromechanical coupling factor (k{sub p}, k{sub t}) were enhanced when CT dopants were doped into NKN ceramics. Moreover, the mechanical quality factor (Q{sub m}) also increased from 67 to 1550. NKN ceramics with sintering aid CuTa{sub 2}O{sub 6} doping showed excellent piezoelectric properties: k{sub p}: 42.5%; k{sub t}: 49.1%; Q{sub m}: 1550; and d{sub 33}: 96 pC/N.

36 MATERIALS SCIENCE↗

Growth and characterization of single phase Cu{sub 2}O by thermal oxidation of thin copper films

We report a simple and efficient technique to form high quality single phase cuprous oxide films on glass substrate using thermal evaporation of thin copper films followed by controlled thermal oxidation in air ambient. Crystallographic analysis and oxide phase determination, as well as grain size distribution have been studied using X-ray diffraction (XRD) method, while scanning electron microscopy (SEM) has been utilized to investigate the surface morphology of the as grown oxide films. The formation of various copper oxide phases is found to be highly sensitive to the oxidation temperature and a crystalline, single phase cuprous oxide film can be achieved for oxidation temperatures between 250°C to 320°C. Cu{sub 2}O film surface appeared in a faceted morphology in SEM imaging and a direct band gap of about 2.1 eV has been observed in UV-visible spectroscopy. X-ray photoelectron spectroscopy (XPS) confirmed a single oxide phase formation. Finally, a growth mechanism of the oxide film has also been discussed.

36 MATERIALS SCIENCE↗

Evidence of Radiosensitizing Effects of GdPO{sub 4} Nanostructures

Developing new methods to improve the outcome of cancer treatment has been one of the main research areas in medicine. Many approaches that allow for tumor targeting and thus reduction of side effects are currently under investigation. Among those, the combination of radiation therapy with certain chemotherapeutic agents has shown significant advances in cancer treatment. Another option is the use of radiosensitizers along with radiation therapy. Radiosensitizers are materials intended to enhance the radiation dose received in the tumor while maintaining the damage to the normal tissue to a minimum. Hence, the development of radiosensitizers has been of interest in recent years in order to improve the survival rate and the quality of life of the patient while reducing the cost of treatment. In this area, nanoparticles (NPs) have been widely explored as radiosensitizers due to the fact that tumor targeting can be achieved and the concentration of NPs on tumor environments can be greatly enhanced through the modification of NPs' surface by addition of agents such as antibodies. More importantly, the chemical composition of the NPs can be adjusted based on the application of interest. In this context, NPs that contain heavy elements have great potential as radiosensitizers due to their mechanisms of interaction with X-rays. For instance, gold NPs have been recognized as radiosensitizers due to their large photoelectric absorption coefficient. Furthermore, lanthanide based NPs have also shown characteristics as radiosensitizers. Among the various lanthanide containing NPs, gadolinium-based nanomaterials (NMs) have shown great potential for multiple applications in medicine such as contrast agents for magnetic resonance imaging (MRI). Additionally, the combination of gadolinium-based NPs and irradiation has evidenced a significant dose enhancement in in-vivo testing. Moreover, gadolinium-based ultra-small rigid platforms (USRPs) have shown theranostic properties for multimodal detection of lung cancers and radiosensitization effects. Among the various Gd based NPs, GdPO{sub 4} NMs are of increasing interest due to the multiple functions and applications that they may have. To illustrate, GdPO{sub 4} NPs have evidenced relaxitivities that are comparable to the contrast agents commonly used in MRI. Moreover, these NPs can be doped with different lanthanides ions allowing for the implementation of MRI and cellular luminescence for diagnostic purposes. Furthermore, gold-coated gadolinium-lanthanum phosphate NPs have evidenced their ability to encapsulate alpha-emitting radioisotopes of radiotherapeutic interest. This allows for targeted internal radiotherapy by functionalizing the NPs with specific molecules Moreover, low toxicity has been observed on dextran coated GdPO{sub 4} NPs regardless of the potential toxicity of free Gd{sup 3+}. Despite the various applications of GdPO{sub 4}, its response and interaction with X-ray evaluating their potential as radiosensitizers has not been explored. In this work, the radiosensitization of GdPO{sub 4} NMs is evidenced through the decomposition of a dye, methylene blue (MB), after X-ray radiation in the presence of NMs. GdPO{sub 4} was synthesized at moderate temperature following a hydrothermal method based on the precipitation reaction of a salt precursor and a surfactant. The crystalline structure and morphology of these NMs were characterized using Xray diffraction (XRD) and transmission electron microscopy (TEM). Crystalline GdPO{sub 4} was obtained following the hydrothermal synthesis. Besides, it was observed that the addition of GdPO{sub 4} to the MB solution enhances the decomposition of this dye under X-ray radiation. Therefore, GdPO{sub 4} NMs prove to be promising as radiosensitizers in radiation therapy. Nevertheless, the effect of GdPO{sub 4} on MB decomposition under X-ray radiation requires further study to evaluate the effect of the morphology and concentration of GdPO{sub 4} and the dose effect. (authors)

