Search NASA⌕ Search

SEARCH · Search NASA

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Modeling and Evaluation of Geophysical Methods for Monitoring and Tracking CO2 Migration

Geological sequestration has been proposed as a viable option for mitigating the vast amount of CO 2 being released into the atmosphere daily. Test sites for CO 2 injection have been appearing across the world to ascertain the feasibility of capturing and sequestering carbon dioxide. A major concern with full scale implementation is monitoring and verifying the permanence of injected CO 2 . Geophysical methods, an exploration industry standard, are non-invasive imaging techniques that can be implemented to address that concern. Geophysical methods, seismic and electromagnetic, play a crucial role in monitoring the subsurface pre- and post-injection. Seismic techniques have been the most popular but electromagnetic methods are gaining interest. The primary goal of this project was to develop a new geophysical tool, a software program called GphyzCO2, to investigate the implementation of geophysical monitoring for detecting injected CO 2 at test sites. The GphyzCO2 software consists of interconnected programs that encompass well logging, seismic, and electromagnetic methods. The software enables users to design and execute 3D surface-to-surface (conventional surface seismic) and borehole-to-borehole (cross-hole seismic and electromagnetic methods) numerical modeling surveys. The generalized flow of the program begins with building a complex 3D subsurface geological model, assigning properties to the models that mimic a potential CO 2 injection site, numerically forward model a geophysical survey, and analyze the results. A test site located in Warren County, Ohio was selected as the test site for the full implementation of GphyzCO2. Specific interest was placed on a potential reservoir target, the Mount Simon Sandstone, and cap rock, the Eau Claire Formation. Analysis of the test site included well log data, physical property measurements (porosity), core sample resistivity measurements, calculating electrical permittivity values, seismic data collection, and seismic interpretation. The data was input into GphyzCO2 to demonstrate a full implementation of the software capabilities. Part of the implementation investigated the limits of using geophysical methods to monitor CO 2 injection sites. The results show that cross-hole EM numerical surveys are limited to under 100 meter borehole separation. Those results were utilized in executing numerical EM surveys that contain hypothetical CO 2 injections. The outcome of the forward modeling shows that EM methods can detect the presence of CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Performance characteristics of LOX-H2, tangential-entry, swirl-coaxial, rocket injectors

Development of a high performing swirl-coaxial injector requires an understanding of fundamental performance characteristics. This paper addresses the findings of studies on cold flow atomic characterizations which provided information on the influence of fluid properties and element operating conditions on the produced droplet sprays. These findings are applied to actual rocket conditions. The performance characteristics of swirl-coaxial injection elements under multi-element hot-fire conditions were obtained by analysis of combustion performance data from three separate test series. The injection elements are described and test results are analyzed using multi-variable linear regression. A direct comparison of test results indicated that reduced fuel injection velocity improved injection element performance through improved propellant mixing.

Howell, Doug↗

Proton Injection into the Fermilab Integrable Optics Test Accelerator (IOTA)

The Integrable Optics Test Accelerator (IOTA) is an experimental synchrotron being built at Fermilab to test the concept of non-linear "integrable optics". These optics are based on a lattice including non-linear elements that satisfies particular conditions on the Hamiltonian. The resulting particle motion is predicted to be stable but without a unique tune. The system is therefore insensitive to resonant instabilities and can in principle store very intense beams, with space charge tune shifts larger than those which are possible in conventional linear synchrotrons. The ring will initially be tested with pencil electron beams, but this poster describes the ultimate plan to install a 2.5 MeV RFQ to inject protons, which will produce tune shifts on the order of unity. Technical details will be presented, as well as simulations of protons in the ring.

43 PARTICLE ACCELERATORS↗

Aboveground Injection Sytem Construction and Mecahnical Integrity Test Plan

An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a fullscale system.

