Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Stratospheric composition balloon, aircraft and rocket-borne experiments, 28-30 September 1977 (systems, instruments, trajectories, supporting measurements)

The STRATCOM (STRATospheric COMposition) is a long term multipurpose program for integrated, correlated measurements of stratospheric parameters related to composition, thermodynamics, and radiative balance. Balloon 8-b, carrying a solar-pointing grating infrared spectrometer, two CO2 thermal emission radiometers and two in-situ air temperature sensors was launched at 1251 MST on 28 September 1977 to float at an altitude of 39 km from 1521 MST with the instruments making measurements at that altitude through the time of sunset at 1822 MST. Balloon 8-a lifted a payload consisting of four UV filter photometers, two UV spectrometers, two chemiluminescent ozonesondes, dasibi ozone monitor, 14 tube cryogenic sampler, two aluminum oxide H2O sensors, four air temperature sensors, atmospheric pressure sensor, infrared and visible pyranometers, downward-looking camera, blunt-kryton lamp-Gerdien condenser probe, three component anemometer, balloon apex-plate payload and three parachute-borne dropsondes.

Ballard, H. N.↗

Temperature Variations of Saturn Rings with Viewing Geometries from Prime to Equinox Cassini Missions

After more than six years in orbit around Saturn, the Cassini Composite Infrared Spectrometer (CIRS) has acquired an extensive set of measurements of Saturn's main rings (A, B, C and Cassini Division) in the thermal infrared. Temperatures were retrieved for the lit and unlit rings over a variety of ring geometries that include phase angle, solar and spacecraft elevations and local time. We show that some of these parameters (solar and spacecraft elevations, phase angle) play a role in the temperature variations in the first order, while the others (ring and particle local time) produced second order effects. The results of this comparison will be presented.

Saturn's rings↗

The Compositional Evolution of C/2012 S1 (ISON) from Ground-Based High-Resolution Infrared Spectroscopy as Part of a Worldwide Observing Campaign

Volatile production rates, relative abundances, rotational temperatures, and spatial distributions in the coma were measured in C/2012 S1 (ISON) using long-slit high-dispersion (lambda/delta lambda approximately 2.5 times 10 (sup 4)) infrared spectroscopy as part of a worldwide observing campaign. Spectra were obtained on Universal Time 2013 October 26 and 28 with NIRSPEC (Near Infrared Spectrometer) at the W.M. Keck Observatory, and Universal Time 2013 November 19 and 20 with CSHELL (Cryogenic Echelle Spectrograph) at the NASA IRTF (Infrared Telescope Facility). H2O was detected on all dates, with production rates increasing markedly from (8.7 plus or minus 1.5) times 10 (sup 27) molecules per second on October 26 (Heliocentric Distance = 1.12 Astronomical Units) to (3.7 plus or minus 0.4) times 10 (sup 29) molecules per second on November 20 (Heliocentric Distance = 0.43 Astronomical Units). Short-term variability of H2O production is also seen as observations on November 19 show an increase in H2O production rate of nearly a factor of two over a period of about 6 hours. C2H6, CH3OH and CH4 abundances in ISON (International Scientific Optical Network) are slightly depleted relative to H2O when compared to mean values for comets measured at infrared wavelengths. On the November dates, C2H2, HCN and OCS abundances relative to H2O appear to be within the range of mean values, whereas H2CO and NH3 were significantly enhanced. There is evidence that the abundances with respect to H2O increased for some species but not others between October 28 (Heliocentric Distance = 1.07 Astronomical Units) and November 19 (Heliocentric Distance = 0.46 Astronomical Units). The high mixing ratios of H2CO to CH3OH and C2H2 to C2H6 on November 19, and changes in the mixing ratios of some species with respect to H2O between October 28 to November 19, indicates compositional changes that may be the result of a transition from sampling radiation-processed outer layers in this dynamically new comet to sampling more pristine natal material as the outer processed layer was increasingly eroded and the thermal wave propagated into the nucleus as the comet approached perihelion for the first time. On November 19 and 20, the spatial distribution for dust appears asymmetric and enhanced in the antisolar direction, whereas spatial distributions for volatiles (excepting CN) appear symmetric with their peaks slightly offset in the sunward direction compared to the dust. Spatial distributions for H2O, HCN, C2H6, C2H2, and H2CO on November 19 show no definitive evidence for significant contributions from extended sources; however, broader spatial distributions for NH3 and OCS may be consistent with extended sources for these species. Abundances of HCN and C2H2 on November 19 and 20 are insufficient to account for reported abundances of CN and C2 in ISON near this time. Differences in HCN and CN spatial distributions are also consistent with HCN as only a minor source of CN in ISON on November 19 as the spatial distribution of CN in the coma suggests a dominant distributed source that is correlated with dust and not volatile release. The spatial distributions for NH3 and NH2 are similar, suggesting that NH3 is the primary source of NH2 with no evidence of a significant dust source of NH2; however, the higher production rates derived for NH3 compared to NH2 on November 19 and 20 remain unexplained. This suggests a more complete analysis that treats NH2 as a distributed source and accounts for its emission mechanism is needed for future work.

