Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Solar domestic hot water system installed at Texas City, Texas

This is the final technical report of the solar energy system located at LaQuinta Motor Inn, Texas City, Texas. The system was designed to supply 63 percent of the total hot water load for a new 98 unit motor inn. The solar energy system consists of a 2100 square feet Raypack liquid flat plate collector subsystem and a 2500 gallon storage subsystem circulating hot water producing 3.67 x 10 to the 8th power Btu/year. Abstracts from the site files, specification references, drawings, installation, operation, and maintenance instructions are included.

Source record↗

Effects of sidewall geometry on the installed performance of nonaxisymmetric convergent-divergent exhaust nozzles

The investigation was conducted at static conditions and over a Mach number range from 0.6 to 1.2. Angle of attack was held constant at 0 deg. High pressure air was used to simulate jet exhaust flow at ratios of jet total pressure to free-stream static pressure from 1 (jet off) to approximately 10. Sidewall cutback appears to be a viable way of reducing nozzle weight and cooling requirements without compromising installed performance.

Yetter, J. A.↗

Advanced turboprop installation aerodynamics

The expected aerodynamic effects of a propfan installed on a thick supercritical wing are summarized qualitatively. Nacelle/wing and jet interactions, slipstream incremental velocity, nonuniform inflow, and swirl loss recovery are discussed.

Smith, R. C.↗

Aeropropulsive characteristics of twin nonaxisymmetric vectoring nozzles installed with forward-swept and aft-swept wings

An investigation was conducted in the Langley 16 Foot Transonic Tunnel to determine the aeropropulsive characteristics of a single expansion ramp nozzle (SERN) and a two dimensional convergent divergent nozzle (2-D C-D) installed with both an aft swept and a forward swept wing. The SERN was tested in both an upright and an inverted position. The effects of thrust vectoring at nozzle vector angles from -5 deg to 20 deg were studied. This investigation was conducted at Mach numbers from 0.40 to 1.20 and angles of attack from -2.0 deg to 16 deg. Nozzle pressure ratio was varied from 1.0 (jet off) to about 9.0. Reynolds number based on the wing mean geometric chord varied from about 3 million to 4.8 million, depending upon free stream number.

Capone, F. J.↗

Solar space and water heating system installed at Charlottesville, Virginia

The solar energy system located at David C. Wilson Neuropsychiatric Hospital, Charlottesville, Virginia, is described. The solar energy system consists of 88 single glazed, Sunworks 'Solector' copper base plate collector modules, hot water coils in the hot air ducts, a Domestic Hot Water (DHW) preheat tank, a 3,000 gallon concrete urethane insulated storage tank and other miscellaneous components. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are included.

Source record↗

Solar space heating installed at Kansas City, Kansas

The solar energy system was constructed with the 48,800 square feet warehouse to heat the warehouse area of about 39,000 square feet while an auxiliary energy system heats the office area of about 9,800 square feet. The building is divided into 20 equal units, and each has its own solar system. The modular design permits the flexibility of combining multiple units to form offices or warehouses of various size floor areas as required by a tenant. Each unit has 20 collectors which are mounted in a single row. The collectors are double glazed flat plate collectors with a gross area of 7,800 sq ft. Air is heated either through the collectors or by the electric resistance duct coils. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are presented.

Source record↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗

Considerations for the installation of honeycomb and screens to reduce wind-tunnel turbulence

Tests were conducted on a half-scale model representing a 0.914-m (3.0-ft) square stream tube of the flow through the fourth corner and settling chamber of the Langley 8-Foot Transonic Pressure Tunnel. The model included the tube cooler 45 degree turning vanes, and the turbulence reduction screens and honeycomb, which were the subject of the tests. Hot-wire measurements of the turbulence reduction for various combinations of screens and honeycomb were made at various duct speeds. Of the four sizes of honeycomb cells tested, none were found to have a superior performance advantage. The effectiveness of screens and honeycomb in reducing turbulence is greatly affected by relatively minor physical damage; therefore, extreme care must be exercised in installing and maintaining honeycomb or screens if the turbulence reduction performance is to be maintained.

Scheiman, J.↗

Solar heating and hot water system installed at James Hurst Elementary School, Portsmouth, Virginia

Solar heating and a hot water system installed in an elementary school in Portsmouth, Virginia are examined. The building is zoned into four heating/cooling areas. Each area is equipped with an air handling unit that is monitored and controlled by central control and monitoring system. The solar system for the building uses a collector area of 3,630 sq. ft. of flat plate liquid collectors, and a 6,000 gallon storage tank. System descriptions, maintenance reports, detailed component specifications, and design drawings to evaluate this solar system are reported.

