Search NASASearch

SEARCH · Search NASA

Results for “land use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

778 records · Page 19

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Exploring the Model Design Space for Battery Health Management

Battery Health Management (BHM) is a core enabling technology for the success and widespread adoption of the emerging electric vehicles of today. Although battery chemistries have been studied in detail in literature, an accurate run-time battery life prediction algorithm has eluded us. Current reliability-based techniques are insufficient to manage the use of such batteries when they are an active power source with frequently varying loads in uncertain environments. The amount of usable charge of a battery for a given discharge profile is not only dependent on the starting state-of-charge (SOC), but also other factors like battery health and the discharge or load profile imposed. This paper presents a Particle Filter (PF) based BHM framework with plug-and-play modules for battery models and uncertainty management. The batteries are modeled at three different levels of granularity with associated uncertainty distributions, encoding the basic electrochemical processes of a Lithium-polymer battery. The effects of different choices in the model design space are explored in the context of prediction performance in an electric unmanned aerial vehicle (UAV) application with emulated flight profiles.

Saha, Bhaskar

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

Al/Cl2 molten salt battery

Molten salt battery has been developed with theoretical energy density of 5.2 j/kg (650 W-h/lb). Battery, which operates at 150 C, can be used in primary mode or as rechargeable battery. Battery has aluminum anode and chlorine cathode. Electrolyte is mixture of AlCl3, NaCl, and some alkali metal halide such as KCl.

Giner, J.

SHARP: Automated Monitoring of Spacecraft Health and Status

This paper briefly describes the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory and highlights some difficulties associated with the existing technology used in mission operations. A new automated system based on artificial intelligence technology is described which seeks to overcome many of these limitations. The system, called the Spacecraft Health Automated Reasoning Prototype (SHARP), is designed to automate health and status analysis for multi-mission spacecraft and ground data systems operations. The SHARP system has proved to be effective for detecting and analyzing potential spacecraft and ground systems problems by performing real-time analysis of spacecraft and ground data systems engineering telemetry. Telecommunications link analysis of the Voyager 2 spacecraft was the initial focus for evaluation of the system in a real-time operations setting during the Voyager spacecraft encounter with Neptune in August, 1989. The SHARP system will be delivered to the JPL Space Flight Operations Center for regular use by planetary flight projects, including the Galileo and Magellan spacecraft, and will also be applied to monitoring and control applications in the Deep Space Network's Network Operations Control Center.

David J Atkinson

Power and Propulsion Element Steerable High Gain Antenna Lunar Transit Thermal Analysis Tracking Methodology

The Power and Propulsion Element (PPE) is an ion thruster propulsion spacecraft developed as an element of Space Reactor (SR-1) Freedom to provide propulsion, communications and power for the spacecraft. PPE was originally being developed for the use with the lunar orbiting space station Gateway as one of the first two planned elements. PPE was to be launched with the Habitation and Logistics Outpost (HALO) element in a configuration called the Co-Manifested Vehicle (CMV) that would arrive at a Near-Rectilinear Halo Orbit (NRHO) around the Moon via a lunar transit spiral trajectory phase. The PPE communication system is equipped with two Steerable High Gain Antennas (SHGA) each steered by a two-axis gimbal (TAG) mechanism. A thermal analysis was conducted during the near-Earth spiral phase of the mission using Thermal Desktop (TD). This analysis utilized multiple axis Earth tracking articulators in combination with SINDA system internal environmental heating symbols to produce accurate Earth ground station tracking communication system temperatures. This presentation provides an overview of the communication system thermal model and the analysis methodology.

Thermal Analysis

Development of a Digital Twin for Electrified Aircraft Powertrain Health Management

The augmentation of aircraft powertrains with electrical power systems is a promising path to reducing aircraft fuel consumption, emissions, and noise. Like conventional propulsion systems, electrified aircraft propulsion (EAP) systems will be subject to wear and tear throughout their lifecycles. System health management for EAP will enable efficient flight and maintenance scheduling, realizing economic, safety, and reliability benefits. A digital twin is, broadly, a dynamically updated virtual representation of an individual physical asset. This paper presents a Kalman filter-based approach for the development of a digital twin for an electrified powertrain and applies the approach to an EAP controls testbed. Measurements from nominal testbed operations are used to update a nonlinear model of the testbed. A Kalman filter is then created and used to identify and isolate anomalous testbed behavior based on measurements from off- nominal operations. Results show that the Kalman filter-based digital twin can monitor individual powertrain components’ health for degradation or other changes in performance. The applicability of the presented digital twin approach to any hybrid- or fully-electrified powertrain is emphasized.