Russo, N. Dello↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Science Observations of Deep Space One

During the Deep Space One (DS1) primary mission, the spacecraft will fly by asteroid 1992 KD and possibly comet Borrelly. There are two technologies being validated on DS1 that will provide science observations of these targets, the Miniature Integrated Camera Spectrometer (MICAS) and the Plasma Experiment for Planetary Exploration (PEPE). MICAS encompasses a camera, an ultraviolet imaging spectrometer and an infrared imaging spectrometer. PEPE combines an ion and electron analyzer designed to determine the three-dimensional distribution of plasma over its field of view. MICAS includes two visible wavelength imaging channels, an ultraviolet imaging spectrometer, and an infrared imaging spectrometer all of which share a single 10-cm diameter telescope. Two types of visible wavelength detectors, both operating between about 500 and 1000 nm are used: a CCD with 13-microrad pixels and an 18-microrad-per-pixel, metal-on-silicon active pixel sensor (APS). Unlike the CCD the APS includes the timing and control electronics on the chip along with the detector. The UV spectrometer spans 80 to 185 nm with 0.64-nm spectral resolution and 316-microrad pixels. The IR spectrometer covers the range from 1200 to 2400 nm with 6.6-nm resolution and 54-microrad pixels PEPE includes a very low-power, low-mass micro-calorimeter to help understand plasma-surface interactions and a plasma analyzer to identify de individual molecules and atoms in the immediate vicinity of the spacecraft that have been eroded off the surface of asteroid 1992 KD. It employs common apertures with separate electrostatic energy analyzers. It measures electron and ion energies spanning a range of 3 eV to 30 keV, with a resolution of five percent. and measures ion mass from one to 135 atomic mass units with 5 percent resolution. It electrostatically sweeps its field of view both in elevation and azimuth. Both MICAS and PEPE represent a new direction for the evolution of science instruments for interplanetary spacecraft. These two instruments incorporate a large fraction of the capability of five instruments that had typically flown on NASA's deep space missions The Deep Space One science team acknowledges the support of Philip Varghese, David H. Lehman, Leslie Livesay, and Marc Rayman for providing invaluable assistance in making the science observations possible.

Nelson, Robert M.↗

Water Vapor on Titan: The Stratospheric Vertical Profile from Cassini/CIRS Infrared Spectra

Water vapor in Titan's middle atmosphere has previously been detected only by disk-average observations from the Infrared Space Observatory (Coustenis et al., 1998). We report here the successful detection of stratospheric water vapor using the Cassini Composite Infrared Spectrometer (CIRS, Flasar et al., 2004) following an earlier null result (de Kok et al., 2007a). CIRS senses water emissions in the far-infrared spectral region near 50 microns, which we have modeled using two independent radiative transfer and inversion codes (NEMESIS, Irwin et al 2008 and ART, Coustenis et al., 2010). From the analysis of nadir spectra we have derived a mixing ratio of (0.14 plus or minus 0.05) ppb at 100 km, corresponding to a column abundance of approximately (3.7 plus or minus 1.3) x 10(exp 14) moles per square centimeter. Using limb observations, we obtained mixing ratios of (0.13 plus or minus 0.04) ppb at 125 km and (0.45 plus or minus 0.15) ppb at 225 km of altitude, confirming that the water abundance has a positive vertical gradient as predicted by photochemical models. In the latitude range (80 deg. S - 30 deg. N) we see no evidence for latitudinal variations in these abundances within the error bars.

