Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

338 records · Page 19

Characterization of groove density variation of VLS gratings with ALS XROL LTP-II in different operation modes

The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.

42 ENGINEERING↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of three measurement modalities for 3D characterization of manufactured features and process-induced porosity in titanium alloy additively manufactured parts

Nondestructive characterization of internal features and defects within complex components is vital for many industrial applications, particularly with the advent of additive manufacturing (AM) technologies. However, community understanding of the limitations of nondestructive methods such as X-ray Computed Tomography (CT) can be limited in certain industrial sectors as these may be emergent applications. In this paper, we investigate the limits of X-ray CT measurements and compare extracted data with mechanical polishing serial sectioning (MPSS) and confocal laser scanning microscopy (CLSM). The test object is an additively manufactured titanium alloy disk that contains both process-induced porosity and machined features, including focused ion beam milled features designed to probe the resolution limits of X-ray CT. Results show that each of these characterization techniques has advantages and disadvantages. We compare data acquisition times, spatial resolution, geometric measurement accuracy and defect visualization fidelity across these modalities to establish a practical framework.

Additive manufacturing↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA Tech Briefs, May 2011

Topics covered include: 1) Method to Estimate the Dissolved Air Content in Hydraulic Fluid; 2) Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes; 3) High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence; 4)Metrology Arrangement for Measuring the Positions of Mirrors of a Submillimeter Telescope; 5) On-Wafer S-Parameter Measurements in the 325-508-GHz Band; 6) Reconfigurable Microwave Phase Delay Element for Frequency Reference and Phase-Shifter Applications; 7) High-Speed Isolation Board for Flight Hardware Testing; 8) High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors; 9) 3D Orbit Visualization for Earth-Observing Missions; 10) MaROS: Web Visualization of Mars Orbiting and Landed Assets; 11) RAPID: Collaborative Commanding and Monitoring of Lunar Assets; 12) Image Segmentation, Registration, Compression, and Matching; 13) Image Calibration; 14) Rapid ISS Power Availability Simulator; 15) A Method of Strengthening Composite/Metal Joints; 16) Pre-Finishing of SiC for Optical Applications; 17) Optimization of Indium Bump Morphology for Improved Flip Chip Devices; 18) Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures; 19) Marshall Convergent Spray Formulation Improvement for High Temperatures; 20) Real-Time Deposition Monitor for Ultrathin Conductive Films; 21) Optimized Li-Ion Electrolytes Containing Triphenyl Phosphate as a Flame-Retardant Additive; 22) Radiation-Resistant Hybrid Lotus Effect for Achieving Photoelectrocatalytic Self-Cleaning Anticontamination Coatings; 23) Improved, Low-Stress Economical Submerged Pipeline; 24) Optical Fiber Array Assemblies for Space Flight on the Lunar Reconnaissance Orbiter; 25) Local Leak Detection and Health Monitoring of Pressurized Tanks; 26) Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging; 27) Automated Cryocooler Monitor and Control System; 28) Broadband Achromatic Phase Shifter for a Nulling Interferometer; 29) Super Dwarf Wheat for Growth in Confined Spaces; 30) Fine Guidance Sensing for Coronagraphic Observatories; 31) Single-Antenna Temperature- and Humidity-Sounding Microwave Receiver; 32) Multi-Wavelength, Multi-Beam, and Polarization-Sensitive Laser Transmitter for Surface Mapping; 33) Optical Communications Link to Airborne Transceiver; 34) Ascent Heating Thermal Analysis on Spacecraft Adaptor Fairings; 35) Entanglement in Self-Supervised Dynamics; 36) Prioritized LT Codes; 37) Fast Image Texture Classification Using Decision Trees; 38) Constraint Embedding Technique for Multibody System Dynamics; 39) Improved Systematic Pointing Error Model for the DSN Antennas; 40) Observability and Estimation of Distributed Space Systems via Local Information-Exchange Networks; 41) More-Accurate Model of Flows in Rocket Injectors; 42) In-Orbit Instrument-Pointing Calibration Using the Moon as a Target; 43) Reliability of Ceramic Column Grid Array Interconnect Packages Under Extreme Temperatures; 44) Six Degrees-of-Freedom Ascent Control for Small-Body Touch and Go; and 45) Optical-Path-Difference Linear Mechanism for the Panchromatic Fourier Transform Spectrometer.

