Search NASA⌕ Search

SEARCH · Search NASA

Results for “internal standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dataset of mechanically induced thermal runaway measurement and severity level on Li-ion batteries

The deployment of Li-ion batteries covers a wide range of energy storage applications, from mobile phones, e-bikes, electric vehicles (EV) and stationary energy storage systems. However, safety issue such as thermal runaway is always one of the most important concerns to prevent Li-ion batteries from further market penetration. A standardized single-side indentation test protocol was developed to mechanically induce an internal short-circuit. The cell voltage, compressive load, indenter stroke, and temperature at the indentation point are measured in time series. The test data of each cell, along with cell parameters such as dimensions, mass, chemistry, state of charge (SOC), capacity, are integrated together to calculate a thermal runaway severity score from 0 to100. Complete data collection process including the original measured record, test method, severity score calculation scheme is presented in this article. The thermal runaway severity analysis and the more than 100 tested Li-ion battery records provide a good data source for further comparison and ranking of thermal runaway risks.

25 ENERGY STORAGE↗

Mechanically induced thermal runaway severity analysis of Li-ion batteries and continuous energy release monitoring

The large-scale deployment of Li-ion batteries in stationary energy storage and electrical vehicle applications demands a strong focus on safety, particularly on the thermal runaway risk and severity evaluation. A standardized single-side mechanical indentation test protocol was developed to induce an internal short-circuit (ISC) and evaluate cells' thermal runaway severity at different state of charge (SOC). The observed hazard severity (OHS in five categories) and evaluated scores in this work have a comprehensive consideration of each cell's capacity, initial voltage, SOC, temperature and voltage change, allowing a better evaluation of the cells' thermal runaway potential. This method was applied to about 200 Li-ion batteries in order to build an extensive thermal runaway database covering various SOCs, capacities and chemistries. In this study, we monitored the transitions of stored electrochemical energy and applied mechanical energy into both thermal energy and acoustic emissions (AE). The surface temperature and mechanical failures were monitored by infrared imaging and AE to capture critical events within battery cells throughout the mechanical indentation tests. Furthermore, the initial temperature maps can predict two types of follow-up events: thermal runaway or gradual heat release via conduction. Analyzing each cell's severity, AEs, and leveraging the evolving database offer insights into predicting occurrences of thermal runaway. The test method, thermal runaway severity evaluation and prediction, and the corresponding database provide battery designers, manufacturers, and end-users a clear overview of Li-ion batteries' thermal runaway potential under mechanical abuse, advancing the safety design of Li-ion batteries.

Acoustic emission↗

Performance Evaluation and Loss Modeling of WBG Devices based on a Novel Double-Pulse Test Method for Current Source Inverter

Careful measurements of the power device characteristics are necessary to accurately estimate a power converter's losses and efficiency. The conventional double-pulse test (DPT) circuit is a well-known method to implement this laboratory characterization of power devices and power modules. However, the switching characteristics of a power device depend on the power electronics circuit in which it is connected as well as the power circuit's physical layout, in addition to the device's internal structure. Hence, the conventional DPT circuit configuration, which is tailored for a standard voltage-source inverter (VSI), is not well-suited for a current-source inverter (CSI). This paper demonstrates a previously-proposed CSI-based DPT measurement technique that is appropriate for normal CSI operation. The characteristics of SiC MOSFETs and series-connected SiC Schottky diodes used in a CSI are measured using this improved technique while taking temperature effects into account to yield more accurate loss predictions. The CSI losses, including the switching and conduction losses of SiC MOSFETs and SiC Schottky diodes, have been modeled using this approach. The total CSI losses and efficiency have been estimated based on the CSI DPT results and loss models.