36 MATERIALS SCIENCE↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Growth of Ca{sub 2}MnO{sub 4} Ruddlesden-Popper structured thin films using combinatorial substrate epitaxy

The local epitaxial growth of pulsed laser deposited Ca{sub 2}MnO{sub 4} films on polycrystalline spark plasma sintered Sr{sub 2}TiO{sub 4} substrates was investigated to determine phase formation and preferred epitaxial orientation relationships (ORs) for isostructural Ruddlesden-Popper (RP) heteroepitaxy, further developing the high-throughput synthetic approach called Combinatorial Substrate Epitaxy (CSE). Both grazing incidence X-ray diffraction and electron backscatter diffraction patterns of the film and substrate were indexable as single-phase RP-structured compounds. The optimal growth temperature (between 650 °C and 800 °C) was found to be 750 °C using the maximum value of the average image quality of the backscattered diffraction patterns. Films grew in a grain-over-grain pattern such that each Ca{sub 2}MnO{sub 4} grain had a single OR with the Sr{sub 2}TiO{sub 4} grain on which it grew. Three primary ORs described 47 out of 49 grain pairs that covered nearly all of RP orientation space. The first OR, found for 20 of the 49, was the expected RP unit-cell over RP unit-cell OR, expressed as [100][001]{sub film}||[100][001]{sub sub}. The other two ORs were essentially rotated from the first by 90°, with one (observed for 17 of 49 pairs) being rotated about the [100] and the other (observed for 10 of 49 pairs) being rotated about the [110] (and not exactly by 90°). These results indicate that only a small number of ORs are needed to describe isostructural RP heteroepitaxy and further demonstrate the potential of CSE in the design and growth of a wide range of complex functional oxides.

36 MATERIALS SCIENCE↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

In situ X-ray imaging of pore formation mechanisms and dynamics in laser powder-blown directed energy deposition additive manufacturing

Directed energy deposition (DED) additive manufacturing (AM) is receiving growing attention in many applications, such as repair, remanufacturing, and fabrication of functionally graded structures. However, the laser-matter interactions and melt pool dynamics in laser DED with powder flow are still unclear, particularly in how pores form and flow inside the melt pool during the process. Understanding the porosity formation mechanisms is critical in the qualification, certification, and overall properties of a DED AM part. Porosity is a common phenomenon and can significantly hinder the quality of DED fabricated parts, as the pores can act as sites of crack nucleation and propagation. Here in this paper, we reveal four types of pore formation mechanisms through in-situ and operando high-speed high-resolution X-ray imaging in the DED AM process. Our results confirm that porosity within the feedstock powder induces pores in the process. We also observed pore formation mechanisms unique to the laser-based, powder-blown DED process as a result of powder delivery, keyhole dynamics, melt pool dynamics, and shield gas. High-speed X-ray images provide direct evidence for pore formation mechanisms and show that the pores related to the interaction between the delivered powder and melt pool are the largest in size in laser-based powder-blown DED AM. These results will guide porosity mitigation, elimination, and control in DED AM.