Source record↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

LISA Pathfinder

USA Pathfinder is a space mission dedicated to demonstrating technology for the Laser Interferometer Space Antenna (LISA). LISA is a joint ESA/NASA mission to detect low-frequency gravitational waves on the 0.0001 to 0.1 Hz frequency band. LISA is expected to observe 100's of merging massive black hole binaries out z-15, tens of thousands of close compact binary systems in the Milky Way, merging intermediate-mass black hole binaries, tens of stellar-mass black holes falling into supermassive black holes in galactic centers, and possibly other exotic sources. Several critical LISA technologies have not been demonstrated at the requisite level of performance. In spaceflight, and some fight hardware cannot be tested in a 1-g environment. Hence, the LISA Pathfinder mission is being implemented to demonstrate these critical LISA technologies in a relevant flight environment. LISA Pathfinder mimics one arm of the LISA constellation by shrinking the 5-million-kilometer armlength down to a few tens of centimeters. The experimental concept is to measure the relative separation between two test masses nominally following their own geodesics, and thereby determine the relative residual acceleration between them near 1 mHz, about a decade above the lowest frequency required by LISA. To implement such a concept, disturbances on the test masses must be kept very small by many design features, but chiefly by "drag-free" flight. A drag-free spacecraft follows a free-falling test mass which it encloses, but has no mechanical connection to. The spacecraft senses it's orientation and separation with respect to the proof mass, and its propulsion system is commanded to keep the spacecraft centered about the test mass. Thus, the spacecraft shields the test mass from most external influences, and minimizes the effect of force gradients arising from the spacecraft, and acting on the test mass. LISA Pathfinder will compare the geodesic of one test mass against that of the other. Only a metrology system based on interferometry can achieve the displacement sensitivity. Interferometers monitor the separation of both test masses with a sensitivity comparable to that required by LISA, and using the same technologies. LISA Pathfinder is scheduled to be launched in the first half of 1020 to a Lissajous orbit around the first Sun-Earth Lagrange point, L1. In addition to a complete European technology package (the LISA Technology Package, or LTP), LISA Pathfinder will also carry thrusters and software, known as ST-7, a part of NASA's New Millennium Program.

Stebbins, Robin↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

Electric Field Analysis in a Cold-Ion Source Using Stark Spectroscopy of Rydberg Atoms

Here, we analyze electric fields in ion sources generated by quasicontinuous photoionization of cold Rb atoms trapped in the focal spot of a near-concentric, in-vacuum cavity for 1064-nm laser light. Ion streams are extracted with an external electric field, F. Stark effects of Rb 57F and of nearby high-angular-momentum Rydberg levels, which exhibit large, linear Stark shifts, are employed to study the net electric-field probability distribution within the ion-source region over an extraction-field range of 0 < F < 0.35 V/cm. For F = 0, we also investigate ion-field-induced Stark spectra of the 60P 1/2 state, which exhibits a (lesser) quadratic electric-field response that affords a simplified electric-field analysis. Experimental Rydberg spectra are compared with theoretical Stark spectra, which are weighted with net electric-field distributions obtained from classical ion-trajectory simulations that include Coulomb interactions. Experiments and models are in good agreement. At small F and high ion-source rates, the field approximately follows a Holtsmark distribution, and the ion streams are degraded by the Coulomb microfields. With increasing F and at lower ion-source rates, the fields become narrowly distributed around F, resulting in directional ion streams that are less degraded by microfields. Our results are of interest for monitoring cold-ion sources for focused-ion-beam applications, where Coulomb interactions are of concern, and for studies of electric fields in cold plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Shock equation of state experiments in MgO up to 1.5 TPa and the effects of optical depth on temperature determination

