Elementally Resolved Dissolution Kinetics of a Ni-Fe-Cr-Mn-Co Multi-Principal Element Alloy in Sulfuric Acid Using AESEC-EIS

Atomic emission spectroelectrochemistry (AESEC) combined with linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS) provided insights on both active and passive dissolution of Ni-Fe-Cr-Mn-Co multi-principal element alloy. Elemental dissolution rates measured by AESEC during open circuit experiment were in agreement with those extrapolated from AESEC-LSV and indicated element-specific dissolution tendencies. AESEC-EIS at open circuit potential showed nearly in-phase elemental dissolution during potential modulation which suggests direct dissolution from the alloy surface to the electrolyte. In the passive potential domain, no oscillation of the elemental dissolution rate was detected by AESEC-EIS, suggesting non-oxidative chemical dissolution of the outer layer of the passive film. In this case, dissolution at the passive film/electrolyte interface was equal to the metal oxidation rate (passive current density) at the metal/passive film interface and the passive current density was independent of potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗

Electrode Blocking Due to Redox Reactions in Aluminum Chloride-Sodium Iodide Molten Salts

Iodide redox reactions in molten NaI/AlCl 3 are shown to generate surface-blocking films, which may limit the useful cycling rates and energy densities of molten sodium batteries below 150 °C. An experimental investigation of electrode interfacial stability at 110 °C reveals the source of the reaction rate limitations. Electrochemical experiments in a 3-electrode configuration confirm an increase of resistance on the electrode surface after oxidation or reduction current is passed. Using chronopotentiometry, chronoamperometry, cyclic voltammetry, and electrochemical impedance spectroscopy, the film formation is shown to depend on the electrode material (W, Mo, Ta, or glassy carbon), as well as the Lewis acidity and molar ratio of I − /I 3 − in the molten salt electrolytes. These factors impact the amount of charge that can be passed at a given current density prior to developing excessive overpotential due to film formation that blocks the electrode surface. The results presented here guide the design and use of iodide-based molten salt electrolytes and electrode materials for grid scale battery applications.

25 ENERGY STORAGE↗

The Effects of Lithium Ions and pH on the Function of Polyacrylic Acid Binder for Silicon Anodes

Binder plays a critical role in the performance of silicon anodes for lithium-ion batteries, specifically by connecting particles of active material and promoting adhesion to the current collector. Recent studies have differed on the relative cycle life of silicon anodes made from water-based polyacrylic acid (PAA) vs LiOH-PAA binders. Differences between the two may be due to the pH value or the extra Li + in the binder, both of which change when LiOH is added to PAA. Here we investigate the impact of these two variables on the performance of silicon anodes. Regarding the effect of Li + , cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) results confirm our hypothesis that the extra Li + facilitates ion transport. Regarding pH, we find that high pH in binders is detrimental to the electrode mechanical integrity, as observed in peeling tests and cross-sectional imaging. However, viscosity tests reveal that increased pH benefits the coating and mixing process. Further, our cycling results show that LiOH-PAA binder maintains greater cell capacity than does PAA, and further that LiOH-PAA at pH 4.5 leads to a cell with the highest capacity. Therefore, an intermediate pH is an optimal compromise between benefits observed for the low and high pH experiments.

25 ENERGY STORAGE↗

Revealing the Electrochemical Kinetics of Electrolytes in Nanosized LiFePO 4 Electrodes