54 ENVIRONMENTAL SCIENCES↗

Fluidic Control of Nozzle Flow: Some Performance Measurements

Results are presented of an experimental program that investigated the use of a secondary air stream to control the amount of flow through a convergent-divergent nozzle. These static tests utilized high pressure, ambient temperature air that was injected at the throat of the nozzle through an annular slot. Multiple injection slot sizes and injection angles were tested. The introduction of secondary flow was made in an opposing direction to the primary flow and the resulting flow field caused the primary stream to react as though the physical throat size had been reduced. The percentage reduction in primary flow rate was generally about twice the injected flow rate. The most effective throttling was achieved by injecting through the smallest slot in an orientation most nearly opposed to the approaching primary flow. Thrust edliciency, as measured by changes in nozzle thrust coefficient, was highest at high nozzle pressure ratios, NPR. The static test results agreed with predictions obtained prior from PABSD, a fully viscous computational fluid dynamics program. Since use of such an injection system on gas turbine engine exhaust nozzles would be primarily at high NPRs, it was concluded that fluidic control holds promise for reducing nozzle weight and complexity on future systems.

Federspiel, John↗

Cr Field Testing

This is a summary of CR Project Field Tests including: Borehole Dilution Tracer Tests (Point Estimates of Flow Velocity), Push-Pull Tracer Tests at R-42 and R-28 (Flow Velocity and Dual-Porosity), Long Term Pump Test Trends, Carbonate/Bicarbonate Injection in R-42 (Cr desorption?), Cross-Hole Tracer Test (CrPZ-2a, CrPZ-2b, R-28 Injections; CrEX-3 Pumping), and Long-Term Trends in Plume Periphery Monitoring Wells.

58 GEOSCIENCES↗

Test of Point-Source Helicity Injection for Non-Solenoidal Startup in NSTX

This grant supported research activity focused on the development of Local Helicity Injection (LHI) as a technique for initiation and growth of spherical tokamak plasmas without the use of a traditional ohmic solenoid for magnetic induction. The LHI technique consists of injection of high-density current streams into a vacuum magnetic field consisting of toroidal and vertical fields. Under appropriate conditions, these streams become unstable and support magnetic reconnection to allow the system to reconfigure itself into a tokamak-like plasma magnetic configuration. This research program focused on three aspects of this plasma startup technique: 1) development and tests of appropriate electron current sources that provide sufficiently high injection currents into the near-plasma edge without strongly contaminating the resultant tokamak plasma with impurities; 2) development and validation of a 0-D power balance model to describe the evolution of the plasma current I p (t) during this startup process; and 3) initial estimates of I p levels achievable with this technique in NSTX-U scale plasmas. The 0-D model development included extremely low aspect ratio corrections to analytical formulae for the plasma inductances that produce voltages due to rapid changes in plasma size and location. Applications of this model to sample plasmas in the Pegasus ultra-low aspect ratio tokamak confirms the expectation that I p (t) is dominated by these induced voltages when injection occurs from the outer low-field side of the plasma. Conversly, I p (t) is dominated by an effective toroidal loop voltage arising from helicity conservation when injectors are placed in the inner high-field side divertor region. The activities pursued here, combined with more general research on LHI followed by the Pegasus experiment group, provide the tools needed for initial consideration of a MA-level plasma startup capability for the NSTX-U experiment. Simplified modeling for LHI on NSTX-U indicates that no showstoppers exist, and ~ 0.8MA appears accessible using a moderate current injection facility. However, many issues remain to be resolved to address extrapolating this technique to the larger sizes and magnetic field strengths of NSTX-U and larger fusion-grade tokamaks. These include, among others: I p scaling with helicity drive input; extending current injector technology; understanding electron confinement and the resulting helicity dissipation processes that determine the achievable I p ; the role of plasma stability in controlling the current evolution; and controlling plasma-material interactions and impurity content. These open issues will be further explored in a future experiment dedicated to integrated studies of non-solenoidal startup at higher magnetic fields and plasma currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and preliminary tests of a blade tip air mass injection system for vortex modification and possible noise reduction on a full-scale helicopter rotor

Full-scale tests were conducted on the Langley helicopter rotor test facility as part of a study to evaluate the effectiveness of a turbulent blade tip air mass injection system in alleviating the impulsive noise (blade slap) caused by blade-vortex interaction. Although blade-slap conditions could not be induced during these tests, qualitative results from flow visualization studies using smoke showed that the differential velocity between the jet velocity and the rotor tip speed was a primary parameter controlling the vortex modification.