42 ENGINEERING↗

Dose Coefficient Calculation for Use in Dosimetry Assessment of a Fission-Based Weapon

In the event of a fission-based weapon or improvised nuclear device (IND) detonation, dose coefficients can be harnessed to provide dose assessments for defense, emergency preparedness, and consequence management, as well as to prospectively inform the assessment of radiation biomarkers and development of medical prophylaxis countermeasures for defense and homeland security stakeholders and decision-makers. Although dose coefficients have previously been calculated for this group, they would apply specifically to the studied population, the 1945 Japanese cohort, after which their anthropomorphic computational phantoms were modeled. For this reason, applications to other populations may be limited, and instead, an assessment of a more standardized population is desired. We employed a series of computational human phantoms representing international reference individuals: UF/NCI voxel phantom series containing newborn, 1-, 5-, 10-, 15-, and 35-year-old males and females. Irradiation of the phantoms was simulated using the Monte Carlo N-Particle transport code to determine organ dose coefficients under four idealized irradiation geometries at three distances from the detonation hypocenter at Hiroshima and Nagasaki using DS02 free-in-air prompt neutron and photon fluence spectra. Through these simulations, age-specific dose coefficients were determined for individual organs. Various articulated PIMAL stylized phantoms were simulated as well to estimate the effect of body posture on dose coefficients and determine the effect of posture on dosimetric estimation and reconstruction. Results additionally demonstrate that 137 Cs and the Watt fission spectra are not ideal general surrogate sources for fission weapons, which may be considered for experimental testing of medical countermeasures. Supplementary data provided tabulates the compilation of organ dose-rate coefficients in this study.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Guidelines for IAEA Small Specimen Test Techniques Master Curve Fracture Toughness Testing

Under the auspices of International Atomic Energy Agency (IAEA), a coordinated research project (CRP) entitled “Towards the Standardization of Small Specimen Test Techniques for Fusion Applications” has started since 2017. The overall objective of the project is to provide a set of guidelines for small specimen test techniques (SSTT) based on commonly agreed best practices on main test techniques including tensile, creep, low cycle fatigue, fracture toughness, and fatigue crack growth rate. This will act as the first step of a full standardization of the SSTT. Fusion structural materials, i.e., reduced activation ferritic/martensitic (RAFM) steels, are used for testing. In addition, the project will create a comprehensive mechanical property database of RAFM steels tested by SSTT. For the fracture toughness task of the CRP, three testing methods including Master Curve, local approach for ductile crack growth and cleavage fracture, and ductile approach at room temperature will be evaluated. This report focuses on developing guidelines for the round-robin Master Curve testing based on the ASTM standard E1921-19b “Standard Test Method for Determination of Reference Temperature, T 0 , for Ferritic Steels in the Transition Range” and commonly agreed best practice from researchers at Oak Ridge National Laboratory (ORNL), Centre for Energy, Environment and Technology (CIEMAT), and UK Atomic Energy Authority (UKAEA).

36 MATERIALS SCIENCE↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Roadmap to Advance Heliostat Technologies for High Temperature Solar-Thermal Systems

Since its establishment, the Heliostat Consortium (HelioCon) has made substantial progress toward closing many of the gaps in concentrating solar power (CSP) research. Numerous techno-economic studies have been performed, investigating topics ranging from the trade-off between size and temperature for industrial process heat applications to optimization of the heliostat design itself for various applications. Significant improvements have been made in optical metrology techniques, with first steps toward in situ measurement of heliostat fields. Several standards have been, and continue to be, developed with the coordination of an international group of CSP industry participants. Training programs have been developed, with universities including CSP in their engineering curricula, and many public webinars have been held to provide broad access to the latest CSP research. Improved CSP components such as mirror facets and wireless communication systems have been developed, and the solar tower at Sandia National Laboratories has been upgraded with a testbed for closed-loop controls research and development. Field deployment challenges involving heliostat foundations and sensitive wildlife habitats have been explored, with progress made toward methods for streamlining project development and permitting. Additional knowledge has been added to the body of work on wind behavior of heliostats and arrays of heliostats, with progress made toward a holistic understanding of wind design methods. Finally, techniques have been developed and demonstrated for assessing soiling conditions at a proposed project site, with predictive models for the soiling rate showing good results. Taking these results together, HelioCon has contributed greatly to the global CSP research and development effort over the past several years.