Lithium-ion battery rate performance is ultimately limited by the electrolyte, yet the behaviors of electrolytes during high-rate (dis)charge remain elusive to electrochemical measurement. Herein, we develop and study a nanosized LiFePO 4 model system in which the electrolyte completely controls the electrochemical kinetics of the porous electrode. Impedance spectroscopy, cyclic voltammetry, and rate performance testing prove that ion transport in the electrolyte is the sole rate-limiting process, even in thin electrodes. A novel pseudo-steady-state extrapolation (S3E) method for Tafel analysis shows that LiFePO 4 obeys Butler-Volmer kinetics with a transfer coefficient of 3. The combination of these unexpectedly rapid interfacial kinetics and an activation barrier for phase transformation causes extreme reaction heterogeneity, which manifests as a moving reaction zone. Resistance versus capacity analysis enables direct measurement of electrolyte resistance growth during high-rate (dis)charge, revealing how the interaction between concentration polarization and a moving reaction zone controls electrolyte rate performance in LiFePO 4 electrodes. This work elucidates the profound impacts of the electrolyte on electrochemical measurements in porous battery electrodes: when the active material is not rate limiting, it is impossible to directly measure the intrinsic kinetics of the active material, but conversely, it becomes possible to directly measure the kinetics of the electrolyte.

Electrochemistry↗

Exploring the Effectiveness of Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) have shown to be a promising technology for integrating intermittent renewable energy sources into the existing electrical grid. Incorporation of carbon cloth electrodes into VRFB is an area of interest for their enhanced electrochemical performance, however, issues with performance degradation throughout the duration of the experiment persist. This study investigates the performance evolution of carbon cloth electrodes during VRFB cycling to build a hypothesis on possible reasons for the declining performance. Electrochemical impedance spectroscopy and polarization curve measurements are used in conjunction to monitor the electrode degradation and shed light on the effectiveness of carbon cloth electrodes during extended cycling experiments. A detailed investigation into the structure of the carbon cloth electrodes before and after cycling, via several material characterization tests, provides insight needed to determine an explanation for the increasing resistance. The structural integrity and surface morphology of the carbon cloth electrodes are evaluated to compare the electrode before and after cycling, displaying any changes to the electrode due to cycling. Durability of hydrophilicity during RFB cycling is found to be a key feature for future carbon cloth electrode design efforts.

25 ENERGY STORAGE↗

Effect of V Content on Corrosion Behavior of Al-V Alloys Produced by Mechanical Alloying and Subsequent Spark Plasma Sintering

Al-V alloys produced via high-energy ball milling have been reported to show simultaneous improvement of corrosion resistance and mechanical properties compared to traditional Al alloys. In these alloys, V content plays a crucial role in increasing or decreasing the corrosion resistance. Therefore, the effect of V and microstructure on corrosion of high-energy ball milled and subsequently spark plasma sintered Al-xV alloys (x = 2, 5, 10 at%) has been studied. Cyclic potentiodynamic polarization tests and electrochemical impedance spectroscopic analysis revealed the increment of V content up to 5 at% enhanced the corrosion resistance of the alloy. However, highly heterogeneous microstructure in Al-10 at%V resulted in significant localized corrosion over the immersion time. The electrochemical impedance spectroscopy studies over 14 days of immersion revealed underlying corrosion mechanisms.

36 MATERIALS SCIENCE↗

Predicting the Rate of Degradation Related to Oxygen Electrode Delamination in Solid Oxide-Ion Electrolyzers

One of the leading causes for the performance degradation in H 2 -producing solid oxide electrolytic cells (SOECs) is the gradual delamination of oxygen electrode (OE) from the electrolyte under a strong anodic polarization. Identification of the key factor that controls the rate of OE delamination is of paramount importance to achieve long-term stable operation of SOECs. Here we show from thousands of hours of testing data that the exchange current density (i°) of OE can be leveraged as a predictor for the rate of delamination. To obtain i°, we apply DC-biased electrochemical impedance spectroscopy on a three-electrode symmetrical cell to measure polarization resistance (R p ) of OE as a function of current density (i) and time (t). The collected R p -i-t raw data are then converted to overpotential ( η )-i-t, from which i° is extracted from the “low-field” approximation. An analytical relationship between i° and time-to-delamination (TTD) is further established from the established i°-i-t relationship. We show that under a constant anodic polarization current density i, the greater the ratio i/i°, the faster the delamination. Therefore, we conclude that the exchange current density of an OE, i°, can be used to predict the rate of OE degradation in solid oxide-ion electrolyzers.