Electrified Aircraft Propulsion

Development of an Additively Manufactured Subscale Secondary Sealed Container for the NASA FROSTE Project

This presentation details the development of an additively manufactured (AM) subscale test article for the secondary sealed container (SSC) as part of the NASA FROSTE project. FROSTE is focused on the collection of regolith samples from shadowed regions of the Moon and the preservation of those samples at cryogenic temperatures for return to Earth. Our team was integrated into the FROSTE program to leverage innovative design approaches and additive manufacturing capabilities in support of a scalable development strategy, where the subscale configuration serves as the development path toward a full-scale SSC. Scalmalloy was selected as the primary material for all AM components due to its favorable strength-to-weight ratio, thermal conductivity, and demonstrated performance in aerospace applications. Its aluminum-based composition supports robust mechanical behavior at cryogenic temperatures while enabling efficient heat transfer and control of thermal gradients within the containment system. The SSC architecture consists of an outer container assembly that houses a phase change material (PCM) tank, which in turn contains primary containers holding the regolith. Thermal management relies on controlled conductive and radiative heat transfer, including a thermal connection assembly that interfaces the PCM tank to an external cryocooler via a thermal strap, and IMLI surrounding the PCM tank to inhibit radiative heat transfer. The outer container assembly incorporates sealing interfaces, thermal connection ports, and I/O feedthroughs, with PTFE spring seals used at critical interfaces to maintain containment integrity. The PCM tank is manufactured as a single monolithic Scalmalloy component and incorporates an integral lattice structure to minimize thermal gradients, internal channels for thermocouple routing, and interface features for thermal connection assembly integration. The tank is centrally suspended within the outer container using support rings, with G10 insulating components employed to inhibit thermal leaks. This work describes the design methodology, AM approach, and key considerations used to inform the design.

regolith

Ka-Band Monopulse Antenna-Pointing Systems Analysis and Simulation

NASA's Deep Space Network (DSN) has been using both 70-m and 34-m reflector antennas to communicate with spacecraft at S-band (2.3 GHz) and X-band (8.45 GHz). To improve the quality of telecommunication and to meet future mission requirements, JPL has been developing 34-m Ka-band (32-GHz) beamwave guide antennas. Presently, antenna pointing operates in either the open-loop mode with blind pointing using navigation predicts or the closed-loop mode with conical scan (conscan). Pointing accuracy under normal conscan operating conditions is in the neighborhood of 5 mdeg. This is acceptable at S- and X-bands, but not enough at Ka-band. Due to the narrow beamwidth at Ka-band, it is important to improve pointing accuracy significantly (approx. 2 mdeg). Monopulse antenna tracking is one scheme being developed to meet the stringent pointing-accuracy requirement at Ka-band. Other advantages of monopulse tracking include low sensitivity to signal amplitude fluctuations as well as single-pulse processing for acquisition and tracking. This article presents system modeling, signal processing, simulation, and implementation of Ka-band monopulse tracking feed for antennas in NASA/DSN ground stations.

V Y Lo

International Space Station Lithium-Ion Battery

The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.

battery

Aerothermodynamic Analysis of a Flexible Thermal Protection System under Reentry Loads

The Carryall Block 1 reentry vehicle being developed by Outpost Space utilizes a strut supported semirigid deployable heatshield. This consists of a flexible thermal protection system, a heat-resistant fabric stack, stretched over actuated spars. The advantages of a deployable heatshield include reduced heat loading and earlier deceleration in the trajectory. However, the nature of the flexible thermal protection system necessitates considering the loaded shape of the heat shield. The flexible thermal protection system will deflect under reentry loads leading to areas of higher heating rates as well as a reduced axial coefficient as compared to the nominal shape. The Carryall Block 1 is analyzed using NASA’s FUN3D and DPLR CFD solvers with a deflected shape based on the catenary equations. The aerodynamic results are found to be within a percent for both solvers and both structured and unstructured mesh types. Fluid Structure Interaction (FSI) analysis is currently a work in progress, using file I/O to communicate between FUN3D and LS-DYNA, a commercial nonlinear structural solver. Challenges in deforming the geometry, mesh, and initial results are presented here.

thermal protection system

International Space Station Lithium-Ion Battery Start-Up

International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.

Lithium-Ion

Stationary Testing of a Pulse Tube Cryocooler Designed to Rotate at 6800 RPM with the Superconducting Rotor of an Electric Machine

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Most of these electric machines employ superconductors on their rotor, thereby requiring cryogenic cooling of the rotating system. An attractive solution is to conductively cool the rotor using a cryocooler that rotates with the rotor. NASA has been developing a 50 K pulse tube cryocooler for its High Efficiency Megawatt Motor (HEMM) that can operate while rotating at 6,800 rpm. The design of this cryocooler and testing of its linear motor have been discussed in prior work. This presentation presents the first measurements of the complete HEMM cryocooler. The design and results of a stationary (non-rotating) test of the cryocooler are described.

electrified aircraft propulsion

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing

Lithium Battery Space Experiment

The Jet Propulsion Laboratory will test a lithium battery (Li- TiS2) in orbit and examine the battery after it is returned to Earth. The results will be used to suggest design changes for a battery that may eventually be 3-4 times lighter than the equivalent NiCd battery.

battery