Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

Exploration Technology Developments Program's Radiation Hardened Electronics for Space Environments (RHESE) Project Overview

Primary Objective: 1) A computational tool to accurately predict electronics performance in the presence of space radiation in support of spacecraft design: a) Total dose; b) Single Event Effects; and c) Mean Time Between Failure. (Developed as successor to CR ME96.) Secondary Objectives: 2) To provide a detailed description of the natural radiation environment in support of radiation health and instrument design: a) In deep space; b) Inside the magnetosphere; and c) Behind shielding.

Keys, Andrew S.↗

Active/passive scanning

The paper deals with the design, construction, and applications of an active/passive multispectral scanner combining lasers with conventional passive remote sensors. An application investigation was first undertaken to identify remote sensing applications where active/passive scanners (APS) would provide improvement over current means. Calibration techniques and instrument sensitivity are evaluated to provide predictions of the APS's capability to meet user needs. A preliminary instrument design was developed from the initial conceptual scheme. A design review settled the issues of worthwhile applications, calibration approach, hardware design, and laser complement. Next, a detailed mechanical design was drafted and construction of the APS commenced. The completed APS was tested and calibrated in the laboratory, then installed in a C-47 aircraft and ground tested. Several flight tests completed the test program.

Woodfill, J. R.↗

Superconducting gravity gradiometer mission. Volume 2: Study team technical report

Scientific and engineering studies and developments performed or directed by a Study Team composed of various Federal and University activities involved with the development of a three-axis superconducting gravity gradiometer integrated with a six-axis superconducting accelerometer are examined. This instrument is being developed for a future orbital mission to make precise global gravity measurements. The scientific justification and requirements for such a mission are discussed. This includes geophysics, the primary mission objective, as well as secondary objective, such as navigation and feats of fundamental laws of physics, i.e., a null test of the inverse square law of gravitation and tests of general relativity. The instrument design and status along with mission analysis, engineering assessments, and preliminary spacecraft concepts are discussed. In addition, critical spacecraft systems and required technology advancements are examined. The mission requirements and an engineering assessment of a precursor flight test of the instrument are discussed.

Morgan, Samuel H.↗

Superconducting gravity gradiometer mission. Volume 1: Study team executive summary

An executive summary is presented based upon the scientific and engineering studies and developments performed or directed by a Study Team composed of various Federal and University activities involved with the development of a three-axis Superconducting Gravity Gradiometer integrated with a six-axis superconducting accelerometer. This instrument is being developed for a future orbital mission to make precise global gravity measurements. The scientific justification and requirements for such a mission are discussed. This includes geophysics, the primary mission objective, as well as secondary objectives, such as navigation and tests of fundamental laws of physics, i.e., a null test of the inverse square law of gravitation and tests of general relativity. The instrument design and status along with mission analysis, engineering assessments, and preliminary spacecraft concepts are discussed. In addition, critical spacecraft systems and required technology advancements are examined. The mission requirements and an engineering assessment of a precursor flight test of the instrument are discussed.

Morgan, Samuel H.↗

VAPoR - Volatile Analysis by Pyrolysis of Regolith - an Instrument for In Situ Detection of Water, Noble Gases, and Organics on the Moon

We present the Volatile Analysis by Pyrolysis of Regolith (VAPoR) instrument design and demonstrate the validity of an in situ pyrolysis mass spectrometer for evolved gas analyses of lunar and planetary regolith samples. In situ evolved gas analyses of the lunar regolith have not yet been carried out and no atmospheric or evolved gas measurements have been made at the lunar poles. VAPoR is designed to do both kinds of measurements, is currently under development at NASA's Goddard Space Flight Center, and will be able to heat powdered regolith samples or rock drill fines up to 1400 C in vacuo. To validate the instrument concept, evolved gas species released from different planetary analogs were determined as a function of temperature using a laboratory breadboard. Evolved gas measurements of an Apollo 16 regolith sample and a fragment of the carbonaceous meteorite Murchison were made by VAPoR and our results compared with existing data. The results imply that in situ evolved gas measurements of the lunar regolith at the polar regions by VAPoR will be a very powerful tool for identifying water and other volatile signatures of lunar or exogenous origin as potential resources for future human exploration.

ten Kate, I. L.↗

The PolCube CubeSat Polarimeter for Earth Science

PolCube is a 12U CubeSat + polarimeter instrument designed by NASA Langley and the Korea Astronomy and Space Science Institute (KASI) for Earth Science. PolCube is based on the PolCam polarimeter onboard the Korean Pathfinder Lunar Observatory (KPLO) that launched in August 2022. The objective of the PolCube instrument is to retrieve detailed fine-mode (pollution and smoke) and coarse-mode (sea-salt and dust) aerosol properties over the ocean for a range of light to heavy aerosol loadings using its polarimetric-imaging capability at multiple angles and wavelengths from 410 − 865 nm. An additional objective is to discriminate aerosols from thin clouds. We quantify the performance of aerosol and ocean remote sensing products from the PolCube polarimeter instrument using the Microphysical Aerosol Properties from Polarimetry (MAPP) remote sensing retrieval algorithm. PolCube’s accurate and high-resolution aerosol-retrieval products will provide unique spatial and temporal coverage of the Earth that can be used synergistically with other instruments, such as the PACE (Plankton, Aerosols, Clouds and Ecosystems) and GEMS (Geostationary Environmental Monitoring Spectrometer) mission to improve air-quality forecasting. We present the PolCube-MAPP retrieval algorithm, which used optimal estimation and artificial intelligence, as well as multiple powerful inherent optical property look-up-tables for the Earth’s aerosol, cloud, and hydrosol particles. We estimate that PolCube can retrieve total aerosol optical depth at 555 nm (AOD555) within ±0.068, fine-mode AOD555 within ±0.078, and fine-mode single-scattering albedo within ±0.036, where all uncertainties are expressed as one standard deviation (1σ).