25 ENERGY STORAGE↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

Stability of a Ni/NiF 2 Reference Electrode with a Metallic Membrane for Use in Molten Fluoride Salts

In this study, an experimental high-temperature fluoride salt reference electrode (RE) developed by HiFunda LLC was tested in molten FLiNaK at 550 °C. The high-temperature reference electrode (HTRE), based on the Ni/NiF 2 redox couple, was tested over a period of 13 d for short-term stability, long-term stability, and electrochemical analysis capabilities. The HTRE was tested using open circuit potentiometry (OCP), cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS). The HTRE reference potential was measured against changes in salt composition by increasing FeF 2 concentrations in the melt across six additions from 0 to 0.1 mol% FeF 2 . The long-term stability of the electrode was then tested over ten days at a constant composition of 0.1 mol% FeF 2 . OCP, SWV, and CV were used to calculate an average potential drift between 7–10 mV per day. Using CV and SWV, the number of electrons transferred for iron reduction and the diffusion coefficient of Fe 2+ were measured.

Electrochemistry↗

Capacity Fade of Graphite/NMC811: Influence of Particle Morphology, Electrolyte, and Charge Voltage

LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) is an important Li-ion battery cathode material; however, there is a tradeoff between delivered capacity and capacity retention. As the charge potential increases the capacity rises but at the expense of capacity retention. The decrease in capacity retention has been ascribed to several factors including particle cracking, surface reconstruction, transition metal dissolution, and electrolyte reactivity. The present study compares 4.1 and 4.3 V charging limits in commercially relevant graphite/NMC811 pouch cells for single crystal (SC) and polycrystalline (PC) NMC811 with ethylene carbonate (EC)-containing or EC-free electrolytes. The electrochemistry is rationalized through analysis of electrochemical impedance spectroscopy, positive electrode X-ray photoelectron spectroscopy, soft X-ray absorption spectroscopy, X-ray diffraction, and negative electrode mapping by X-ray fluorescence. Graphite/SC-NMC811 cells show high-capacity retention at 4.1 V but exhibit degradation at 4.3 V charging potentials. The EC-free electrolyte cells led to higher capacity fade, especially when charged to 4.3 V. Cathode dissolution and deposition on the negative electrode from PC-NMC811 cells was higher than for samples from SC-NMC811 cells. This study reveals the impact of material type, charge voltage, and electrolyte composition on the reactions at the positive electrode, their influence on the negative electrode, and evolution with cycle number.

36 MATERIALS SCIENCE↗

Binder-Coated Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) are a promising solution for integrating intermittent renewable energy sources into the existing power grid. However, enhancing the electrochemical performance of VRFBs is critical for their widespread adoption in grid-scale energy storage. This study investigates the impact of adding a porous binder to a carbon-cloth electrode, with a focus on optimizing thermal activation conditions. The electrochemical performance of the binder-coated electrodes compared to uncoated electrodes is evaluated through electrochemical impedance spectroscopy, polarization curve measurements, and charge-discharge cycling. The surface morphology and structural integrity of the binder-coated electrodes at each activation stage are examined using various material characterization techniques to assess the effects of thermal activation. The results are benchmarked against the experiments using non-coated electrodes to determine the performance improvements offered by the binder coating. Notably, the study reveals that binder-coated electrodes exhibit significantly lower resistance and improved efficiency compared to their uncoated counterparts, with optimal activation conditions enhancing performance metrics crucial for VRFB applications. These findings provide valuable insights for further optimizing electrode design and activation strategies, advancing the development of more efficient VRFB systems for large-scale energy storage.

Caiado, Ashley A.↗

Methods for Rotating Electrodes in High-Temperature Molten Salts

Abstract In this paper, we describe and validate a custom apparatus for performing high-speed (250-3,500 rpm) rotating electrode and dilatometer density experiments in molten salts. The reported details can aid in decreasing the difficulty and increasing the quality of such experiments. We discuss the design challenges and the solutions identified. We investigate methods for accurately measuring the solution resistance using electrochemical impedance spectroscopy, calculating the working electrode area using cyclic voltammetry, and measuring the mass transfer-limited current of rotating electrodes using a series of chronoamperometry pulses. We further demonstrate the efficacy of our methods in producing accurate results.

