Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Spectrally resolved Rayleigh scattering diagnostic for hydrogen-oxygen rocket plume studies

A Rayleigh scattering diagnostic has been developed to measure gas density, temperature, and velocity in the exhaust plume of 100 N thrust class hydrogen-oxygen rockets. The spectrum of argon-ion laser light scattered by the gas molecules in the plume (predominantly water vapor) is measured with a scanning Fabry-Perot interferometer. The gas density is determined from the total scattered power, the gas temperature from the spectral width, and the velocity from the shift in the peak of the spectrum from the frequency of the incident laser light. The diagnostic has been demonstrated in a rocket test cell and a discussion of results is given.

Seasholtz, R. G.↗

Evaluation of emission contributions from charge-exchange between the excited states of deuterium with He + during diagnostic of thermal helium gas beam injection and laser-induced fluorescence

Emission contributions from charge-exchange of excited deuterium ( n = 2, 3) with He + are evaluated in a1-D kinetic collisional radiative model in order to analyze their effects on the Thermal Helium Beam (THB) line-ratio diagnostic on ASDEX Upgrade and Laser Induced Fluorescence (LIF) He I density measurements in ITER. Recent charge-exchange calculations show that cross sections from excited deuterium ( n = 2, 3) with He + are over 4-orders of magnitude higher than those from the ground state ( n = 1) and occur at very low energies where they are more likely to interact with the thermal He + ions introduced by ionization of the diagnostic helium gas-puff injection. Higher densities of excited deuterium are typically present in the Scrape-Off Layer (SOL), divertor, and edge regions of tokamaks, where the LIF and THB helium diagnostics are typically used for n HeI and simultaneous determination of electron temperatures and densities and where contributions from charge-exchange emission may offset these values if not taken into account. The analysis presented in this work shows that due to the higher density of deuterium in the ground rather than in excited states and the divergent behavior of deuterium and He + density profiles along the SOL and edge regions, the deuterium-He + charge-exchange contributions to the helium puff emission are 3-orders of magnitude lower than those from electron-impact excitation. Similar plasma conditions are expected in the ITER divertor, with the exception that in the area near the strike-points and targets, the electron temperature is not high enough to excite from the ground state but deuterium, electron, and He + densities are high enough to dominate the emission from charge-exchange and recombination. These findings strengthen the assumption made in the present line-ratio model that helium emission from gas-puff into plasma is mainly dominated by electron-excitation. It is also shown that, in general, charge-exchange helium emission is 2-orders of magnitude higher than the emission due to recombination. Finally, these findings suggest the importance of including charge-exchange processes as a source of neutrals in ionic fractional abundance calculations in plasmas and helium-ash transport modeling in fusion reactors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-intrusive measurement of magnetic field strengths in a low-pressure argon plasma using quantum beat spectroscopy

Abstract Accurate measurement of magnetic field strengths is critical in many plasma environments, ranging from astrophysical systems to fusion energy research. In this work, a non-perturbative laser-based optical diagnostic known as quantum beat spectroscopy is demonstrated to be good alternative for measuring the magnetic field strength in low-pressure laboratory plasmas. The technique is investigated using both ns and fs pulsed lasers in an argon plasma. Preliminary results for a helium plasma are also given. Zeeman-split J = 1 electron states with transitions from metastable states were identified and tested for neutral argon ( 2 P 1 / 2 o ) 4 p 2 [ 1 / 2 ] and neutral helium 1 s 3 p 1 P 1 o . Magnetic fields are measured with sub-Gauss precision at near single laser pulse acquisition rates.

Gilbert, Tyler J. (ORCID:0000000160400119)↗

Rapid retrieval of first-order spatiotemporal distortions for ultrashort laser pulses

High-intensity, ultrashort laser sources are a foundational pillar for High-Energy-Density (HED) physics, and as the repetition-rates of these systems increase, diagnostics must be developed to match their data collection speed. Characterization of any spatiotemporal distortions in the laser pulse is necessary in order to standardize results across facilities. Here, we have previously developed a laser diagnostic called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, or STRIPED FISH, to measure the full spatiotemporal laser electric field on a single shot. In order to provide rapid feedback, we here adapt the STRIPED FISH retrieval algorithm, which typically has computation times of up to 30 minutes due to the high spatial resolution of the device and its retrieval of the complete four-dimensional pulse field, to distill the key electric field quantities into a handful of scalars for rapid assessment of the pulse's first order distortions. Here, our new, rapid non-iterative retrieval algorithm is validated with simulated and experimental data, and it provides, within seconds, the same first-order information as given by the full analysis. This algorithm is suitable for on-shot assessment of spatiotemporal distortions and can be adapted to assess high repetition-rate laser quality in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanotube Activities at NASA-Johnson Space Center

Nanotube activities at NASA-Johnson Space Center include production, purification, characterization as well as applications of single wall carbon nanotubes (SWCNTs). A parametric study of the pulsed laser ablation process is recently completed to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Enhancement of production is achieved by rastering the graphite target and by increasing the target surface temperature with a cw laser. In-situ diagnostics during production included time resolved passive emission and laser induced fluorescence from the plume. The improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymer/nanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large Surface area as well as high electrical and thermal conductivity exhibited by SWCNTs. Comparison with existing technologies and possible future improvements in the SWCNT materials sill be presented.

Arepalli, Sivaram↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Quantitative Detection of Combustion Species using Ultra-Violet Diode Lasers

Southwest Sciences is developing a new microgravity combustion diagnostic based on UV diode lasers. The instrument will allow absolute concentration measurements of combustion species on a variety of microgravity combustion platforms including the Space Station. Our approach uses newly available room temperature UV diode lasers, thereby keeping the instrument compact, rugged and energy efficient. The feasibility of the technique was demonstrated by measurement of CH radicals in laboratory flames. Further progress in fabrication technology of UV diode lasers at shorter wavelengths and higher power will result in detection of transient species in the deeper UV. High sensitivity detection of combustion radicals is provided with wavelength modulation absorption spectroscopy.