Pegg, R. J.↗

Scale-Up Testing-Foam as a Remedial Amendment Carrier

This paper describes results from intermediate-scale, two-dimensional testing of foam injection into sedimentary materials collected from the U.S. Department of Energy (DOE) Hanford Site. The testing was performed to evaluate the effects of delivery pressure, injection rate, foam stability, foam quality, and formation heterogeneities on the migration of foam, water, remediation amendment, and contaminants within a sedimentary volume. Testing was accomplished in a test bed that is configured in the form of two thin rectangular boxes. Each of the boxes holds approximately 135 liters (255 kilograms) of sediment. Foam was injected into each box through a segment of polyvinyl chloride slotted well casing, and air was extracted from the boxes through a similar system. Four sets of tests were conducted. During Test 1, both of the boxes were loaded in a homogeneous manner, while in Tests 2, 3, and 4, both of the boxes were loaded so as to contain two rectangular zones of heterogeneity. In addition, a zone of the sediment contained in the test bed used for Test 4 was augmented with uranium-rich calcite to produce a known concentration of uranium. The injection rate varied between the boxes during the Test 1 but was the same for each box during the final three tests. The foam generation formula for Tests 1 and 2 consisted of an aqueous solution of anionic surfactant. The foam generation formula used in Test 3 consisted of an aqueous solution of anionic surfactant and contained 25,000 milligrams per liter (mg/L) of phosphate in the form of a 9:1 mixture of sodium phosphate and sodium tripolyphosphate. The foam generating formula used in Test 4 consisted of an aqueous solution of an anionic surfactant and a nonionic surfactant and also contained 5,000 mg/L of phosphate as the aforementioned mixture. Subsequent to each of the four tests, the test beds were disassembled, and samples of the sediments were taken and analyzed for a number of parameters, depending on the specific test. This paper presents the results of the intermediate-scale testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SECARB Permits for Seismic and Other Site Preparation Plan

The Southeast Regional Carbon Sequestration Partnership’s (SECARB’s) Anthropogenic Test is a demonstration of the deployment of CO 2 capture, transport, geologic storage and monitoring technologies. This project is one of the first and the largest fully integrated commercial prototype coal-fired carbon capture and storage projects in the USA. Drilled in January 2011, a deep characterization well provided geologic data confirming that the test site represented an attractive location for safe, long-term storage of CO 2 . Two Class V Experimental Injection Well underground injection control (UIC) permits were issued in November 2011 and subsequently the project’s injection wells were installed. A robust monitoring, verification and accounting (MVA) plan has been developed to monitor and track the CO 2 plume and the associated pressure field. The CO 2 MVA effort for the Anthropogenic Test CO 2 (Test) injection demonstration includes two wellbore seismic methods, specifically time-lapse Croswell seismic and vertical seismic profiles (VSP). Due to the unique challenges presented by this Test (injection depth of 9,500+ ft. into thin, stacked reservoir sands and limited injection volumes) surface seismic was eliminated as a Monitoring, Verification, and Accounting (MVA) tool. However, the newly drilled project wells provided ample casing diameters (prior to running tubing) to accommodate wellbore seismic receivers (wireline and tubing deployed) and a Croswell source.

54 ENVIRONMENTAL SCIENCES↗

Development and evaluation of a fault-tolerant multiprocessor (FTMP) computer. Volume 4: FTMP executive summary

The FTMP architecture is a high reliability computer concept modeled after a homogeneous multiprocessor architecture. Elements of the FTMP are operated in tight synchronism with one another and hardware fault-detection and fault-masking is provided which is transparent to the software. Operating system design and user software design is thus greatly simplified. Performance of the FTMP is also comparable to that of a simplex equivalent due to the efficiency of fault handling hardware. The FTMP project constructed an engineering module of the FTMP, programmed the machine and extensively tested the architecture through fault injection and other stress testing. This testing confirmed the soundness of the FTMP concepts.