Fuller, Ranon (ORCID:0000000255400197)↗

Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis

Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.

08 HYDROGEN↗

Searching for a Pulse: Evaluating the Use of Rapid DC Pulses for Diagnosing Battery Health, State-of-Charge, and Safety

Rapid electrochemical diagnostics, like DC pulse sequences or electrochemical impedance spectroscopy, are known to be useful for capacity prediction. However, it is unclear how previous results will map to different cell types and use cases and whether rapid diagnostics are useful for remaining useful life prediction or for detecting potential safety issues. To that end, we have collected a data set with ∼50,000 DC pulse measurements from four types of commercial lithium-ion batteries to enable training of state-of-charge, health, and safety diagnostic models via machine-learning. We demonstrate that 120-second DC pulse sequences can be used to predict capacity with 2%–9% average error, which can separate high- from low-capacity cells with only a 0.3% false positive rate but is not accurate enough to estimate remaining useful life. We also find that no safety related targets can be accurately predicted, highlighting the critical need for other non-invasive methods to diagnose battery safety.

25 ENERGY STORAGE↗

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗

Effect of Soluble Corrosion Products on Electrical Double Layer in LiCl-KCl Molten Salts

Corrosion in molten salts greatly hampers the application for renewable energy applications like molten salt reactors. To develop effective strategies for corrosion mitigation, understanding the interfacial structures and properties such as specific ion adsorption and electrical double layer capacitance are crucial. Using cyclic voltammetry and electrochemical impedance spectroscopy, we systematically studied the interfaces on various model electrodes including W (solid), Bi (liquid), and the stainless steel 316 in LiCl-KCl eutectic molten salts with the addition of corrosion species CrCl 2 and FeCl 2 . Both Cr 2+ and Fe 2+ ions increased electrical double layer capacitance, with Cr 2+ showing specific adsorption behavior and shifting the potential of zero charge, while Fe 2+ had minimal effect on point of zero charge. Two-working electrode measurements revealed increasing open-circuit potential and electrical double layer capacitance during the exposure of stainless steel 316, indicating its progressive corrosion and ion accumulation at the interface. X-ray photoelectron spectroscopy and Raman confirmed Cr enrichment at the interface. This work highlights the strong correlation between electrical double layer behavior and corrosion dynamics in molten salts and suggests electrical double layer capacitance as a sensitive, in situ indicator for corrosion monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On Stability and Electrochemical Performance of 316 Stainless Steel in Wastewater: Implications for Resource Recovery

Electrochemical nutrient recovery systems rely on stable electrode materials capable of operating in chemically complex wastewater environments. We investigated corrosion resistance and interfacial electrochemical behavior of 316 stainless steel (SS316) in a synthetic wastewater matrix representative of centrate streams, a key knowledge gap in electrochemical phosphorus recovery. A comprehensive suite of electrochemical techniques (chronoamperometry, cyclic voltammetry, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS)) and surface characterization methods (scanning electron microscopy, X-ray diffraction) were employed. Results revealed that wastewater containing typical ionic constituents (such as PO 4 3- , NH 4 + , and divalent cations) exhibited enhanced cathodic activity and the formation of a more stable, protective surface film on SS316 that mitigated chloride-induced corrosion. In contrast, SS316 in the NaCl solution showed significant susceptibility to passive layer breakdown and localized corrosion. Time-resolved EIS further confirmed improved interfacial stability and restricted charge transfer in WW over time, in stark contrast to the progressive passive layer degradation in NaCl. Surface analyses corroborated these findings, showing limited surface attack in WW compared to distinct localized corrosion features in NaCl. These findings indicate that competing ionic species in WW effectively mitigate chloride aggressiveness, enhance SS316 stability, and demonstrate improved electrode longevity and reliability for sustainable wastewater-based electrochemical phosphorus recovery applications.

36 MATERIALS SCIENCE↗