14 SOLAR ENERGY↗

Measuring the Stress Factors for Photovoltaic (PV) Backsheet Degradation

Back sheet failure has resulted in power loss and large-scale recall of photovoltaic modules, resulting in billions of dollars in lost revenue. The light exposure on the backside of a photovoltaic module comes primarily from reflected light which alters the distribution of natural sunlight. Because of this, modelling the backside exposure and duplicating the exposure is much more difficult than modeling the frontside exposure. This project aims to study how various back sheets and junction box materials degrade under different conditions and to develop Python code to help model and predict degradation. The stress factors for back-sheet degradation must be quantified to extrapolate accelerated stress tests to the field. Test samples were placed in the A3, A4, and A5 conditions, as defined in IEC 62788-7-2, to assess the temperature and humidity dependence of ultraviolet (UV) induced degradation. We are utilizing a custom chamber with exposure from 0.5 UV-suns to 5 UV-suns to understand the dependence of degradation on light intensity. A group of samples put in the A3 condition had glass filters with 50% UV cut-offs of 320 nm, 335 nm, and 360 nm to assess the wavelength dependence of UV degradation. All this data is necessary to assess the impact of non-standard UV light exposure. The material evaluation tests include gloss measurements, attenuated total internal reflectance Fourier transform infrared spectroscopy (ATR-FTIR), UV-visible reflectance/transmittance utilizing a Cary Ci7000 spectrophotometer, and a nano-indenter for surface hardness and modulus measurements. Alongside the experimental work, there is a computational effort using raytracing and Python open-source tools in PVDeg , PVLib, and Bifacial_Radiance. This code will create specific exposure scenarios and enable the evaluation of chamber degradation relative to field degradation. Equation 1 is a strawman equation used to model degradation on the backside of a PV module. We will create simplified code, based on the results of ray-tracing calculations, which uses a view factor approach to provide fast calculations for the most common exposure scenarios.

14 SOLAR ENERGY↗

Absolute Cavity Pyrgeometer (ACP)

ACP Measures atmospheric longwave irradiance with traceability to the International System of Units (SI). To date the Interim world reference World Infrared Standard Group (WISG) is traceable to blackbody (not sky/atmosphere), and InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. The ACP is self calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Revising the dynamic energy budget theory with a new reserve mobilization rule and three example applications to bacterial growth

Dynamic energy budget (DEB) theory has been applied to model a wide range of organisms, including microbes. In the standard DEB model, biomass is partitioned into reserve and structural compartments, where reserve biomass is mobilized in a pseudolinear manner (while the reserve biomass density, defined as the ratio between reserve and structural biomass, decays linearly) to drive maintenance and the growth of structural biomass (and extracellular enzyme production if it is considered). However, the linear dynamics of the reserve biomass density makes the standard DEB model incapable of explaining the slowdown of microbial growth at high reserve density that is caused by macromolecular crowding effect which reduces biochemical reaction rates (a typical situation occurs when microbes are experiencing severe moisture stress) and is inconsistent with the observation that intracellular enzymatic reactions generally follow non-linear kinetics. By partitioning biomass into reserve, kinetic, and structural compartments, we show here that the Equilibrium Chemistry Approximation (ECA) kinetics can be used to represent enzymatically catalyzed reserve biomass mobilization that can then drive the kinetic and structural biomass synthesis. This revised DEB model better represents the tradeoff in ribosome allocation for structural growth and internal enzyme production, is structurally compatible with metabolic models of cell individuals, and includes the standard DEB model and the popular compromise model as special cases for representing population growth. We then applied the revised DEB model to interpret components of bacterial respiration, their dependence on substrate availability, and emergent microbial carbon use efficiency dynamics for an exponentially growing population. We found that the revised DEB model enables a better understanding of bacterial substrates use (carbon in our examples) than that can be derived from a few other models in the literature. In particular, the revised DEB model explains why carbon use efficiency may first increase, then plateau, and finally decrease with growth rate (and substrate uptake rate), as a function of proteomics. Additionally, the revised DEB model explains why the kinetic biomass compartment needs to be divided to reasonably incorporate proteomic control of microbial growth.