36 MATERIALS SCIENCE↗

Effect of Ti seed layers on structure of self-organized epitaxial face-centered-cubic-Ag(001) oriented nanodots

The influence of Ti seed layers on the structure of self-organized Ag nanodots, obtained with a Ti seed-layer-assisted thermal agglomeration method, has been investigated. The samples were grown on MgO(001) single crystal substrates by RF magnetron sputter deposition. The samples were deposited at room temperature and post-annealed at 350 °C for 4 h while maintaining the chamber vacuum conditions. The results of atomic force microscopy (AFM) observations indicated that the insertion of the Ti seed layer (0.6–5.0 nm) between the MgO substrate and Ag layer promotes the agglomeration process, forming the nanodot array. Comparisons between the AFM images revealed that the size of the Ag nanodots was increased with an increase in the Ti seed layer thickness. The atomic concentration of the film surface was confirmed by X-ray photoelectron spectroscopy (XPS). The XPS result suggested that the nanodot surface mainly consisted of Ag. Moreover, X-ray diffraction results proved that the initial deposition of the Ti seed layer (0.6–5.0 nm) onto MgO(001) prior to the Ag deposition yielded high-quality fcc-Ag(001) oriented epitaxial nanodots. The optical absorbance spectra of the fabricated Ag nanodots with various Ti seed layer thicknesses were obtained in the visible light range.

36 MATERIALS SCIENCE↗

Temperature-dependent structure of Tb-doped magnetite nanoparticles

High quality 5 nm cubic Tb-doped magnetite nanoparticles have been synthesized by a wet-chemical method to investigate tailoring of magnetic properties for imaging and biomedical applications. We show that the Tb is incorporated into the octahedral 3+ sites. High-angle annular dark-field microscopy shows that the dopant is well-distributed throughout the particle, and x-ray diffraction measurements show a small lattice parameter shift with the inclusion of a rare-earth dopant. Magnetization and x-ray magnetic circular dichroism data indicate that the Tb spins are unpolarized and weakly coupled to the iron spin lattice at room temperature, and begin to polarize and couple to the iron oxide lattice at temperatures below 50 K. Broadband ferromagnetic resonance measurements show no increase in magnetic damping at room temperature for Tb-doped nanoparticles relative to undoped nanoparticles, further confirming weak coupling between Fe and Tb spins at room temperature. The Gilbert damping constant, α, is remarkably low for the Tb-doped nanoparticles, with α = 0.024 ± 0.003. These nanoparticles, which have a large fixed moment, a large fluctuating moment and optically active rare-earth elements, are potential high-relaxivity T1 and T2 MRI agents with integrated optical signatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mapping Benthic Habitat Conditions and Seafloor Deposits using Sediment Profile Imaging and a Semiautomated Image Processing System

Objectives/Scope: Sediment profile imaging (SPI) technology characterizes in situ physical, geochemical, and biological seafloor features. SPI was required by Mexico’s Agency for Safety, Energy, and Environment in 2017 for environmental baseline surveys (EBS) of oil lease blocks in the southern Gulf of Mexico. Because of its ability to provide information on benthic community health and the distribution of very thin (down to the centimeter scale) layers of deposited materials, SPI technology is highly effective for mapping drill cuttings or drilling muds released around wellheads during exploration or production and documenting their ecological impacts. SPI technology has not been widely used in the oil and gas industry for EBS or other monitoring activities. A primary objective of this work is to improve the transparency and consistency of the SPI data generation and data management process. Methods, Procedures, Process: The SPI camera works like an inverted periscope and obtains an undisturbed 21x15-cm cross-sectional image of the upper sediment column. The camera is internally powered and can be deployed rapidly from a standard winch in depths to 4,000 m. Many stations can be sampled in a single day by “pogo-sticking” across a survey area. Sediment grain size, penetration depth, surface boundary roughness, natural and anthropogenic depositional layers, depth of the oxidized surface sediment layer, maximum biogenic mixing depth, and infaunal successional stage can be directly measured at sea or immediately following the cruise. Final SPI data sets can be provided within a few weeks of the survey. Results, Observations, Conclusions: Details on the features measured in SPI images and the underlying interpretive paradigms are presented. To standardize the SPI data generation process, Integral Consulting Inc. has developed 1) a semiautomated image analysis platform, and 2) a SPI data-specific database architecture that allows both numerical and non-numerical metrics to be incorporated into a standard database structure. An integrated, software-based SPI analysis platform has been developed that imports image files and metadata and provides a graphical user interface. The software automatically stores the data, which can then be reviewed for quality assurance, plotted, statistically analyzed, and mapped or exported to other platforms (e.g., Esri ArcGIS©) for further evaluation. Image processing algorithms have been developed using a combination of open-source and commercially available software packages (e.g., MATLAB® and OpenCV) to automatically quantify key parameters. Novel/Additive Information: SPI technology’s underutilization in the oil and gas industry may be in part due to a lack of standardization in the measurement of basic features in SPI images. A primary objective of this work is to develop a streamlined, standardized, and transparent process for generating and managing SPI data.