Cottini, V.↗

Initial Processing of Infrared Spectral Data

The Atmospheric Infrared Spectrometer (AIRS) Science Processing System is a collection of computer programs, denoted product generation executives (PGEs), for processing the readings of the AIRS suite of infrared and microwave instruments orbiting the Earth aboard NASA's Aqua spacecraft. Following from level 0 (representing raw AIRS data), the PGEs and their data products are denoted by alphanumeric labels (1A, 1B, and 2) that signify the successive stages of processing. Once level-0 data have been received, the level-1A PGEs begin processing, performing such basic housekeeping tasks as ensuring that all the Level-0 data are present and ordering the data according to observation times. The level-1A PGEs then perform geolocation-refinement calculations and conversions of raw data numbers to engineering units. Finally, the level-1A data are grouped into packages, denoted granules, each of which contain the data from a six-minute observation period. The granules are forwarded, along with calibration data, to the Level-1B PGEs for processing into calibrated, geolocated radiance products. The Level-2 PGEs, which are not yet operational, are intended to process the level-1B data into temperature and humidity profiles, and other geophysical properties.

De Picciotto, Solomon↗

Cassini Returns to Saturn's Poles: Seasonal Change in the Polar Vortices

High inclination orbits during Cassini's solstice mission (2012) are providing us with our first observations of Saturn's high latitudes since the prime mission (2007). Since that time, the northern spring pole has emerged into sunlight and the southern autumn pole has disappeared into winter darkness, allowing us to study the seasonal changes occurring within the polar vortices in response to these dramatic insolation changes. Observations from the Cassini Composite Infrared Spectrometer] have revealed (i) the continued presence of small, cyclonic polar hotspots at both spring and autumn poles; and (ii) the emergence of an infrared-bright polar vortex at the north pole, consistent with the historical record of Saturn observations from the 1980s (previous northern spring).

Cassini↗

Generation and Performance of Automated Jarosite Mineral Detectors for Vis/NIR Spectrometers at Mars

Sulfate salt discoveries at the Eagle and Endurance craters in Meridiani Planum by the Mars Exploration Rover Opportunity have proven mineralogically the existence and involvement of water in Mars past. Visible and near infrared spectrometers like the Mars Express OMEGA, the Mars Reconnaissance Orbiter CRISM and the 2009 Mars Science Laboratory Rover cameras are powerful tools for the identification of water-bearing salts and other high priority minerals at Mars. The increasing spectral resolution and rover mission lifetimes represented by these missions currently necessitate data compression in order to ease downlink restrictions. On board data processing techniques can be used to guide the selection, measurement and return of scientifically important data from relevant targets, thus easing bandwidth stress and increasing scientific return. We have developed an automated support vector machine (SVM) detector operating in the visible/near-infrared (VisNIR, 300-2500 nm) spectral range trained to recognize the mineral jarosite (typically KFe3(SO4)2(OH)6), positively identified by the Mossbauer spectrometer at Meridiani Planum. Additional information is included in the original extended abstract.

Gilmore, M. S.↗

Processing AIRS Scientific Data Through Level 2

The Atmospheric Infrared Spectrometer (AIRS) Science Processing System (SPS) is a collection of computer programs, denoted product generation executives (PGEs), for processing the readings of the AIRS suite of infrared and microwave instruments orbiting the Earth aboard NASA s Aqua spacecraft. AIRS SPS at an earlier stage of development was described in "Initial Processing of Infrared Spectral Data' (NPO-35243), NASA Tech Briefs, Vol. 28, No. 11 (November 2004), page 39. To recapitulate: Starting from level 0 (representing raw AIRS data), the PGEs and their data products are denoted by alphanumeric labels (1A, 1B, and 2) that signify the successive stages of processing. The cited prior article described processing through level 1B (the level-2 PGEs were not yet operational). The level-2 PGEs, which are now operational, receive packages of level-1B geolocated radiance data products and produce such geolocated geophysical atmospheric data products such as temperature and humidity profiles. The process of computing these geophysical data products is denoted "retrieval" and is quite complex. The main steps of the process are denoted microwave-only retrieval, cloud detection and cloud clearing, regression, full retrieval, and rapid transmittance algorithm.