Source record↗

Description of the warm core turbine facility and the warm annular cascade facility recently installed at NASA Lewis Research Center

The two new facilities have been installed and operated at their design or rated conditions. The important feature of both of these facilities is that the ratio of turbine inlet temperature to coolant temperature encountered in high temperature engines can be duplicated at moderate turbine inlet temperature. Included in the discussion are the limits of the facilities with regard to maximum temperature, maximum pressure, maximum mass flow rate, turbine size, and dynamometer torque-speed characteristics.

Whitney, W. J.↗

Subsonic/supersonic nonvectored aeropropulsive characteristics of nonaxisymmetric nozzles installed on an F-18 model

An experimental program on a model of the F-18 airplane has been conducted to determine the performance of nonaxisymmetric nozzles relative to the aircraft's baseline axisymmetric nozzle at Mach numbers from 0.60 to 2.20. The performance of a two-dimensional convergent-divergent nozzle, a single expansion ramp nozzle (ADEN) and a wedge nozzle were compared to the baseline axisymmetric nozzles. The nonaxisymmetric nozzles (except ADEN) were designed for vectoring and reversing. The axisymmetric nozzle did not have these capabilities. The comparisons presented here are for the nozzles in their full forward thrust mode and for the aircraft at zero angle of attack. The results demonstrate that nonaxisymmetric nozzles can be installed on a close-spaced twin engine fighter with equal or higher performance than the axisymmetric nozzle over the range of Mach numbers tested.

Capone, F. J.↗

A method and technique for installing light-weight fragile, high-temperature fiber insulation

A method of installing fragile, light-weight, high-temperature fiber insulation, particularly where the insulation is to be used as a seal strip providing a high order of thermal barrier insulation is described. The process is based on provision of a strip of the mineral batting cut oversize by a predetermined amount, saturated in a fugitive polymer solution, compressed in a mold, dried and cured to form a rigidized batting material which may be machined to required shape. The machined dimensions would normally be at least nominally less than the dimensions of the cavity to be sealed. After insertion in the cavity, which may be a wire-mesh seal enclosure, the apparatus is subjected to baking at a temperature sufficiently high to cause the resin to burn off cleanly, leaving the batting substantially in its original condition and expanded into the cavity or seal enclosure.

Ballantine, T. J.↗

Rough analysis of installation effects on turboprop noise

A rough analysis of noise from a propeller operated at angle of attack, and in the nonuniform flow due to a line vortex approximating a wing flow field suggests installation can significantly affect turboprop noise levels. On one side of the propeller, where the blades approach the horizontal plane from above, decreases of noise occur; while on the other side noise increases. The noise reduction is due to negative interference of steady and unsteady sources. An angle of attack, or distance between propeller and vortex, exists for which noise is a minimum.

Durbin, P. A.↗

Propfan installation aerodynamics of a supercritical swept wing transport configuration

A semispan model with a powered propeller has been tested to provide data on the installation drag penalty of advanced propfan-powered transports designed to cruise at a Mach number of 0.8. These tests, conducted in 14-foot and 11-foot transonic wind tunnels, are a part of a NASA program to develop efficient, high-speed propellers for more fuel-efficient commercial transports for the 1990s and beyond. The model is instrumented for measuring propeller forces, wing/nacelle forces and moments, and pressure distributions over the wing and nacelle. The body in these tests was nonmetric, being connected to the wing by an RTV seal at the wing/body juncture. Tests were run at angles of attack from -3 to +5 deg over the Mach number range 0.6 to 0.85 at a Reynolds number of about 9,000,000. Results of these tests indicate that the nacelle interference drag can be quite large relative to an uninstalled nacelle. However, the losses due to the nacelle were reduced to acceptable levels by changes to the wing leading edge and nacelle intersection. The propeller slipstream causes substantial changes in the wing span load distribution indicating that twist modifications are needed to recover a more favorable span load distribution.

Smith, R. C.↗

A comprehensive analysis of the performance characteristics of the Mount Laguna solar photovoltaic installation

This paper represents the first comprehensive survey of the Mount Laguna Photovoltaic Installation. The novel techniques used for performing the field tests have been effective in locating and characterizing defective modules. A comparative analysis on the two types of modules used in the array indicates that they have significantly different failure rates, different distributions in degradational space and very different failure modes. A life cycle model is presented to explain a multimodal distribution observed for one module type. A statistical model is constructed and it is shown to be in good agreement with the field data.

Shumka, A.↗