Pilgrim, J. S.↗

Fuel Injector Patternation Evaluation in Advanced Liquid-Fueled, High Pressure, Gas Turbine Combustors, Using Nonintrusive Optical Diagnostic Techniques

Planar laser-induced fluorescence (PLIF) imaging and planar Mie scattering are used to examine the fuel distribution pattern (patternation) for advanced fuel injector concepts in kerosene burning, high pressure gas turbine combustors. Three diverse fuel injector concepts for aerospace applications were investigated under a broad range of operating conditions. Fuel PLIF patternation results are contrasted with those obtained by planar Mie scattering. Further comparison is also made for one injector with data obtained through phase Doppler measurements. Differences in spray patterns for diverse conditions and fuel injector configurations are readily discernible. An examination of the data has shown that a direct determination of the fuel spray angle at realistic conditions is also possible. The results obtained in this study demonstrate the applicability and usefulness of these nonintrusive optical techniques for investigating fuel spray patternation under actual combustor conditions.

Locke, R. J.↗

View factor estimation of hot spot velocities in inertial confinement fusion implosions at the National Ignition Facility

nertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) suffer from asymmetries in thex-ray drive that degrade capsule performance compared to expectations for a symmetric one-dimensional implosion.Mode 1, or pole-to-pole, drive asymmetry can reduce confinement and implosion efficiency, driving a bulk motion ofthe hot spot that is detectable with neutron diagnostics. Understanding and removing sources of mode 1 asymmetry inICF implosions is important for improving performance, and the three-dimensional nature of the problem makes high-resolution radiation-hydrodynamic modeling extremely computationally expensive. This work describes a reducedorder view factor model that calculates the drive asymmetry induced by beam-to-beam variations in laser delivery andhohlraum diagnostic windows along the equator. Capsule response is estimated by coupling to a Green’s function thatrelates final hot spot velocity to the applied time-varying mode 1 asymmetry. The model makes several predictionsabout the impact of mode 1 drivers such as laser delivery and target misalignment, and achieves good agreementin both magnitude and vector direction for several shots in three families of high-performance platforms. However,notable discrepancies suggest other potential sources of mode 1 asymmetry not captured by the model are also at play

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous sampling technique for two spectral sources

A technique is described that uses a bundle of fiber optics to simultaneously sample a dye laser and a spectral lamp. By the use of a real-time display with this technique, the two signals can be superimposed, and the effect of any spectral adjustments can be immediately accessed. In the NASA's CARS system used for combustion diagnostics, the dye laser mixes with a simultaneously pulsed Nd:YAG laser at 532 nm to probe the vibrational levels of nitrogen. An illustration of the oscilloscopic display of the system is presented.

Jarrett, Olin, Jr.↗

LICS Modeling [Slides]

We propose to design a new diagnostic based on laser inverse Compton scattering (LICS) to study the dynamics of runaway electron formation during killer-pellet triggered disruptions in DIII-D, and their subsequent loss. Obtaining a better understanding of transient runaway electrons (and how to suppress them) is one of the highest priorities of the US fusion program. To enable this, we need better measurements of the runaway electron population during and after disruptions. We intend to measure point-wise time-resolved spatial profile and energy distributions of the runaway electrons while they are in the core of the tokamak plasma. While LICS measurements of relativistic e-beams have been successfully made on accelerators, they have never been done in a tokamak. We bring two innovations to this diagnostic concept which should enable 10 times better signal-to-noise ratios than previously envisioned. In particular, we will marry bright short pulse (10’s of picosecond) laser technologies with the availability of short-pulse gated x-ray imagers developed at Los Alamos for the National Ignition Facility (NIF), to reject noise generated by the tokamak and plasma environment. We will generate a Conceptual Physics Basis, a Preliminary Design, and a Final Design package, with associated DIII-D reviews, along with prototype component testing for the diagnostic over the course of the two year duration of this proposal.

42 ENGINEERING↗

Recent Advances in Synthesis and Characterization of SWCNTs Produced by Laser Oven Process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics. Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. In-situ diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Aepalli, Sivaram↗

Recent Advances in Synthesis and Characterization of SWCNTs produced by laser oven process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics (ref. 1). Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. Insitu diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Arepalli, Sivaram↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

Qualitative and quantitative enhancement of parameter estimation for model-based diagnostics using automatic differentiation with an application to inertial fusion

Parameter estimation using observables is a fundamental concept in the experimental sciences. Mathematical models that represent the physical processes can enable reconstructions of the experimental observables and greatly assist in parameter estimation by turning it into an optimization problem which can be solved by gradient-free or gradient-based methods. In this work, the recent rise in flexible frameworks for developing differentiable scientific computing programs is leveraged in order to dramatically accelerate data analysis of a common experimental diagnostic relevant to laser–plasma and inertial fusion experiments, Thomson scattering. A differentiable Thomson-scattering data analysis tool is developed that uses reverse-mode automatic differentiation (AD) to calculate gradients. By switching from finite differencing to reverse-mode AD, three distinct outcomes are achieved. First, gradient descent is accelerated dramatically to the extent that it enables near real-time usage in laser–plasma experiments. Second, qualitatively novel quantities which require $\mathcal{O}(10^3)$ parameters can now be included in the analysis of data which enables unprecedented measurements of small-scale laser–plasma phenomena. Third, uncertainty estimation approaches that leverage the value of the Hessian become accurate and efficient because reverse-mode AD can be used for calculating the Hessian.

97 MATHEMATICS AND COMPUTING↗