02 PETROLEUM↗

Ultra-High-Performance Concrete And Advanced Manufacturing Methods For Modular Construction

Small modular reactors (SMR) allow for less onsite construction, increase nuclear material security, and provide a flexible and cost-effective energy alternative. SMR can be factory-built as modular components, and shipped to desired locations for fast assembly. This project successfully developed a new class of ultra-high performance concrete (UHPC), which features a compressive strength greater than 22 ksi (150 MPa) without special treatment and self-consolidating characteristics desired for SMR modular construction. With an ultra-high strength and dense microstructure, it will facilitate rapid construction of steel plate-concrete (SC) beams and walls with thinner and lighter modules, and can withstand harsh environments and mechanical loads anticipated during the service life of nuclear power plants. In addition, the self-consolidating characteristics are crucial for the fast construction and assembly of SC modules with reduced labor costs and improved quality. Following the UHPC material development, the capacity of producing self-consolidating UHPC in mass quantities was investigated and compared to accepted self-consolidating concrete standards. With slightly adjusted mixing procedure using large-scale gravity-based mixers (compared with small-scale force-based mixer), the self-consolidating UHPC has been successfully processed at six cubic yards; the product met both minimum compressive strength requirements and self-consolidating concrete standards. Steel plate-UHPC beams (15 ft. long, 12 in. wide and 16 in. deep) and wall panels (40 in. X 40 in. X 3 in.) were then constructed using the self-consolidating UHPC without any external vibration. Quality control guidelines for producing UHPC in large scale were developed. When the concrete is replaced by UHPC in a steel plate concrete (SC) beam, it is critical to evaluate its structural behavior with both flexure and shear-governed failure modes. In recent years, SC has been widely used for buildings and nuclear containment structures to resist lateral forces induced by severe earthquakes and heavy winds. SC modules have good potential for SMR because of their cost-effectiveness and reduced construction time. However, the minimum shear reinforcement (i.e. cross tie) ratio needs to be determined for the steel plate-UHPC (S-UHPC) beams to exhibit a ductile failure mode. In this project, S-UHPC beams were designed and constructed. The beams were tested to evaluate structural capacity and identify the minimum cross ties ratios. In addition, as the bond between UHPC and steel plate is essential for ensuring structural integrity under shear and flexure, it was measured and examined in this project through digital image correlation system and smart piezoelectric aggregate sensors. Large-scale testing and finite element simulation were also performed on S-UHPC wall panels. New bond slip-based constitutive models of steel plate were developed for S-UHPC, which were used in finite element analysis program to predict S-UHPC behavior under shear. The results were well validated through experimental data. The long-term durability of UHPC were established in this project. UHPC specimens were tested under free shrinkage, restrained shrinkage, elevated temperature, water permeation, chloride diffusion, corrosion, and alkali silica reaction. UHPC has demonstrated significantly improved durability compared with control concrete specimens. This research led to a new generation of steel plate-UHPC modules for SMR that can provide large benefits to the electric power industry. Taking advantage of the high strength and durability of UHPC, their modularity and ease of assembly can address the high cost barriers of typical nuclear power plants.

42 ENGINEERING↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