Laser-driven shock compression enables an experimental study of phase transitions at unprecedented pressures and temperatures. One example is the shock Hugoniot of magnesium oxide (MgO), which crosses the B1–B2-liquid triple point at 400–600 GPa, 10 000–13 000 K (0.86–1.12 eV). MgO is a major component within the mantles of terrestrial planets and has long been a focus of high-pressure research. Here, we combine time-resolved velocimetry and pyrometry measurements with a decaying shock platform to obtain pressure–temperature data on MgO from 300 to 1500 GPa and 9000 to 50 000 K. Pressure–temperature–density Hugoniot data are reported at 1500 GPa. These data represent the near-instantaneous response of an MgO [100] single crystal to shock compression. We report on a prominent temperature anomaly between 400 and 460 GPa, in general agreement with previous shock studies, and draw comparison with equation-of-state models. We provide a detailed analysis of the decaying shock compression platform, including a treatment of a pressure-dependent optical depth near the shock front. We show that if the optical depth of the shocked material is larger than 1 μm, treating the shock front as an optically thick gray body will lead to a noticeable overestimation of the shock temperature.

36 MATERIALS SCIENCE↗

High-precision phase control of an optical lattice with up to 50 dB noise suppression

An optical lattice is a periodic light crystal constructed from the standing-wave interference patterns of laser beams. It can be used to store and manipulate quantum degenerate atoms and is an ideal platform for the quantum simulation of many-body physics. A principal feature is that optical lattices are flexible and possess a variety of multidimensional geometries with modifiable band structure. An even richer landscape emerges when control functions can be applied to the lattice by modulation of the position or amplitude with Floquet driving. However, the desire of realizing high-modulation bandwidths while preserving extreme lattice stability has been difficult to achieve. In this paper, we demonstrate an effective solution that consists of overlapping two counterpropagating lattice beams and controlling the phase and intensity of each with independent acousto-optic modulators. Our phase controller mixes sampled light from both lattice beams with a common optical reference. This dual heterodyne locking method allows exquisite determination of the lattice position, while also removing parasitic phase noise accrued as the beams travel along separate paths. Here, we report up to 50 dB suppression in lattice phase noise in the 0.1–1 Hz band, along with significant suppression spanning more than 4 decades of frequency. The absolute phase diffusion of the lattice position is only 10 Å when integrated over 10 s. This method permits precise, high-bandwidth modulation (greater than 50 kHz) of the optical lattice intensity and phase. We demonstrate the efficacy of this approach by executing intricate time-varying phase profiles for atom interferometry.

Atom interferometry↗

Parametrically designed surface topography on CAD models of additively manufactured lattice structures for improved design validation

Additively Manufactured (AM) lattice structures of the laser powder bed fusion (LPBF) process generally have different surface geometries depending on the overhang angle and location. This means that the design validation stage is often challenging, considering it is based on an ideal Computer Aided Design (CAD) model that is not truly representative, since the AM part will be different in terms of dimensional accuracy and surface finish. Previous studies have relied on the design of surface textures that are independent of the overhang angle, or techniques based on directly using X-ray Computed Tomography (XCT) data. In this paper, a new technique for designing surface texture on the CAD of lattices has been investigated and correlated with areal surface roughness parameters. After extracting areal surface parameters from the XCT data of the lattice, the method allowed for the design of this surface texture on the part CAD taking in consideration if its up skin or down skin, without using XCT data as the main input. By applying this method, it is possible to obtain a lattice CAD model with a designed surface texture and geometry that is more representative of the actual AM lattice. The mean deviation between the CAD model with the designed surface and the XCT was a third of the one between the XCT and the initial CAD. The proposed method allows for designing and replicating LPBF AM surfaces on the CAD of a lattice, taking into consideration the dimensional deviation caused by AM surfaces, especially on overhangs. Assuming that an LPBF AM process is stable and produces approximately the same AM surface, this method can be used to predict the geometry of a lattice, providing a cost-effective and efficient methodology that minimizes the time needed for design validation.

42 ENGINEERING↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