59 BASIC BIOLOGICAL SCIENCES↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Experimental and Numerical Investigation of Internal Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array and Single-Jet Impingement

Over the past decade, the drive to reduce greenhouse gas emissions and to increase thermal efficiency for turbomachinery has invigorated the application of supercritical carbon dioxide (sCO2) power cycles for energy generation. Compared to the industry standard air cycles, sCO2 applications hold the potential for several advantages, including higher efficiencies, smaller footprints, and zero greenhouse gas emissions. However, like any turbomachinery application, the turbine inlet temperature must increase to increase thermal efficiency. This introduces the need for internal cooling features to avoid material failure as operating conditions rise. Two standard features include pin fin turbulators in the trailing edge and jet impingement in the airfoil's leading edge. Over the past several decades, these features have been the subject of extensive research. However, the move to the sCO2 operating environment creates the need to re-visit these features to quantify the heat transfer capabilities within this supercritical cooling environment. The first objective of this paper is to discuss the development of the experimental demonstration for internal heat transfer testing at 200 bar and 400 Celsius, which sits well within the CO2 supercritical region. Next, the heat transfer for pin fin turbulators and single-jet impingement in the sCO2 environment is compared to existing air data-derived correlations to quantify any deviations from literature correlations. Finally, the experimental process aims to validate internal cooling conjugate heat transfer numerical simulations for sCO2 turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Baseline Climate Variables for Earth System Modelling

The Baseline Climate Variables for Earth System Modelling (ESM-BCVs) are defined as a list of 135 variables which have high utility for the evaluation and exploitation of climate simulations. The list reflects the most frequently used elements of the Coupled Model Intercomparison Project Phase 6 (CMIP6) archive. Successive phases of CMIP have supported strong results in science and substantially influence international climate policy formulation. This paper responds to both interest in exploiting CMIP data standards in a broader range of climate modelling activities and a need to achieve greater clarity about the significance and intention of variables in the CMIP Data Request. As Earth system modelling archives grow in scale and complexity, there are emerging problems associated with weak standardisation at the variable collection level. That is, there are good standards covering how specific variables should be archived, but this paper fills a gap in the standardisation of which variables should be archived. The ESM-BCV list is intended as a resource for ESM intercomparison projects (MIPs) developing requests to enable greater consistency among MIPs and as a reference for modelling centres to enhance consistency within MIPs. Provisional planning for the CMIP7 Data Request exploits the ESM-BCVs as a core element. The baseline variable list includes 98 variables which have modest or minor data volume footprints and could be generated systematically when simulations are produced and archived for exploitation by the World Climate Research Programme (WCRP) community. A further 35 variables are classed as “high volume” and are only suitable for production when the resource implications are justified.

Juckes, Martin [University of Oxford (United Kingd↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Ground State Electronic Energy of Benzene

We report here on the findings of a blind challenge devoted to determining the frozen-core, full configuration interaction (FCI) ground-state energy of the benzene molecule in a standard correlation-consistent basis set of double-ζ quality. As a broad international endeavor, our suite of wave function-based correlation methods collectively represents a diverse view of the high-accuracy repertoire offered by modern electronic structure theory. In our assessment, the evaluated high-level methods are all found to qualitatively agree on a final correlation energy, with most methods yielding an estimate of the FCI value around -863 mE H . However, we find the root-mean-square deviation of the energies from the studied methods to be considerable (1.3 mE H ), which in light of the acclaimed performance of each of the methods for smaller molecular systems clearly displays the challenges faced in extending reliable, near-exact correlation methods to larger systems. While the discrepancies exposed by our study thus emphasize the fact that the current state-of-the-art approaches leave room for improvement, we still expect the present assessment to provide a valuable community resource for benchmark and calibration purposes going forward.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