Oliphant, Robert↗

Design of a precision etalon position control system for a cryogenic spectrometer

The Upper Atmosphere Research Satellite (UARS) will be launched in 1988 to study the distribution of a series of trace elements in the upper atmosphere and to study atmospheric dynamics. The UARS carries on board a cryogenically cooled infrared spectrometer to measure the concentration of a series of chemical species that are important for understanding the ozone layer in the stratosphere. This device, known as the Cryogenic Limb Array Etalon Spectrometer (CLAES), uses a multiposition filter wheel combined with tilt-scanned Fabry Perot etalons to obtain the high resolution required for these experiments. The CLAES optical system is sealed in a dewar where it is maintained at cryogenic temperatures by a supply of solid hydrogen. Operating temperatures for CLAES range from 130 K at the entrance aperture to 13 K at the focal plane. The design and test of a special control system using a unique actuator concept to provide position and can control for the CLAES etalon are described. Results of performance tests at cryogenic temperatures simulating the CLAES on-orbit environment are discussed.

Aubrun, J. N.↗

Pyroelectric Materials for Uncooled Infrared Detectors: Processing, Properties, and Applications

Uncooled pyroelectric detectors find applications in diverse and wide areas such as industrial production; automotive; aerospace applications for satellite-borne ozone sensors assembled with an infrared spectrometer; health care; space exploration; imaging systems for ships, cars, and aircraft; and military and security surveillance systems. These detectors are the prime candidates for NASA s thermal infrared detector requirements. In this Technical Memorandum, the physical phenomena underlying the operation and advantages of pyroelectric infrared detectors is introduced. A list and applications of important ferroelectrics is given, which is a subclass of pyroelectrics. The basic concepts of processing of important pyroelectrics in various forms are described: single crystal growth, ceramic processing, polymer-composites preparation, and thin- and thick-film fabrications. The present status of materials and their characteristics and detectors figures-of-merit are presented in detail. In the end, the unique techniques demonstrated for improving/enhancing the performance of pyroelectric detectors are illustrated. Emphasis is placed on recent advances and emerging technologies such as thin-film array devices and novel single crystal sensors.

Aggarwal, M. D.↗

Observing System Simulation Experiments Investigating Atmospheric Motion Vectors and Radiances from a Constellation of 4-5 μm Infrared Sounders

A set of Observing System Simulation Experiments (OSSEs) was performed to investigate the utility of a constellation of passive infrared spectrometers, strategically designed with the aim of deriving the three-dimensional retrievals of the horizontal wind via atmospheric motion vectors (AMVs) from instruments with the spectral resolution of an infrared sounder. The instrument and constellation designs were performed in the context of the Midwave Infrared Sounding of Temperature and humidity in a Constellation for Winds, or MISTiC Winds. The Global Modeling and Assimilation Office OSSE system, which includes a full suite of operational meteorological observations, served as the control. To illustrate the potential impact of this observing strategy, two experiments were performed by adding the new simulated observations to the control. First, perfect (error-free) simulated AMVs and radiances were assimilated. Second, the data were made imperfect by adding realistic modeled errors to the AMVs and radiances that were assimilated. The experimentation showed beneficial impacts on both the mass and wind fields, as based on analysis verification, forecast verification, and the assessment of the observations using the Forecast Sensitivity to Observation Impact (FSOI) metric. In all variables and metrics, the impacts of the imperfect observations were smaller than those of the perfect observations, though much of the positive benefit was retained. The FSOI metric illustrated two key points. First, the largest impacts were seen in the middle troposphere AMVs, which is a targeted capability of the constellation strategy. Second, the addition of modeled errors showed that the assimilation system was unable to fully exploit the 4.3 μm carbon dioxide absorption radiances.