Smith, T. B., III↗

Characterization and Alteration of Wettability States of Alaskan Reserviors to Improve Oil Recovery Efficiency (including the within-scope expansion based on Cyclic Water Injection - a pulsed waterflood for Enhanced Oil Recovery)

Numerous early reports on experimental works relating to the role of wettability in various aspects of oil recovery have been published. Early examples of laboratory waterfloods show oil recovery increasing with increasing water-wetness. This result is consistent with the intuitive notion that strong wetting preference of the rock for water and associated strong capillary-imbibition forces gives the most efficient oil displacement. This report examines the effect of wettability on waterflooding and gasflooding processes respectively. Waterflood oil recoveries were examined for the dual cases of uniform and non-uniform wetting conditions. Based on the results of the literature review on effect of wettability and oil recovery, coreflooding experiments were designed to examine the effect of changing water chemistry (salinity) on residual oil saturation. Numerous corefloods were conducted on reservoir rock material from representative formations on the Alaska North Slope (ANS). The corefloods consisted of injecting water (reservoir water and ultra low-salinity ANS lake water) of different salinities in secondary as well as tertiary mode. Additionally, complete reservoir condition corefloods were also conducted using live oil. In all the tests, wettability indices, residual oil saturation, and oil recovery were measured. All results consistently lead to one conclusion; that is, a decrease in injection water salinity causes a reduction in residual oil saturation and a slight increase in water-wetness, both of which are comparable with literature observations. These observations have an intuitive appeal in that water easily imbibes into the core and displaces oil. Therefore, low-salinity waterfloods have the potential for improved oil recovery in the secondary recovery process, and ultra low-salinity ANS lake water is an attractive source of injection water or a source for diluting the high-salinity reservoir water. As part of the within-scope expansion of this project, cyclic water injection tests using high as well as low salinity were also conducted on several representative ANS core samples. These results indicate that less pore volume of water is required to recover the same amount of oil as compared with continuous water injection. Additionally, in cyclic water injection, oil is produced even during the idle time of water injection. It is understood that the injected brine front spreads/smears through the pores and displaces oil out uniformly rather than viscous fingering. The overall benefits of this project include increased oil production from existing Alaskan reservoirs. This conclusion is based on the performed experiments and results obtained on low-salinity water injection (including ANS lake water), vis-a-vis slightly altering the wetting conditions. Similarly, encouraging cyclic water-injection test results indicate that this method can help achieve residual oil saturation earlier than continuous water injection. If proved in field, this would be of great use, as more oil can be recovered through cyclic water injection for the same amount of water injected.

02 PETROLEUM↗

A horizontal powder injector for W7-X

We report that injection of low-Z powders into fusion plasma has been used to improve wall conditions, similar to the standard boronization process using diborane. Powder injection has the advantage of being much simpler, non-toxic, and efficient. The W7-X stellarator is planning on utilizing powder injection in long pulse discharges; a proof-of-principle test for horizontal injection into the plasma was conceived, a Probe Mounted Particle Injector (PMPI). The PMPI concept is developed using a polyetheretherketone (PEEK) paddle wheel hub that is driven by a piezo motor, due to the high magnetic fields, that rotates at 100 deg/s. This small PMPI fits into an envelope of 120 mm diameter × 150 mm long, a standard size for Multi-Purpose Manipulator (MPM). The device is housed in a carbon cup mounted on a retractable probe that can be placed near the plasma edge, enabling powder injection ˜4–8 cm radially into the boundary plasma. The feed for the paddle is via piezo electric actuator that vibrates a funnel filled with powder into a trough for the paddle to push. The 8 paddle arms, 35 mm long and 10 mm wide, are made from 0.38 mm thick PEEK which drag slightly along the powder-filled trough bottom, becoming a spring-loaded paddle which accelerates the powder upon release. Finally, design challenges are the high ambient magnetic field, vacuum compatible materials, high temperature environment, limited rotary-drive options, and compact space. The design and testing of this new device will be presented.