Snorre Stamnes↗

Very high resolution radiometer /VHRR/

Discussion of the design and performance of the very high resolution radiometer (VHRR) representing the first of a second-generation of infrared scanning radiometers of high performance. Following a description of the optical, signal-electronics, sync-generator, scan-drive, cooler, and contamination-protection design, it is pointed out that the two VHRRs presently operating have logged a total of 15,500 hrs of continuous successful operation since launch. The cooler operation has been particularly noteworthy. The cold plate heater power, required to maintain the detectors at 105 K, has undergone in almost a year's operation so small a degradation as to indicate a VHRR cooler lifetime exceeding the instrument design lifetime of one year by a large margin. High resolution, low noise, and jitter-free pictures are shown to have been derived from these instruments.

Aronson, A. I.↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study and simulation results for video landmark acquisition and tracking technology (Vilat-2)

The results of several investigations and hardware developments which supported new technology for Earth feature recognition and classification are described. Data analysis techniques and procedures were developed for processing the Feature Identification and Location Experiment (FILE) data. This experiment was flown in November 1981, on the second Shuttle flight and a second instrument, designed for aircraft flights, was flown over the United States in 1981. Ground tests were performed to provide the basis for designing a more advanced version (four spectral bands) of the FILE which would be capable of classifying clouds and snow (and possibly ice) as distinct features, in addition to the features classified in the Shuttle experiment (two spectral bands). The Shuttle instrument classifies water, bare land, vegetation, and clouds/snow/ice (grouped).

Lowrie, J. W.↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the far infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 101/cm (99 microns). The instrumental concept and atmospheric measurements are discussed.

Pickett, H. M.↗

An Overview of the Mid-Infrared Spectro-Interferometer MATISSE: Science, Concept, and Current Status

MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 microns, exploring angular scales as small as 3 mas (L band) 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R approx. 30 to R approx. 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.

interferometric instrument↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Thermal Performance Comparison and Lessons Learned for the Thermal Infrared Sensor Instruments 1 & 2

The Thermal Infrared Sensor (TIRS-1) is one of two instruments on the Landsat-8 Mission, which launched in February of 2013 and remains operational. The TIRS-2 instrument was developed for the Landsat-9 Mission, which is scheduled to launch in September of 2021. The TIRS-2 instrument design was adjusted to account for requirements changes and to include key lessons learned from its predecessor. The overall thermal subsystem design of the TIRS Sensor Unit remained comparable from mission to mission, but there were some areas that needed modifications. The general design is comprised of five thermal zones which range in temperature from less than 43 Kelvin to 320 Kelvin. Most zones are proportional heater controlled. A two-stage cryocooler provided by Ball Aerospace is used to cool the cryogenic subsystem, and excess power dissipation is rejected via ammonia transport heat pipes to a dedicated cryocooler radiator with embedded ammonia heat pipes. The cryogenic subsystem includes a series of shells used to radiatively and conductively isolate the cold stage from the warmer surroundings. The Optical System (telescope) is passively cooled to 180-195 Kelvin using a dedicated radiator with embedded dual-bore ethane heat pipes. The warmer end of the instrument includes a Scene Select Mechanism, an on-board Black Body Calibrator with a dedicated radiator, and a Focal Plane Electronics Box, all of which are attached to the Sensor Unit primary structure. The TIRS-1 thermal subsystem design was successfully verified during an extended testing campaign and during more than 8years of on-orbit operations. The TIRS-2 thermal subsystem design was successfully verified during months of ground testing prior to delivery in August of 2019and at the Observatory level in the Spring of 2021. A detailed comparison of the thermal performance of the two instruments has been made with a focus on key lessons learned during each instrument development, and with the benefit of on-orbit data acquired for the TIRS-1 instrument.

Veronica Otero↗

Stratospheric OH measurements with a far-infrared limb observing spectrometer

The Far-Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure the hydroxyl radical (OH) and other chemical species in the upper atmosphere using limb emission in the far-infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain high spectral resolution near 101/cm and 118/cm. The instrument concept, calibration, and atmospheric measurements are discussed.

Pickett, H. M.↗

Lunar Scout Infrared Detector (LSIRD): Simple low-cost imaging spectrometer

A novel design for a compact, light weight, imaging spectrometer has been proposed for an orbiting Lunar mapping mission. Simple in design, its dual arm optical system employs a transmission grating and a dichroic mirror to provide continous two-octave spectral response. The grating's first order wavelengths are reflected into the SWIR arm, while the second order wavelenghts are transmitted to the VNIR arm. The instrument design is that of a push broom camera. It uses one of the detector(s) dimensions for spectral selection, the other detector(s) dimension for cross-track spatial selection, and the foward motion of the platform (in this case, a spececraft) for down-track spatial coverage.

Lunar↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