Will McCarty↗

Observing System Simulation Experiments Investigating Atmospheric Motion Vectors and Radiances from a Constellation of 4–5-μm Infrared Sounders

A set of observing system simulation experiments (OSSEs) was performed to investigate the utility of a constellation of passive infrared spectrometers, strategically designed with the aim of deriving the three-dimensional retrievals of the horizontal wind via atmospheric motion vectors (AMVs) from instruments with the spectral resolution of an infrared sounder. The instrument and constellation designs were performed in the context of the Midwave Infrared Sounding of Temperature and humidity in a Constellation for Winds (MISTiC Winds). The Global Modeling and Assimilation Office OSSE system, which includes a full suite of operational meteorological observations, served as the control. To illustrate the potential impact of this observing strategy, two experiments were performed by adding the new simulated observations to the control. First, perfect (error free) simulated AMVs and radiances were assimilated. Second, the data were made imperfect by adding realistic modeled errors to the AMVs and radiances that were assimilated. The experimentation showed beneficial impacts on both the mass and wind fields, as based on analysis verification, forecast verification, and the assessment of the observations using the forecast sensitivity to observation impact (FSOI) metric. In all variables and metrics, the impacts of the imperfect observations were smaller than those of the perfect observations, although much of the positive benefit was retained. The FSOI metric illustrated two key points. First, the largest impacts were seen in the middle troposphere AMVs, which is a targeted capability of the constellation strategy. Second, the addition of modeled errors showed that the assimilation system was unable to fully exploit the 4.3-μm carbon dioxide absorption radiances.

Will McCarty↗

Preliminary evaluation of the airborne imaging spectrometer for vegetation analysis in the Klamath National Forest of northeastern California

The experiences and results associated with a project entitled Preliminary Evaluation of the Airborne Imaging Spectrometer for Vegetation Analysis is documented. The primary goal of the project was to provide ground truth, manual interpretation, and computer processing of data from an experimental flight of the Airborne Infrared Spectrometer (AIS) to determine the extent to which high spectral resolution remote sensing could differentiate among plant species, and especially species of conifers, for a naturally vegetated test site. Through the course of the research, JPL acquired AIS imagery of the test areas in the Klamath National Forest, northeastern California, on two overflights of both the Dock Well and Grass Lake transects. Over the next year or so, three generations of data was also received: first overflight, second overflight, and reprocessed second overflight. Two field visits were made: one trip immediately following the first overflight to note snow conditions and temporally-related vegetation states at the time of the sensor overpass; and a second trip about six weeks later, following acquisition of prints of the images from the first AIS overpass.

Strahler, A. H.↗

Mechanical testing of large cryogenic structures

The mechanical testing performed on the Cryogenic Limb Array Etalon Spectrometer (CLAES) instrument installed on the Upper Atmosphere Research Satellite is discussed. The CLAES determines temperatures and concentrations of stratospheric minor species as a function of altitude by measuring the atmospheric infrared emission spectra. CLAES is based on a telescope optical system and infrared spectrometer which are cooled with cryogens.

Newkirk, Roger↗

Microshutter Arrays for NIRSpec

A primary science goal of the 6.5 m James Webb Space Telescope is to characterize the epoch of initial galaxy formation, observing the early universe as the first stars and galaxies formed. This program will be accomplished using a combination of multi-band imaging and spectroscopic measurements of large numbers of faint galaxies. Since these objects are in general sparse on the sky, a multi object spectrometer is required to enable this critical scientific investigation. We have developed a microshutter array which is to be used as a high contrast, remotely programmable field selector for the Near Infrared Spectrometer (NIRSpec) on JWST. This device allows slits to be opened at the locations of selected galaxies in the field of view, and blocks sources and background light from the rest of the field. The first flight design devices have been built and were tested. These first generation of devices were used to demonstrate performance and flight readiness. Devices of the same design will be delivered to ESA for installation into the NIRSpec instrument.

Silverberg, Robert↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