36 MATERIALS SCIENCE↗

Scale-up Testing—Foam as A Remedial Amendment Carrier - 11029

This paper describes results from intermediate-scale, two-dimensional testing of foam injection into sedimentary materials collected from the U.S. Department of Energy (DOE) Hanford Site area. The testing was performed to evaluate the transport of new, more robust, foam generation formulas developed by PNNL on field applicability. The mechanisms of transport , foam stability, delivery pressure, foam migration and the ability of foam to deliver remedial amendments for stabilization of uranium contamination were evaluated. Testing was accomplished in a test bed that is designed to focus on two-dimensional flow, in the form of two, thin rectangular boxes. Each of the boxes holds approximately 135 liters (255 kilograms) of sediment. A total of six sets of tests have been conducted, the last two of which will be described here. During the fifth and sixth tests, foam, generated by means of mechanical blending, was injected into the central screened segment of the left side of each box while air was extracted from multiple screened segments along the right side of each box. During these two tests both of the boxes were loaded to contain a rectangular zones of fine material and a rectangular zone of coarse material . Portions of the sediment were augmented with uranium-rich calcite to produce known concentrations of uranium. The foam generating formulas used in both tests contained sodium phosphate and sodium tripolyphosphate as a remedial amendment. Subsequent to each of the two tests, the test beds were disassembled, and samples of the sediments were taken and analyzed for a number of parameters, depending on the specific test. The data indicated that uranium contamination may be successfully immobilized and that that directional movement of the injected foam can be controlled.

Foam↗

Effect of Orifice Length-Diameter Ratio on Spray Characteristics

The effect of variations of orifice length to diameter ratio on spray characteristics was determined for a 0.014-inch and a 0.040-inch orifice for ratio of 0.5 to 4.0. The nozzles containing the orifices were mounted in an injection valve and tested with a plan stem and with a helically grooved stem. The injection pressure was varied from 4000 to 8000 pounds per square inch. The air density into which the fuel was sprayed was varied from the density obtained with a pressure of 60 pounds per square inch to the density obtained with a pressure of 250 pounds per square inch at room temperature. The tests showed that increasing the orifice length to diameter ratio with a plain stem in the injection valve causes the spray tip penetration first to decrease, reaching a minimum between a ratio of 1.5 and 2.5, and then to increase, reaching a maximum at a ratio greater than 3.5. The spray cone angle showed little change with variation of the ratio. With a helically grooved stem and small ratio of orifice area to groove area, the penetration at first shows little tendency towards a minimum; but as the time of injection is increased to 0.004 second, the penetration becomes a minimum at a ratio between 0.5 and 2.0.

Gellales, A G↗

Thermal-hydraulic validation tests using the SMART-ITL facility with a single train passive safety injection system for the smart design

A test program was launched using a large-scale thermal-hydraulic integral effect test facility of SMART-ITL (or FESTA) to validate the performance of the SMART passive safety system. In this paper thermal-hydraulic validation tests using the SMART-ITL facility equipped with a single train of a passive safety injection system were performed and their major results were summarized. The effect of the flow distributor, break size and different types of Core Makeup Tank (CMT) and Safety Injection Tank (SIT) on the thermal-hydraulic behavior during a Small-Break Loss of Coolant Accident (SBLOCA) scenario was investigated for the SMART passive safety system development. During the SBLOCA scenario, the water layer was well stratified thermally in the core makeup tank, and the safety injection water was injected efficiently into the reactor pressure vessel from the initial period. Eventually, the reactor coolant system was cooled down properly. From the test results, it was estimated that the SMART passive safety system has sufficient cooling capability to deal with the SBLOCA scenario of SMART. The acquired data will be used to validate the safety analysis code and its related models, to evaluate the performance of SMART PSS, and to provide the base data during the application phase of the revision of standard design approval and construction licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Magnetron R&Ds for High Efficiency CW RF Sources of Particle Accelerators

A proof of principle experiment carried out at JLab's magnetron R&D test stand has demonstrated a -25dB injection signal to phase lock a 2.45GHz 1.2kW CW magnetron within 2.1 Hz of root mean square deviation (RMSD) value with the optimization of magnetic field trimming of ±25% in order to overcome the frequency pushing of more than 4MHz in the RF power output range of 45-100%. In addition, a test stand for a newly built 1497 MHz, 13kW, CW magnetron prototype is ready for the high power injection test with outcome aimed for the CEBAF klystron replacement. Based on these R&D results, a 915MHz, 2?75kW CW commercial heating type magnetron system is being developed as high efficiency (>80%) RF source to drive an electron linac for industrial applications.

Wang, H.↗